Neutron anisotropy and X-ray production of the FN-II dense plasma focus device

Abstract

The FN-II Dense Plasma Focus is a small (< 5kJ ) Mather type device, where the dependence of neutron yield and its anisotropy, in terms of deuterium filling pressure, and the neutron emission angular distribution have been studied. Two diferent electrode configurations have been tested, showing that their geometry plays an important role both on neutron yield and anisotropy. Time integrated anisotropy has been measured with silver activation counters, on a shot to shot basis. CR-39 nuclear track detectors are used to determine the angular distribution of neutrons, averaged over tens of shots, showing that an isotropic pedestal accounts for 70% of the emission, while the anisotropy component accounts for the remaining 30%. The neutron yield shows a tendency to increase with anisotropy, as well as with the emission of hard X-rays observed on-axis. Scintillator- photomultiplier detectors show a slight Doppler shift in the neutron energy at backward angles, supporting the beam-target mechanism. Additional information has been obtained from time inte- grated X-ray diagnostics, which include filtered multi-pin-hole cameras.


Neutron Anisotropy and X-Ray Production of the FN-II Dense Plasma Focus Device

F. Castillo, J.J.E. Herrera, J. Rangel, A. Alfaro, M.A. Maza, V. Sakaguchi,

Instituto de Ciencias Nucleares

Universidad Nacional Autónoma de México

A.P.70-543, Ciudad Universitaria, 04511 México, D.F. México

G. Espinosa, and J.I.Golzarri

Instituto de Física

Universidad Nacional Autónoma de México

A.P. 20-364, 01000 México, D.F. México

Received on 26 June, 2001

The FN-II Dense Plasma Focus is a small (< 5kJ ) Mather type device, where the dependence of neutron yield and its anisotropy, in terms of deuterium filling pressure, and the neutron emission angular distribution have been studied. Two diferent electrode configurations have been tested, showing that their geometry plays an important role both on neutron yield and anisotropy. Time integrated anisotropy has been measured with silver activation counters, on a shot to shot basis. CR-39 nuclear track detectors are used to determine the angular distribution of neutrons, averaged over tens of shots, showing that an isotropic pedestal accounts for 70% of the emission, while the anisotropy component accounts for the remaining 30%. The neutron yield shows a tendency to increase with anisotropy, as well as with the emission of hard X-rays observed on-axis. Scintillator- photomultiplier detectors show a slight Doppler shift in the neutron energy at backward angles, supporting the beam-target mechanism. Additional information has been obtained from time inte- grated X-ray diagnostics, which include filtered multi-pin-hole cameras.

I Introduction

The Dense Plasma Focus (DPF) has been studied since the late 1950's, and its research has been stimulated from its early days because of the simplicity of its engineering, and its properties as an intense, pulsed, low cost, source of neutrons, electron and ion beams, as well as of soft and hard x-rays [1-3]. Although some projections maintain the DPF might still be considered a feasible candidate for a controlled fusion reactor [2, 4], most of the recent work has been motivated by ongoing interest as a cost effective pulsed neutron and x-ray source for a wide range of applications [5-9].

The DPF is a coaxial gun, in which the inner electrode, the anode, is electrically insulated from the outer electrode, the cathode, by ceramics or Pyrex. After achieving a high vacuum, gas is admitted at a pressure of a few torr. The plasma originates when a capacitor bank is discharged through a low inductance transmission line, as spark or rail gap switches are closed within a few ns rise time. As the discharge breaks down at the breech of the gun, through the insulator surface, a radial current sheath develops, giving rise to an azimuthal magnetic field, which drives the sheath towards the muzzle. As a result, the sheath sweeps and ionises the neutral gas it finds on its way. Finally, it focuses into a plasma column at the tip of the inner electrode, with densities in the range of 1018-1020cm-1, and electron temperatures in the range of 0.1-2.0keV, depending on the dimensions of the device and the energy stored in the capacitor bank. Confinement is achieved by the pinch effect, due to the axial current, which ranges from 200 kA in small devices up to 2 MA in the largest ones. During this phase, soft X rays are produced by bremsstrahlung. The filling gas can be chosen in order to produce strong line radiation, and thus hard X-rays [10]. The tip of the electrode can be designed in such a way that the impinging electron beam can enhance them.

