Acessibilidade / Reportar erro
Arquivos Brasileiros de Oftalmologia, Volume: 65, Número: 6, Publicado: 2002
  • Sobre vitórias e esperanças Editorial

    Bicas, Harley E. A.; Muccioli, Cristina; Campos, Mauro S. Q.; Goldchmit, Mauro; Bechara, Samir J.; Costa, Vital P. da
  • Achados ecográficos em pacientes com catarata total Artigos Originais

    Corrêa, Zélia Maria da Silva; Goldhardt, Raquel; Marcon, Alexandre Seminoti; Marcon, Ítalo Mundialino

    Resumo em Português:

    Objetivos: Avaliar a prevalência e a natureza das anomalias intra-oculares detectadas no exame de ultra-som em pacientes com catarata densa (total) e comparar estes achados com aqueles obtidos após cirurgia de catarata. Métodos: Foram revisados 724 ultra-sonografias oculares realizadas entre janeiro de 1999 e julho de 2001. Destas, 289 exames foram solicitadas em casos de catarata densa (total) pela impossibilidade de observar o segmento posterior. Os achados ultra-sonográficos foram documentados por fotografias e revisados para o estudo. Seguimento pós-operatório foi possível em 131 pacientes para avaliar sensibilidade e especificidade do ultra-som como método diagnóstico. A análise estatística foi feita com o teste t de "Student" usando o pacote estatístico SPSS "Statistical Package for the Social Science" 8.0 para Windows. Resultados: Foram estudados 289 pacientes com catarata densa, todos avaliados com ultra-som; 200 destes apresentavam alterações ecográficas em segmento posterior. Nos pacientes sem história de trauma ocular (n=268), 82 olhos (30,6%) apresentaram segmento posterior normal e 26 olhos (9,7%), descolamento de retina. Nos pacientes com história de trauma ocular (n=21) foram encontrados 8 olhos com descolamento de retina (38,1%) e 7 normais (33,3%). A concordância entre os achados ecográficos e pós-operatórios foi de 95,4% nos 131 pacientes com seguimento pós-operatório. O ultra-som apresentou sensibilidade de 91,3% e especificidade de 100%. Conclusão: Neste estudo, a avaliação pré-operatória de cataratas densas com ultra-som se mostrou eficiente em diagnosticar alterações do segmento posterior. A sensibilidade e a especificidade deste exame complementar na amostra estudada confirmam a importância do ultra-som na avaliação pré-operatória de pacientes com cataratas densas.

    Resumo em Inglês:

    Purpose: To evaluate the prevalence and nature of intra-ocular abnormalities detected by conventional B-scan ultrasound in patients with dense cataracts and compare them to their postoperative findings. Methods: Retrospective chart review of 724 B-scan ultrasound studies performed between January 1999 and July 2001. Two hundred and eighty-nine of these exams were referred due to a dense cataract that obscured any view of the fundus. The ultrasound findings were documented by prints and revised for the study. Follow-up was obtained in 131 patients to evaluate sensibility and specificity of B-scan ultrasound as a diagnostic method. Statistical analysis was performed by Student's "t" test using SPSS (Statistical Package for the Social Science) 8.0 for Windows. Results: Two hundred and eighty-nine patients with dense cataracts were studied, all of them evaluated by B-scan ultrasound; 200 had abnormal examination. In patients without a history of ocular trauma (n=268), 82 eyes (30.6%) presented a normal posterior segment on ultrasound and 26 eyes (9.7%), retinal detachment. In patients with a prior history of ocular trauma (n=21), 8 eyes (38.1%) presented retinal detachment and 7 eyes (33.3%) were normal on ultrasound. The agreement between ultrasound findings and postoperative findings was 95.4% in the 131 patients followed after surgery. B-scan ultrasound presented sensitivity of 91.3% and specificity of 100%. Conclusion: Preoperative evaluation of eyes with dense cataracts using B-scan ultrasound has shown to be efficient in diagnosing posterior segment abnormalities in this study. The sensibility and specificity of this exam found in the studied group confirm the importance of B-scan ultrasound in the preoperative evaluation of patients with dense cataracts.
  • Achados fundoscópicos em crianças portadoras de anemia falciforme no estado do Rio Grande do Norte Artigos Originais

    Garcia, Carlos Alexandre de Amorim; Fernandes, Maria Zélia; Uchôa, Uchoandro Bezerra Costa; Cavalcante, Bruno de Morais; Uchôa, Raquel Araújo Costa

    Resumo em Português:

    Objetivos: Detectar os principais achados fundoscópicos em crianças portadoras de hemoglobinopatias falciformes. Métodos: Foram estudados 26 pacientes com hemoglobinopatias falciformes, no Serviço de Oftalmologia do Hospital Universitário Onofre Lopes, Natal, RN, que foram submetidos a protocolo de pesquisa pré-estabelecido. Os resultados foram avaliados estatisticamente pelo teste qui-quadrado. Resultados: A idade média foi de 10,6 anos, com acuidade visual igual ou melhor que 20/25 na maioria, excetuando-se 3 olhos, que apresentavam outras doenças associadas. O tipo mais freqüente foi o SS com 57,7% (15/26) dos casos, seguido pelos SC e SA com 15,4% (4/26) cada, e pelo S-Thal com 11,5% (3/26). A freqüência da retinopatia por células falciformes foi maior após os 10 anos de idade, sendo mais freqüente, em valores relativos, no tipo S-Thal (100% dos casos) e, em valores absolutos, no tipo SS (9 casos). Os dois achados mais comuns foram tortuosidade venosa (12/26) e "black sunburst" (7/26). Conclusões: Observamos que a incidência de retinopatia por células falciformes aumentou após os 10 anos de idade e não evidenciamos achados da doença proliferativa. Portanto, enfatizamos a necessidade do exame oftalmológico precoce nos portadores de anemia falciforme, como forma de prevenir futuras complicações oculares.

