Acessibilidade / Reportar erro
Ordenar publicações por
Brazilian Dental Journal, Volume: 35, Publicado: 2024
  • Influence of genetic polymorphisms on oral health-related quality of life after root canal treatment Article

    Queiroz, Graciane E. R.; Castilho, Thuanny; Guimarães, Ludmila Silva; Moraes, Vania Gomes; Silva, Erlange Andrade Borges da; Küchler, Erika Calvano; Silva-Sousa, Alice Corrêa; Sousa-Neto, Manoel Damião; Antunes, Lívia Azeredo Alves; Antunes, Leonardo Santos

    Resumo em Português:

    Resumo Avaliar o impacto de polimorfismos genéticos em interleucinas (IL1A rs17561, rs1304037; IL10 rs1800871; IL1RN rs9005), óxido nítrico (NOS2 rs2779249, rs2897518) e supressor da sinalização de citocinas (SOCS1 rs243327, rs33977706) na qualidade de vida relacionada à saúde bucal (QVRSB) de pacientes submetidos a tratamento endodôntico (TE). Métodos: A amostra foi composta por 108 participantes, que apresentavam dentes unirradiculares com lesão periapical assintomática. O impacto da QVRSB foi registrado usando o Oral Health Impact Profile (OHIP-14) antes, sete e 30 dias após o TE. Amostras de saliva foram coletadas como fonte de DNA genômico. Os polimorfismos genéticos foram genotipados por PCR em tempo real usando o método Taqman. Análises univariadas e multivariadas foram utilizadas (p<0,05). Resultados: Observou-se diferença significativa para o polimorfismo rs2297518 no gene NOS2 na limitação funcional nos modelos codominante (p=0,037) e recessivo (p=0,001); na dor física (p<0,001 em ambos os modelos); no desconforto psicológico (p<0,001 em ambos os modelos); na deficiência física (p<0,001 em ambos os modelos) e na deficiência psicológica (p<0,001 em ambos os modelos). Polimorfismos no gene SOCS1, no modelo recessivo, rs33977706 (p=0,045) e rs243327 (p=0,019), influenciaram a QVRSB no domínio desconforto psicológico. Conclusões: Polimorfismos nos genes NOS2 e SOCS1 influenciaram a QVRSB de pacientes submetidos a TE.

    Resumo em Inglês:

    Abstract To evaluate the impact of genetic polymorphisms in interleukins (IL1A rs17561, rs1304037; IL10 rs1800871; IL1RN rs9005), nitric oxide (NOS2 rs2779249, rs2897518) and suppressor of cytokine signaling (SOCS1 rs243327, rs33977706) on oral health-related quality of life (OHRQoL) of patients under-going root canal treatment (RCT). Methods: The sample consisted of 108 participants, presenting single-rooted teeth with asymptomatic periapical periodontitis. The impact of the OHRQoL was recorded using the Oral Health Impact Profile (OHIP-14) before, seven, and 30 days after RCT. Saliva samples were collected as a source of genomic DNA. Genetic polymorphisms were genotyped by Real-Time PCR using the Taqman method. Univariate and Multivariate analyses were used (p<0.05). Results: A significant difference was observed for the polymorphism rs2297518 in the NOS2 gene in functional limitation in the codominant (p=0.037) and recessive (p=0.001) models; in the physical pain (p<0.001 in both models); in psychological discomfort (p<0.001 in both models); in physical disability (p<0.001 in both models) and in psychological disability (p<0.001 in both models). Polymorphisms in the SOCS1 gene, in the recessive model, rs33977706 (p=0.045) and rs243327 (p=0.019), influenced the OHRQoL in the psychological discomfort domain. Conclusions: Polymorphisms in NOS2 and SOCS1 genes influenced the OHRQoL of patients undergoing RCT.
  • Effect of EGCG-based paste as intracanal dressing, in MMPs 2 and 9 expression in dog’s periapical lesions Article

    Rossi, Andiara De; Pradela, Tadeu; Liévana, Fernanda Souza; Segato, Raquel Assed Bezerra; León, Jorge Esquiche; Silva, Léa Assed Bezerra da; Nelson-Filho, Paulo

    Resumo em Português:

    Resumo A alta expressão de MMP-2 e MMP-9 em lesões periapicais desempenha um papel importante na degradação da matriz extracelular. Este estudo teve como objetivo investigar o efeito de uma pasta à base de epigalocatequina-3-galato (EGCG) como curativo intracanal na expressão de MMP-2 e MMP-9 em lesões periapicais. Lesões periapicais foram induzidas experimentalmente em 35 pré-molares de cães da raça beagle, maduros, divididos aleatoriamente em dentes saudáveis, lesões periapicais não tratadas, lesões periapicais tratadas em uma única sessão e lesões periapicais tratadas em duas sessões com a pasta de EGCG ou pasta à base de hidróxido de cálcio. O operador monitorou os animais e realizou a eutanásia após 120 dias para análises histopatológicas e de imunofluorescência para avaliar a expressão de MMP-2 e MMP-9. A análise estatística foi realizada utilizando p=0,05. O tratamento endodôntico em duas sessões com pasta à base de EGCG e pasta à base de hidróxido de cálcio proporcionou níveis semelhantes de reparação dos tecidos apicais e periapicais e neoformação de fibras do ligamento periodontal, cemento e osso alveolar. Em ambos os grupos, a expressão de MMP-2 e MMP-9 foi mínima, sendo observada no citoplasma de fibroblastos, osteoblastos, cementoblastos, cementócitos e endotélio vascular. Em ambos os grupos tratados em duas sessões, a expressão de MMP-2 e MMP-9 foi semelhante à dos dentes hígidos e significativamente menor do que nas lesões periapicais tratadas em sessão única ou não tratadas (p < 0,001). O uso da pasta à base de EGCG reduziu a expressão de MMP-2 e MMP-9 e permitiu o reparo de lesões periapicais, semelhante à pasta à base de hidróxido de cálcio, e foi superior ao tratamento realizado em sessão única.

    Resumo em Inglês:

    Abstract High expression of MMP-2 and MMP-9 in periapical lesions plays an important role in the degradation of the extracellular matrix. This study aimed to investigate the effect of epigallocatechin-3-gallate (EGCG)-based endodontic paste as an intracanal dressing on the expression of MMP-2 and MMP-9 in periapical lesions. Periapical lesions were experimentally induced in 35 mature beagle dog premolars randomly divided into healthy teeth, untreated periapical lesions, periapical lesions treated in a single session (control groups), and periapical lesions treated in two sessions with EGCG or calcium hydroxide-based pastes (experimental groups). After 120 days, specimens were obtained for histopathologic and immunofluorescence analyses to assess the expression of MMP-2 and MMP-9. The statistical analysis was performed using a p-value of 0.05. Endodontic treatment in two sessions using medication with EGCG and calcium hydroxide-based pastes provided similar repair of the apical and periapical tissues and neoformation of periodontal ligament fibers, cementum, and alveolar bone (p>0.05). The experimental groups treated in two sessions with both medications presented expression of MMP-2 and MMP-9 similar to that in healthy teeth (p>0.05), and significantly lower than teeth treated in a single session or untreated periapical lesions (p <0.001). Expression of MMP-2 and MMP-9 was observed in the cytoplasm of fibroblasts, osteoblasts, cementoblasts, cementocytes, and vascular endothelium. The use of EGCG-based endodontic paste reduced the expression of MMP-2 and MMP-9 and allowed repair of periapical lesions, similar to calcium hydroxide-based paste, and superior to treatment performed in a single session.
  • Natural canal deviation and dentin thickness of mesial root canals of mandibular first molars assessed by microcomputed tomography Article

    Amorim, Carolina Alonso; Marceliano-Alves, Marília F.; Gomes, Isabelle Louise; Provenzano, José C.; Alves, Flávio R. F.