It is well known from the early days of fusion research that the z-pinch is a magnetohydrodinamically unstable configuration, and that the plasma column is destroyed, usually within 10-50 ns. In the process of such instabilities, ions are accelerated away from the anode, while electrons are accelerated into it, associated with the appearence of hot-spots [11]. A reasonable hypothesis is that strong electric fields are generated, which accelerate ions up to energies greater than 10 MeV, even in small devices [12-15]. Unfortuantely, discrepancies between conflicting theories have not been solved yet by experimental evidence. Such issue of outmost importance falls beyond the scope of the present paper. If the filling gas is deuterium in a DPF, the accelerated ions react against the background hot dense plasma ions, originating a notorious neutron pulse that ranges from 106 per shot in small devices, up to 1012 in some of the largest ones. This neutron yield follows a power law with current I that goes as I4 [16], and with the stored energy W0 that goes as W02 [2]. Further studies on the scaling laws of DPF machines have been carried out by Lee and Serban [17].

Throughout the past forty years, the operation of plasma foci has been documented for stored energies that range from 2 kJ [6, 10, 18, 19] up to 1 MJ [2, 20]. The behaviour of small devices around 2kJ has been thoroughly studied. The influence of electrode and insulator materials on the neutron emission, has been studied by Rout et al. [18], and comparative studies of ion, x-ray and neutron emission have been carried out [19]. Small portable machines have been proposed for introspective imaging of metallic objects and for neutronic detection of water [8, 9]. Furthermore, smaller devices with high repetition rate have been developed for applications such as microelectronics lithography [6] and biomedical studies [7]. It can be stated that plasma focus research has spread because of its interesting physics phentomena, its potential applications, the simplicity of its engineering, and its affordability.

The present work stems from the Fuego Nuevo II Dense Plasma Focus Device with two different oxygen-free copper electrodes. The outer electrode is arrayed as a squirrel cage. One of the objectives of this work is to compare the performance of two different inner electrodes with equal length but different diameter. The first electrode, hereafter called electrode I, is a solid cylinder fully contained within the insulator, so its diameter is smaller than the inner diameter of the insulator. The diameter of the second one, hereafter called electrode II, by contrast, matches the outer diameter of the insulator. It may be surmised that the second one may allow a better breakdown, not only because its path is decreased, but also because there is an edge effect at the electrode-insulator joint. It will be shown this is the case.

The structure of the paper is as follows: A brief description of the FN-II device and the diagnostics relevant to this work is made in section II. The latter include time integrated silver activation and nuclear track detectors, which were used to obtain anisotropy and angular distribution measurements, scintillator-photomultiplier systems, used for time resolved detection of hard X-rays and neutrons, and the multi-pin-hole camera. The results for time integrated neutron yield and anisotropy for each electrode will be presented and discussed in section III. Time resolved hard X-rays and neutron signals will be presented in section IV, showing that a slight Doppler effect for the neutron energy can be detected at backward angles. Time integrated pin-hole x-ray signals, and radiographs obtained on axis will be shown in section V. Finally, some conclusions will be drawn in section VI.

