Acessibilidade / Reportar erro
Arquivos Brasileiros de Oftalmologia, Volume: 83, Número: 4, Publicado: 2020
  • Rastreamento da retinopatia diabética e a pandemia COVID-19 no Brasil Editorial

    Malerbi, Fernando Korn; Morales, Paulo Henrique Avila; Regatieri, Caio Vinicius Saito
  • Efeito do comprimento axial ocular na espessura da camada de fibras nervosas da retina e da camada de células ganglionares-plexiforme interna avaliadas por OCT espectral Original Article

    Francisconi, Carolina Lampert Monte; Wagner, Mário Bernardes; Ribeiro, Roberto Vanin Pinto; Freitas, André Moraes

    Resumo em Português:

    RESUMO Objetivo: Avaliar a influência do comprimento axial ocular na espessura da camada de fibras nervosas da retina peripapilar e na espessura da camada de células ganglionares-plexiforme interna em olhos saudáveis após correção para efeito de magnificação ocular. Métodos: Neste estudo transversal, avaliamos 120 olhos de 60 participantes voluntários (míopes, emétropes e hipermétropes). A espessura da camada de fibras nervosas da retina peripapilar e da camada de células ganglionares-plexiforme interna foram medidas usando a tomografia de coerência óptica espectral (OCT)-Cirrus HD-OCT e correlacionada com o comprimento axial ocular. O ajuste para a magnificação ocular foi realizado aplicando a fórmula de Littmann. Resultados: Antes do ajuste para magnificação ocular, a análise de modelos mistos ajustada por idade demonstrou uma correlação negativa significante entre o comprimento axial e a espessura média da camada de fibras nervosas da retina peripapilar (r=-0,43; p<0,001), espessura da camada de fibras nervosas da retina peripapilar inferior (r=-0,46; p <0,001), espessura da camada de fibras nervosas da retina peripapilar superior (r=-0,31; p<0,05), espessura da camada de fibras nervosas da retina peripapilar nasal (r=-0,35; p<0,001) e espessura média das células ganglionares-plexiforme interna (r=-0,35; p<0,05). No entanto, após a correção do efeito de magnificação, os resultados foram consideravelmente diferentes, revelando apenas uma correlação positiva entre o comprimento axial e a espessura temporal da camada de fibras nervosas da retina(r=0,42; p<0,001). Além disso, demonstramos uma correlação positiva entre o comprimento axial e a espessura média das células ganglionares-plexiforme interna (r=0,48; p<0,001). Todas as outras correlações não foram consideradas estatisticamente significativas. Conclusão: Antes do ajuste para o efeito de magnificação ocular, o comprimento axial estava negativamente correlacionado com a espessura da camada de fibras nervosas da retina peripapilar e das células ganglionares-plexiforme interna medido pelo Cirrus-OCT. Atribuimos esse efeito à magnificação ocular associada a comprimentos axiais maiores, o que foi corrigido com a fórmula de Littman. Mais estudos são necessários para investigaro impactoda correçãoda magnificação ocular na acurácia diagnóstica do Cirrus-OCT.

    Resumo em Inglês:

    ABSTRACT Purpose: To evaluate the influence of ocular axial length on circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in healthy eyes after correcting for ocular magnification effect. Methods: In this cross-sectional study, we evaluated 120 eyes from 60 volunteer participants (myopes, emmetropes, and hyperopes). The thickness of the circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer were measured using the spectral optical coherence tomography (OCT)-Cirrus HD-OCT and correlated with ocular axial length. Adjustment for ocular magnification was performed by applying Littmann’s formula. Results: Before the adjustment for ocular magnification, age-adjusted mixed models analysis demonstrated a significant negative correlation between axial length and average circumpapillary retinal nerve fiber layer thickness (r=-0.43, p<0.001), inferior circumpapillary retinal nerve fiber layer thickness (r=-0.46, p<0.001), superior circumpapillary retinal nerve fiber layer thickness (r=-0.31, p<0.05), nasal circumpapillary retinal nerve fiber layer thickness (r=-0.35, p<0.001), and average ganglion cell-inner plexiform layer thickness (r=-0.35, p<0.05). However, after correcting for magnification effect, the results were considerably different, revealing only a positive correlation between axial length and temporal retinal nerve fiber layer thickness (r=0.42, p<0.001). Additionally, we demonstrated a positive correlation between axial length and average ganglion cell-inner plexiform layer thickness (r=0.48, p<0.001). All other correlations were not found to be statistically significant. Conclusions: Before adjustment for ocular magnification, axial length was negatively correlated with circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness measured by Cirrus-OCT. We attributed this effect to ocular magnification associated with greater axial lengths, which was corrected with the Littman’s formula. Further studies are required to investigate the impact of ocular magnification correction on the diagnostic accuracy of Cirrus-OCT.
  • Cross-linking corneano acelerado com riboflavina hiposmolar em córneas ceratocônicas finas: 2 anos de acompanhamento Original Article

    Ozek, Dilay; Karaca, Emine Esra; Kemer, Ozlem Evren

    Resumo em Português:

    RESUMO Objetivo: Este estudo foi realizado para avaliar os resultados do cross-linking corneano acelerado em córneas ceratocônicas com os valores mais baixos de paquimetria <400 µm. Métodos: O estudo incluiu 28 olhos de 24 pacientes. As acuidades visuais não corrigidas e melhor corrigidas (logMAR), leituras ceratométricas mais planas e íngremes, espessura corneana central no ponto mais fino, aberrações corneanas de mais alta ordem e a sensibilidade ao contraste foram avaliadas antes e em 1, 3, 6, 12 e 24 meses após a realização do do cross-linking. Resultados: A média da acuidade visual melhor corrigida e a sensibilidade ao contraste aumentaram (p=0,02, p=0,03, respectivamente), enquanto a média da acuidade visual não corrigida não diferiu significativamente (p>0,05) aos 24 meses após o cross-linking, comparada com medidas antes do procedimento. Embora a leitura da média da ceratometria mais plana não tenha apresentado alteração significativa (p=0,58), a leitura ceratométrica mais íngreme diminuiu quando comparada ao seu valor antes do cross-linking (p=0,001). Não foi observada alteração na média da espessura corneana central no ponto mais fino aos 24 meses após o cross-linking em comparação com seu valor antes do procedimento (p=0,12). Conclusão: O cross-linking corneano acelerado nos olhos ceratocônicos com córneas finas pode interromper a progressão do ceratocone nas córneas mais finas que 400 µm 24 meses após o tratamento.