    Resumo em Português:

    Resumo O objetivo deste trabalho foi avaliar a centralização e a espessura da dentina dos canais radiculares mesiais de primeiros molares inferiores por meio de microtomografia computadorizada (micro-CT). Material e métodos: Noventa e nove molares inferiores com canais tipo IV de Vertucci foram escaneados por micro-TC. O desvio mesiodistal e o centroide foram avaliados para os canais mesiovestibular (MB) e mesiolingual (ML), nos 4mm apicais e em todo o comprimento do canal. Resultados: A espessura da dentina foi semelhante para os canais MB e ML. A espessura mais estreita foi encontrada na parede distal de um canal MB (0,07mm), enquanto a mais larga foi encontrada na parede mesial de um canal MB (2,46mm). Na análise centroide, tanto o canal MB quanto o ML exibiram desvios quando comparados ao centroide da raiz, ao longo de todo o comprimento do canal e nos 4 mm apicais. Para o canal MB, o desvio médio foi de 0,83mm (0,02mm-2,30mm) para canal inteiro e 0,18mm (0,01mm-1,01mm) para o apical de 4mm. Da mesma forma, para o canal ML, o desvio médio mediu 0,83 mm (0,05 mm-3,99 mm) para o canal inteiro e 0,21 mm (0,01 mm-1,01 mm) para os 4 mm apicais. No geral, foram observados desvios em direção mesial das raízes, sendo 69% para canais MB e 57% para canais ML para canal inteiro, e 51% para canais MB dentro dos 4 mm. A exceção foi o canal ML, que apresentou maior desvio para distal nos 4mm apicais, representando 52% dos casos. A espessura da dentina foi consistente entre os canais mesiais dos molares inferiores. Entretanto, não há centralidade dos canais mesiais em suas raízes, com frequente desvio para mesial.

    Resumo em Inglês:

    Abstract The aim of this study was to assess the centralization and dentin thickness of mesial root canals of the first mandibular molars by microcomputed tomography (micro-CT). Material and methods: Ninety-nine mandibular molars of Vertucci's type IV canals were scanned by micro-CT. The mesiodistal deviation and centroid were assessed, in both mesiobuccal (MB) and mesiolingual (ML) canals, for the apical 4mm and the full canal length. Results: The dentin thickness was similar for both MB and ML canals. The narrowest thickness was in the distal wall of an MB canal (0.07mm), while the widest was found in the mesial wall of an MB canal (2.46mm). In centroid analysis, both the MB and ML canals exhibited deviations when compared to the root centroid, along the full canal length and the apical 4mm. For the MB canal, the mean deviation was 0.83mm (0.02 mm-2.30 mm) for the full canal and 0.18mm (0.01 mm-1.01 mm) for apical 4mm. Similarly, for the ML canal, the mean deviation measured 0.83 mm (0.05mm-3.99mm) for the full canal and 0.21 mm (0.01mm-1.01mm) for the apical 4 mm. Overall, deviations were observed towards the mesial of the roots, with 69% for MB and 57% for ML canals for the full canal, and 51% for MB canals within the 4 mm. The exception was the ML canal, which exhibited a higher deviation towards distal in the apical 4mm, accounting for 52% of cases. The dentin thickness was consistent between the mesial canals of mandibular molars. However, there is no centrality of mesial canals in their roots, with frequent deviation to mesial.
  • Root canal curvature influences uncontrolled removal of dentin and cleaning efficacy after ultrasonic activation Article

    Paiva, Hermano Camelo; Iglecias, Elaine Faga; Freire, Laila Gonzales; Candeiro, George Táccio de Miranda; Vieira, Basílio Rodrigues; Sousa, Frederico Barbosa de; Gavini, Giulio

    Resumo em Português:

    Resumo Este estudo avaliou a correlação entre a curvatura do canal radicular e os efeitos da irrigação ultrassônica nos seguintes parâmetros: volume de remoção não controlada de dentina (UDRVol), profundidade máxima do desgaste de dentina, remoção de debris de tecido duro acumulado (AHTD) e transporte em canais radiculares curvos. Vinte e quatro molares inferiores humanos permanentes foram divididos em dois grupos de acordo com a curvatura do canal radicular: curvatura moderada (MC: média de 25°); e curvatura acentuada (SC: média de 48°). Os espécimes foram digitalizados usando um scanner microcomputador de raios X (Skyscan 1172) antes e depois da limpeza e modelagem e após a irrigação ultrassônica. Houve uma correlação moderada entre o grau de curvatura do canal radicular e o volume de AHTD remanescente (p<0,05) e entre o grau de curvatura do canal radicular e a profundidade máxima de defeitos devido à remoção descontrolada de dentina (p<0,05). Os dentes do grupo SC apresentaram maior profundidade máxima de defeitos na parede dentinária no terço apical do que os dentes do grupo MC (p<0,05). Ambos os grupos tiveram uma redução significativa de AHTD em todos os terços do canal, mas a quantidade de AHTD remanescente nos terços médio e apical e em todo o canal foi significativamente maior no grupo SC do que no grupo MC (p <0,05). O transporte do canal não foi influenciado pela curvatura do canal em todos os terços (p > 0,05). Este estudo concluiu que a curvatura do canal radicular afeta significativamente a remoção descontrolada de dentina e o volume remanescente de AHTD após a irrigação ultrassônica.

    Resumo em Inglês:

    Abstract This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.
  • Impact of Access Cavity Design on Fracture Resistance of Endodontically Treated Maxillary First Premolar: In Vitro Article

    Daniel, Anju; Saleh, Abdul Rahman; Al-Jadaa, Anas; Kheder, Waad

    Resumo em Português:

    Resumo O objetivo deste estudo foi investigar o impacto do design da cavidade de acesso na resistência à fratura de primeiros pré-molares superiores tratados endodonticamente. MÉTODOS: A amostra do estudo consistiu em 72 primeiros pré-molares superiores intactos, divididos aleatoriamente em seis grupos (n = 12). Um preparo padronizado da cavidade proximal foi realizado para todas as amostras usando broca padrão. Grupos I: grupo de controle com apenas cavidade proximal padrão e sem acesso endodôntico, grupo II: cavidade de acesso Truss, grupo III: acesso separado aos canais vestibular e palatino sem remoção de dentina entre eles, grupo IV: acesso aos canais vestibular e palatino com remoção de dentina entre eles, grupo V: cavidade de acesso tradicional, grupo VI: cavidade mesio-oclusal-distal (MOD). Para os grupos I e VI, apenas a restauração de compósito foi usada para restaurar a cavidade proximal. Já nos grupos II e V, o acesso foi preparado e o tratamento endodôntico foi realizado em todos os dentes e, em seguida, foi colocada a restauração de resina composta. Os canais radiculares foram instrumentados com limas de níquel-titânio, irrigados com hipoclorito de sódio e preenchidos com AH plus sealer e guta-percha usando condensação vertical quente. Todas as amostras foram então colocadas em molde de acrílico e submetidas a envelhecimento térmico por 10.000 ciclos entre 5 e 55°C. As amostras foram fixadas em uma máquina de teste universal com o eixo longo das raízes posicionado a 20° para uma carga aplicada a uma velocidade de cruzeta de 1 mm/min usando indentador semiesférico de aço inoxidável (Ø = 3 mm) até que ocorresse a fratura para determinar a força de resistência à fratura em Newton. RESULTADOS: O teste de normalidade (Shapiro-Wilk) mostrou que os dados são normalmente distribuídos. O grupo II apresentou a maior resistência média à fratura, e o grupo VI foi o menos propenso a resistir à fratura. Não houve diferenças estatisticamente significativas entre os grupos testados (p-valor = 0,237). O grupo MOD apresentou um modo de fratura mais desfavorável em comparação com os outros grupos. CONCLUSÕES: Não houve diferença significativa na resistência à fratura entre as cavidades de acesso conservador e tradicional. A ausência de cristas marginais, como nas cavidades MOD, desempenhou um papel importante na diminuição da resistência à fratura dos dentes tratados endodonticamente.

    Resumo em Inglês:

    Abstract This study was designed to investigate the impact of access cavity designs on fracture resistance of endodontically treated maxillary first premolars. The study sample consisted of 72 intact maxillary first premolars, randomly divided into six groups (n = 12). A standardized proximal cavity preparation was prepared for all samples using standard bur. Groups I: control group with only standard proximal cavity and no endodontic access, group II: Truss access cavity, group III: Separated access to buccal and palatal canals without removal of dentine in between, group IV: Access to buccal and palatal canals with removal of dentine in between, group V: Traditional access cavity, group VI: Mesio-occlusal-distal cavity (MOD). For groups I and VI, only composite restoration was used to restore the proximal cavity, while for groups II- V, the access was prepared and endodontic treatment was performed on all teeth, then composite restoration was placed. The root canals were instrumented using nickel-titanium files, irrigated with sodium hypochlorite, and filled with AH plus sealer and gutta-percha using warm vertical condensation. All samples were then placed in an acrylic mold and underwent thermal aging for 10,000 cycles between 5 and 55°C. The samples were fixed in a universal testing machine with the long axis of the roots positioned at 20° to a load applied at a crosshead speed of 1 mm/min using a stainless steel semi-spherical indenter (Ø = 3 mm) until fracture occurred to determine the fracture resistance force in Newton. The normality test (Shapiro-Wilk) showed that data are normally distributed. Group II exhibited the highest mean fracture resistance, and group VI was the least likely to resist the fracture. No statistically significant differences between tested groups (p-value = 0.237). The MOD group showed a more unfavorable mode of fracture compared to other groups. No significant difference in fracture resistance between conservative and traditional access cavities. The missing marginal ridges, such as in MOD cavities played an important role in decreasing the fracture resistance of endodontically treated teeth.
  • Assessing peri-implant bone microarchitecture: conventional vs. osseodensification drilling - ex vivo analysis Article

    Bittar, Breno Fortes; Sotto-Maior, Bruno Salles; Devito, Karina Lopes; Rabelo, Gustavo Davi; Machado, Alessandra Silveira; Lopes, Ricardo Tadeu; Assis, Neuza Maria Souza Picorelli

    Resumo em Português:

    Resumo O objetivo deste estudo foi avaliar a estabilidade de implante e a microarquitetura óssea em duas técnicas de fresagem, comparando a técnica convencional (CT) e a osseodensificação (OD) (Versah Burs - Jackson - Mississippi - EUA). O torque de inserção do implante (IT), quociente de estabilidade primária (ISQ) e a estrutura trabecular peri-implantar foram avaliados em fragmentos ósseos obtidos de tíbia de porco (n=12), divididos entre CT (n=6) e OD (n=6). Após o procedimento de fresagem, foram instalados implantes (3,5x8,5 mm, Epikut - SIN - São Paulo - Brasil). O IT e o ISQ foram aferidos por meio de um torquimetro digital e análise de frequência de ressonância. Em seguida, os fragmentos ósseos contendo os implantes foram removidos com trefina e analisados ​​por microtomografia computadorizada (µCT, 8,0 µm). A comparação entre os grupos foi realizada por meio do teste-t não-pareado (α=0.05). Os resultados revelaram que a OD promove maior torque de inserção (CT: 7,67 ± 2,44º Ncm; OD: 19,78 ± 5,26 Ncm) (p=0,0005), embora a estabilidade primária não tenha sido diferente (CT: 61.33 ± 4.66; OD:63.25 ± 4.58) (p=0,48). Houve um aumento significativo no volume ósseo peri-implantar (CT: 23,17±3,39 mm3; OD: 32,01±5,75 mm3) (p=0,0089) e parâmetros trabeculares: separação (CT: 0,4357 ± 0,03 mm; OD: 0,3865 ± 0,04 mm) (p=0,0449), número (CT: 1,626 ± 0,18 1/mm; OD: 1,946 ± 0,13 1/mm) (p=0,007) e espessura (CT: 0,1130 ± 0,009 mm; OD: 0,1328 ± 0,015 mm) (p=0,02) O índice de modelo estrutural (SMI) não demostrou diferença estatisticamente significativa (p=0.1228). Concluindo, OD apresenta maiores valores de torque de inserção e promove mudanças benéficas na microarquitetura óssea em comparação com a TC, revelando maior volume ósseo peri-implantar.

    Resumo em Inglês:

    Abstract: The aim was to evaluate primary implant stability and bone microarchitecture in two drilling situations, by comparing the conventional technique (CT) and osseodensification (OD) (Versah Burs - Jackson - Mississippi - USA). The implant insertion torque (IT), implant stability quotient (ISQ), and the peri-implant trabecular microstructure were assessed on bone fragments obtained from pig’s tibia (n=12), divided between CT (n=6) and OD (n=6). After the drilling procedure, the implants were installed (3.5x8.5 mm, Epikut - SIN - São Paulo - Brazil). The IT and ISQ were measured using a digital torque wrench and resonance frequency analysis. Then, the bone fragments containing the implants were removed with a trephine and analyzed by Microtomography (µCT, 8.0 µm). The comparison between groups was performed using the unpaired t-test (α=0.05). The results revealed that OD promotes a higher insertion torque (CT: 7.67±2.44 Ncm; OD: 19.78±5.26 Ncm) (p=0.0005), although ISQ was not different (CT: 61.33±4.66; OD: 63.25±4.58) (p=0.48). There was a significant increase in peri-implant bone volume (CT: 23.17±3.39 mm3; OD: 32.01±5.75 mm3) (p=0.008), and trabecular parameters: separation (CT: 0.4357±0.03 mm; OD: 0.3865±0.04 mm) (p=0.0449), number (CT: 1.626±0.18 1/mm; OD: 1.946±0.13 1/mm) (p=0.007), and thickness (CT: 0.1130±0.009 mm; OD: 0.1328±0.015 mm) (p=0.02). Structure model index (SMI) data demonstrate no significant differences between groups (CT: 1.7±0.2; OD: 1.4±0.4) (p=0.12). In conclusion, OD increases the insertion torque values and promotes beneficial changes regarding bone microarchitecture compared with CT, revealing more peri-implant bone volume with consequent higher primary stability.
  • Effect of different thread configurations on hydrophilic implant stability. A split-mouth RCT Article