    Resumo em Inglês:

    Purpose: To point out the main fundoscopic findings in children with sickle cell trait hemoglobinopathies. Methods: We studied 26 patients with sickle cell hemoglobinopathies in the ophthalmological ward at the Hospital Universitário Onofre Lopes, Natal, RN. The patients were submitted to a research questionnaire and the results were statistically evaluated by the chi² test. Results: The average age was 10,6 years, with visual acuity equal or better than 20/25 in the majority, except for three eyes which presented other associated pathologies. The most frequent type was SS in 57.7% (15/26) of cases, followed by SC e SA in 15.4% (4/26) each, and by S-Thal in 11.5% (3/26). The frequency of sickle cell retinopathy was higher after 10 years of age, being more frequent, in relative values, in type S-Thal (100%) and, in absolute values, in type SS (9 cases). The two most common findings were venous tortuosity (12/26) and "black sunburst" (7/26). Conclusion: We observed that the incidence of retinopathy in sickle cell increased with age over 10 years and no evidence of proliferative disease was found. Therefore, we emphasize the need for early ophthalmological examination in carriers of sickle cell disease as a form of preventing future complications.
  • Glaucoma de pressão normal e espessura corneana central Artigos Originais

    Sakata, Kenji; Selonke, Ian; Schmitt, Artur; Grandinetti, Alexandre; Sakata, Viviane; Guerra, Daniel R.; Sakata, Lisandro

    Resumo em Português:

    Objetivo: Este estudo tem como objetivo investigar a existência de diferença da espessura corneana central (ECC) em pacientes com glaucoma de pressão normal (GPN), glaucoma crônico simples (GCS) e pacientes normais (Controle). Métodos: Foram avaliados 113 pacientes dos quais 40 apresentavam GPN, 51 eram normais (Controles) e 22 apresentavam GCS. Todos os pacientes foram submetidos a exame oftalmológico completo e tiveram aferidas sua Po (Goldmann) e ECC (Topcon SP-2000P). Resultados: A média da espessura corneana central (ECC) dos pacientes com GPN foi de 500,95 µ (d.p. 28,65 µ), o grupo controle teve média de 521,11 µ (d.p. de 43,30 µ) e o grupo de GCS apresentou média de 522,23 µ (d.p. de 27,87 µ.). O grupo de GPN apresentou uma ECC significativamente menor quando comparado com os grupo controle (p = 0,01) e GCS (p=0,006). Entre os grupos controle e GCS não houve diferença estatística significativa (p = 0,91). Conclusão: Observou-se que numa amostra da população brasileira a ECC dos olhos com GPN é significativamente menor do que a ECC dos pacientes com GCS e do grupo controle.

    Resumo em Inglês:

    Purpose: To determine if there is a significant difference in central corneal thickness (CCT) among patients with normal tension glaucoma (NTG), primary open angle glaucoma (POAG) and normal patients. Methods: One hundred and thirteen patients were evaluated; 40 had NTG, 51 were normal and 22 had POAG. IOP (Goldmann) and CCT (Topcon SP-2000P) were measured in all patients. Results: The CCT mean in NTG patients was 500.95 µ (SD = 28.65µ); in normal patients the CCT mean was 521.11µ (SD = 43.30µ); and in the POAG group the CCT mean was 522.23µ (SD = 27.87µ). By statistical analysis (ANOVA, 95% confidence interval) the CCT in NTG was significantly lower than in normal patients and in the POAG group (p= 0.01 and p=0.006), but no differences was found between normal patients and the POAG group (p= 0.91). Conclusions: In this study we concluded that in a Brazilian population sample the NTG patients tend to present significantly lower ECC measurements when compared with normal and POAG patients.
  • Anomalias oculares e características genéticas na síndrome de Marfan Artigos Originais

    Sallum, Juliana Maria Ferraz; Chen, Jane; Perez, Ana Beatriz Alvarez

    Resumo em Português:

    Objetivo: Para se identificar as alterações oculares presentes na síndrome de Marfan, este trabalho apresenta a avaliação oftalmológica de 46 indivíduos portadores desta doença. Métodos: Estudo prospectivo com avaliação clínica de 46 pacientes portadores de síndrome de Marfan com avaliação oftalmológica completa. Dezessete pacientes também foram submetidos a exame genético clínico e estudo molecular. Resultados: Dos quarenta e seis pacientes incluídos neste estudo, as seguintes alterações oculares foram encontradas com maior freqüência: subluxação do cristalino (67,3%), hipoplasia de íris (23,9%), descolamento de retina (7,6%), córnea plana (2,2%), megalocórnea (2,2%) e miopia ou astigmatismo miópico (34,8%). Cinco pacientes (10,9%) apresentaram exame ocular normal em ambos os olhos. Detectou-se uma mutação patogênica distinta das relatadas na literatura em uma paciente, uma mutação de sentido trocado que ocorreu no éxon 28 levando à mudança de aminoácido C1166Y. Conclusões: As alterações oculares da síndrome de Marfan são freqüentes e o conhecimento do gene responsável FBN-1 e de sua expressão no olho auxiliam para o diagnóstico e tratamento destas anomalias.