    Resumo em Inglês:

    ABSTRACT Purpose: This study was performed to evaluate the outcomes of accelerated corneal cross-linking in keratoconic corneas with thinnest pachymetry values of <400 µm. Methods: The study included 28 eyes of 24 patients. The uncorrected and best-corrected visual acuities (logMAR), flattest and steepest keratometric readings, central corneal thickness at the thinnest point, corneal higher-order aberrations, and contrast sensitivity were assessed before and at 1, 3, 6, 12, and 24 months after corneal cross-linking. Result: The mean best-corrected visual acuity and contrast sensitivity increased (p=0.02, p=0.03, respectively), whereas the mean uncorrected visual acuity did not significantly differ (p>0.05) at 24 months after corneal cross-linking, compared with measurements before corneal cross-linking. Although the mean flattest keratometric reading showed no significant change (p=0.58), the mean steepest keratometric reading was reduced when compared with its value before corneal cross-linking (p=0.001). No change was observed in the mean central corneal thickness at the thinnest point at 24 months after corneal cross-linking, compared with its value before corneal cross-linking (p=0.12). Conclusion: Accelerated corneal cross-linking in keratoconic eyes with thin corneas could halt the progression of keratoconus in corneas thinner than 400 µm at 24 months after treatment.
  • Alterações nos parâmetros do segmento anterior após a inserção de implantes ExPRESS Mini para Glaucoma e após trabeculectomia Original Article

    Livny, Eitan; Hammel, Na’ama; Mimouni, Michael; Lusky, Moshe; Kaiserman, Igor; Bahar, Irit

    Resumo em Português:

    RESUMO Objetivo: Comparar as alterações nos parâmetros do segmento anterior após a cirurgia ExPRESS Mini Glaucoma Shunt vs. trabeculectomia usando a câmera Scheimpflug Pentacam rotativa. Métodos: Neste estudo comparativo prospectivo, 27 pacientes com glaucoma tratados no Centro Médico Rabin de 2009 a 2013 foram incluídos neste estudo comparativo prospectivo: 19 participantes (19 olhos) foram submetidos ao implante de derivação ExPRESS e 12 (13 olhos) foram submetidos à trabeculectomia. Alterações nos parâmetros da câmara anterior no dia 1 e em 3 meses de pós-operatório foram avaliadas pelas imagens de Scheimpflug. Resultados: A pressão intraocular diminuiu significativamente em relação aos valores iniciais nos dois grupos. A diminuição nos dois grupos foi semelhante no 3º mês pós-operatório (p=0,82). A cirurgia com ExPRESS causou um aumento temporário do astigmatismo posterior da córnea (p=0,008) e uma diminuição temporária da profundidade da câmara anterior (p=0,016) e do volume (p=0,006) no primeiro dia do pós-operatório. Ao final de três meses, esses parâmetros não foram mais estatisticamente significativos (p=0,065, p=0,51 e p=0,57, respectivamente). A trabeculectomia causou um aumento temporário do astigmatismo anterior e posterior da córnea no primeiro dia do pós-operatório (p=0,003 e p=0,005, respectivamente), mas isso não foi observado ao final de 3 meses (p=1,0 e p=1,0, respectivamente). Após 3 meses, tanto o EXPRESS quanto a trabeculectomia mostraram alterações semelhantes nos parâmetros da câmara anterior. Conclusões: O implante ExPRESS Mini para glaucoma e a trabeculectomia diminuíram significativamente a pressão intraocular e tiveram efeitos temporários nos parâmetros do segmento anterior, com pequenas diferenças entre os métodos.

    Resumo em Inglês:

    ABSTRACT Purpose: To compare changes in anterior segment parameters following ExPRESS Mini Glaucoma Shunt surgery vs. trabeculectomy using the Pentacam rotating Scheimpflug camera. Methods: In this prospective, comparative study, 27 patients with glaucoma treated at the Rabin Medical Center from 2009 to 2013 were enrolled in this prospective comparative study: 19 participants (19 eyes) underwent ExPRESS shunt implantation and 12 (13 eyes) underwent trabeculectomy. Changes in anterior chamber parameters at postoperative day 1 and postoperative month 3 were evaluated on Scheimpflug images. Results: Intraocular pressure decreased significantly from baseline in both groups. The decrease in both groups was similar at postoperative month 3 (p=0.82). ExPRESS surgery caused a transient increase in posterior corneal astigmatism (p=0.008) and a transient decrease in anterior chamber depth (p=0.016) and volume (p=0.006) on postoperative day 1. At postoperative month 3, these parameters were no longer statistically significant (p=0.65, p=0.51, and p=0.57 respectively). Trabeculectomy caused a transient increase in anterior and posterior corneal astigmatism on postoperative day 1 (p=0.003 and p=0.005, respectively), which were not evident at postoperative month 3 (p=1.0 and p=1.0, respectively). At postoperative month 3, both ExPRESS and trabeculectomy showed similar changes in anterior chamber parameters. Conclusions: Both ExPRESS mini glaucoma implant and trabeculectomy significantly decreased intraocular pressure and had transient effects on anterior segment parameters, with minor differences between the methods.
  • Efeitos da dilatação pupilar nos resultados da biometria óptica ocular em pacientes pediátricos Original Article