II Description of the experimental device

A scheme of the experimental arrangement is shown in Fig. 1. Two different inner electrodes (anodes) of equal length (40 mm long), but differing diameter have been tested. The insulator used in both cases is a 10 mm long Pyrex sleeve, with an outer diameter of 50 mm. The diameter of electrode I is 40 mm, while that of electrode II matches the outer diameter of the Pyrex sleeve. The squirrel cage outer electrode (cathode) consists of 12 copper bars, of 8 mm diameter and 36 mm long each, arrayed on a 100 mm diameter circle. The capacitor bank consists of four 1.863 mF capacitors in parallel, with an internal inductance of 24 nH each. The energy is conducted through a parallel copper plate transmission line insulated by six Mylar sheets, with a total thickness of 2.2 mm. The inductance of the system has been measured by short-circuiting the gun, and found to be 54 nH. The circuit is closed by a spark gap switch, pressurised with air, and triggered by a micro Marx generator, which produces a 100 kV pulse with a 20 ns rise time. The results obtained in this work were produced by charging the capacitor bank at 36 kV, which means the stored energy was 4.6 kJ.


The behaviour of the circuit is monitored with a Rogowski coil which yields the derivative of the current signal dI/dt. Fig. 2 shows a typical oscillogram, where (a) is the dI/dt signal, and (b) is the signal from a scintillator-photomultiplier detector, described below. The dip near dI/dt = 0, corresponds to a sudden drop of current, which occurs as impedance rises during the compression of the plasma column. This is the signature of the focusing of the plasma column.


Time integrated measurements of the neutron yield and its anisotropy are made with two different methods. Silver activation detectors are used on a shot to shot basis. These consist in two Victoreen 1B85 Geiger-Muller counters, with lateral window, 10 cm long, wrapped up in a 500 mm silver foil, and surrounded by 6 cm of paraffin. The total size of each detector is 22 cm high with a 15.5 cm diameter. Their purpose is to measure the b decay of 108Ag and 110Ag nuclei that result from the activation of 107Ag and 109Ag, respectively. The paraffin moderates the neutrons, therefore increasing the activation cross section. Both counters were placed 54 cm away from the focus, one of them on the axis of the device, and the other one at 90o. They were calibrated with an Am-Be neutron source, and the background counts were monitored on a daily basis, in order to check the invariance of their behaviour. According to the calibration, the behaviour of both counters was very similar, and could be considered to be the same within two significant figures. The neutron yield per steradian, measured by each counter, is the number of counts collected in 60 sec multiplied by (9.4 ± 0.3) × 103. The minimum neutron yield threshold per steradian per minute that can be measured, determined by the background, is (4.7 ± .9) × 104 . Further information on this method can be found in Ref.[21].

The second method used to measure the neutron anisotropy, and specifically the average neutron angular distribution, consisted in using CR-39 plastic nuclear track detectors. Fast neutrons can be detected with the CR-39 polycarbonate (C12H18O7), either by elastic scattering with protons from the detector material or radiator foils, such as polyethylene placed in front [22], or by a particles produced by 10B(n,a) reactions [23]. At higher energies, even scattered C and O atoms generate etchable tracks [22]. These tracks can be chemically etched by agents such as NaOH or KOH. This method has been used earlier at other devices to detect neutrons of energy around 2.45 MeV [24]. However it was not used to evaluate the role of the angular distribution in the determination of the total neutron yield, which is one of the purposes of this work. Rectangular chips, with a 1.9 cm × 0.9 cm surface and 500 mm thickness were placed on a circular arc of 100 cm radius, centred at the focus, outside the discharge chamber. Five different angles relative to the gun axis were chosen: 0o, 45o, ± 90o, 135o and 170o. It was found that, in order to detect neutrons, the CR-39 needed to be covered with polyethylene sheets, 2 mm thick. The detectors were exposed to 65 shots, for a filling pressure of 2.75 torr. This particular choice of pressure will be explained below. The chemical etching of the plastic chips was performed by immersing them in KOH, 6.25M solution, at (60 ± 1)oC for 6 hours. The track counting was done with an optical microscope, with a 200 × magnification, fixing a field of 0.36 mm ×0.3 mm as measurement area. Forty fields per chip were counted, in each chip, in order to obtain better statistics. The optical microscope is coupled to a CCD camera and a Digital Image Analysis System (DIAS) [25], making all the measurements process automatically.

