Acessibilidade / Reportar erro

Analysis of Electronic Apex Locators in Human Teeth Diagnosed With Apical Periodontitis

Abstract

Electronic apex locators (EAL) have been used to establish the working length (WL) in root canal treatment. In teeth diagnosed with apical periodontitis, resorption of tooth apical structures can lead to difficulties to obtain an appropriate WL. The aim was to compare the capacity of three EAL’s (Root ZX II, Raypex 6 and Endo-Eze Quill) to locate the tip of the K-file between 0 to -0.5 mm from the apical foramen (AF) on teeth diagnosed with asymptomatic apical periodontitis (AAP). Electronic working length was performed on 60 roots with AAP. A K-file #15 was inserted in the root canal until the apical foramen (AF) was located, and followed was re-adjusted to -0.5 mm through observation in EAL display. The K-file was fixed to the tooth with composite and teeth were extracted. The 4 apical millimeters were worn out until the K-file could be seen and were prepared and measured its distance to AF in a scanning electron microscope. Appropriate WL was when the tip of the K-file was located between 0 to -0.5 mm from AF. Results: Root ZX II showed significant difference (p<0.01) with the other two EALs. Root ZX II presented the better performance than Raypex 6 or Endo-Eze Quill in teeth with AAP.

Key Words:
periapical periodontitis; endodontics; tooth apex; electronic apex locators; root canal therapy

Resumo

Os localizadores eletrônicos apicais têm sido usados ​​para estabelecer o comprimento de trabalho no tratamento do canal radicular. Nos dentes diagnosticados com periodontite apical, a reabsorção das estruturas apicais dos dentes pode levar a dificuldades na obtenção de uma odontometria apropriada. Este estudo comparou três localizadores apicais (Root ZX II, Raypex 6 e Endo-Eze Quill) para localizar a ponta do instrumento K-file entre 0 a -0,5 mm do forame apical em dentes com diagnóstico de periodontite apical assintomática. O comprimento de trabalho eletrônico foi realizado em 60 dentes com periodontite apical assintomática. Uma lima K-file de número 15 foi inserida no canal radicular até a localização do forame apical, e seguida foi reajustada para -0,5 mm por meio de observação no visor do localizador eletrônico apical. A lima K-file foi fixada ao dente usando compósito, e a seguir os dentes foram extraídos. Os 4 milímetros apicais foram desgastados até que a lima K-file pudesse ser visualizada para as medidas de distância no forame apical por meio de microscópio eletrônico de varredura. O comprimento de trabalho apropriado foi determinado quando a ponta do instrumento estivesse localizada entre 0 a -0,5 mm do forame apical. O Root ZX II apresentou o melhor desempenho (p<0,01) que o Raypex 6 ou Endo-Eze Quill em dentes humanos com periodontite apical assintomática.

Introduction

The therapeutic protocol to removal of vital or necrotic tissue, microorganisms and their products is challenging to the root canal treatment successful 11 Nair PNR, Sjögren U, Figdor D, Sundqvist G. Persistent periapical radiolucencies of root-filled human teeth, failed endodontics treatments and periapical scars. Oral Surg Oral Med Oral Pathol Oral Radiol Endod1999;87:617-627.. The obtainment of an appropriate working length (WL) is essential to predictive good endodontic therapy. The WL is the distance between a coronal reference point and an apical one 22 Glossary Glossary of Terms Used in Endodontics. Chicago, IL: American Association of Endodontists, 2016., and it must be adequate so the damage to periapical tissues and interference with the healing process can be avoided 33 Ricucci D, Langeland K. Apical limit of root canal instrumentation and obturation, part 2. A histological study. Int Endod J1998;31:394-409..

The working length is established using radiographic and electronic methods 44 Gordon MPJ, Chandler NP. Electronic apex locators. Int Endod J2004;37:425-437.. Radiographic determination of WL has been used for many years. However, it has difficulties and limitations. It does not allow observing the position of the apical foramen (AF) or identifying the cementum-dentin-canal zone (CDC), and the interpretation of the radiographic image is affected by superposition of anatomical structures 44 Gordon MPJ, Chandler NP. Electronic apex locators. Int Endod J2004;37:425-437.. Custer 55 Custer LE. Exact methods of locating the apical foramen. J Natl Dent Assoc 1918;5:815-819. in 1918 suggested the electrical method for the first time under the electric conductivity principle. Suzuki 66 Suzuki K. Experimental study of iontophoresis. Japanese J Stomatol 1942;16:411-429. observed electrical activity in the periodontal ligament through constant values. Sunada 77 Sunada I. New method for measuring the length of the root canal. J Dent Res 1962;41:375-387. designed the first electronic apex locator (EAL) and called it “ohmmeter”. This device had operated under the electric resistance principle.

