The effect of slope and of antecedent soil moisture on quality and quantity of stored, percolated and retained fractions on extensive green roofs

This study investigated the effect of slope and antecedent soil moisture on the water depth stored and percolated on extensive green roofs built in pilot scale. For this purpose, slopes of 10, 20 and 30% were investigated. Moisture was measured before and after each test in order to determine the differential moisture (∆U). The experimental runoff and percolated flow were analyzed by varying moisture and slope. Apparent color and turbidity were measured on runoff and percolated flow for each one of the modules. The results yielded that for the slopes of 10% the smaller values of runoff was obtained (average of 1,01% ± 0,7%). For the others slopes (20% and 30%), the runoffs were around 35% ± 15%. The sum of runoff and percolated water results in 77% (average) for slope of 10% and 80% for 20% and 30%. The slope and moisture have explained 87% of data for retained water and 81% for runoff. For percolated flow the inverse trend was observed. The retained water was 11,6±1,4mm for the module with 10% of slope, around 10,0±1,2 mm for the module with 20% of slope, and about 9,5±1,1 mm for the module with 30%. The results pointed out that both slope and antecedent moisture are crucial for runoff reduction and for material transportation.

Green roof; Compensatory technique; Rainfall simulation