    Barbosa, Pablo Pádua; Oliveira, Vithor Xavier Resende de; Goulart, João Vitor; Margonar, Rogério; Moura, Marcos Boaventura de; Oliveira, Guilherme José Pimentel Lopes de

    Resumo em Português:

    Resumo O objetivo deste estudo controlado randomizado de boca dividida foi avaliar a estabilidade primária e secundária de implantes híbridos com diferentes configurações de rosca e superfícies hidrofílicas. Vinte pacientes com maxila parcialmente edêntula foram selecionados. Esses pacientes receberam dois tipos de implantes com a mesma superfície hidrofílica: Grupo CTP: Implante cilíndrico-cônico com roscas perfurantes; Grupo CTH: Implante cilíndrico-cônico com roscas perfurantes e condensadoras. Os parâmetros de estabilidade primária e secundária foram medidos por análise de torque de inserção e frequência de ressonância no momento da colocação do implante e 7, 28, 56 e 90 dias após o procedimento cirúrgico. O teste t-pareado foi utilizado para comparação dos dados de estabilidade entre os grupos. A análise estatística foi executada levando-se em consideração um nível de confiança de 95%. Constatou-se que os implantes do grupo CTH apresentaram maiores valores de estabilidade primária no momento da colocação do implante, devido ao maior ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) e torque de inserção (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), do que os implantes do grupo CTP. Implantes do grupo CTH apresentaram valores de ISQ superiores em todos os períodos de acompanhamento: 7 dias (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 dias (68.61 ± 5.98 vs. 47.90 ±13.10), 56 dias (74.09 ± 3.96 vs. 55.85 ± 13.18) e 90 dias (75.45 ± 4.02 vs. 63.47 ± 6.92). Os implantes híbridos com roscas perfurantes e condensantes demonstraram maior estabilidade do que os implantes híbridos com apenas roscas perfurantes.

    Resumo em Inglês:

    Abstract This split-mouth randomized controlled trial aimed to evaluate the primary and secondary stability of hybrid implants with different thread configurations and hydrophilic surfaces. Twenty patients with a partially edentulous maxilla were selected. These patients received two types of implants with the same hydrophilic surface: CTP group: Cylindrical-Tapered implant with perforating threads; CTH: Cylindrical-Tapered implant with hybrid threads configuration (perforating and condensing threads). The primary and secondary stability parameters were measured by insertion torque and resonance frequency analysis at the time of implant placement and 7, 28, 56, and 90 days after the surgical procedure. The paired t-test was used to compare the data on the implant's stability between the groups. The statistical analysis was performed with a confidence level set at 95%. It was found that the implants in the CTH group presented higher primary stability values ​​at the time of implant placement, due to the higher ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) and insertion torque (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), than the implants in the CTP group. The CTH group presented higher ISQ values ​​in all follow-up periods: 7 days (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 days (68.61 ± 5.98 vs. 47.90 ±13.10), 56 days (74.09 ± 3.96 vs. 55.85 ± 13.18), and 90 days (75.45 ± 4.02 vs. 63.47 ± 6.92) after implant placement. Hybrid implants with perforating and condensing threads demonstrated greater stability than hybrid implants with only perforating threads.
  • Effect of composite radiopacity and margin location of the restoration on the diagnosis of secondary caries Article

    Mosavat, Farzaneh; Ahmadi, Elham; Aghajani, Faezeh; Ramezani, Saeed

    Resumo em Português:

    Resumo Essa pesquisa teve como objetivo avaliar o efeito da radiopacidade de resina composta Bulk-Fill (X-TraFil, VOCO, Alemanha) e de resina composta convencional (P60, 3M ESPE, EUA) e a avaliação da localização da margem no esmalte e na dentina no diagnóstico de cárie secundária. 76 pré-molares intactos com preparo MOD foram divididos em dois grupos iguais e restaurados de acordo com o grupo experimental. Quatro regiões foram consideradas para simular lesões de cárie (duas regiões no esmalte e duas regiões na dentina). Em cada grupo, metade das regiões na dentina e metade no esmalte foram selecionadas aleatoriamente para a simulação de cárie secundária e preenchidas com uma combinação de cera e gesso, enquanto as regiões restantes permaneceram intactas. As imagens de bitewing foram feitas usando o sensor digital PSP. Cinco examinadores analisaram as imagens, e as lesões foram registradas. Os indicadores de diagnóstico de cárie e o teste t de amostra pareada foram usados para análise estatística. A reprodutibilidade e a precisão das respostas dos examinadores foram avaliadas usando o kappa e o coeficiente de concordância (α=0,05). A sensibilidade, a especificidade e a precisão do diagnóstico de lesões cariosas secundárias no esmalte foram significativamente melhores com a resina composta convencional do que com a resina composta bulk-fill. Da mesma forma, a sensibilidade e a precisão do diagnóstico de cáries secundárias na dentina foram significativamente maiores com a resina convencional do que com a resina bulk-fill (p<0,05). Não foram encontradas diferenças significativas na concordância e no coeficiente kappa entre as resinas convencionais e bulk-fill no esmalte e na dentina (p>0,05). A precisão do diagnóstico de lesões cariosas foi maior com a resina composta convencional do que com a resina composta bulk-fill. Entretanto, a localização do secundário foi ineficaz no diagnóstico de cárie.

    Resumo em Inglês:

    Abstract This research aimed to evaluate the effect of the radiopacity of a Bulk-Fill composite (X-TraFil, VOCO, Germany) and a Conventional composite (P60, 3M ESPE, USA) and assessment of the margin location in the enamel and dentin on the diagnosis of secondary caries. 76 intact premolars with MOD preparation were divided into two equal groups and filled with the conventional and bulk-fill composite. Four regions were considered to simulate carious lesions (two regions in enamel and two regions in dentin). In each group, half of the regions in the dentin and half in the enamel were randomly selected for secondary caries simulation and filled with a wax-plaster combination while the remaining regions stayed intact. Bitewing imaging was done using the PSP digital sensor. Five examiners reviewed the images, and lesions were recorded. Caries diagnosis indicators and paired-sample t-test were used for statistical analysis. The reproducibility and accuracy of the examiners’ responses were evaluated using the kappa and agreement coefficient (α=0.05). The sensitivity, specificity, and accuracy of diagnosing secondary carious lesions in enamel were significantly better under conventional than bulk-fill composite. Similarly, the sensitivity and accuracy of diagnosing secondary caries in dentin were significantly higher under conventional composite than bulk-fill composite (p<0.05). No significant differences were found in the agreement and kappa coefficient between conventional and bulk-fill composites in the enamel and dentin (p>0.05). The diagnostic accuracy of carious lesions was higher under conventional composite than bulk-fill composite. However, the location of the secondary was ineffective in caries diagnosis.
  • Effect of Ceramic Thickness on the Bond Strength to Resin-Luting Agents before and after Thermal Cycling Article