Going forward, 2nd- (impedance), 3rd- (multi-frequency) and 4th-generation (double frequency) EALs were developed 88 Mc Donald NJ. The electronic determination of working length. Dental Clinics of North America 1992;36:293-297.. Root ZX and Raypex 6, work calculating the quotient of the impedances at two frequencies (0.4 and 8 kHz), measured simultaneous and continuous. Endo Eze-Quill works use a spectrum of four frequencies (from 0.4 and 8 kHz). Every EAL calculates the AF by an own algorithm.

Apical periodontitis (AP) is a consequence of pulp necrosis and constitute on the inflammation of the apical periodontium, leading to morphological changes on the periapical area and radicular apex, identified as radiolucencies 11 Nair PNR, Sjögren U, Figdor D, Sundqvist G. Persistent periapical radiolucencies of root-filled human teeth, failed endodontics treatments and periapical scars. Oral Surg Oral Med Oral Pathol Oral Radiol Endod1999;87:617-627.,99 Delzangles B. Scanning electron microscopic study of apical and intraoral resorption. J Endod1989;15:281-285.. These structural modifications of the root and the AF must be considered during the endodontic treatment, as apical foramen (AF) localization and WL determination are more difficult on teeth with apical resorption 1010 Piasecki L, Carneiro E, Fariniuk LF, Westphalen VPD, Fiorentin MA, Silva Neto UX. Accuracy of Root ZX II in locating foramen in teeth with apical periodontitis: an in vivo study. J Endod 2011;37:1213-1216..

Modern electronic apex locators can determine working length with accuracies of greater than 90%. Root ZX II is a device with high precision and it is considered as the gold standard in electronic working length 44 Gordon MPJ, Chandler NP. Electronic apex locators. Int Endod J2004;37:425-437.,1111 Vasconcelos BC, Araújo RBR, Alves e Silva FCF, Luna-Cruz SM, Duarte MAH, Fernandes CAO. In vivo accuracy of two electronic foramen locators based on different operation systems. Braz Dent J 2014;25:12-16.. However, there is limited evidence on the clinical use of the mentioned EAL´s to establish WL in teeth with AP 1010 Piasecki L, Carneiro E, Fariniuk LF, Westphalen VPD, Fiorentin MA, Silva Neto UX. Accuracy of Root ZX II in locating foramen in teeth with apical periodontitis: an in vivo study. J Endod 2011;37:1213-1216.,1212 Saatchi M, Aminozarbian MG, Hasheminia SM, Mortaheb A. Influence of apical periodontitis on the accuracy of 3 electronic root canal length measurement devices: an in vivo study. J Endod2014;40:355-359., especially with Raypex 6 and EndoEze-Quill. Therefore, this study compared Root ZX II, Raypex 6 and Endo-Eze Quill to locate the tip of the K-file between 0.0 to -0.5 mm of the AF in teeth with AP.

Material and Methods

Thirty patients of both genders, aged 20 to 60 years, who presented 36 teeth with diagnosis of pulpal necrosis (negative cold-test with Endo-Ice, Akron, OH, USA) and asymptomatic apical periodontitis (radiographically evaluated), indicated for tooth extraction were treated at the Endodontics Department of the Regional Military Specialty Hospital of Guadalajara, México. Maxillary and mandibular teeth (fifteen molars, nine premolars, and twelve incisors), with a total number of 60 root canals were included. In the case of a multiradicular tooth, every root showed radiographic periapical lesion. The cases of pregnancy, presence of internal resorption, root fractures, radiographically untreatable root canal path, massive coronal destruction or previous root canal treatment were excluded. This study was approval of the Ethics committee of the same Institution (CB/01/13). The patients were informed of the aims of this study, and written consent was obtained before their enrolment.

To calculate the size of the sample, the Power Analysis and Sample Size software (PASS 12, NCSS, Kaysville UT, USA) was used, obtaining a number of 15 samples per group, adding 30% of them, for possible losses. Electronic measurements were carried out after being randomly allocated (www.random.org) to one of the three EAL: Root ZX II (J. Morita MFG Corp., Kyoto, Japan), Raypex 6 (VDW GmbH, Munich, Germany) or Endo-Eze Quill (Ultradent Products Inc., South Jordan UT, USA).