Two scintillator-photomultiplier detectors have been used for time resolved neutron detection. The scintillators, NE211 and NE218, are both contained within cylinders of equal size; 7 cm long and 5 cm diameter. They are coupled to AMPEREX photomultiplier tubes model 56 AVP. In order to minimise the hard X-ray signal, the scintillators are surrounded by a 1 cm lead shield, and their front is covered by lead and copper filters. Signal (b) in Fig. 2 was obtained with the NE211 scintillator and a Pb filter 5.53 mm thick, followed by a 2.65 mm Cu foil. The peak that almost coincides with the dip of the Rogowski coil signal is produced by hard X-rays, and it is clearly resolved from the neutron pulse by time of flight. Thus, if the energy of the neutrons varies with the angle, this can be determined as a Doppler shift, measuring the difference in the time of flight between the X-ray and the neutron peaks at different angles. Further details will be given in section V.

Although the inner electrode is a solid cylinder, the centre of the tip is hollow, so that hard X-rays from the collision of the electron beam with it are hidden from direct observation at 90o from the axis. A multi-pin-hole camera was placed in that direction, for time integrated X-ray imaging of the plasma column. Five circular pinholes, 400 mm in diameter, and separated by 4.5 mm were made on a 2 mm thick Cu screen, 19 cm away from the axis. Each hole was covered by 25, 10, 5, 15 and 20 mm thick Al filters respectively. Although the 400 mm diameter of the pinholes may be too large for getting a proper resolution, it was chosen in order to guarantee reproducibility of the five holes. The images were recorded on X-ray dental film, placed within an evacuated camera 7.6cm away from the copper screen, on a revolver-like film back with capacity for four films. This yields a .40 magnification of the observed object. The time (3 min.) and temperature (20oC) of the developing process were controlled, so the intensities obtained for different shots could be compared.

Besides the pin-hole camera, a 300 mm Al window was placed on axis, 35 cm away from the inner electrode, which allows observation of the hard X-rays produced on the face of the inner electrode.

III Neutron yield and anisotropy results

Two silver activation detectors, as described above, were used to measure the neutron yield and anisotropy for electrodes I and II. The number of counts obtained during sixty seconds after each shot, were recorded for one detector placed on axis (0o) and the other at 90o. A wide range of filling pressures was explored, going from 1.0 to 4.5 torr. The average number of counts N0 for the detector on axis, and N90 for the detector at 90o, as a function of filling pressure are shown in Fig. 3(a) for electrode I and Fig. 3(b) for electrode II. The case of electrode I includes 400 shots, while that of electrode II includes 539 shots. It must be noted that for electrode I the number of counts is barely above the background for pressures below 1.5 torr, while electrode II showed a larger neutron yield at low pressures. It is also observed that the error bars, which show the mean square deviation, are smaller for electrode II. This reflects a better reproducibility for this geometry. Generally speaking, the neutron yield is clearly larger for electrode II than for electrode I, the maximum being roughly 3 times as large for the first one. This maximum appears around 3.50 torr for electrode I, and is shifted down to 2.75 torr for electrode II. The corresponding scale for dYN/dW is given on the right of Figs. 3(a) and (b).


The data for both electrodes show a clearly defined anisotropy A = N0/N90, which is shown as a function of the deuterium filling pressure in Fig. 4. Electrode II shows a stronger A, which tends to be larger for lower pressures, up to 2.75 torr, and falls thereafter. The anisotropy for electrode I generally falls below that of electrode II, and remains roughly constant, within the error bars, throughout the range of pressures explored. A better reproducibility is found for electrode II again. It may also be interesting to look at the scattergrams of A for several shots vs. the number of counts of the detectors. As a best case sample, Fig. 5 shows A vs. N0 for electrode II. A linear regression shows a clear tendency of anisotropy to grow with the number of counts. This result shows the relevance of the beam-target effect as a neutron generation mechanism. It may be surmised that the better the ion beam generation, the larger the neutron yield will be for a given stored energy.