    Balsak, Selahattin

    Resumo em Português:

    RESUMO Objetivo: A dilatação pupilar farmacológica é realizada em exames oftalmológicos abrangentes e antes das medições biométricas. Até o momento, não há consenso sobre seu impacto nas medições biométricas. O objetivo deste estudo foi investigar os efeitos da dilatação pupilar nas medidas biométricas oculares em crianças saudáveis. Métodos: Estudo prospectivo, observacional e não randomizado de crianças (4-18 anos) que foram admitidas para exame oftalmológico de rotina. As medidas biométricas foram realizadas usando um dispositivo de biometria óptica sem contato, antes e após a dilatação pupilar farmacológica com cloridrato de ciclopentolato. Os cálculos de potência das lentes intraoculares foram realizados utilizando as fórmulas de Hill-RBF, Barrett, Olsen, Sanders-Retzlaff-Kraff/ Teórica, Holladay e Hoffer Q. Análises estatísticas descritivas também foram realizadas. O teste dos postos sinalizados de Wilcoxon foi usado para comparar as medidas antes e após a dilatação pupilar farmacológica. As relações entre as variáveis foram analisadas pelo coeficiente de correlação de Spearman-Brown. Resultados: O estudo incluiu 116 olhos de 58 crianças (idade média de 8,4 ± 0,32 anos; 34 meninas). Alterações significativas foram observadas após a dilatação pupilar, em termos de profundidade da câmara anterior, profundidade do humor aquoso e espessura central da córnea e do cristalino. Nenhuma mudança significativa ocorreu no comprimento axial. Os cálculos de potência da lente intraocular não revelaram alterações significativas após a dilatação pupilar na maioria das fórmulas, com exceção da fórmula Olsen. O poder da lente intraocular foi significativamente inversa correlacionada com o comprimento axial e a profundidade da câmara anterior. Conclusões: A dilatação pupilar farmacológica em crianças parece não ter impacto no comprimento axial e no poder da lente intraocular, mas causou um aumento significativo na profundidade da câmara anterior. A diferença nas medidas da profundidade da câmara anterior antes e após a dilatação pupilar pode estar relacionada ao modelo do dispositivo de biometria óptica utilizado. Tais resultados devem ser considerados nos cálculos de potência da lente intraocular realizados usando parâmetros de profundidade da câmara anterior.

    Resumo em Inglês:

    ABSTRACT Purpose: Pharmacological pupillary dilation is performed in comprehensive ophthalmological examinations and before biometric measurements. So far, there is no consensus regarding its impact on biometric measurements. This study’s aim was to investigate the effects of pharmacological pupillary dilation on ocular biometric measurements in healthy children. Methods: This was a prospective, observational, non-randomized study of children (4-18 years of age) who were admitted for routine ophthalmological examination. Biometric measurements were performed, using a non-contact optical biometry device, both before and after pharmacological pupillary dilation with cyclopentolate hydrochloride. Intraocular lens power calculations were performed using Hill-RBF, Barrett, Olsen, Sanders-Retzlaff-Kraff/Theoretical, Holladay, and Hoffer Q formulas. Descriptive statistical analyses were also performed. The Wilcoxon signed-rank test was used to compare measurements before and after pharmacological pupillary dilation. Relationships between variables were analyzed using the Spearman-Brown rank correlation coefficient. Results: The study included 116 eyes of 58 children (mean age, 8.4 ± 0.32 years; 34 girls). Significant changes were observed after pupillary dilation, compared with before pupillary dilation, in terms of anterior chamber depth, aqueous depth, and central corneal and lens thicknesses. No significant change was observed in axial length. Intraocular lens power calculations revealed no significant changes after pupillary dilation in most formulas except for the Olsen formula. The intraocular lens power was significantly inversely correlated with axial length and anterior chamber depth. Conclusions: Pharmacological pupillary dilation in children appeared to have no impact on axial length and intraocular lens power, but caused a significant increase in anterior chamber depth. The difference in anterior chamber depth measurements before and after pupillary dilation could be related to the optical biometry device model used. These outcomes should be considered in intraocular lens power calculations performed using anterior chamber depth parameters.
  • Uso de equipamento de realidade virtual para avaliar a destreza manual de candidatos a residência de oftalmologia Original Article

    Vieira, Ibraim Viana; Sakaya, Bruno Nogueira; Soares, Lucas Valadao de Brito; Chamon, Wallace

    Resumo em Português:

    RESUMO Objetivo: Avaliar os resultados da destreza da microcirurgia de duas avaliações sequenciais de treinamento usando a tecnologia de realidade virtual. Métodos: Estudo transversal multicêntrico em que todos os candidatos que foram aceitos como residentes de primeiro ano em uma de seis instituições de ensino de oftalmologia. Os residentes foram submetidos a duas séries idênticas de testes de destreza padronizados e reprodutíveis usando equipamento de realidade virtual (Eyesi®): “sequência 1” e “sequência 2”. Cada sequência consistiu em 5 níveis de dificuldade que foram avaliados usando um sistema de pontuação proprietário. Os dados foram testados quanto à normalidade utilizando o teste de Shapiro-Wilk. As diferenças entre os testes nas sequências 1 e 2 foram avaliadas com o teste de Wilcoxon signed-rank. Resultados: Os dados não seguiram uma distribuição normal. Houve melhora da sequência 1 em todos os testes (todos os valores de p<0,05). A soma de todas as pontuações (pontuação total) melhorou da sequência 1 (mediana= 152,50) para a sequência 2 (mediana= 256,00; p<0.001). Não houve correlação entre os valores da sequência delta e as pontuações médias. Conclusão: Duas avaliações sequenciais de treinamento utilizando a tecnologia de realidade virtual mostraram melhora relevante nas quantificações da destreza da microcirurgia. Essas informações devem ser consideradas se abordagens de realidade virtual forem utilizadas para fins de teste, pois a experiência prévia pode levar a melhores resultados.