    Resumo em Inglês:

    Purpose: To identify the ocular abnormalities in Marfan´s syndrome patients. Methods: Prospective study of 46 Marfan patients with complete ophthalmologic evaluation. Seventeen patients also underwent a clinical genetic and molecular analysis. Results: Among the 46 patients included in this study, the following ocular abnormalities were found more frequently: ectopia lentis (67.3%), hypoplastic irides (67.3%), retinal detachment (7.6%), flattened cornea (2.2%), megalocornea (2.2%) and myopia (34.8%). Five patients (10.9%) presented normal ocular evaluation in both eyes. A pathogenic mutation different from those published in other studies was found in one patient. Conclusions: Ocular abnormalities in Marfan´s syndrome are frequent. The better understanding of the FBN-1 gene and its expression in the eye are very helpful tools for the diagnosis and treatment of the abnormalitites.
  • Um programa baseado na triagem visual de recém-nascidos em maternidades: Fundação Altino Ventura/2000 Artigos Originais

    Ventura, Liana Maria de O.; Travassos, Simone; Ventura, Antonio Guilherme; Trigueiro, Luiz; Marques, Sergio

    Resumo em Português:

    Objetivo: Apresentar os dados obtidos de programa baseado na triagem visual de recém-nascidos, realizado em três maternidades públicas de referência do estado de Pernambuco, Brasil. Métodos: O projeto foi desenvolvido de forma prospectiva seguindo protocolo e organograma previamente elaborados. Para a sua execução contou-se com equipe multidisciplinar composta de 37 profissionais. Realizou-se a capacitação da equipe envolvida no projeto e ministrou-se palestras em cada maternidade, para os oftalmologistas, diretores, pediatras, neonatologistas, obstetras e enfermeiras. Os exames oftalmológicos foram realizados nas próprias maternidades públicas, com encaminhamento e tratamento dos casos de maior complexidade na sede da Fundação Altino Ventura. Pesquisou-se a flora conjuntival do recém-nascido e a vaginal materna, em 25 casos. Resultados: Capacitaram-se 20 oftalmologistas para o exame dos recém-nascidos. Examinaram-se 3.280 recém-nascidos (1.601 femininos e 1.679 masculinos). Foi detectado alguma anormalidade ocular ou fatores de risco em 701 casos (21,4%). A anormalidade ocular mais freqüente foi a hemorragia retiniana, vista em 255 casos (7,8%). O fator de risco para doença ocular de maior prevalência foi a retinopatia da prematuridade, detectada em 325 casos (9,9%), que foram encaminhados ao serviço especializado. Dos casos encaminhados, compareceram 65 pacientes (20,0%), e destes, em 15 casos (23,1%) havia algum grau de retinopatia da prematuridade. Na pesquisa, quanto à flora conjuntival do recém-nascido (50 olhos), 13 olhos (26,0%) apresentaram pelo menos um microrganismo. Em 18 casos de mães com cultura vaginal positiva para Staphylococcus epidermides, 10 (40,0%) apresentaram filho com a mesma bactéria em um ou ambos os olhos. Conclusões: Os autores enfatizam o pioneirismo do projeto, ressalvando que possibilitou maior interação entre oftalmologistas e profissionais de áreas afins, treinamento de oftalmologistas para o exame ocular nos recém-nascidos, permitindo a obtenção de importantes informações quanto às morbidades oculares da região, promovendo o adequado tratamento e seguimento dos casos indicados em idade precoce.

    Resumo em Inglês:

    Purpose: To report the data obtained through a project based on visual screening of newborns from three reference public maternities of Pernambuco state, Brazil. Methods: This investigation was a prospective study, according to a previously elaborated protocol and organogram. A multidisciplinary team of 37 professionals was involved. This team was trained and conferences were given to ophthalmologists, directors, pediatricians, neonatologists, obstetricians and nurses of each service. Ocular exams were performed in the selected maternity hospitals. The highly complex cases were referred to the Altino Ventura Foundation. Search for conjunctival flora in neonates and vaginal flora in their mothers was performed in 25 cases. Results: Twenty ophthalmologists were trained to perform ocular examination in newborns. Visual screening was conducted in 3,280 of them (1,601 females and 1,679 males). Ocular abnormalities or risk factors were found in 701 cases (21.4%). Retinal hemorrhage was the most frequent ocular abnormality seen in 255 cases (7.8%). The more prevalent risk factor for eye disease was retinopathy of prematurity found in 325 cases (9.9%). These patients were referred to specialized services. Of these 65 (20.0%) were examined and 15 (23.1%) had some stage of retinopathy of prematurity. The examination of the conjunctival flora of the newborns (50 eyes) showed at least one microorganism in 13 eyes (26.0%). Babies of 18 mothers with positive vaginal culture for Staphylococcus epidermis 10 (40.0%) had the same bacterium in one or both eyes. Conclusions: The authors emphasize that this was a pioneer project and that it provided a greater interaction among ophthalmologists and other health professionals, ophthalmic training in performing eye examination in newborns, allowing a better knowledge of ocular morbidity in the region, providing adequate treatment and follow up of the cases at an earlier age.
  • Conhecimento e atitude da população do Hospital São Paulo sobre doação de córneas Artigos Originais

    Rodrigues, Adriana Maria; Sato, Elcio Hideo

    Resumo em Português:

    Objetivo: O presente estudo teve por objetivo analisar o conhecimento e atitude da população em geral sobre transplante de córneas e, desta forma, tentar identificar as principais deficiências e barreiras para o aumento do número de doações. Métodos: Foi aplicado questionário a 321 pessoas que transitavam pelo Hospital São Paulo, centro de referência da cidade de São Paulo. Resultados: Do total de pessoas questionadas, 79,4% diziam-se doadoras de córneas e 20,6%, não. O principal motivo encontrado da não-doação foi o medo referente à venda de órgão e incerteza de receber o tratamento adequado à medida que se considera um doador em potencial. Foi encontrada uma diferença estatisticamente significante entre o conhecimento sobre transplante de córnea e o fato de dizer-se doador. Conclusão: Concluímos que melhoria na informação da população em geral é fator decisivo para aumentar a demanda de doadores.