Once the optimum pressure 2.75 torr was found for electrode II, the average angular distribution of the neutron yield was determined using the CR-39 detectors. The angular distribution of the track density, obtained with 65 shots is shown in Fig. 6, normalised to the average value at 0o. The data obtained for positive angles can be adjusted by a Gaussian function superposed on a pedestal;

where q is the angle in degrees, B= .507, C= 82.7 and s = 70.6. The values obtained for the samples at ± 90o confirm the symmetry of the distribution, as can be seen from the figure. Eq.(1) can be used in order to estimate by integration the total neutron yield, introducing a proper scaling factor for B and C, using the silver activation counters data. The isotropic pedestal contributes 70% of the neutron yield, while the anisotropic Gaussian distribution accounts for the remainig 30%. For the case of the 65 shots, for which Fig. 6 was obtained, the average number of counts on axis and at 90o are < N0 > = 2034 and < N90 > = 1265, which yield dY0/dW = 1.9 × 107 and dY90/dW = 1.2 × 107 neutrons/str, respectively. From these values, and the ones obtained from the adjusted curve, eq.(1), for both positions, an optimistic scaling factor S1= 2.0 × 107 is obtained at 0o, and a pesimistic one S2= 1.7 × 107 at 90o. They agree within 18%. Integrating eq.(1) over the sphere, and taking the average between the values obtained for S1 and S2, the total neutron yield per shot, for this particular set of 65 shots is found to be YN = (1.66 ± 0.14) × 108. This value is 11% higher than the one expected from the measurements at 90o, which would be 1.5 × 108, assuming the emission were isotropic.


The value of A obtained from the CR-39 data is 1.37 ± .05. For this particular set of shots, the anisotropy measured with the silver activation detectors, obtained on a shot to shot basis, is 1.55 ± 0.22, which is consistent within the experimental error. Besides counting the track density by means of DIAS, their diameters were also measured. All five chips were considered for this measurement. More than 90% of the tracks fall within a strongly peaked Gaussian distribution centred around 19.8 mm, with a full width at half maximum of 4.3 mm. These are presumably produced by protons kicked off the polyethylene plate by elastic (n,p) scattering. This is an indication that the neutrons that are being detected are strongly mono-energetic. The remaining 10% of the tracks are attributable to a neutron background, which results from reflections on the floor and walls.

IV Time integrated X-ray results

Time integrated soft X-ray images of the plasma column have been obtained with a multi-pin-hole camera, as that described in section II. Typical images obtained with electrode I are shown in Figs. 7a and b. In the first case m= 0 and bright-spots can be observed. The length of the central image is 8 mm, which means the maximum size of the plasma column is around 20 mm. This case corresponds to shot 2578, where N0 = 283 and N90 = 164. An interesting example is that of shot 2582, shown in Fig. 7b, where the column is kinked, and a hot-spot appears in the kinked column. It looks like an m= 0 instability occurs well after the plasma column has been bent as a result of an m= 1 instability. Obviously, this statement cannot be conclusive without the support of time resolved diagnostics. In this case N0 = 523, while N90 = 372. However, these two cases differ significantly from the images obtained with electrode II, which are generally dimmer. A good example is that of Fig. 8a, corresponding to shot 2745, where the neutron yield is considerably larger: N0 = 8876 and N90 = 3347. This hints at the possibility that the radiation from electrode I has a stronger line radiation component originated by impurities, than that of electrode II. Since the neutron yield is clearly greater for the latter, it is apparent that the impurity radiation cooling acts in detriment of neutron production.