    Resumo em Inglês:

    ABSTRACT Purpose: To assess the microsurgery dexterity outcomes of two sequential training evaluations using virtual reality technology. Methods: This was a multicenter cross-sectional study of all candidates who were accepted as first-year residents at one of six ophthalmology teaching institutions. Residents were subjected to two identical series of standardized, reproducible dexterity tests using virtual reality equipment (Eyesi®): “sequence 1” and “sequence 2.” Each sequence consisted of five difficulty levels that were assessed using a proprietary scoring system. The data were tested for normality using the Shapiro-Wilk test. The differences between tests in sequences 1 and 2 were evaluated using the Wilcoxon signed-rank test. Results: The data did not follow a normal distribution. There were improvements from sequence 1 in all the tests (all p values<0.05). The sum of all scores (total score) improved from sequence 1 (median= 152.50) to sequence 2 (median 256.00; p<0.001). There was no correlation between the delta sequence values and the average scores. Conclusion: Two sequential training evaluations using virtual reality technology showed relevant improvement in quantifications of microsurgery dexterity. This information should be considered if virtual reality approaches are used for testing purposes, as previous experience may lead to improved test results.
  • A utilidade de marcadores inflamatórios sistêmicos como indicadores diagnósticos da patogênese do edema macular diabético Original Article

    Ilhan, Cagri; Citirik, Mehmet; Uzel, Mehmet Murat; Kiziltoprak, Hasan; Tekin, Kemal

    Resumo em Português:

    RESUMO Objetivo: Investigar a utilidade de marcadores inflamatórios sistêmicos (ou seja, contagem de glóbulos brancos e plaquetas, volume médio de plaquetas e suas proporções) como marcadores de diagnóstico da patogênese do edema macular diabético. Métodos: A coorte do estudo incluiu 80 pacientes com edema macular diabético (40 com retinopatia diabética e 40 sem) e 40 controles saudáveis de acordo com a idade e sexo. As contagens de neutrófilos, linfócitos, monócitos, plaquetas e valores do volume plaquetário médio foram determinados a partir de amostras de sangue periféricdo, e as proporções de monócitos/linfócitos, plaquetas/linfócitos, volume plaquetário médio/linfócitos e neutrófilos/linfócitos foram calculadas e comparadas entre os grupos. Resultados: A proporção média de neutrófilos/linfócitos dos grupos com edema macular diabético e não-diabético foi maior que a do grupo controle, e o valor do grupo com edema macular diabético foi maior que o do grupo com edema macular não diabético (p<0,001 no com edema macular diabético vs. controle, p=0,04 no com edema macular não diabético vs. controle e p=0,03 no com edema macular diabético vs. o com edema macular não-diabético). Um valor de corte de neutrófilos/linfócitos ≥2,26 foi identificado como um indicador da patogênese do edema macular diabético com sensibilidade de 85% e especificidade de 74%. O volume plaquetário médio do grupo com edema macular diabético foi maior que o dos grupos com edema macular não-diabético e controle, enquanto os do grupo de edema macular não-diabético e controle foram semelhantes (edema macilar diabético vs. Edema macular não-diabético, p=0,08; com edema macular diabético vs. controle, p=0,02; e com edema macular não-diabético vs. controle, p=0,78). Todos os outros parâmetros foram semelhantes entre os grupos (todos p>0,05). Conclusão: A proporção de neutrófilos/linfócitos e o volume plaquetário médio do grupo com edema macular diabético foram superiores aos do grupo com edema macular não-diabético e controle. Um valor de corte da razão neutrófilos/linfócitos ≥2,26 foi identificado como um indicador da patogênese do edema macular diabético com alta sensibilidade e especificidade. Além disso, a proporção de neutrófilos/linfócitos do grupo com edema macular não-diabético foi superior à do grupo controle.

    Resumo em Inglês:

    ABSTRACT Purpose: To investigate the usefulness of systemic inflammatory markers [i.e., white blood cell and platelet counts, mean platelet volume, and their ratios] as diagnostic markers of the pathogenesis of diabetic macular edema. Methods: The study cohort included 80 diabetic macular edema patients (40 with diabetic retinopathy and 40 without) and 40 healthy age- and sex-matched controls. Neutrophil, lymphocyte, monocyte, and platelet counts, and the mean platelet volume were determined from peripheral blood samples, and the monocyte/lymphocyte, platelet/lymphocyte, and mean platelet volume/lymphocyte, and neutrophil/lymphocyte ratios were calculated and compared among groups. Results: The mean neutrophil/lymphocyte ratio of the diabetic macular edema and non-diabetic macular edema groups was higher than that of the control group, and the value of the diabetic macular edema group was higher than that of the non-diabetic macular edema group (p<0.001 in diabetic macular edema vs. control, p=0.04 in non-diabetic macular edema vs. control, and p=0.03 in diabetic macular edema vs. non-diabetic macular edema). A neutrophil/lymphocyte cutoff value of ≥2.26 was identified as an indicator of the pathogenesis of diabetic macular edema with a sensitivity of 85% and specificity of 74%. The mean platelet volume of the diabetic macular edema group was higher than those of the non-diabetic macular edema and control groups, while those of the non-diabetic macular edema and control groups were similar (diabetic macular edema vs. non-diabetic macular edema, p=0.08; diabetic macular edema vs. control, p=0.02; and non- diabetic macular edema vs. control, p=0.78). All other parameters were similar between groups (all p>0.05). Conclusion: The neutrophil/lymphocyte ratio and mean platelet volume of the diabetic macular edema group were higher than those of the non-diabetic macular edema and control groups. A neutrophil/lymphocyte ratio cutoff value of ≥2.26 was identified as an indicator of the pathogenesis of diabetic macular edema with high sensitivity and specificity. Moreover, the neutrophil/ lymphocyte ratio of the non-diabetic macular edema group was higher than that of the control group.
  • Efeito antifibrótico do Ácido Rosmarínico sobre os fibroblastos da Cápsula de Tenon estimulados com TGF-beta2: potencial terapêutico na cirurgia ocular Original Article