    Resumo em Inglês:

    Purpose: To analyze the knowledge and attitude of the general population in order to identify the main deficiencies and to suggest measures to increase the number of cornea donations by the general population. Methods: Study through questionnaire polls answered by 321 people at the São Paulo Hospital. Results: Among the general population, 79.4% said to be cornea donors. The reason for the other 20.6% not to be donors was fear of trade of organ and not to receive proper treatment by the medical staff for being a potential donor. There was a statistically significant difference of knowledge about transplantation between those who said to be donors and those who did not. Conclusion: The authors concluded that better information on corneal transplantation for the general population would be of great help in increasing the number of cornea donations.
  • Comparação a longo prazo entre a facectomia extracapsular combinada à trabeculectomia e à facotrabeculectomia Artigos Originais

    Mandia Jr., Carmo; Kasahara, Niro; Seixas, Francisco Soares; Paolera, Maurício Della; Almeida, Geraldo Vicente de; Cohen, Ralph

    Resumo em Português:

    Objetivo: Comparar os resultados a longo prazo entre a cirurgia extracapsular da catarata combinada à trabeculectomia (FEC/TREC) e a facotrabeculectomia (FACO/TREC). Métodos: Os prontuários de 46 pacientes (53 olhos) submetidos à cirurgia combinada na Santa Casa de São Paulo entre janeiro de 1996 e novembro de 1999 foram revisados; dados relativos à pressão ocular (PO), acuidade visual (AV) e número de medicações foram analisados. Resultados: Em ambos os grupos, após seguimento médio de 18 meses, a acuidade visual melhorou e a pressão ocular diminuiu em relação aos valores pré-operatórios (P<0,05); 55,5% no grupo da facotrabeculectomia e 46,1% no grupo da catarata combinada à trabeculectomia obtiveram a pressão ocular final menor que 22 mmHg sem medicação (P=0,3). Conclusão: Ambas as técnicas são eficazes no tratamento simultâneo do glaucoma e da catarata. Entretanto, a facotrabeculectomia parece promover pressão ocular menor sem a necessidade do uso de medicações hipotensoras oculares em maior número de pacientes.

    Resumo em Inglês:

    Purpose: To compare the safety and efficacy of extracapsular cataract extraction (ECCE) combined with trabeculectomy and combined phacoemulsification/trabeculectomy. Methods: The records of 46 patients (53 eyes) who underwent combined glaucoma and cataract surgery at the Santa Casa de São Paulo between January 1996 and November 1999 were reviewed. Results: After a mean follow-up of 18 months, visual acuity improved and intraocular pressure decreased in both groups after surgery (P<0.05). In the phacofiltration group 55.5% of eyes achieved intraocular pressure < 22 mmHg without medication as compared to 46.1% in the extracapsular cataract extraction/trabeculectomy group (P=0.3). Conclusion: Both techniques proved to be safe and efficacious in the treatment of glaucoma and cataract. However, the phacofiltration surgery seems to promote lower intraocular pressure without additional medication in a larger number of eyes.
  • Avaliação da toxicidade ocular por derivados da 4-aminoquinolona Artigos Originais

    Goldhardt, Raquel; Corrêa, Zélia Maria da Silva; Eichenberg, Maria Cláudia; Marcon, Ítalo Mundialino; Vaccaro Filho, Antônio

    Resumo em Português:

    Objetivo: Avaliar a associação entre altas dosagens de derivados da 4-aminoquinolona com alterações na acuidade visual, fundo de olho e campo visual. Métodos: Estudo prospectivo de 86 pacientes em uso de cloroquina ou hidroxicloroquina (Plaquinol<FONT FACE=Symbol>â</FONT>) cuja visita inicial consistiu do exame da acuidade visual, biomicroscopia do segmento anterior do olho, oftalmoscopia binocular indireta, campimetria computadorizada (estímulo vermelho, programa 10.2-central), cálculo da dose diária e dose cumulativa usada pelo paciente. Consideradas doses cumulativas tóxicas de cloroquina <FONT FACE=Symbol>³</FONT>100 g e hidroxicloroquina (Plaquinol<FONT FACE=Symbol>â</FONT>) <FONT FACE=Symbol>³</FONT>300 g. Resultados: Todos os 86 pacientes examinados eram mulheres, média de idade = 45,08 anos (DP=14,63), usando cloroquina (n=13) ou hidroxicloroquina (n=73). Verificou-se uma associação entre a exposição às drogas e a baixa da visão com significância estatística (p=0,05) e risco relativo=0,3 (IC=0,1-1,1). À fundoscopia, nenhum paciente usuário de cloroquina (dose não tóxica) apresentou alteração macular e 41,7% (n=5) daqueles com doses tóxicas apresentaram alterações. No grupo da hidroxicloroquina, 21,8% (n=13) apresentaram alterações fundoscópicas com doses não tóxicas, e 17,6% (n=3) com doses tóxicas. Comparando pacientes com alterações campimétricas e aqueles sem alterações nos grupos usando cloroquina (p=0,423) e hidroxicloroquina (p=0,999), não houve diferença estatisticamente significativa entre alteração de campo visual e dose tóxica da droga. Conclusão: A perda visual maior ocorreu nos usuários de cloroquina. Esse dado ressalta a importância da medida da acuidade visual na avaliação e acompanhamento de pacientes em uso dos derivados da 4-aminoquinolona. Não foi observada diferença significativa entre os usuários de altas e baixas doses dos derivados da 4-aminoquinolona que apresentaram alteração de campo visual.

