Acessibilidade / Reportar erro

Action of peracetic acid on Escherichia coli and Staphylococcus aureus in suspension or settled on stainless steel surfaces

Ação do ácido peracético na destruição de Staphylococcus aureus e Escherichia coli em suspensão ou sedimentados sobre uma superfície de aço inoxidável

The efficiency of a commercial peracetic acid sanitizer on destruction of Staphylococcus aureus and Escherichia coli was evaluated using two distinct methods. The first method is the AOAC suspension test and the second is a method proposed by one of the authors in which the microbial cells are settled on a stainless steel surface and then treated with the sanitizer. The results showed that when in suspension S. aureus was more resistant to the sanitizer than E. coli. When S. aureus was settled on the stainless steel surface, the contact time between the sanitizer and the microorganisms to attain a 6.5 log reduction in the number of viable cells was three times greater than when the cells were in suspension.

peracetic acid; Staphylococcus aureus; Escherichia coli; stainless steel surface; sanitizers


Sociedade Brasileira de Microbiologia USP - ICB III - Dep. de Microbiologia, Sociedade Brasileira de Microbiologia, Av. Prof. Lineu Prestes, 2415, Cidade Universitária, 05508-900 São Paulo, SP - Brasil, Ramal USP 7979, Tel. / Fax: (55 11) 3813-9647 ou 3037-7095 - São Paulo - SP - Brazil
E-mail: bjm@sbmicrobiologia.org.br