    Módulo, Carolina Maria; Ferreira, Larissa Domenegueti; Silva, Lilian Eslaine Costa Mendes da; Frade, Marco Andrey Cipriani; Reinach, Peter Sol; Rocha, Eduardo Melani; Paula, Jayter Silva

    Resumo em Português:

    RESUMO Objetivo: A deposição de colágeno e a diferenciação de miofibroblastos são fatores chaves relacionados à cicatrização excessiva em cirurgias oculares. Este estudo avaliou a atividade anti-fibrótica do ácido rosmarínico nos fibroblastos da cápsula de Tenon de coelhos estimulados com o fator de crescimento transformador-β2. Métodos: Culturas primárias de fibroblastos da cápsula de Tenon de coelhos foram tratadas com várias concentrações de ácido rosmarínico por 12h, na presença e na ausência do fator de crescimento transformador-β2. Após 48h, o índice de proliferação dos fibroblastos da cápsula de Tenon de coelhos e a diferenciação dos miofibroblastos foram investigados por coloração por imunofluorescência para proliferação de antígeno nuclear celular e α-actina de músculo liso, respectivamente. Um contador automático de células e um ensaio de atividade metabólica colorimétrica foram utilizados para avaliar o número e a viabilidade das células. A expressão e produção do colágeno foram determinadas por reação quantitativa em cadeia da polimerase em tempo real e ensaio de hidroxiprolina, respectivamente. Resultados: Fibroblastos da cápsula de Tenon de coelhos não estimulados tratados com qualquer concentração de ácido rosmarínico exibiram diminuição de colágeno (p<0,01), mas não mostraram diferenças no índice de proliferação. A exposição ao fator de crescimento transformador-β2 induziu a diferenciação de miofibroblastos e aumentou a produção de colágeno. A exposição ao ácido rosmarínico nas concentrações de 1,0 e 3,0 µM reduziu o índice de proliferação (p<0,02), bem como a expressão de colágeno e a quantificação de hidroxiprolina (p<0.05). A exposição a 3,0 µM de ácido rosmarínico reduziu a viabilidade (p=0,035) de fibroblastos da cápsula de Tenon de coelhos não estimulados e o número de células (p=0,001) em culturas de fibroblastos da cápsula de Tenon de coelhos estimuladas e não estimuladas. Conclusões: A exposição ao ácido rosmarínico 1,0 µM foi não citotóxica e levou à expressão reduzida de colágeno e menor proliferação de fibroblastos da cápsula de Tenon estimulados pelo fator de crescimento transformador-β2. Esses achados sugerem que o ácido rosmarínico é um composto antifibrótico relativamente não lesivo aos fibroblastos da cápsula de Tenon de coelhos, com potencial aplicação como agente adjuvante em procedimentos oculares, particularmente em cirurgias de glaucoma.

    Resumo em Inglês:

    ABSTRACT Purpose: Collagen deposition and myofibroblast differentiation are critical factors related to excessive scarring in ocular surgeries. This study evaluated the anti-fibrotic activity of rosmarinic acid on rabbit Tenon’s capsule fibroblasts stimulated with transforming growth factor- β2. Methods: Primary cultures of rabbit Tenon’s capsule fibroblasts were treated with various concentrations of rosmarinic acid for 12 h, in the presence and absence of transforming growth factor-β2. After 48 h, the proliferation index of rabbit Tenon’s capsule fibroblasts and the differentiation of myofibroblasts were investigated through immunofluorescence staining for proliferating cell nuclear antigen and alpha smooth muscle actin. An automated cell counter and colorimetric metabolic activity assay were used to evaluate cell number and viability. Collagen expression and production were determined by quantitative real-time polymerase chain reaction and hydroxyproline assay, respectively. Results: Unstimulated rabbit Tenon’s capsule fibroblasts treated with any concentration of rosmarinic acid exhibited diminished collagen expression (p<0.01) but showed no differences in proliferation index. Transforming growth factor-β2 exposure induced myofibroblast differentiation and increased collagen production. Exposure to rosmarinic acid at 1.0 and 3.0 µM concentrations reduced the proliferation index (p<0.02), as well as the collagen expression and hydroxyproline content (p<0.05). Exposure to 3.0 µM rosmarinic acid reduced viability (p=0.035) in unstimulated rabbit Tenon’s capsule fibroblasts and cell numbers (p=0.001) in both stimulated and unstimulated rabbit Tenon’s capsule fibroblast cultures. Conclusions: Exposure to 1.0 µM rosmarinic acid was noncytotoxic and led to reduced collagen expression and proliferation of stimulated rabbit Tenon’s capsule fibroblasts. These findings suggest that rosmarinic acid is a relatively non-injurious anti-fibrotic compound to rabbit Tenon’s capsule fibroblasts, with potential application as an adjunctive agent in ocular procedures, particularly in glaucoma surgeries.
  • Resultados clínicos da superfície ocular em pacientes tratados com reposição oral de vitamina D Original Article