    Resumo em Inglês:

    Purpose: To evaluate the association between high doses of 4-aminoquinolone derivatives and loss of visual acuity, visual field defects, and fundus changes. Methods: Prospective study of 86 patients in use of chloroquine or hydroxychloroquine (Plaquinol<FONT FACE=Symbol>â</FONT>) whose initial visit consisted of visual acuity testing, anterior segment slit lamp examination, indirect ophthalmoscopy, computerized perimetry (red stimulus, program 10.2-central), calculation of the daily and cumulative dose used. Cumulative toxic doses were considered <FONT FACE=Symbol>³</FONT>100 g for chloroquine and <FONT FACE=Symbol>³</FONT>300 g for hydroxychloroquine. Results: All examined eighty-six patients were women, the average age was 45.08 years in use of chloroquine (n=13) or hydroxychloroquine (n=73) (Plaquinol<FONT FACE=Symbol>â</FONT>). There was a marked correlation between the use of medication and decrease in vision (p=0.05) with a relative risk of 0.3 (CI 95% 0.1-1.1). Slit lamp examination of the anterior segment was unremarkable in all patients. Fundus examination of chloroquine patients taking nontoxic doses failed to reveal any abnormalities and 41.7% (n=5) of the patients using toxic doses had fundus abnormalities. In the hydroxychloroquine group, 21.8% (n=13) had fundus abnormalities while using nontoxic doses and only 17.6% (n=3) using toxic doses presented fundus abnormalities. Comparing the patients with and without visual field defect in the chloroquine group (p=0.423) and hydroxychloroquine group (p=0.999), there was no statistical difference between the visual field defect and the drug dosage. Conclusion: Loss of vision was greater in chloroquine patients. This information is relevant to stress the importance of visual acuity testing to follow-up patients treated with 4-aminoquinolone derivatives. The presence of visual field defects was not statistically different between patients on high or low doses of 4-aminoquinolone derivates.
  • O perfil oftalmológico dos candidatos à carteira de motorista na cidade de Pelotas - RS Artigos Originais

    Duarte, Wladimir Ribeiro; Duarte, Maria Claudete Ribeiro; Paranhos, Carla; Bocaccio, Jussara Ribeiro Duarte; Bocaccio, Francisco José Lima; Sousa, Guaraciaba Ribeiro Duarte; Duarte, Márcia Ribeiro

    Resumo em Português:

    Objetivo: Estudar a acuidade visual dos candidatos a condutores de veículos da cidade de Pelotas e sua associação com as características sociodemográficas dos candidatos. Métodos: Foram examinados 1.010 candidatos a condutores em um serviço médico autorizado pelo Detran. Avaliou-se a acuidade visual, com e sem correção, bem como a sua relação com a visão de cores, sexo, idade e profissão dos entrevistados, por meio da análise de freqüências e de teste para associação. Resultados: Deste contingente 73,0% eram do sexo masculino, 65,0% tinham idade entre 18 e 45 anos, 51,4% ocupavam o setor de serviços e 25,0% utilizavam meio de correção visual. Sob o ponto de vista oftalmológico, 0,5% dos entrevistados não poderiam dirigir veículos automotores e 4,7% só poderiam obter habilitação para condução veicular, nas categorias A e B. Mostrou-se associada à acuidade visual baixa a maior longevidade. Conclusão: Baseado nos resultados, sugere-se menor intervalo de tempo para reavaliação visual dos motoristas das categorias C, D e E.

    Resumo em Inglês:

    Purpose: To study visual acuity of the candidates for driving licences in the city of Pelotas and its relationship with sociodemographic characteristics of the candidates. Methods: One thousand and ten candidates for driving license were examined in a Detran approved medical service. To check the social, demographic and visual characteristics of candidates, visual acuity, with or without correction, as well as its relation to color, gender, age and profession of the interviewed persons was evaluated, through analysis of frequencies and association. Results: In this study 72.5% were males, 33.8% were between 18 and 45 years old, 52.0% were in the service sector and 25.4% used some instrument of visual correction, 0.5% of the interviewed from the ophthalmological viewpoint, would not be able to drive automotor vehicles and 4.7% should only would get a driving license in the A and B categories. A low visual acuity has been associated with a higher longevity. Conclusion: Based on the results, a shorter time period for visual reavaluation of the C, D and E categories drivers is suggest.
  • Falência primária pós-transplante de córnea em serviço universitário Artigos Originais

    Hirai, Flávio Eduardo; Klatte, Stefan; Pacini, Keila Mattos; Sato, Elcio Hideo

    Resumo em Português:

    Objetivo: Analisar os possíveis fatores relacionados à falência primária pós-transplante de córnea no Setor de Doenças Externas Oculares e Córnea da Universidade Federal de São Paulo. Métodos: Realizado estudo retrospectivo de 239 pacientes submetidos à ceratoplastia penetrante no período de julho de 1999 a março de 2001. Casos de falência primária foram selecionados (grupo I) e dados dos doadores foram comparados com doadores de pacientes submetidos ao procedimento cirúrgico no mesmo período (grupo II). Os dados sobre os doadores foram: idade, causa mortis, contagem de células endoteliais, tempo entre óbito e a enucleação (T1), tempo entre a enucleação e a preservação da córnea (T2) e o tempo de preservação do tecido até a cirurgia (T3). Resultados: Foram analisados dados de 164 pacientes, sendo 21 casos de falência primária (12,8%). A média de idade dos doadores do grupo I foi de 43,1 anos (±22,0) e no grupo II foi de 47,9 anos (±18,9). Não houve diferença estatística entre os diferentes intervalos de tempo (T1, T2, T3). As principais causas de morte foram trauma, câncer e doenças cardíacas. Conclusão: Os diversos fatores analisados no presente estudo não apresentaram diferenças estatisticamente significantes entre os dois grupos estudados. Dificuldades em determinar as causas exatas da falência primária de um botão corneano pós-transplante sugerem uma multifatoriedade envolvida na gênese desta entidade. O trabalho das equipes dos Bancos de Olhos e a notificação, por parte dos médicos, das complicações ocorridas no pós-operatório contribuem na diminuição da incidência das falências pós-transplante de córnea.

    Resumo em Inglês:

    Purpose: To analyze the factors related to primary corneal graft failure after penetrating keratoplasty in the Corneal and External Diseases Section of the Federal University of São Paulo, Brazil. Methods: A retrospective study was performed using the charts of patients submitted to penetrating keratoplasty from July 1999 to March 2001. Cases of primary failure (group I) and patients submitted to the surgical procedure at the same period (group II) were selected and compared. Information collected from donors were age, cause of death, endothelial cell count, time between death and enucleation (T1), time between enucleation and preservation of the graft (T2) and time of tissue preservation until surgery (T3). Results: 164 patients were analyzed with 21 cases of primary failure (12.8%). The mean age of the donors of group I was 43.1 years (±22.0) and from group II was 47.9 years (±18.9). There was no statistical difference between the two groups considering the time intervals (T1, T2, T3). Causes of death included trauma, cancer and heart diseases. Conclusion: Differences in all analyzed factors were not significant between both groups. The difficulties in determining the causes of primary corneal graft failure suggests a multifactorial process involved in this problem. Well-trained Eye Bank staff and notifications about postoperative complications are important to decrease the primary failure incidence.
  • Prevalência de acuidade visual reduzida nos alunos da primeira série do ensino fundamental das redes pública estadual e privada de Londrina-PR, no ano de 2000 Artigos Originais

    Lopes, Gerson Jorge Aparecido; Casella, Antônio Marcelo Barbante; Chuí, Cristiane Assami

    Resumo em Português:

    Objetivos: Verificar a prevalência de acuidade visual reduzida em estudantes da 1ª série do ensino fundamental das redes pública estadual e privada de Londrina -- PR, zona urbana; comparar essas prevalências; verificar e comparar a prevalência de escolares utilizando correção óptica por ocasião do teste de acuidade visual e descrever as causas da acuidade visual reduzida nessa população. Métodos: Teste de acuidade visual foi realizado em 1688 alunos das escolas públicas estaduais e 611 alunos das escolas privadas. As crianças com acuidade visual menor ou igual a 0,7 foram encaminhadas para exame oftalmológico. Resultados: A prevalência de acuidade visual reduzida foi de 17,1% na rede pública estadual e 19,8% na rede privada, cuja diferença não tem significância estatística. A prevalência de escolares usando óculos foi de 2,4% na rede estadual e de 3,6% na rede privada; sem diferença estatisticamente significativa entre estes resultados. As causas de acuidade visual reduzida foram erro refracional, ambliopia, estrabismo e outras causas. Conclusão: A prevalência de acuidade visual reduzida entre escolares das redes pública estadual e privada foi estatisticamente igual, bem como a prevalência de escolares utilizando correção óptica. As causas de acuidade visual reduzida foram erro refracional, ambliopia, estrabismo, afacia por catarata congênita, catarata congênita zonular, persistência de vítreo primário hiperplásico, palidez do nervo óptico e alteração macular.

    Resumo em Inglês:

    Purpose: To analyze the prevalence of reduced visual acuity in students of elementary state public and private schools of Londrina's urban area; to compare the prevalence of reduced visual acuity in children of state public and private schools; to analyze and compare the prevalence of children wearing eye-glasses, and to describe the causes of reduced vision in this population. Methods: The visual acuity test was performed in 1688 school children of state public schools and in 611 school children of private schools. The children with visual acuity 0.7 or worse in one of the eyes were directed to a ophthalmic examination. Results: The reduced visual acuity prevalence in school children was 17.1% in state public schools, and 19.8% in private schools; this difference does not have statistical significance. The prevalence of children wearing eyeglasses was 2.4% in state public schools and 3.6% in private schools, without statistical significance between these results. The causes of reduced visual acuity were refractive errors, amblyopia, strabismus and other causes. Conclusion: The prevalence of reduced visual acuity in students of elementary state public and private schools was statistically the same, as well as the prevalence of children wearing eyeglasses. The causes of reduced visual acuity were refractive errors, amblyopia, strabismus, congenital cataract aphakia, zonular congenital cataract, persistent of the hyperplastic primary vitreous, optic nerve atrophy and macular disorder.
  • Rubeosis capsulare: um caso incomum de rubeosis iridis em paciente com implante de lente intra-ocular - Relato de caso Relatos De Casos

    Rosa, Alexandre A. Marques; Souza, Eduardo Cunha de; Barth, Breno; Nosé, Walton

    Resumo em Português:

    Os autores relatam o caso raro de paciente diabético com rubeosis iridis submetido à cirurgia de catarata com implante de lente intra-ocular, em que houve o crescimento de neovasos na cápsula posterior do cristalino.

