Acessibilidade / Reportar erro

Influence of a sandy soil compaction in leachate infiltration and organic loading retention

Water and leachate flow and COD attenuation through a fine sandy soil at different compaction degree were assessed, based on column tests results. Each column was 1.0 m deep and 0.097 m in diameter, and the soil was compacted with 75 (natural), 80, 85, 90 and 95% of Standard Proctor Test, to receive water or sanitary landfill leachate under unsaturated conditions. During the experiment, COD removal and leachate permeability reduction were very significant for columns with 85% or higher compaction levels. The results show the high potential of this practice to install simple system in small sanitary landfills, for leachate organic loading retention.

Leachate flow; sandy soils; organic loading attenuation


Associação Brasileira de Engenharia Sanitária e Ambiental - ABES Av. Beira Mar, 216 - 13º Andar - Castelo, 20021-060 Rio de Janeiro - RJ - Brasil - Rio de Janeiro - RJ - Brazil
E-mail: esa@abes-dn.org.br