Beat-to-Beat Alternating Bundle-Branch Block

Keywords:
Arrhythmias, Cardiac; Electrocardiography/methods; Atrioventricular Block; Hospitalization; Permanent Pacemaker

A 67-year-old man was admitted to the primary healthcare emergency department due to dizziness. During the physical examination, an irregular heart rhythm was detected, prompting a request for a 12-lead electrocardiogram (ECG). The ECG (Figure 1) revealed a beat-to-beat alternating pattern of right and left bundle branch blocks (RBBB and LBBB) with Mobitz I second-degree atrioventricular (AV) block.

Figure 1
Alternating Bundle Branch Block (beat-to-beat alternation between RBBB and LBBB), with Mobitz I second-degree AV block.

The patient was transferred to the hospital emergency department, where two consecutive ECGs were performed. One ECG (Figure 2) showed persistent LBBB with first-degree AV block (PR interval of 320ms), and the subsequent ECG (Figure 3) indicated persistent RBBB with left anterior fascicular block and fixed 2:1 second-degree AV block.

Figure 2
Persistent LBBB with first-degree AV block (PR interval of 320ms).
Figure 3
Persistent RBBB with left anterior fascicular block and fixed 2:1 second-degree AV block.

The two sequential ECGs, performed at a few minute intervals, complemented the diagnosis of the first ECG (Figure 1), which showed a beat-to-beat alternation between RBBB and LBBB with Mobitz I second-degree AV block. As demonstrated in this clinical case, this alternating intraventricular conduction block can occur intermittently or persistently. The exact mechanism behind alternating block is not always fully understood; it might be related to abnormalities in the His-Purkinje system, associated with structural heart disease, such as fibrosis or scarring in the conduction system, as well as other mechanisms that may be more or less common.11 Carbone V, Tedesco MA. Bundle branch block on alternate beats: By what mechanism? J Electrocardiol. 2002;35(2):147–52. doi: 10.1054/jelc.2002.32337
https://doi.org/10.1054/jelc.2002.32337...

As depicted in this case, there is a variable conduction delay in both ventricular branches, which can be explained by different refractory periods.22 Saini A, Padala SK, Koneru JN, Ellenbogen KA. Alternating bundle-branch block. Circulation. 2018;137(11):1192–4. doi: 10.1161/circulationaha.118.033637
https://doi.org/10.1161/circulationaha.1...
In this case, when the PR interval is shorter, the electrical stimulus descends through the left branch (RBBB pattern), and when the PR interval is longer, the stimulus descends through the right branch (LBBB pattern). Additionally, the delay or blockage of the AV node also varies, particularly with underlying atrial frequency variability, with more advanced AV block at higher atrial frequencies. Hence, these three electrocardiograms display varying degrees of AV block: Mobitz I second-degree AV block in the first ECG (Figure 1), first-degree AV block in the second ECG (Figure 2), and fixed 2:1 second-degree AV block in the third ECG (Figure 3).

The electrocardiographic recording of alternating bundle branch block is rare in clinical practice,3 and it is even more unusual to find this pattern in the same ECG, with beat-to-beat alternating conduction and, additionally, with AV block. Some authors state that alternating bundle branch block constitutes approximately 6% of all bundle branch blocks, and the primary concern with this rhythm disturbance is the potential risk of complete AV block, which is a Class I indication for permanent pacemaker implantation.33 Glikson M, Nielsen JC, Kronborg MB, Michowitz Y, Auricchio A, Barbash IM, et al. 2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy. Eur Heart J. 2021;42(35):3427–520. doi: 10.1093/eurheartj/ehab364
https://doi.org/10.1093/eurheartj/ehab36...
,44 Mitręga K, Lenarczyk R, Pruszkowska P, Kalarus Z, Średniawa B. Alternating left and right bundle branch block. Kardiol Pol. 2014;72(10):987. doi: 10.5603/KP.2014.0198
https://doi.org/10.5603/KP.2014.0198...

Therefore, the patient was admitted to the Cardiology department and underwent the implantation of a dual-chamber permanent pacemaker.

  • Sources of funding
    There were no external funding sources for this study.
  • Study association
    This study is not associated with any thesis or dissertation work.
  • Ethics approval and consent to participate
    This article does not contain any studies with human participants or animals performed by any of the authors.

Referências

  • 1
    Carbone V, Tedesco MA. Bundle branch block on alternate beats: By what mechanism? J Electrocardiol. 2002;35(2):147–52. doi: 10.1054/jelc.2002.32337
    » https://doi.org/10.1054/jelc.2002.32337
  • 2
    Saini A, Padala SK, Koneru JN, Ellenbogen KA. Alternating bundle-branch block. Circulation. 2018;137(11):1192–4. doi: 10.1161/circulationaha.118.033637
    » https://doi.org/10.1161/circulationaha.118.033637
  • 3
    Glikson M, Nielsen JC, Kronborg MB, Michowitz Y, Auricchio A, Barbash IM, et al. 2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy. Eur Heart J. 2021;42(35):3427–520. doi: 10.1093/eurheartj/ehab364
    » https://doi.org/10.1093/eurheartj/ehab364
  • 4
    Mitręga K, Lenarczyk R, Pruszkowska P, Kalarus Z, Średniawa B. Alternating left and right bundle branch block. Kardiol Pol. 2014;72(10):987. doi: 10.5603/KP.2014.0198
    » https://doi.org/10.5603/KP.2014.0198

Edited by

Editor responsible for the review: Mauricio Scanavacca

Publication Dates

  • Publication in this collection
    08 Jan 2024
  • Date of issue
    2023

History

  • Received
    05 Mar 2023
  • Reviewed
    01 July 2023
  • Accepted
    04 Oct 2023
Sociedade Brasileira de Cardiologia - SBC Avenida Marechal Câmara, 160, sala: 330, Centro, CEP: 20020-907, (21) 3478-2700 - Rio de Janeiro - RJ - Brazil, Fax: +55 21 3478-2770 - São Paulo - SP - Brazil
E-mail: revista@cardiol.br