Harder X-rays cross the 300 mm Al window on the axis which can be used for radiographical purposes, such as the those shown in Fig. 8, where the inner details of a pencil can be observed. There is an inverse relationship between the intensities of such on-axis X-rays and the soft X-rays at the pin-hole camera. This can be seen as follows: An array of superposed Pb foils, each 63 mm thick was prepared, such that the maximum thickness corresponds to five foils 315 mm. For shot 2745, shown in Fig. 8a, the radiograph of the Pb filter obtained on axis is shown in Fig. 8b. In contrast, for shot 2744, where the neutron yield is lower (N0 = 1329, N90 = 706), the soft X-rays at the pinhole camera are stronger, as shown in Fig. 10a, while the radiograph on axis, Fig. 10b, is considerably dimmer than for the former case. This pattern is systematically observed. It may surmised that, since the hard X-rays observed on axis are produced by the electron beam that collides on the inner electrode, the stronger the beam, the greater is the neutron yield. Thus, the electron acceleration mechanism may be correlated with the neutron generation mechanism. Further time resolved studies may clarify this possibility. On the other hand, the pinhole cameras indicate that purer, impurity-free plasmas allow a better neutron yield. This is consistent with the discussion in the previous paragraph.



V Time resolved hard X-ray and neutron measurements

Two scintillator-photomultiplier systems have been used for hard X-ray and neutron measurements, as described in section II. The geometry is similar for both, but in one case the scintillator used is NE-211, while in the other one it is NE-218. Signal (b) in Fig. 2 was obtained with the NE-211 at 5.4 m from the axis of the device. The first peak that almost coincides with the dip of the dI/dt signal is a hard X-ray pulse, related to the electron acceleration in the focus phase, while the neutron pulse is observed in the second peak, retarded by their time of flight. For this particular shot, 2909, N0 = 8545 and N90 = 3284. The two scintillators used in this work have similar response to the neutron signal within 20 ns. In the case of the x-ray signal the difference is indistinguishable.

The NE-211 was found to be more effective. This can be seen in Fig. 11, where both detectors were placed at the same distance of 5.4 m, with 6.4 mm Pb and 1.3 mm Cu filters. For this shot, 3461, N0= 1039, and N90= 735. In the oscilogram shown in Fig. 11, both detectors were placed at 5.4 m from the focus, but at different angles. The NE218 detector (signal (b)) was placed at 90o from the axis, while the NE211 detector (signal (a)) was placed at a 170o backwards angle. The former was filtered with 6.4 mm Pb and 1.3 mm Cu, and the latter with a set of 5.35 mm Pb and 2.65 mm Cu. The hard X-ray peak can be used as a time reference for the occurrence of the focus, and the energy of the neutrons can be measured in terms of the difference of the time elapsed between both peaks, the main problem being that neutrons emitted at a later time can overlap neutrons emitted earlier with smaller energy. Thus, for 5.4 m, the equivalence between the time difference and the energy of neutrons is given by D(t)(sec)= .397 ×10-6E(MeV)-1/2. From the difference of occurrence of the maxima of both detectors, a Doppler shift in the energy is clearly observed, despite of the experimental error. The results are shown in Table 1.


VI Conclusions

Two electrode configurations have been tested: one where the electrode is fully contained within the insulator (electrode I), and one where the electrode diameter matches the one of the insulator (electrode II). The neutron yield and anisotropy was found to be substantially larger for the latter case, while an improvement in reproducibility was also observed. This may be related to a better current sheath formation at the breakdown phase, as a result of both the edge effect of the electrode, close to the insulator, and a decrease in the breakdown length.

This work provides evidence that neutron yield tends to increase with anisotropy in this device, which points to the convinience of the beam-target effect for neutron generation. From the average angular distribution of the neutron emission, measured with CR-39 nuclear track detectors, it is found that there is an isotropic pedestal that accounts for 70% of the emission, while the anisotropy component accounts for the remaining 30%. The estimation of the total neutron yield using this information is 11% larger than what would be expected form the silver activation detector measurement at 90o, assuming the emssion were isotropic. Further evidence of the existence of the beam-target effect is demonstrated by a Doppler effect observed at backward angles with scintillator-photomultiplier systems.