All of the procedures were performed using sterile equipment. Local anesthesia was applied with 2% lidocaine/epinephrine (Zeyco FD, Zapopan, México) by regional and local techniques. With a water-cooled high-speed carbide bur #2 to #4 (Kerr, Glendora CA, USA) the previous restorations and decay were removed. After rubber dam isolation completed with Block-out resin (Ultradent Products Inc.), the tooth was disinfected with iodine, and conventional endodontic cavity access was prepared. Using a DG-16 explorer (Hu-Friedy; Chicago ILL, USA) the root canal was identified and the coronal or incisal surface of the tooth was worn off using a tapered diamond bur 17R-5 (Kerr) in order to establish a perpendicular horizontal plane to the radicular axis. Two and a half percent sodium hypochlorite was used for irrigation (Clorox, México City, México). After exploration with a scouting #10 or #15 K-file (VDW GmbH), cervical interferences from the root canals were removed with a Gates-Glidden #3 (VDW GmbH). The excess of irrigant was sucked from the pulp chamber. With an active EAL and the external clip on the patient’s buccal mucosa, a #15 K-file was inserted to fit the anatomy of the previously identified root canal.

The K-file was attached to the file holder and the location of the AF was identified when the EAL display showed the location, following the manufacturer’s instructions. The K-file was readjusted until it indicated -0.5 mm short from the AF, Root ZX II on the green line, Raypex 6 on the first two yellow bars and Endo-Eze Quill on the green LED light. In most of the cases, the files were not fair in the apical portion. The K-file was maintained for at least 5 s so the reading could be stabilized, then fixed to the tooth with light-cured composite (Tetric N-Collection, Ivoclar-Vivadent, Liechtenstein). The teeth were carefully extracted and maintained in 10% buffered formaldehyde. Curettage of socket and sutures of gingiva were done. The conventional post-extraction indications were given to patients.

Under optical magnification 16X (OPMI 99, Carl Zeiss, Oberkochen, Germany), the buccal wall of the roots was worn out 4 mm apical to cervical with an XL Zekrya high-speed surgical bur (Dentsply, York PA, USA) cooling with water spray until the K-file could be seen. Five mL of EDTA (MD-Cleanser, Borgatta, México City, México) were used as final irrigation to remove dentinal debris from the apical wear. In the samples in which the K-file was visible outside the apical foramen, the roots were not worn.

The samples were dehydrated in 100% ethanol, dried and covered by gold in a sputtering (Ernest F. Fullam, New York NY, USA) and observed in a high vacuum scanning electron microscope (MIRA 3 Tescan, Kohoutovice, Czech Republic). Apex amplified images (75X to 151X) were obtained, including AF and the tip of the file. The images were analyzed by three endodontists separately, blinded to each group. Prior to the evaluation, they received ten SEM images of worn apex roots where AF was visible, not related to the study sample, to calibrate. One week after, each endodontist established the beginning of the AF, following these instructions: the criterion used to locate the beginning of AF was the most cervical limit of the foramen; the most cervical limit of the foramen must be found and marked with a yellow line; when in doubt, a tentative limit on most cervical point of AF must be marked, and the three evaluators to reach a consensus must be discussed as “doubt”.

All images were evaluated on a 24” LCD monitor (LMD-2435MD Sony, Tokyo, Japan) in a dark room. Consensus by the three evaluators met as a group, was reached on samples marked as “doubt”. Three weeks after the first evaluation, the endodontists again evaluated all images, under the same conditions. Agreement among and within evaluators was determined with Pearson’s correlation coefficient (SPSS 13, Chicago IL, USA).

The most cervical limit of the foramen obtained by coincidence or consensus in each case was used to measure the distance from the tip of the K-file to the foramen. If the apical foramen was severely modified or eliminated, or the tip of the K-file was affected by the worn, the sample was excluded.

Using Adobe Photoshop 2015 software (Adobe Corp., San José, CA, USA), a calibrated operator in SEM, measured the distance from the tip of the file to the most cervical portion of AF, and the result was recorded on a data collection sheet. A precise criterion was assigned when the tip of the K-file was placed 0.0 to -0.5 mm short from the most cervical portion of AF. It was longer if the K-file was beyond (+0.1 mm or more) and shorter if it was -0.51 mm or more from the AF. One-way ANOVA statistical test was used to evaluate the measures obtained with the three EALs, and Fisher’s and Bonferroni’s multiple comparisons post-hoc tests were applied (statistical level significance p<.05).