    Souza, Carolina Rodrigues de; Costa, Ana Rosa; Borges, Lincoln Pires Silva; Ferraz, Analia Gabriella Borges; consani, Rafael Leonardo Xediek; Pacheco, Rafael Rocha; Correr, Américo Bortolazzo; Correr-Sobrinho, Lourenço

    Resumo em Português:

    Resumo: Este estudo investigou a resistência de união ao microcisalhamento (RUµC) de dois (2) agentes de cimentação de resina dual (RelyX™ Ultimate e RelyX™ U200) quando fotoativados através de diferentes espessuras de dissilicato de lítio, com ou sem ciclagem térmica. Discos do IPS e.max Press de 0,5, 1,5 e 2 mm de espessura foram obtidos. Moldes de elastômero (3,0 mm de espessura) com quatro orifícios cilíndricos de 1,0 mm de diâmetro foram colocados sobre as superfícies cerâmicas e preenchidos com agentes de cimentação de resina. Uma tira Mylar, placa de vidro e carga de 250 gramas foram colocadas sobre o molde preenchido. A carga foi removida e os agentes de cimentação resinosos foram fotoativados através da cerâmica usando um LED de pico-único (Radii Plus). Todas as amostras foram armazenadas em água deionizada a 37oC por 24 h. Metade das amostras foi submetida a ciclagem térmica (3.000 ciclos; 5ºC e 55ºC). Todas as amostras foram então submetidas ao teste de RUµC usando uma máquina de teste universal (Instron 4411) com velocidade de 0,5 mm/min. Os dados foram submetidos à Análise de Variância três fatores e ao teste post-hoc de Tukey (α = 0,05). A média de RUµC em 24 h foi significativamente maior do que após a ciclagem térmica (p < 0,05). Não houve diferença estatística entre os cimentos resinosos (p > 0,05). As médias de RUµC para grupos fotoativados através de cerâmica de 0,5 mm foram significativamente maiores do que 1,5 mm e 2,0 mm (p < 0,05). Em conclusão, o aumento da espessura da cerâmica reduziu a resistência de união dos agentes de cimentação resinosos ao dissilicato de lítio. Não foram encontradas diferenças entre os agentes de cimentação resinosos. A ciclagem térmica reduziu a resistência de união de ambos os agentes de cimentação resinosos.

    Resumo em Inglês:

    Abstract This study investigated microshear bond strength (µSBS) of two (2) dual-cured resin-luting agents (RelyX™ Ultimate and RelyX™ U200) when photoactivated through varying thicknesses of lithium disilicate, with or without thermal cycling. Discs of IPS e.max Press of 0.5, 1.5, and 2 mm in thickness were obtained. Elastomer molds (3.0 mm in thickness) with four cylinder-shaped orifices 1.0 mm in diameter, were placed onto the ceramic surfaces and filled with resin-luting agents. A Mylar strip, glass plate, and load of 250 grams were placed over the filled mold. The load was removed and the resin-luting agents were photoactivated through the ceramics using a single-peak LED (Radii Plus.) All samples were stored in distilled water at 37oC for 24 h. Half of the samples were subjected to thermal cycling (3,000 cycles; 5ºC and 55ºC). All samples were then submitted to µSBS test using a universal testing machine (Instron 4411) at a crosshead speed of 0.5 mm/min. Data were submitted to three-way ANOVA and Tukey post-hoc test (α=0.05). The mean µSBS at 24 h was significantly higher than after thermal cycling (p<0.05). No statistical difference was found between resin-luting agents (p > 0.05). The mean µSBS for groups photoactivated through 0.5 mm ceramic were significantly higher than 1.5 mm and 2.0 mm (p < 0.05). In conclusion, increased ceramic thicknesses reduced the bond strength of tested resin-luting agents to lithium disilicate. No differences were found between resin-luting agents. Thermal cycling reduced the bond strength of both resin-luting agents.
  • Surface treatments of the zirconia-reinforced lithium disilicate ceramic in the adhesion to the resin cement Article

    Aguilera, Mirko A.R.; Bortolazzo, Américo C.; Correr-Sobrinho, Lourenço; Consani, Rafael L. X.

    Resumo em Português:

    Resumo O objetivo neste estudo foi verificar o efeito de tratamentos de superfície da cerâmica de dissilicato de lítio reforçada com zircônia fixada ao cimento resinoso. Os blocos cerâmicos foram separados de acordo com os tratamentos (n=10): AF+SRX (ácido fluorídrico + silano), AF+MDP (ácido fluorídrico + MDP), AF+SCF+MDP (ácido fluorídrico + silano + MDP), AF+MEP (Ácido fluorídrico + MEP) e MEP (Primer auto condicionante). Cilindros de cimento resinoso foram confeccionados em cada bloco cerâmico, foto ativados com 1.200 mW/cm² por 40 segundos, armazenados em água a 37°C por 24 horas e avaliados pelo teste de resistência ao micro cisalhamento, falha por análise descritiva em microscopia óptica (%), caracterização da superfície por imagens MEV e ângulo de contato (Goniômetro). Outras amostras foram submetidas a 10.000 ciclos térmicos (5° e 55°C). Os dados de resistência de união foram submetidos a ANOVA dois fatores e teste de Tukey (5%). Ângulo de contato com ANOVA um fator e teste de Games-Howell (5%). Em 24 horas, MEP apresentou maior resistência de união e AF+S a menor. AF+MDP e AF+SCF+MDP apresentaram valores similares e AF+MEP foi intermediário. Após a ciclagem térmica, AF+SCF+MDP, AF+MEP e MEP apresentaram valores maiores e AF+SRX o menor enquanto AF+MDP foi intermediário. Quando comparados os períodos, AF+MDP, AF+SCF+MDP, AF+MEP e MEP apresentaram valores maiores em 24 horas enquanto AF+SRX foi similar. MEV mostrou superfície mais retentiva e exposição de cristais quando tratada com AF+SCF+MDP. A superfície menos retentiva foi obtida com MEP, e os demais tratamentos promoveram irregularidades de superfície intermediárias. Conclui-se que o tratamento superficial e a termociclagem promoveram diferentes valores de resistência adesiva e ângulo de contato em cerâmica de silicato de lítio reforçada com zircônia. As falhas foram predominantemente adesivas, e a superfície cerâmica foi caracterizada com diferentes níveis de rugosidade e exposição seletiva de cristais.