    Karaca, Emine Esra; Kemer, Özlem Evren; Özek, Dilay; Berker, Dilek; Imga, Narin Nasiroglu

    Resumo em Português:

    RESUMO Objetivo: Analisar os resultados clínicos da superfície ocular em pacientes com deficiência de vitamina D após reposição oral. Métodos: Foram incluídos no estudo 40 pacientes com deficiência de vitamina D. Os pacientes receberam 50.000 unidades de vitamina D semanalmente por um período de oito semanas. Após esse período, 1.500-2.000 unidades/dia foram administradas por 24 semanas. Escores da margem palpebral, escores de expressibilidade da glândula meibomiana, classificação de Oxford, teste de Schirmer I, tempo de ruptura lacrimal, osmolaridade da lágrima e escore do Índice de Doenças da Superfície Ocular foram avaliados no início e após 8, 12 e 24 semanas. Resultados: O escore de expressibilidade da glândula meibomiana, Schirmer I, tempo de ruptura lacrimal, osmolaridade da lágrima e o Índice de Doenças da Superfície Ocular apresentaram melhoras após 8 semanas de suplementação de vitamina D (p<0,05). Comparado com os valores do pré-tratamento, o escore da margem palpebral e a classificação de Oxford diminuíram na 12ª semana (p<0,05). Conclusão: A reposição de vitamina D parece melhorar a superfície ocular em indivíduos com deficiência de vitamina D.

    Resumo em Inglês:

    ABSTRACT Purpose: To analyze the clinical outcomes of the ocular surface in patients with vitamin D deficiency after oral replacement. Methods: A total of 40 patients with vitamin D deficiency were enrolled in the study. The patients received 50,000 units of oral vitamin D weekly over a period of 8 weeks. After 8 weeks, 1,500-2,000 units/d were administered for 24 weeks. Eyelid margin score, meibomian gland expressibility score, Oxford grading, Schirmer I test, tear breakup time, tear osmolarity, and the Ocular Surface Disease Index score were evaluated at baseline, and at 8, 12, and 24 weeks. Results: The meibomian gland expressibility score, Schirmer I, tear breakup time, tear osmolarity, and Ocular Surface Disease Index score showed improvement 8 weeks after vitamin D supplementation (p<0.05). Compared with the pretreatment values, the eyelid margin score and Oxford grading were decreased at week 12 (p<0.05). Conclusion: Vitamin D replacement appears to improve ocular surface in individuals with vitamin D deficiency.
  • Atividade no humor aquoso da renina, angiotensina I e angiotensina II no glaucoma primário de ângulo aberto Original Article

    Seki, Valéria Batista Boreck; Souza, Guilherme Rabelo de; Messias, Andre; Casarini, Dulce Elena; Paula, Jayter Silva de

    Resumo em Português:

    RESUMO Objetivo: O sistema renina-angiotensina está envolvido na patogênese das condições isquêmicas retinianas e no glaucoma. Nosso objetivo foi avaliar a atividade da renina, enzima conversora de angiotensina 1 e 2 no humor aquoso, e amostras de sangue de pacientes com e sem glaucoma primário de ângulo aberto. Métodos: Foram analisadas amostras de 56 participantes submetidos à cirurgia ocular. Os pacientes foram divididos em dois grupos: pacientes com catarata apenas (n=28), e pacientes com catarata e glaucoma primário de ângulo aberto (n=28). Amostras de sangue venoso (2ml) e humor aquoso (150 µl, via paracentese) foram coletadas durante a facoemulsificação (apenas catarata) ou cirurgia de glaucoma (catarata e glaucoma primário de ângulo aberto). As atividades sérica do humor aquoso de renina, enzima conversora de angiotensina 1 e enzima conversora de angiotensina 2 de todos os pacientes foram avaliadas por ensaios fluorimétricos, e os resultados foram analisados por regressão multivariada. Resultados: Tanto a atividade da renina no humor aquoso quanto à razão humor aquoso/soro da atividade da renina foram significativamente menores nos pacientes com catarata e glaucoma primário de ângulo aberto do que em pacientes com catarata apenas [(média ± DP): 0,018 ± 0,006 ng/ml/h vs 0,045 ± 0,009 ng/ml/h; p<0,001 e 0,05 ± 0,02 vs 0,13 ± 0,05; p=0,025]. Análises multivariadas mostraram uma releção significativa entre menor atividade de renina no humor aquoso e glaucoma primário de ângulo aberto [coeficiente (±erro padrão): -0,029 ± 0,013; p=0,026]. Conclusões: Como a maioria dos pacientes com glaucoma primário de ângulo aberto usavam o colírio de timolol, estudos futuros envolvendo um maior número de pacientes e retirada prévia do tratamento são necessários para se discriminar o envolvimento do uso de betabloqueadores na atividade da renina no humor aquoso.