Results

Out of the 60 samples, 9 teeth were excluded due to AF was eliminated or affected during the worn, and 4 due to the worn-looking tip of the K-file. A total of 47 roots were evaluated, 15 using Root ZX II, 17 using Raypex 6 and 15 using Endo-Eze Quill. Inter and intra agreement score was 0.96 and 0.98. Table 1 presents the number, percentages of roots and minimum and maximum values of the position of the file obtained with each device.

Table 1
Number and percentage of roots and the position of the file with respect to the beginning of the foramen. The minimum and maximum values in mm are in parentheses

The average distance (Fig. 1) from the tip of the K-file to the AF was -0.11 (±0.58 mm) for Root ZX II, +0.37 (±0.62 mm) for Raypex 6, and +0.33 (±0.78 mm) for Endo-Eze Quill. ANOVA and Fisher’s test showed statistical differences among groups (p=0.010). Statistical difference was observed from Root ZX II in relation to Raypex 6 (p<0.016) and Endo-Eze Quill (p<0.038). There was no difference between Raypex 6 and Endo-Eze Quill. SEM images of extracted roots with K-file from each EAL can be observed in Figure 2.

Figure 1
Distances means of the three EAL’s. Negative values mean short of the AF. Positive values mean beyond of the AF

Discussion

The aim of this study was to compare the capacity of three EALs to determine the position of the K file tip between 0.0 to -0.5 mm from the AF in teeth with AP, because there is limited clinical evidence of its use in those teeth 1010 Piasecki L, Carneiro E, Fariniuk LF, Westphalen VPD, Fiorentin MA, Silva Neto UX. Accuracy of Root ZX II in locating foramen in teeth with apical periodontitis: an in vivo study. J Endod 2011;37:1213-1216.,1212 Saatchi M, Aminozarbian MG, Hasheminia SM, Mortaheb A. Influence of apical periodontitis on the accuracy of 3 electronic root canal length measurement devices: an in vivo study. J Endod2014;40:355-359.. Regarding the results obtained, and with the criteria established, Root ZX showed an accuracy percentage of 53.3%, Endo-Eze Quill of 46.6%, while Raypex 6 of 37.5%, which are values lower than those observed in other studies (10-17).

These differences were attributed to two factors. The first is the criteria to determine the beginning of the AF, which was established at its most cervical point. From an anatomical point of view, when the apical foramen is located in one of the lateral walls of the root apex 1818 Kuttler Y. Microscopic investigation of root apexes. J Am Dent Ass 1955;50:544-552. (Fig. 2B), the foramen has its beginning at the most cervical limit, and from this point, the tip of the instrument reaches the periodontal ligament. In other studies (12-16) only “apical foramen” is mentioned, without considering this aspect. The second factor, the possibly led to these low results of the three EALs, also occurred due to the WL localization criteria. In this work, the margin of distance from the position of the file to the beginning of the AF was 0.0 to -0.5 mm, while other studies 1212 Saatchi M, Aminozarbian MG, Hasheminia SM, Mortaheb A. Influence of apical periodontitis on the accuracy of 3 electronic root canal length measurement devices: an in vivo study. J Endod2014;40:355-359.,1313 ElAyouti A, Dima E, Ohmer J, Sperl K, Ohle C, Löst C. Consistency of apex locator function: A clinical study. J Endod 2009;35:179-181.,1414 Wrbas KT, Ziegler AA, Altenburger MJ, Schirrmeister JF. In vivo comparison of working length determination with two electronic apex locators. Int Endod J 2007;40:133-138.,1515 Stöber EK, Duran-Sindreu F, Mercadé M, Vera J, Bueno R, Roig M. An evaluation of Root ZX and iPex Apex locators: an in vivo study. J Endod2011;37:608-610.,1616 Duran-Sindreu F, Stöber EK, Mercadé M, Vera J, Garcia M, Bueno R et al. Comparison of in vivo and in vitro readings when testing the accuracy of the Root ZX apex locator. J Endod 2012;38:236-239. established a range of ±0.5 and +1 mm to the AF. In the present study, the value of -0.5 mm was established as an accuracy WL, because the average distance from the AF to the CDC zone is -0.52 mm 1818 Kuttler Y. Microscopic investigation of root apexes. J Am Dent Ass 1955;50:544-552., considering that the best healing results after the root canal treatment are obtained when the level is within the CDC zone 1919 Ricucci D. Apical limit of root canal instrumentation and obturation, part 1. Literature review. Int Endod J 1998;31:384-393.. It is thought that by widening the range of measurement, results could increase their accuracy percentage, but the precision of the EAL would not be evaluated reliably.