    Resumo em Inglês:

    Abstract This study verified the effect of surface treatments of the zirconia-reinforced lithium disilicate ceramic bonded to resin cement. Ceramic blocks were divided according to treatments (n=10): FA+SRX (Fluoric acid + silane RX), FA+MDP (Fluoric acid + MDP), FA+SCF+MDP (Fluoric acid + silane CF + MDP), FA+MEP (Fluoric acid + MEP), and MEP (Self-etch primer). Resin cement cylinders were made in the ceramic blocks, photoactivated with 1,200 mW/cm² for 40s, stored in water at 37°C for 24h, and evaluated by the microshear strength test, optical failure descriptive analysis (%), surface characterization (SEM) and contact angle (Goniometer). Other samples were submitted to 10,000 thermocycles between 5°C and 55°C. Bond strength data were submitted to two-way ANOVA and Tukey’s test. Contact angle to one-way ANOVA and Games-Howell's test (5%). At 24h, MEP showed higher bond strength, and FA+SRX the lower. FA+MDP and FA+SCF+MDP showed similar values and FA+MEP was intermediate. After thermocycling, FA+SCF+MDP, FA+MEP, and MEP showed higher values, and FA+SRX the lower while FA+MDP was intermediate. When the periods were compared, FA+MDP, FA+SCF+MDP, FA+MEP, and MEP showed higher values for 24h while FA+SRX was similar. SEM showed retentive surface and crystal exposure when treated with FA+SCF+MDP. The less retentive surface was obtained with MEP, and the other treatments promoted intermediate irregularities. In conclusion, surface treatment and thermocycling promoted different values of adhesive strength and contact angle in a zirconia-reinforced lithium silicate ceramic. Failures were predominantly adhesive, and the ceramic surface was characterized by different levels of roughness and selective exposure of crystals.
  • Comparative study of physical-chemical properties of bioactive glass ionomer cement Article

    Ramos, Nádia Buzignani Pires; Felizardo, Klissia Romero; Berger, Sandrine Bittencourt; Guiraldo, Ricardo Danil; Lopes, Murilo Baena

    Resumo em Português:

    Resumo Este estudo analisou as propriedades físico-químicas dos materiais de ionômero bioativo. Os materiais bioativos Cention N quimicamente ativados (CN) e fotopolimerizados (CN-LC), Equia Forte Fill (EQUI); resina composta convencional Filtek Z350 XT (Z350); resina de ionômero de vidro Riva light Cure (RIVA) e resina composta fluida Filtek Bulk Fill Flow (BULK-F) foram avaliados. Sessenta espécimes (n=10) foram preparados para testes de sorção (SR), solubilidade (SL), resistência à flexão (FS), tensão de contração (SS), grau de conversão (CD), microdureza (MI) e rugosidade da superfície (SR). Os materiais não curados e curados com luz foram avaliados por FTIR. 30 dentes molares humanos foram usados no teste de resistência de união (BS). Os dados foram submetidos a ANOVA e teste de post-hoc Tukey (5% de significância). O EQUI apresentou maior sorção no SR e não mostrou diferença estatística em relação aos grupos RIVA e CN-LC. O grupo CN apresentou maior solubilidade e o EQUI apresentou menor (p<0,05). O BULK-F apresentou maior FS (MPa), sem diferir do CN e do Z350, enquanto o EQUI apresentou o menor FS, não diferindo do RIVA. O BULK-F e o CN-LC apresentaram maior estresse de contração, diferindo do EQUI. O CN-LC e o CN apresentaram maior CD (%), diferindo dos demais, que não apresentaram diferenças (p>0,05) entre si. A EQUI apresentou a maior dureza (p<0,05) no MI. Não houve diferenças (p>0,05) na SR (µm). Z350 and BULK-F apresentaram BS, enquanto a CN-LC apresentou a menor, embora não diferindo da EQUI e da RIVA. A solubilidade e a microdureza do Equia Forte o tornam uma boa alternativa como material restaurador. O grau de conversão e a resistência à flexão do Cention N o tornam uma opção estética ao amálgama.

    Resumo em Inglês:

    Abstract This study analyzed the physical-chemical properties of bioactive ionomer materials. Cention N bioactive materials were evaluated chemically activated (CN) and light-cured (CN-LC), Equia Forte Fill (EQUI); conventional resin composite Filtek Z350 XT (Z350); resin glass ionomer cement Riva light Cure (RIVA) and flowable resin composite Filtek Bulk Fill Flow (BULK-F) were evaluated. Sixty specimens (n=10) were prepared for sorption (SR), solubility (SL), flexural strength (FS), shrinkage stress (SS), conversion degree (CD), microhardness (MI), and surface roughness (SR) tests. Non-cured and light-cured materials were assessed on FTIR. 30 human molar teeth were used in the bond strength test (BS). Data were subjected to ANOVA and post-hoc Tukey’s test (5% of significance). EQUI showed more sorption in SR and no statistical difference from RIVA and CN-LC. CN group showed more solubility and EQUI presented less (p<0.05). BULK-F showed higher FS (MPa), without differences from CN and Z350, whereas EQUI presented the lowest FS not differing from RIVA. BULK-F and CN-LC showed more shrinkage stress differing from EQUI. CN-LC and CN showed higher CD differing from the other which showed no differences (p>0.05) between them. EQUI showed the highest hardness (p<0.05) in MI. There were no differences (p>0.05) in SR (µm). Z350 and BULK-F presented higher BS, whereas CN-LC showed the lowest, although not differing from EQUI and RIVA. Equia Forte's solubility and microhardness make it a good alternative as a restorative material. Cention N degree of conversion and flexural strength making it an esthetic option to amalgam.
  • Preheated acid associated with silane and electric current in the adhesion of the resin cement to ceramic Article

    Casaburi, Gustavo Belmiro; Silva, Marcos Henrique Ramos da; Correr-Sobrinho, Lourenço; Consani, Rafael Leonardo Xediek

    Resumo em Português:

    Resumo Este estudo verificou o efeito da combinação ácido fluorídrico pré-aquecido/silano/corrente elétrica na adesão do cimento resinoso à cerâmica. Os discos cerâmicos IPS E.max Press embutidos em tubos rígidos de PVC foram separados em quatro grupos associando ácido fluorídrico pré-aquecido e silano aplicado com corrente elétrica (n=10): Ha+S (ácido aquecido + silano); Ha+S+Ec (Ácido aquecido + silano + corrente elétrica); A+S (Ácido + silano) e A+S+EC (Ácido + silano + corrente elétrica). Amostras de cimento resinoso/cerâmica foram armazenadas em água a 37°C por 24 horas. Após o armazenamento foram submetidas ao ensaio de micro cisalhamento, análise de fratura e ângulo de contato no período de 24 horas ou após termociclagem (10.000 ciclos/5-55ºC). Os dados de resistência de união foram avaliados por ANOVA dois fatores. Para comparação entre os tempos de avaliação (24 horas ou termociclagem) foi aplicado o teste t não pareado. Foi assumida significância de 5% para análises e gráficos (software GraphPad Prism 9.0). Em 24 horas, a resistência ao micro cisalhamento apresentou valores similares entre os grupos Ha+S, Ha+S+Ec e A+S+Ec, enquanto A+S apresentou menor valor com diferença estatística. Após a termociclagem, Ha+S e Ha+S+Ec foram similares, assim como A+S e A+S+Ec. Houve diferença significativa em todos os grupos comparando 24 horas (maior valor) com após termociclagem (menor valor). A fratura adesiva foi predominante em todos os grupos e tempos de avaliação. Os grupos Ha+S e A+S apresentaram maiores valores de ângulos de contato comparados aos grupos Ha+S+Ec e A+S+Ec com valores menores. Em conclusão, a associação ácido fluorídrico pré-aquecido/silano aplicado com corrente elétrica promoveu diferentes valores de resistência ao micro cisalhamento, tipos de fratura e ângulos de contato na adesão do cimento resinoso à cerâmica.

