Acessibilidade / Reportar erro

Uniformity microsprinkler irrigation system using statistical quality control

Uniformidade da irrigação por microaspersão utilizando o controle estatístico de qualidade

ABSTRACT:

The objective of this study was to evaluate the use of statistical quality control tools in the analysis of the uniformity of a microsprinkler irrigation system. For the analysis of irrigation Christiansen uniformity coefficient (CUC) and the distribution uniformity coefficient (DU) were statistically analyzed by means of the Shewhart control charts and process capability index (Cp). For the experiment 25 tests were carried out with a single micro sprinkler and subsequently seven different spacing between micro sprinklers were simulated. Control charts contributed to the diagnosis of the treatments to be under control and with satisfactory uniformity outcomes. Increase in process capability index was directly proportional to the average of CUC and DU.

Key words:
Christiansen uniformity coefficient; distribution uniformity coefficient; control charts; process capability index

Universidade Federal de Santa Maria Universidade Federal de Santa Maria, Centro de Ciências Rurais , 97105-900 Santa Maria RS Brazil , Tel.: +55 55 3220-8698 , Fax: +55 55 3220-8695 - Santa Maria - RS - Brazil
E-mail: cienciarural@mail.ufsm.br