Figure 2
SEM images of the working length with the three devices. A: Root ZX II, precise in relation to the AF (SEM 15 kV - 98?). B: Raypex 6: apical foramen is located on the distal wall of the root apex. Even the file is short from root apex, the tip of the file is observed beyond the cervical limit from AF. Resorption areas can be observed (SEM 10 kV - 99). C: Endo-Eze Quill, precise in relation to the AF (SEM 10 kV - 77?).

The AP has a negative effect on the root canal treatment 1919 Ricucci D. Apical limit of root canal instrumentation and obturation, part 1. Literature review. Int Endod J 1998;31:384-393., because there is resorption at the periapical tissues, which destroys bone, cement, and dentin 11 Nair PNR, Sjögren U, Figdor D, Sundqvist G. Persistent periapical radiolucencies of root-filled human teeth, failed endodontics treatments and periapical scars. Oral Surg Oral Med Oral Pathol Oral Radiol Endod1999;87:617-627., which results in the formation of resorption lacunae (craters) in apical zone, foramen, and CDC zone deformation 99 Delzangles B. Scanning electron microscopic study of apical and intraoral resorption. J Endod1989;15:281-285.; furthermore, there is internal resorption in 74.7% of the roots with periapical disease 2020 Vier FV, Figueiredo JAP. Internal apical resorption and its correlation with the type of apical lesion. Int Endod J 2004;37:730-737.. In teeth with AP, Piasecki et al. 1010 Piasecki L, Carneiro E, Fariniuk LF, Westphalen VPD, Fiorentin MA, Silva Neto UX. Accuracy of Root ZX II in locating foramen in teeth with apical periodontitis: an in vivo study. J Endod 2011;37:1213-1216., using the Root ZX, founded an accuracy of 83%, while Saatchi et al. 1212 Saatchi M, Aminozarbian MG, Hasheminia SM, Mortaheb A. Influence of apical periodontitis on the accuracy of 3 electronic root canal length measurement devices: an in vivo study. J Endod2014;40:355-359. also in teeth with AP, testing Dentaport ZX, Raypex 5 and i-Root, reported an accuracy of 93.8%, 81.3%, and 75.0%, respectively, with a range of +0.5 mm. The accuracy found in these two studies 1010 Piasecki L, Carneiro E, Fariniuk LF, Westphalen VPD, Fiorentin MA, Silva Neto UX. Accuracy of Root ZX II in locating foramen in teeth with apical periodontitis: an in vivo study. J Endod 2011;37:1213-1216.,1212 Saatchi M, Aminozarbian MG, Hasheminia SM, Mortaheb A. Influence of apical periodontitis on the accuracy of 3 electronic root canal length measurement devices: an in vivo study. J Endod2014;40:355-359. in teeth with AP was greater than that observed in the present study, as reported at the beginning of this discussion section.

It is thought that WL is more precise in vital teeth than in teeth diagnosed with AP 1010 Piasecki L, Carneiro E, Fariniuk LF, Westphalen VPD, Fiorentin MA, Silva Neto UX. Accuracy of Root ZX II in locating foramen in teeth with apical periodontitis: an in vivo study. J Endod 2011;37:1213-1216., maybe due to the electric resistance of the root canal in cases of AP diminishes due to resorption and the increase in the diameter of the CDC zone 2020 Vier FV, Figueiredo JAP. Internal apical resorption and its correlation with the type of apical lesion. Int Endod J 2004;37:730-737.. Accuracy of EAL’s can be variable according to the AF, and CDC zone diameter, as well as the brand and type of the used EAL 2121 Serry A, Adel M, Elden EM. Accuracy of electronic apex locator in relation to the condition of human dental pulp: histological and histochemical study. J Am Sci 2012;8:391-397.,2222 Tsesis I, Blazer T, Ben-Izhack G, Taschieri S, Del Fabbro M, Corbella S et al. The precision of electronic apex locators in working length determination: A systematic review and meta-analysis of the literature J Endod2015;41:1818-1823.. According to the results of this study, in teeth with AP, EAL’s showed low precision to determine the WL.