    Resumo em Inglês:

    ABSTRACT Purpose: The renin-angiotensin system is involved in the pathogenesis of retinal ischemic conditions and glaucoma. Our objective was to evaluate the renin, angiotensinconverting enzyme 1, and angiotensin-converting enzyme 2 activities in aqueous humor and blood samples of patients with and without primary open-angle glaucoma. Methods: We analyzed samples from 56 participants who underwent ocular surgeries. The patients were divided into two groups: patients with cataract alone (n=28) and patients with cataract and primary open-angle glaucoma (n=28). Venous blood (2 ml) and aqueous humor (150 µl, via paracentesis) samples were collected during phacoemulsification (cataract only) or glaucoma surgery (cataract and primary open-angle glaucoma). The serum and aqueous humor renin, angiotensin-converting enzyme 1, and angiotensin-converting enzyme 2 activities of all patients were evaluated by fluorimetric assays, and results were analyzed by using multivariate regression analysis. Results: Both the aqueous humor renin activity and renin activity aqueous humor/serum ratio were significantly lower in patients with cataract and primary open-angle glaucoma than in patients with cataract only [(mean ± SE): 0.018 ± 0.006 ng/ml/h vs 0.045 ± 0.009 ng/ml/h, p<0.001; 0.05 ± 0.02 vs 0.13 ± 0.05, p=0.025]. Multivariate analyses showed a significant relationship between lower aqueous humor renin activity and primary open-angle glaucoma [coefficient (±SE): -0.029 ± 0.013, p=0.026]. Conclusions: Our results showed that patients with primary open-angle glaucoma had lower aqueous humor renin activity. As timolol eye drops were used by most of the primary open-angle glaucoma patients, we propose that a large sample of washed-out patients should be studied in the future to discriminate the involvement of b-blocker treatment in the aqueous humor renin activity.
  • Incidência de displasia do epitélio conjuntival em pacientes com diagnóstico de pterígio Original Article

    Lomelí-Linares, Daniel; García-Salgado, Lissete; Riancho-Sánchez, Gabriela; Lopez-Star, Ellery; Lansingh, Van C.; Corredor-Casas, Sonia

    Resumo em Português:

    RESUMO Objetivo: Determinar a frequência de neoplasia escamosa da superfície ocular associada ao pterígio com apresentação clínica, em um centro de referência em Oftalmologia da região central do México. Métodos: Revisamos os laudos histopatológicos e as lâminas de biópsia de todos os pacientes que foram submetidos à cirurgia de pterígio de 2014 a 2016 no Instituto Mexicano de Oftalmologia, na cidade de Querétaro. Resultados: Estudamos 177 amostras de biópsia; 66% eram de pacientes do sexo feminino, sendo a mediana da idade de 52 anos. Encontramos neoplasia escamosa da superfície ocular em 11,29% (n=20). Uma amostra de biópsia mostrou um carcinoma queratinizante infiltrativo pouco diferenciado. Conclusões: A prevalência da neoplasia escamosa da superfície ocular nessa região parece ser maior do que a indicada por outras pesquisas. Mais estudos de âmbito nacional são necessários para determinar a verdadeira prevalência da neoplasia escamosa da superfície ocular no México e examinar os fatores de risco relacionados.

    Resumo em Inglês:

    ABSTRACT Purpose: To determine the frequency of ocular squamous surface neoplasia associated with pterygium in an ophthalmology reference center in Central Mexico. Methods: We reviewed histopathological reports and slides of all patients who underwent pterygium surgery from 2014 to 2016 at the Instituto Mexicano de Oftalmologia in Queretaro (Mexico). Results: We studied 177 biopsy samples; 66% were from women, and the median age was 52 years. We found ocular squamous surface neoplasias in 11.29% (n=20) of the samples. One biopsy sample revealed a poorly differentiated keratinizing and infiltrating carcinoma. Conclusions: The prevalence of ocular squamous surface neoplasia in our region appears to be high. Countrywide studies are necessary to determine the true prevalence of ocular squamous surface neoplasia in Mexico and to examine related risk factors.
  • Reposicionamento espontâneo de uma lente intraocular na câmara posterior: uma mera coincidência? Letters

    Wern-Yih, Chong; Jan-Bond, Chan; Sudha, Menon; Norlelawati, Abu; Shatriah, Ismail

    Resumo em Português:

    RESUMO Apesar dos recentes avanços na cirurgia moderna de catarata e da aplicação de uma ampla gama de novos dispositivos, o deslocamento tardio de uma lente intraocular dentro do saco capsular continua a ser uma complicação devastadora, ainda que rara. Várias técnicas cirúrgicas e não cirúrgicas têm sido usadas para tratar esta complicação. Este é o relato de um caso de reposicionamento espontâneo de uma lente intraocular sub-luxada anteriormente dentro do saco capsular do olho esquerdo. Este reposicionamento pode ter sido causado pelos efeitos opostos da aplicação tópica simultânea de brimonidina e prednisolona. O deslocamento foi tratado sem manipulação agressiva ou intervenção cirúrgica.

    Resumo em Inglês:

    ABSTRACT Despite the recent developments in modern cataract surgery and the application of a vast array of new devices and machines, late in-the-bag intraocular lens dislocation remains a devastating, albeit rare, complication. Various nonsurgical and surgical techniques have been used to manage this complication. We report a case of spontaneous repositioning in the left eye of an anteriorly subluxated in-the-bag intraocular lens. The spontaneous repositioning may have been caused by antagonistic effects related to the topical administration of brimonidine and prednisolone. The dislocation was treated without aggressive manipulation or surgical intervention.
  • Dacriocistocele congênita diagnosticada por ultrassonografia pré-natal com resolução espontânea Letters

    Cruciat, Gheorghe; Florian, Andreea; Cotutiu, Paul; Nemeti, Georgiana; Nicoara, Simona

    Resumo em Português:

    RESUMO A dacriocistocele é uma anormalidade facial benigna rara do sistema nasolacrimal, que pode ser detectada na rotina pré-natal durante o terceiro trimestre da gravidez. O ultrassom é o método de escolha, mas a ressonância magnética também pode ser usada em casos específicos. Na maioria das vezes, a dacriocistocele é um achado temporário, que pode se resolver espontâneamente ainda no útero ou após o nascimento. Quando a anormalidade é bilateral e persiste na vida neonatal, pode levar a complicações respiratórias. Este é o relato do caso de um feto com dacriocistocele bilateral diagnosticada por ultrassom pré-natal no início do terceiro trimestre da gravidez, com reabsorção espontânea após o nascimento.