    Resumo em Inglês:

    The authors report a rare case of a diabetic patient with rubeosis iridis who had cataract extraction with intraocular lens implantation, in whom neovascularization developed within the posterior lens capsule.
  • Doença de Oguchi: relato de caso e revisão bibliográfica Relatos De Casos

    Goulart, Dario Grechi; Myai, Cleide; Atique, Denise; Takahashi, Walter Yukihiko; Aihara, Teruo

    Resumo em Português:

    Relatamos o caso de uma paciente com sintomas de cegueira noturna congênita estacionária (CNCE) no qual constatamos alterações oftalmoscópicas peculiares da doença de Oguchi, inédita, nos limites de nosso conhecimento, à consideração da literatura médica brasileira publicada. Observamos e documentamos as alterações clássicas desta doença e do seu importante comemorativo, o também infreqüente, fenômeno de Mizuo-Nakamura. O exame eletrorretinográfico (ERG) também mostrou sinais típicos. Acrescentamos, brevemente, revisão bibliográfica da doença.

    Resumo em Inglês:

    We herein describe a case of a patient whose only symptom was nyctalopia. Peculiar ophthalmoscopic findings of Oguchi's disease were observed. Classic changes in the electroretinogram (ERG) and Mizuo-Nakamura's phenomenon were also reported. To the best of our knowledge, there isn't another occurrence in our published literature. A brief bibliographic review is added.
  • Envolvimento orbital bilateral na doença de Erdheim-Chester: relato de caso

    Monteiro, Mário Luiz Ribeiro; Sampaio, César Moreira

    Resumo em Português:

    Objetivo: Relatar um caso de doença de Erdheim-Chester com envolvimento orbital bilateral e informar os oftalmologistas a respeito dessa condição incomum. Métodos: Relato de caso. Paciente do sexo masculino, 41 anos de idade, apresentou com proptose, xantelasmas, edema do disco óptico e restrição dos músculos extraoculares. A suspeita diagnóstica era de linfoma com envolvimento sistêmico e já havia sido submetido à biópsia do retroperitônio, mas o diagnóstico ainda era inconclusivo. Resultados: O paciente foi submetido a exame de tomografia computadorizada e imagem por ressonância magnética da órbita. Foi feita a suspeita de pseudotumor orbitário e biópsia orbital foi realizada. Esta não revelou o diagnóstico correto que foi feito apenas após análise detalhada dos dados clínicos e de imagem e após revisão dos exames histopatológicos. O diagnóstico sistêmico só foi feito após o diagnóstico da afecção orbitária embora o paciente já estivesse sendo investigado do ponto de vista clínico por mais de um ano. Conclusão: A doença de Erdheim-Chester é condição sistêmica idiopática caracterizada por processo xantogranulomatoso envolvendo o retroperitônio, coração, pulmões, ossos e outros tecidos. A condição freqüentemente é fatal devido a complicações renais e cardiovasculares. Os achados oculares são incomuns e podem auxiliar no diagnóstico. Os oftalmologistas devem, portanto, conhecer as manifestações clínicas e os achados de imagem dessa doença e auxiliar no seu diagnóstico precoce.

    Resumo em Inglês:

    Purpose: To report a case of Erdheim-Chester disease with bilateral orbital involvement and to inform ophthalmologists about this uncommon condition. Methods: Case report. A 41-year-old man presented with proptosis, lid xanthelasmas, disc edema and extraocular muscle restrictions. He was suspected of having a systemic lymphoma and had already been submitted to a retroperitoneal biopsy, however, the diagnosis was still uncertain. Results: The patient was evaluated by computed tomography and magnetic resonance imaging of the orbit. Orbital pseudotumor was suspected and a biopsy of the orbital lesion initially failed to provide the correct diagnosis which was only made after detailed analysis of the clinical and imaging findings, and review of the histopathologic studies. The systemic diagnosis was made after the orbital diagnosis although the patient had been extensively investigated for more than one year. Conclusions: Erdheim-Chester disease is a rare idiopathic systemic condition characterized by a xanthogranulomatous process involving retroperitoneum, heart, lungs, bone and other tissues. The condition is often fatal due to renal or cardiovascular complications. Ocular findings are rare but may be very helpful for the diagnosis. Therefore, ophthalmologists should be aware of the clinical manifestations and imaging findings of this rare disease in order to establish an early diagnosis.
  • Frentes de ondas (wavefronts) e limites da visão humana Parte 1: fundamentos Atualização Continuada

    Jankov, Mirko; Mrochen, Michael; Schor, Paulo; Chamon, Wallace; Seiler, Theo

    Resumo em Português:

    A luz se propaga uniformemente a partir de um ponto luminoso na mesma velocidade em todas as direções. Sua posição em cada determinado momento é uma esfera formada juntando-se todos os pontos em uma mesma fase e tendo como centro a sua própria fonte. Tais superfícies esféricas imaginárias chamam-se frentes de luz ou frentes de ondas. Há três fatores limitadores de detalhes mais finos para o olho humano: óptico (por causa da dispersão, difração, aberração cromática e aberração monocromática), retínico e neural (limitação máxima de acuidade visual de aproximadamente 2,0 ou 20/10).Um sistema de equações matemáticas, polinômios de Zernike, pode definir superfícies geométricas para descrever aberrações ópticas monocromáticas, tanto as de baixa ordem ('prisma', 'esfera' e 'astigmatismo'), quanto às de alta ordem ('coma', 'aberração esférica' e outros). Medida das aberrações ópticas nos dá informação sobre o desempenho total de todos os elementos ópticos do olho em conjunto. Dois sistemas descritos aqui, o aberrômetro baseado no princípio de Tscherning e o originado do sensor Hartmann-Shack, têm a mesma lógica: comparar a posição atual das frentes de onda com a ideal, calcular matematicamente qual é a superfície geométrica que descreve essa discrepância e representá-la em termos de polinômios de Zernike. A topografia corneana computadorizada também pode, com "software" adequado, descrever as frentes de ondas definidas por irregularidades corneanas com polinômios de Zernike, porém tal caracterização representa somente a superfície anterior da córnea. Em conclusão, a tecnologia de frentes de ondas oferece nova maneira de quantificar e classificar os erros de imagem óptica do olho humano. O próximo artigo abordará as peculiaridades da análise de frentes de ondas, bem como algumas aplicações clínicas e cirúrgicas no dia-a-dia da prática oftalmológica.