    Resumo em Inglês:

    Abstract This study verified the effect of the combination of preheated hydrofluoric acid/silane/electric current in the adhesion of the resin cement to ceramic. IPS E.max Press ceramic discs embedded in PVC rigid tubes were divided into four groups associating preheated hydrofluoric acid and silane applied with electrical current (n=10): Ha+S (Heated acid + silane); Ha+S+Ec (Heated acid + silane + electrical current); A+S (Acid + silane) and A+S+Ec (Acid + silano + electrical current). Resin cement/ceramic samples were stored in water at 37°C for 24h. After storage, they were submitted to the microshear test, fracture analysis, and contact angle at 24h or after thermocycling (10,000 cycles/5-55ºC). Bond strength data were evaluated by two-way ANOVA. For comparison between evaluation times (24h or thermocycling) was applied unpaired t-test. A significance post-hoc test of p=0.05 was assumed for analyses and graphs (GraphPad Prism 9.0 software). At 24h, the microshear strength showed similar values between Ha+S, Ha+S+Ec, and A+S+Ec groups, while A+S showed the lowest value with a statistical difference. After thermocycling, Ha+S and Ha+S+Ec were similar, as well as A+S and A+S+Ec. There was a significant difference in all groups comparing 24h (highest value) with after thermocycling (lowest value). Adhesive fracture was predominant in all groups and evaluation times. Ha+S and A+S groups showed higher contact angle values compared to the Ha+S+Ec and A+S+Ec with lower values. In conclusion, the association of preheated hydrofluoric acid/silane applied or not with electric current promoted different microshear strength values, fracture types, and contact angles in the resin cement/ceramic bond.
  • Color matching and color recovery in large composite restorations using single-shade or universal composites Article

    Rosa, Ellen Dionélia Alencar Rodrigues; Silva, Larissa Fernandes Vieira Da; Silva, Paula Fernanda Damasceno; Silva, André Luís Faria e

    Resumo em Português:

    Resumo Este estudo avaliou a habilidade de combinação de cores e recuperação de cor de dentes não preparados ao utilizar resinas compostas de única tonalidade e uma resina composta universal em grandes restaurações. As cores das superfícies bucais e palatinas de molares foram medidas com um espectrofotômetro (CIELAB) antes de preparar cavidades esféricas (6 mm de diâmetro, 2 mm de profundidade). As cavidades foram preenchidas aleatoriamente com uma resina composta de única tonalidade (Omnichroma, Diamond One ou Vittra APS Unique) ou com uma resina composta universal (Filtek Universal). Foram realizadas medições das cores das cavidades restauradas e calculadas as diferenças de cor globais (ΔEab and ΔE00)) e as diferenças no índice de clareamento para odontologia (ΔWID) em relação à cor inicial. Além disso, foram realizadas avaliações visuais da correspondência de cor com o esmalte circundante por quarenta avaliadores (leigos e estudantes de odontologia) em uma cabine de visualização sob iluminante D65, com pontuações de 0 (nenhuma discrepância de cor) a 4 (não aceitável). Os dados foram analisados usando RM ou ANOVA unidirecional (α = 0,05). Os resultados mostraram que as restaurações geralmente apresentavam cores mais brancas (WID variou de 27,9 a 41,3) do que os dentes não preparados (WID variou de 15,9 a 19,3). A resina composta Filtek Universal demonstrou a menor discrepância de cor (ΔWID = 8,6; ΔE00 = 10,8; and ΔE00 = 6,2), e não foram observadas diferenças significativas entre as resinas compostas de única tonalidade avaliadas. Além disso, todas as resinas compostas apresentaram correspondência de cor similar e adequada com o esmalte circundante. No entanto, é importante observar que, apesar de sua capacidade de corresponder razoavelmente com o esmalte circundante, nenhuma das resinas compostas avaliadas em grandes restaurações recuperou completamente a cor observada nos dentes não preparados.

    Resumo em Inglês:

    Abstract This study assessed the color-matching ability and color recovery of unprepared teeth when using single-shade composites and a universal composite in large restorations. Buccal and palatine surface colors of molars were measured with a spectrophotometer (CIELAB) before preparing round cavities (6 mm in diameter, 2 mm in depth). The cavities were randomly filled with a single-shade composite (Omnichroma, Diamond One, or Vittra APS Unique) or a universal composite (Filtek Universal). Color measurements of the restored cavities were taken, and overall color differences (ΔEab and ΔE00) and differences in the whitening index for dentistry (ΔWID) from baseline were calculated. Additionally, visual assessments of a color match to the surrounding enamel were performed by forty evaluators (laypersons and undergraduate students of dentistry) in a viewing booth under illuminant D65, with rating scores from 0 (no color mismatch) to 4 (not acceptable). Data were analyzed using RM or one-way ANOVA (α = 0.05). Results showed that the restorations generally exhibited whiter colors (WID ranged from 27.9 to 41.3) than the unprepared teeth (WID ranged from 15.9 to 19.3). The composite Filtek Universal demonstrated the lowest color discrepancy (ΔWID = 8.6; ΔE00 = 10.8; and ΔE00 = 6.2), and no significant differences were observed among the evaluated single-shade composites. Furthermore, all composites showed similar and adequate color matches to the surrounding enamel. However, it is important to note that despite their ability to match the surrounding enamel reasonably, none of the composites evaluated in large restorations fully recovered the color observed in unprepared teeth.
  • Effect of ZrO2 paste, surface treatments, and storage on Weibull characteristics and resin bond strength to zirconia Article

    Crispim, Anne Heloyse Teixeira; Silva, Sarah Emille Gomes da; Moreira, Fernanda Gurgel de Gois; Silva, Bianca Cristina Dantas da; Piva, Amanda Maria de Oliveira Dal; May, Liliana Gressler; Daudt, Natália de Freitas; Souza, Rodrigo Othávio Assunção

    Resumo em Português:

    Resumo O objetivo é avaliar o efeito de diferentes tratamentos superficiais e do envelhecimento na resistência ao cisalhamento da zircônia ultratranslúcida. Foram confeccionados 36 blocos de zircônia ultratranslúcida (7x7x2mm) e sinterizados. Em seguida, divididos em 12 grupos de acordo com o “tratamento de superfície” (C-Primer; Al-Jateamento com Al2O3+Primer; Si-Silicato+Primer; Gl -Glaze+HF+Primer; Z-Zirlink; Zp-Zirlink+Primer) e fatores de “armazenamento” (ST-com, 150 dias/37º e sem). Após o tratamento superficial, foram construídos cinco cilindros (Ø=2mm; h=2,0mm) de cimento resinoso (n=15) em cada bloco cerâmico; ao final foi realizado o ensaio de resistência ao cisalhamento (1mm/min, 50Kgf) e análise de falhas superficiais. Foram confeccionadas 60 amostras adicionais (2x2x2mm) para análises extras (rugosidade superficial, MEV e EDS). Os dados de resistência de união e rugosidade superficial foram avaliados estatisticamente por ANOVA (2 fatores/1fator), teste de Tukey (5%) e análise de Weibull, respectivamente. ANOVA (2 fatores) revelou que todos os fatores foram estatisticamente significativos para a resistência de união. Os grupos de silicatização (SiST: 30,47AMPa; Si: 29,21AMPa) apresentaram os maiores valores de resistência de união, independente do armazenamento (Tukey). Enquanto os grupos tratados com Zirlink (ZST: 2,76FMPa; Z: 5,27EFMPa) apresentaram os valores mais baixos, apenas semelhantes ao grupo GlST (5,14EFMPa). O módulo de Weibull (m) apresentou diferença estatística entre os grupos (p=0,000). A ANOVA (1 fator) revelou que o fator “tratamento superficial” (p=0,0000) foi estatisticamente significativo para rugosidade superficial. Portanto, a aplicação de Zirlink e do Glaze na zircônia pré-sinterizada não promoveu adesão eficiente da zircônia ultratranslúcida ao cimento resinoso, mesmo quando associada a primer contendo MDP.

    Resumo em Inglês:

    Abstract The objective is to evaluate the effect of different surface treatments and storage on the shear strength of ultratranslucent zirconia. 36 blocks of ultra-translucent zirconia were fabricated (7x7x2mm) and sintered. Then, divided into 12 groups according to the “surface treatment” (C -Primer; Al -Sandblasting with Al2O3 + Primer; Si -Silicate + Primer; Gl -Glaze + HF + Primer; Z -Zirlink; Zp -Zirlink + Primer) and “storage” factors (ST-with 150 days/37º and without). After surface treatment, five cylinders (Ø=2mm; h=2.0mm) of resin cement (n=15) were constructed in each ceramic block; at the end, the shear strength test was performed (1mm/min, 50Kgf), and analysis of surface failures. 60 additional samples (2x2x2mm) were made for extras analysis (surface roughness, MEV, and EDS). Bond strength and surface roughness data were statistically evaluated by ANOVA (2 factors/1 factor), Tukey test (5%), and Weibull analysis, respectively. ANOVA (2-way) revealed that all factors were statistically significant for bond strength. The silicatization groups (SiST: 30.47AMPa; Si: 29.21AMPa) showed the highest bond strength values, regardless of storage (Tukey's test). While the groups treated with Zirlink (ZST: 2.76FMPa; Z: 5.27EFMPa) showed the lowest values, just similar to the GlST group (5.14EFMPa). The Weibull modulus (m) showed a statistical difference between groups (p=0.000). ANOVA (1 factor) revealed that the "surface treatment" factor (p=0.0000) was statistically significant for surface roughness. Therefore, the application of Zirlink and Glaze on pre-sintered zirconia did not promote efficient adhesion of the ultratranslucent zirconia to the resin cement, even when associated with a primer containing MDP.
  • Evaluation the stress distribution in root canals by 3D finite element analysis after the materials used in reattaching the vertically root fractured fragments Article

    Özer, Senem Yiğit; Danişman, Salih; Özer, Törem

    Resumo em Português:

    Resumo O objetivo foi avaliar o efeito da distribuição de estresse nas forças verticais, horizontais e oblíquas no modelo de dente após a recolocação dos fragmentos do incisivo superior com fratura radicular vertical (FRV) usando diferentes materiais, por meio da análise de elementos finitos (FEA) em 3D. Métodos: Foram projetados modelos de dentes com canal radicular, osso esponjoso e cortical. A FRV foi modelada em um dente com 4 modelos diferentes de reataque, como Grupo 1: cimento de cura dupla (DC) + compósito reforçado com fibra (FRC), Grupo 2: DC + fibra de polietileno, Grupo 3: DC + fibra de vidro e Grupo 4: DC. Foi aplicada uma força de 100 N em 3 direções diferentes. As tensões principais máximas (σmax) da dentina e os materiais de recolocação foram avaliados em imagens coloridas. Resultados: Os valores mais altos de σmax foram registrados nos materiais de reparo sob forças verticais para os Grupos 1 e 4, respectivamente; os Grupos 2 e 3 apresentaram semelhança. Os valores mais altos de σmax nos materiais de reparo sob forças horizontais e oblíquas foram observados no Grupo 3; no entanto, os valores mais baixos de σmax nos materiais de reparo sob forças oblíquas e horizontais foram observados no Grupo 1. Os valores de tensão nos materiais de reparo aumentaram gradualmente, respectivamente, começando da holizontal para a vertical. À medida que o módulo de elasticidade dos materiais de reparo aumentava, os valores de tensão na dentina da raiz aumentavam. Em todas as direções de força, exceto nas forças verticais, foram observados valores de tensão mais baixos com o FRC. Conclusões: a resistência à fratura foi maior quando se utilizou apenas FRC ou cimento resinoso de cura dupla em comparação com os designs com suporte de fibra. A adição de fibra de polietileno às restaurações diminuiu os valores de tensão em comparação com a adição de fibra de vidro. Portanto, ao adicionar fibras, a fibra de polietileno será vantajosa.

    Resumo em Inglês:

    Abstract The aim was to evaluate the effect of stress distribution on vertical, horizontal, and oblique forces on the tooth model after reattaching the fragments of the maxillary incisor with vertical root fracture (VRF) using different materials, by 3D finite element analysis (FEA). Tooth with a root canal, spongious, and cortical bone models were designed. VRF was modeled on a tooth with 4 different re-attachment models: Group 1: dual-cure cement (DC)+fiber reinforced composite (FRC), Group 2: DC+polyethylene fiber, Group 3: DC+glass fiber, and Group 4:DC. 100 N force was applied in 3 different directions. Maximum principal stresses (σmax) of dentin, and re-attachment materials were evaluated on colored images. The highest σmax values ​​were on the repair materials under vertical forces for Groups 1 and 4, respectively; Groups 2 and 3 showed similarity. The highest σmax values in repair materials under horizontal and oblique forces were observed in Group 3 however the lowest σmax values in repair materials under oblique and horizontal forces were observed in Group 1. The stress values ​​on repair materials gradually increased respectively starting from horizontal to vertical. As the elasticity modulus of the repair materials increased, the stress values ​​on root dentin increased. Through all force directions, except vertical forces, lower stress values were observed with FRC. The fracture resistance was bigger when using solely FRC or dual-cure resin cement in comparison to fiber-supported designs. Adding polyethylene fiber to re-restorations decreased stress values ​​compared to glass fiber addition. Therefore, when adding fibers, polyethylene fiber will be advantageous.
Fundação Odontológica de Ribeirão Preto Av. do Café, S/N, 14040-904 Ribeirão Preto SP Brasil, Tel.: (55 16) 3602-3982, Fax: (55 16) 3633-0999 - Ribeirão Preto - SP - Brazil
E-mail: bdj@forp.usp.br