The pinhole camera images tend to be dimmer for high neutron yield shots, which may be related to a smaller line radiation from impurities, and consequently lower radiation cooling. These images are generally dimmer for electrode II than for electrode I. On the other hand, the fact that a dimmer emission of soft X-rays at 90o, together with a brighter emission of X-rays on axis are observed when the neutron yield is larger, seems to indicate that the neutron generation is related to the formation of the electron beam that impinges on the electrode. It may be interesting to note that after 560 shots, the electron beam drilled an almost cylindrical hole, 3mm wide and 6 mm deep, in electrode I, while the erosion in electrode II, after 956 shots showed as a cone, 6 mm wide and 12mm deep. Both in the cases of soft x-ray emissions at 90o, and hard x-ray emissions on the axis, spectroscopy will be made in future work, in order to clarify the nature of the phenomena.

Regarding the pin-hole x-ray images, it is interesting to point out that, in some cases, bright spots that are related to m= 0 instabilities are observed in kinked columns which presumably arise from m= 1 instabilities. This might mean that under certain circumstances the m= 1 instability may have a faster growth rate than m= 0 instabilities, against common wisdom. However, study of this phenomena with time resolved optical diagnostics are needed in order to clarify this.

Acknowledgments

The authors wish to acknowledge the fruitful interaction with Jorge Pouzo. F. Castillo is particularly grateful for his hospitality at the Universidad del Centro de la Provincia de Buenos Aires. This work was partially supported by DGAPA-UNAM project IN105100, and the International Atomic Energy Agency, that made possible the attedance of J.J.E. Herrera to this meeting.