In other conditions, EAL’s have acceptable reliability to determine WL 1010 Piasecki L, Carneiro E, Fariniuk LF, Westphalen VPD, Fiorentin MA, Silva Neto UX. Accuracy of Root ZX II in locating foramen in teeth with apical periodontitis: an in vivo study. J Endod 2011;37:1213-1216.,1111 Vasconcelos BC, Araújo RBR, Alves e Silva FCF, Luna-Cruz SM, Duarte MAH, Fernandes CAO. In vivo accuracy of two electronic foramen locators based on different operation systems. Braz Dent J 2014;25:12-16.,1212 Saatchi M, Aminozarbian MG, Hasheminia SM, Mortaheb A. Influence of apical periodontitis on the accuracy of 3 electronic root canal length measurement devices: an in vivo study. J Endod2014;40:355-359.,1313 ElAyouti A, Dima E, Ohmer J, Sperl K, Ohle C, Löst C. Consistency of apex locator function: A clinical study. J Endod 2009;35:179-181.,1414 Wrbas KT, Ziegler AA, Altenburger MJ, Schirrmeister JF. In vivo comparison of working length determination with two electronic apex locators. Int Endod J 2007;40:133-138.,1515 Stöber EK, Duran-Sindreu F, Mercadé M, Vera J, Bueno R, Roig M. An evaluation of Root ZX and iPex Apex locators: an in vivo study. J Endod2011;37:608-610.,1616 Duran-Sindreu F, Stöber EK, Mercadé M, Vera J, Garcia M, Bueno R et al. Comparison of in vivo and in vitro readings when testing the accuracy of the Root ZX apex locator. J Endod 2012;38:236-239.,1717 Ravanshad S, Adl A, Anvar J. Effect of working length measurement by electronic apex locator or radiography on the adequacy of final working length. J Endod2010;36:1753-1756.), including controlling the working length during the rotary instrumentation (2323 Parente LA, Levin MD, Vivan RR, Bernandes RA, Duarte MAH, Vasconcelos BC. Efficacy of electronic foramen locators in controlling root canal working length during rotary instrumentation. Braz Dent J 2015;26:547-551.). Parente et al. (2323 Parente LA, Levin MD, Vivan RR, Bernandes RA, Duarte MAH, Vasconcelos BC. Efficacy of electronic foramen locators in controlling root canal working length during rotary instrumentation. Braz Dent J 2015;26:547-551. evaluated ex vivo the efficacy of Root ZX and Propex II to control the root canal WL during rotary instrumentation. The precision values of 0.0 mm and -1.0 were 100% and 0.0% for Root ZX, and 100% and 66.7% for Propex, respectively, with a range of ±0.5 mm.

Wrbas et al. 1414 Wrbas KT, Ziegler AA, Altenburger MJ, Schirrmeister JF. In vivo comparison of working length determination with two electronic apex locators. Int Endod J 2007;40:133-138. evaluated in vivo Root ZX and Raypex 5 in vital teeth, with a range of ±0.5 mm. The results were statistically similar for both devices, with precision from 75% to 80% of the cases. Ravanshad et al. 1717 Ravanshad S, Adl A, Anvar J. Effect of working length measurement by electronic apex locator or radiography on the adequacy of final working length. J Endod2010;36:1753-1756. evaluated the accuracy of the WL with Raypex 5, being acceptable in 90% of the cases in the final obturation. In root canals with the presence of blood, Saatchi et al. 2424 Saatchi M, Aminozarbian MG, Noormohammadi H, Baghaei B. Influence of blood on the accuracy of raypex 5 and root ZX electronic foramen locators: an in vivo study. Braz Dent J2016;27:336-339. observed the accuracy of 86.2% for Root ZX and 83.3% for Raypex 5, with a range of +0.5 mm from AF.

Stöber et al. 1515 Stöber EK, Duran-Sindreu F, Mercadé M, Vera J, Bueno R, Roig M. An evaluation of Root ZX and iPex Apex locators: an in vivo study. J Endod2011;37:608-610. with a range of +0.5mm with Raypex 5 and MiniApex Locator obtained a percentage of accuracy of 75% and 77.8%, respectively, while in these same samples when the range was +1 mm, precision was 100% for both devices. Similarly, Duran-Sindreu et al. 1616 Duran-Sindreu F, Stöber EK, Mercadé M, Vera J, Garcia M, Bueno R et al. Comparison of in vivo and in vitro readings when testing the accuracy of the Root ZX apex locator. J Endod 2012;38:236-239. with Root ZX found 78.3% in the range of +0.5 mm; when the margin was extended to +1 mm, the precision was 100%. Another factor pointed by Piasecki et al. 2525 Piasecki L, Carneiro E, da Silva Neto UX, Westphalen VPD, Brandão CG, Gambarini G et al. The use of micro-computed tomography to determine the accuracy of 2 electronic apex locators and anatomic variations affecting their precision. J Endod2016;42:1263-1267., that can influence the accuracy of the EAL’s, is when the distance from apical constriction to apical foramen is more than 0.5 mm.