    Resumo em Inglês:

    Light spreads out uniformly at the same speed in all directions. Its position at any given moment is a sphere that connects all the corresponding phase points, having the source at its center. Such imaginary spherical surfaces are called light fronts or wavefronts. There are three principal factors that limit the finest details an eye can see: optical (due to scattering, diffraction, chromatic and monochromatic aberration), retinal and neural factors (limiting visual acuity to an approximate maximum of 20/10 or 2.0). A mathematical system, the Zernike polynomials, can define geometrical surfaces in order to describe the monochromatic aberrations, both for the lower order aberrations ('prism', 'sphere' and 'astigmatism') and the higher order ones ('coma', 'spherical aberration' and others). The wavefront measures the performance of the whole optical system of the eye. Both systems described herein, the aberrometer based on the Tscherning principle and the one originated from the Hartmann-Shack sensor, start from the same logic: to compare the actual position of the wavefronts with the ideal one, calculate mathematically the geometrical surface that describes that discrepancy and represent it in the terms of the Zernike polynomials. Corneal topography measurement, with adequate software, can also express the wavefront, caused by the corneal irregularities, with the Zernike polynomials, but it still represents the anterior corneal surface only. Wavefront technology offers a new way to quantify and classify optical imaging errors of the human eye. The next article will deal with the peculiarities of the wavefront analysis, as well as with some of the clinical and surgical applications to the day-to-day ophthalmic practice.
  • Frentes de ondas (wavefronts) e limites da visão humana Parte 2: aplicações Atualização Continuada

    Jankov, Mirko; Mrochen, Michael; Schor, Paulo; Chamon, Wallace; Seiler, Theo

    Resumo em Português:

    Os valores médios de todos os coeficientes de Zernike são de aproximadamente zero, ao passo que a variabilidade individual é muito grande, o que significa que os seres humanos, como espécie em geral, têm sistema óptico muito bom, mas individualmente imperfeito. Certa instabilidade temporal das aberrações de alta ordem foi descrita em função da acomodação. Este fato leva a uma nova pergunta: a correção de todas as aberrações para visão em estado não acomodado será benéfica para visão de perto também? É possível modificar e diminuir as aberrações ópticas por meio de foto-ablação por "scanning spot LASER" tendo os dados das frentes de ondas como a base para perfil de ablação individualizado. É fundamental a fixação perfeita do feixe de "LASER" em relação ao olho, obtida com os "eye-trackers" de alta freqüência. O benefício visual teórico da correção das aberrações de alta ordem seria de até 12 vezes. A meta principal dos tratamentos guiados pelas frentes de onda é de não permitir a piora da visão depois do tratamento cirúrgico refrativo, como pode ocorrer hoje em dia com os tratamentos tradicionais a "LASER"; em seguida, a meta se es-tenderia aos melhoramentos visuais, bem como ao tratamento dos casos de córneas extremamente irregulares (ablações primárias irregulares, pequenas ou descentradas, a presença das ilhas centrais ou irregularidades após transplante de córnea). O entendimento da terminologia e das bases da nova evolução tecnológica, bem como o constante acompanhamento crítico dos resultados publicados é fundamental para a abordagem moderna dos problemas relativos à refração e à cirurgia refrativa.

    Resumo em Inglês:

    The mean values for all the Zernike coefficients are approximately zero, while the individual variability is very high, what means that humans as a species in general have a very good optical system, though individually imperfect. Some temporal instability of higher-order aberrations, whose largest source is accommodation has been described. There arises a new question: will the correction of all the aberrations for the non-accommodated state of the eye be as beneficial for the near sight also? It is possible to modify and decrease the optical aberrations by a process of photo-ablation carried out by a scanning spot LASER with the wavefront data serving as a basis for the customized ablation profile. Perfect alignment of the LASER beam on the eye by means of high frequency eye trackers is fundamental. The theoretical visual benefit by correcting the higher order aberrations is up to 12 times. The main goal of the wavefront-guided treatments is not to allow the decrease in visual acuity after refractive surgical treatments, as may occur nowadays with the traditional LASER treatments; the next step would be treatments aiming at the improvement of visual acuity, as well as the treatments of highly irregular corneas (primary irregular, small or decentered ablations, central islands or irregularities after corneal transplantation). Understanding the new terminology and the bases of the new technological evolution, together with the continuous and critical follow-up of the new results in the literature, is the key of success of the modern approach to the problems related to refraction and refractive surgery.
Conselho Brasileiro de Oftalmologia Rua Casa do Ator, 1117 - cj.21, 04546-004 São Paulo SP Brazil, Tel: 55 11 - 3266-4000, Fax: 55 11- 3171-0953 - São Paulo - SP - Brazil
E-mail: abo@cbo.com.br