Acessibilidade / Reportar erro

Determination of nimodipine in plasma by HPLC-MS/MS and pharmacokinetic application

To develop and validate a rapid, specific and highly sensitive method to quantify nimodipine in human plasma using dibucaine as the internal standard (IS). The analyte and IS were extracted from plasma samples by liquid-liquid extraction using hexane-ethyl acetate (1:1 v/v). The chromatographic separation was performed on a Varian® Polaris C18 analytical column (3 μm, 50 x 2.0 mm) and pre-column SecurityguardTM C18 (4.0 x 3.0 mm) with a mobile phase of Acetonitrile-Ammonium acetate 0.02 ml/L (80:20v/v). The method had a chromatographic run time of 4.5 min and linear calibration curve over the range of 0.1- 40 ng/mL (r > 0.9938). The limit of quantification was 100 pg/mL. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. This validated method was successfully applied in determining the pharmacokinetic profile of nimodipine tablets of 30 mg administered to 24 healthy volunteers. The proposed method of analysis provided a sensitive and specific assay for nimodipine determination in human plasma. The time for the determination of one plasma sample was 4.5 min. This method is suitable for the analysis of nimodipine in human plasma samples collected for pharmacokinetic, bioavailability or bioequivalence studies in humans.

Nimodipine; Nimodipine; Nimodipine; Pharmacokinetics


Universidade de São Paulo, Faculdade de Ciências Farmacêuticas Av. Prof. Lineu Prestes, n. 580, 05508-000 S. Paulo/SP Brasil, Tel.: (55 11) 3091-3824 - São Paulo - SP - Brazil
E-mail: bjps@usp.br