Tsesis et al. 2222 Tsesis I, Blazer T, Ben-Izhack G, Taschieri S, Del Fabbro M, Corbella S et al. The precision of electronic apex locators in working length determination: A systematic review and meta-analysis of the literature J Endod2015;41:1818-1823. in a meta-analysis study, found that gender, age, type of teeth, internal root canal humidity and device do not influence the precision; however, pulpal diagnosis and endodontic retreatment have a direct influence on the WL results. The WL short of the AF will keep the endodontic maneuvers within the root canal and will allow a biological WL with a better clinical prognosis 33 Ricucci D, Langeland K. Apical limit of root canal instrumentation and obturation, part 2. A histological study. Int Endod J1998;31:394-409.,1919 Ricucci D. Apical limit of root canal instrumentation and obturation, part 1. Literature review. Int Endod J 1998;31:384-393.. In the present study, the measurement from the K-file tip to the AF was made differently from other studies (10, 12-16), once that is less specific regarding which anatomical point is taken as a reference to measure the position of the K-file. In radiographic evaluation 1717 Ravanshad S, Adl A, Anvar J. Effect of working length measurement by electronic apex locator or radiography on the adequacy of final working length. J Endod2010;36:1753-1756., it was referring to the radicular apex. The AF is a variable three-dimensional anatomical structure therefore, it is critical to identify in which area of this anatomical space the measurement is obtained; as the WL on the same foramen can change if it is measured from its most apical or coronal border 1111 Vasconcelos BC, Araújo RBR, Alves e Silva FCF, Luna-Cruz SM, Duarte MAH, Fernandes CAO. In vivo accuracy of two electronic foramen locators based on different operation systems. Braz Dent J 2014;25:12-16.. In the literature, it was verified lack of studies that refer to previously identifying the starting point of AF; therefore, in the measurement, its most cervical position was considered.

The degree and extension of apical resorption or the presence of accessory canals and comparing the same device in teeth with or without AP were not evaluated and may be considered a limitation of the study. Further studies regarding these clinical conditions are required.

There is no 100% precision of EAL 44 Gordon MPJ, Chandler NP. Electronic apex locators. Int Endod J2004;37:425-437., and the possible differences among the results obtained with the different brands of EAL, can be related to the algorithm used in each one to calculate the quotient of the impedances of the frequencies measured. By another hand, it is important to know that AP and anatomic variations have an effect on EAL accuracy 2525 Piasecki L, Carneiro E, da Silva Neto UX, Westphalen VPD, Brandão CG, Gambarini G et al. The use of micro-computed tomography to determine the accuracy of 2 electronic apex locators and anatomic variations affecting their precision. J Endod2016;42:1263-1267.. The knowledge of anatomy and physiopathology of the periapical area and combined use of radiographic and electronic methods can improve the accurate determination of the WL in teeth with AP.

Root ZX II showed more precise than Endo-Eze Quill and Raypex 6 to locate the apical foramen in teeth with AP. The three EAL’s tested showed a low level of precision considered the presence of AP.

Acknowledgements

This research was funded partially by the Sub-Secretaría de Educación Superior, SEP, México, grant UDG-CA-657, IDCA10087, Fortalecimiento de Cuerpos Académicos 2018. The authors deny any conflicts of interest related to this study.

