Acessibilidade / Reportar erro

Simultaneous electrocardiogram during routine electroencephalogram: arrhythmia rates through the eyes of the cardiologist

Eletrocardiograma simultâneo durante eletroencefalograma de rotina: taxas de arritmia pelos olhos do cardiologista

ABSTRACT

Background:

The importance of simultaneous 2-lead electrocardiogram (ECG) recording during routine electroencephalogram (EEG) has been reported several times on clinical grounds.

Objective:

To investigate arrhythmia rates detected by simultaneous 2-lead ECG in our patient sample undergoing routine EEG. Remarkably, we sought to assess the possible expansion of results with a more experienced interpretation of simultaneous ECG.

Methods:

Simultaneous 2-lead ECG recordings during routine EEG, performed between January and March, 2016, have been retrospectively analyzed by a cardiology specialist. In addition, EEG reports were screened with the keywords ‘arrhythmia, tachycardia, bradycardia, atrial fibrillation, extrasystole’ to evaluate the neurologist interpretation.

Results:

Overall, 478 routine EEG recordings were scanned. The mean age of the patients was 42.8±19.8 (16–95), with a sex ratio of 264/214 (F/M). In 80 (17%) patients, findings compatible with arrhythmia were identified on simultaneous ECG after a cardiologist's evaluation. The detected arrhythmia subtypes were: ventricular extrasystole (n=27; 5.6%), supraventricular extrasystole (n=23; 4.8%), tachycardia (n=9; 1.8%), prolonged QRS duration (n=7; 8.7%), atrial fibrillation (n=6; 1.2%), and block (n=6; 1.2%). On the other hand, keywords related to arrhythmia were present in 45 (9.4%) of EEG reports. The reported statements were tachycardia (3.3%), arrhythmia (2.5%), bradycardia (2.1%), and extrasystole (1.5%).

Conclusions:

A considerably high rate of arrhythmia cases was determined on simultaneous ECG during routine EEG after being interpreted by a cardiologist. However, the screening results of EEG reports revealed relatively low arrhythmia rates. These results suggest that the detection rates of ECG abnormalities during routine EEG may be potentially improved.

Keywords:
Electroencephalography’; Electrocardiography; Arrhythmia; Seizure; Association

Academia Brasileira de Neurologia - ABNEURO R. Vergueiro, 1353 sl.1404 - Ed. Top Towers Offices Torre Norte, 04101-000 São Paulo SP Brazil, Tel.: +55 11 5084-9463 | +55 11 5083-3876 - São Paulo - SP - Brazil