  • [1] J.M. Mather, "Dense Plasma Focus", in Methods in Experimental Physics, Vol.9 , Part B, ed. R.H.Lovberg and H.R.Griem (Academic Press, Nueva York, 1971) pp.187-249.
  • [2] J.S. Brzosko, J.H. Degnan, N.V. Filippov, B.L. Freeman, G.F. Kiutlu and J.W. Mather, "Comments on the Feasibility of Achieving Scientific Break-even with a Plasma Focus Machine", in Current Trends in International Fusion Research, ed. E.Panarella (Plenum Press, New York, 1997) pp. 11-32.
  • [3] A. Bernard, H. Bruzzone, P. Choi, H. Chuaqui, V. Gribkov, J. Herrera, K. Hirano, A. Krejci, S. Lee, C. Luo, F. Mezzetti, M. Sadowski, H. Schmidt, K. Ware, C.S. Wong and V. Zoita, J. Moscow Phys. Soc. 8 93 (1998).
  • [4] J. Pouzo, "Project of a Major DPF Facility Based on Original Criteria of Design Optimizing the Neutron Yield Performace" in Proc. Intl. Symp. Plasma '97: Research and Applications of Plasmas Vol.1, ed. Sadowski M and Rothkaehl H (Space Research Center PAS, Poland, 1997) pp.65-71.
  • [5] R. Lebert, A. Engel, K. Bergmann, O. Treichel, C. Gavrilescu and W. Neff, "Compact Plasma Focus Devices: Flexible Laboratory Sources for Applications" in Dense Z-Pinches, Fourth International Conference ed. N. Pereira, J. Davis and P.E. Pulsifer (AIP Conference Proceedings 409, Woodbury, New York, 1997) pp.291- 298.
  • [6] S. Lee, P. Lee, G.Zhang, X. Feng , V.A. Gribkov, M. Liu, A. Serban and T.K. Wong IEEE Trans. Plasma Science 26, 1119 (1998).
  • [7] A.V. Dubrovsky, V.A. Gribkov, T.A. Kozlova, L.V. Volobuev, and M.A. Orlova J. Tech. Phys. 39, Special Suppl. 133 (1998).
  • [8] C. Moreno, A. Clausse, H. Bruzzone, J. Martínez, R. Llovera, and A. Tartaglione, "Small-Chamber 4.7 kJ Plasma Focus for Applications" in Proc. IX Latin American Workshop on Plasma Physics ed. H. Chuaqui and M. Favre, (AIP Conference Proceedings 563], Woodbury, New York,2001) pp. 276-281.
  • [9] C. Moreno, A. Clausse, J. Martínez, R. Llovera, A. Tartaglione, M. Vénere, R. Barbuzza and M. del Fresno, "Using a 4.7 kJ Plasma Focus for Introspective Imaging of Metallic Objects and for Neutronic Detection of Water" in Proc. IX Latin American Workshop on Plasma Physics ed. H. Chuaqui and M. Favre (AIP Conference Proceedings 563), Woodbury, New York, 2001) pp. 300-305.
  • [10] F.N. Beg, I. Ross and A.E. Dangor, "X-ray Emission from a 2kJ Plasma Focus" in Dense Z-Pinches, Fourth International Conference, Vancouver, 1997, ed. N. Pereira, J. Davis and P.E. Pulsifer (AIP Conference Proceedings 409, Woodbury, New York, 1997) pp. 339-343.
  • [11] L. Jakubowski, M. Sadowski and E. Baronova, "Experimental Studies of Hot-Spots Inside PF Discharges with Argon Admixtures" in Proc. 1996 Int. Conf. on Plasma Physics, Nagoya, 1996, ed. H. Sugai and T. Hayashi (Arakawa Printing Co., Japan, 1997) pp. 1326-1329.
  • [12] M.G. Haines, Nucl. Instrum. Methods 207, 179 (1983).
  • [13] V.V. Vikhrev, Sov.J.Plasma Phys. 12, 262 (1986).
  • [14] B.A. Trubnikov, Sov.J.Plasma Phys. 12, 271 (1986).
  • [15] R. Deutsch and V. Kies, Plasma Phys. and Controlled Fusion 30, 263 (1988).
  • [16] M. Milanese and J. Pouzo, "Neutron Yield Scaling Laws for Plasma Focus Devices", in Small Plasma Physics Experiments, ed. Lee S and Sakanaka P H (World Scientific, Singapore, 1988) pp.66-79.
  • [17] S. Lee and A. Serban, IEEE Trans. Plasma Science 24, 1101 (1996).
  • [18] R.K. Rout, A.B. Garg, A. Shyam, and M. Srinivasan, IEEE Trans. Plasma Science 23, 996 (1995).
  • [19] M. Zakaullah, I. Akhtar, A. Waheed, K. Alamgir, A.Z. Shah, and G. Murtaza, Plasma Source Sci. Technol. 7, 206 (1998).
  • [20] M. Scholz, M. Borowiecki, L. Karpinski, R. Miklaszewski, W. Stepniewski, M. Sadowski, A. Szydlowski, V.M. Romanova, S.A. Pikuz, and T.Ya. Faenov, "X-Ray Emission from a Megajoule Plasma-Focus Experiment" in it Proc. Intl. Symp. Plasma '97: Research and Applications of Plasmas Vol.2, ed. Sadowski M and Rothkaehl H (Space Research Center PAS, Poland, 1997) pp.125-128.
  • [21] A. Gentilini, J.P. Rager, M. Tacchi, D. Antonini, B. Arcipiani, E. Moioli, E. Pedretti, and R. Scafe, Nucl. Instrum. Methods 172, 541 (1980).
  • [22] H.J. Brede, A. Gisbertz, I. Kohler, E. Pitt, and A. Scharmann, Radiat. Prot. Dosim. 85, 113 (1999).
  • [23] R. Ilic, E.S. Kristof, R. Dijanosic, J. Skvarc. and R. Dobnikar, Radiat. Meas. 25, 453 (1995).
  • [24] F. Castillo, M. Milanese, R. Moroso, and J. Pouzo, J. Phys. D: Appl. Phys. 30, 1499 (1997).