References

  • 1
    Nair PNR, Sjögren U, Figdor D, Sundqvist G. Persistent periapical radiolucencies of root-filled human teeth, failed endodontics treatments and periapical scars. Oral Surg Oral Med Oral Pathol Oral Radiol Endod1999;87:617-627.
  • 2
    Glossary Glossary of Terms Used in Endodontics. Chicago, IL: American Association of Endodontists, 2016.
  • 3
    Ricucci D, Langeland K. Apical limit of root canal instrumentation and obturation, part 2. A histological study. Int Endod J1998;31:394-409.
  • 4
    Gordon MPJ, Chandler NP. Electronic apex locators. Int Endod J2004;37:425-437.
  • 5
    Custer LE. Exact methods of locating the apical foramen. J Natl Dent Assoc 1918;5:815-819.
  • 6
    Suzuki K. Experimental study of iontophoresis. Japanese J Stomatol 1942;16:411-429.
  • 7
    Sunada I. New method for measuring the length of the root canal. J Dent Res 1962;41:375-387.
  • 8
    Mc Donald NJ. The electronic determination of working length. Dental Clinics of North America 1992;36:293-297.
  • 9
    Delzangles B. Scanning electron microscopic study of apical and intraoral resorption. J Endod1989;15:281-285.
  • 10
    Piasecki L, Carneiro E, Fariniuk LF, Westphalen VPD, Fiorentin MA, Silva Neto UX. Accuracy of Root ZX II in locating foramen in teeth with apical periodontitis: an in vivo study. J Endod 2011;37:1213-1216.
  • 11
    Vasconcelos BC, Araújo RBR, Alves e Silva FCF, Luna-Cruz SM, Duarte MAH, Fernandes CAO. In vivo accuracy of two electronic foramen locators based on different operation systems. Braz Dent J 2014;25:12-16.
  • 12
    Saatchi M, Aminozarbian MG, Hasheminia SM, Mortaheb A. Influence of apical periodontitis on the accuracy of 3 electronic root canal length measurement devices: an in vivo study. J Endod2014;40:355-359.
  • 13
    ElAyouti A, Dima E, Ohmer J, Sperl K, Ohle C, Löst C. Consistency of apex locator function: A clinical study. J Endod 2009;35:179-181.
  • 14
    Wrbas KT, Ziegler AA, Altenburger MJ, Schirrmeister JF. In vivo comparison of working length determination with two electronic apex locators. Int Endod J 2007;40:133-138.
  • 15
    Stöber EK, Duran-Sindreu F, Mercadé M, Vera J, Bueno R, Roig M. An evaluation of Root ZX and iPex Apex locators: an in vivo study. J Endod2011;37:608-610.
  • 16
    Duran-Sindreu F, Stöber EK, Mercadé M, Vera J, Garcia M, Bueno R et al. Comparison of in vivo and in vitro readings when testing the accuracy of the Root ZX apex locator. J Endod 2012;38:236-239.
  • 17
    Ravanshad S, Adl A, Anvar J. Effect of working length measurement by electronic apex locator or radiography on the adequacy of final working length. J Endod2010;36:1753-1756.
  • 18
    Kuttler Y. Microscopic investigation of root apexes. J Am Dent Ass 1955;50:544-552.
  • 19
    Ricucci D. Apical limit of root canal instrumentation and obturation, part 1. Literature review. Int Endod J 1998;31:384-393.
  • 20
    Vier FV, Figueiredo JAP. Internal apical resorption and its correlation with the type of apical lesion. Int Endod J 2004;37:730-737.
  • 21
    Serry A, Adel M, Elden EM. Accuracy of electronic apex locator in relation to the condition of human dental pulp: histological and histochemical study. J Am Sci 2012;8:391-397.
  • 22
    Tsesis I, Blazer T, Ben-Izhack G, Taschieri S, Del Fabbro M, Corbella S et al. The precision of electronic apex locators in working length determination: A systematic review and meta-analysis of the literature J Endod2015;41:1818-1823.
  • 23
    Parente LA, Levin MD, Vivan RR, Bernandes RA, Duarte MAH, Vasconcelos BC. Efficacy of electronic foramen locators in controlling root canal working length during rotary instrumentation. Braz Dent J 2015;26:547-551.
  • 24
    Saatchi M, Aminozarbian MG, Noormohammadi H, Baghaei B. Influence of blood on the accuracy of raypex 5 and root ZX electronic foramen locators: an in vivo study. Braz Dent J2016;27:336-339.
  • 25
    Piasecki L, Carneiro E, da Silva Neto UX, Westphalen VPD, Brandão CG, Gambarini G et al. The use of micro-computed tomography to determine the accuracy of 2 electronic apex locators and anatomic variations affecting their precision. J Endod2016;42:1263-1267.

Publication Dates

  • Publication in this collection
    28 Nov 2019
  • Date of issue
    Nov-Dec 2019

History

  • Received
    16 Mar 2019
  • Accepted
    23 July 2019
Fundação Odontológica de Ribeirão Preto Av. do Café, S/N, 14040-904 Ribeirão Preto SP Brasil, Tel.: (55 16) 3602-3982, Fax: (55 16) 3633-0999 - Ribeirão Preto - SP - Brazil
E-mail: bdj@forp.usp.br