    Resumo em Inglês:

    ABSTRACT Dacryocystocele is a rare benign facial abnormality of the nasolacrimal system, which may be detected at the antenatal workup during the third trimester of pregnancy. Ultrasound is the method of choice for this examination. However, magnetic resonance imaging may also be used in selected cases. Dacryocystocele is mostly a transient finding; it may resolve spontaneously in utero or postnatally. When the defect is bilateral and persists in neonatal life, it may lead to respiratory complications. We report a case of a fetus with bilateral dacryocystocele diagnosed by prenatal ultrasound at the beginning of the third trimester of pregnancy with spontaneous postpartum resorption.
  • Remoção de perfluorocarbono líquido subfoveal, sem retinotomia, através do peeling da membrana limitante interna Letters

    Silvestre, Fernanda; Silvestre, Gabriela; Lira, Rodrigo Pessoa Cavalcanti

    Resumo em Português:

    RESUMO O perfluorocarbono líquido tem sido amplamente durante cirurgias vitreorretinianas. A retenção subretiniana, é uma complicação intraoperatória rara, mas mesmo pequenas quantidades podem danificar a estrutura e função macular, e nenhum tratamento padrão foi estabelecido. Encontramos uma mulher de 43 anos que apresentou bolha subfoveal retida após uma cirurgia vitreorretiniana devido a descolamento de retina regmatogênico. Aqui, descrevemos o procedimento que usamos para remover o líquido perfluorocarbono sem retinotomia usando peeling da membrana limitante interna.

    Resumo em Inglês:

    ABSTRACT Perfluorocarbon liquid has been widely used during vitreoretinal operations. Subretinal retention is a rare intraoperative complication, but even small quantities can damage the macular structure and function, and no standard treatment has been established. We encountered a 43-year-old woman who presented a retained subfoveal bubble after a vitreoretinal operation due to primary rhegmatogenous retinal detachment. Herein, we describe the procedure we used to remove the perfluorocarbon liquid without retinotomy using internal limiting membrane peeling.
  • Anomalia de “Morning Glory” associada à extenso hemangioma infantil como apresentação da Síndrome PHACE Letters

    Hokazono, Kenzo; Okuyama, Vinícius Tadashi; Cunha, Leonardo Provetti; Monteiro, Mário Luiz Ribeiro

    Resumo em Português:

    RESUMO O hemangioma infantil é a causa mais comum de tumor benigno na infância e usualmente é uma condição isolada podendo ocorrer em diferentes regiões do corpo. No entanto, hemangiomas infantil extensos podem ser associados com outras malformações sistêmicas incluindo anomalias no sistema nervoso central, cerebrovasculares, cardíacas e oftalmológicas, uma condição denominada síndrome PHACE. Neste trabalho, descrevemos o caso de um paciente com síndrome PHACE que se apresentou com um extenso hemangioma facial e anomalia de “morning glory”.

    Resumo em Inglês:

    ABSTRACT Infantile hemangioma, the most common benign tumor in infancy, is usually an isolated condition occurring in many different locations in the body. However, large infantile hemangioma may be associated with other systemic malformations, including central nervous system, cerebrovascular, cardiac, and ophthalmology abnormalities, a condition termed PHACE syndrome. In this paper, we describe a case of PHACE syndrome that was presented with the unique association of a large facial infantile hemangioma and morning glory anomaly.
  • A prescrição do astigmatismo revisada Review Article

    Faria-e-Sousa, Sidney Julio de

    Resumo em Português:

    RESUMO A abordagem de qualquer condição refrativa do olho com astigmatismo regular é mais complicada do que a da miopia ou hipermetropia isoladamente. Requer familiaridade com as imagens complexas coletivamente identificadas como o conóide de Sturm. Felizmente, apenas três deles desempenham um papel crítico na interpretação da ametropia com astigmatismo. Este manuscrito mostra como uma estratégia de prescrição para as ametropias associadas ao astigmatismo regular pode evoluir a partir dessas três imagens principais.

    Resumo em Inglês:

    ABSTRACT The approach to any refractive condition of the eye with regular astigmatism is more complicated than that for myopia or hyperopia alone. It requires familiarity with the complex images collectively identified as Sturm’s conoid. Fortunately, only three of those play a critical role in the interpretation of ametropia with astigmatism. This manuscript discusses a prescription strategy for ametropias associated with regular astigmatism evolved from those three key images.
  • Endoftalmite bilateral de pseudomonas após cirurgia bilateral imediata de catarata: primum non nocere Letters To The Editor

    Arshinoff, Steve A.; Claoué, Charles; Mehta, Cyres; Johanssen, Bjorn
  • Um alerta contra a associação de doxiciclina com isotretinoína Letters To The Editor

    Costa, Alexandre Xavier da; Benchimol, Gabriel Lima; Reis, Tulio Frade
  • Retinopatia da prematuridade perdeu oportunidades: a urgência de fazer mais Letters To The Editor

    Zimmermann-Paiz, Martin A.; Cid, Nancy C. Quezada-del; Burgos-Elías, Verónica; Ordoñez-Rivas, Ana M.; Aceituno, Silvia; Asturias, Ana L.
  • Biomecânica no DALK: Grande bolha versus Dissecção manual lamelar Letters To The Editor

    Gokul, Akilesh; Angelo, Lize; Vellara, Hans; Ziaei, Mohammed
Conselho Brasileiro de Oftalmologia Rua Casa do Ator, 1117 - cj.21, 04546-004 São Paulo SP Brazil, Tel: 55 11 - 3266-4000, Fax: 55 11- 3171-0953 - São Paulo - SP - Brazil
E-mail: abo@cbo.com.br