Abstract

The aim of this study is to improve energy performance at a battery factory in Colombia by introducing the energy management approach defined in ISO 50001. In the study, the main energy consumptions were identified in the battery formation, the compressed air system and the large electric motors. An energy review was performed in the factory using measurement equipment and statistical techniques. Different actions were proposed to improve energy performance. As a result, a 3.48% reduction in electricity consumption was achieved during the implementation of the proposed measures.

Keywords:
Energy planning; Energy efficiency; ISO 50001

Resumen

El objetivo de este estudio es mejorar el rendimiento energético en una fábrica de baterías en Colombia mediante la introducción del enfoque de gestión energética definido en ISO 50001. En el estudio, los principales consumos de energía se identificaron en la formación de la batería, el sistema de aire comprimido y la gran red eléctrica motores. Se realizó una revisión energética en la fábrica utilizando equipos de medición y técnicas estadísticas. Se propusieron diferentes acciones para mejorar el rendimiento energético. Como resultado, se logró una reducción del 3,48% en el consumo de electricidad durante la implementación de las medidas propuestas.

Palabras clave:
Planificación energética; Eficiencia energética; ISO 50001

1 Introduction

Since the late 20th century, energy issues have been a top priority at all levels of discussion. This is because energy consumption is growing faster than the population, and the use of primarily fossil fuels is an evident cause of climate change, which poses a major threat to sustainability (Kaygusuz, 2012Kaygusuz, K. (2012). Energy for sustainable development: a case of developing countries. Renewable & Sustainable Energy Reviews, 16(2), 1116-1126. http://dx.doi.org/10.1016/j.rser.2011.11.013.
http://dx.doi.org/10.1016/j.rser.2011.11...
; Camioto et al., 2015Camioto, F. C., Rebelatto, D. A. N., & Rocha, R. T. (2015). Análise da eficiência energética nos países do BRICS: um estudo envolvendo a Análise por Envoltória de Dados. Gestão & Produção, 23(1), 192-203. http://dx.doi.org/10.1590/0104-530X1567-13.
http://dx.doi.org/10.1590/0104-530X1567-...
; Castro et al., 2015Castro, F., Aparecida, D., & Teixeira, R. (2015). Análise da eficiência energética nos países do BRICS: um estudo envolvendo a Análise por Envoltória de Dados. Gestão & Produção, 23(1), 192-203.).

Manufacturing is one of the activities that most consumes energy, accounting for 29% of total global consumption (Fawkes et al., 2016Fawkes, S., Oung, K., & Thorpe, D. (2016). Best practices and case studies for industrial energy efficiency improvement: an introduction for policy makers. Copenhagen: DTU. Retrieved in 2016, August 15, from http://www.unepdtu.org/-/media/Sites/energyefficiencycentre/Publications/C2E2 Publications/Best-Practises-for-Industrial-EE_web.ashx?la=da
http://www.unepdtu.org/-/media/Sites/ene...
). However, it is also one of the areas with the greatest potential in terms of savings, estimated at around 20% of consumption, equivalent to a reduction of 974 million tons of oil equivalent (mtoe) (Chan & Kantamaneni, 2015Chan, Y., & Kantamaneni, R. (2015). Study on energy efficiency and energy saving potential in industry and on possible policy mechanisms. London: ICF Consulting. Retrieved in 2016, August 15, from https://ec.europa.eu/energy/sites/ener/files/documents/151201 DG ENER Industrial EE study - final report_clean_stc.pdf
https://ec.europa.eu/energy/sites/ener/f...
; Fawkes et al., 2016Fawkes, S., Oung, K., & Thorpe, D. (2016). Best practices and case studies for industrial energy efficiency improvement: an introduction for policy makers. Copenhagen: DTU. Retrieved in 2016, August 15, from http://www.unepdtu.org/-/media/Sites/energyefficiencycentre/Publications/C2E2 Publications/Best-Practises-for-Industrial-EE_web.ashx?la=da
http://www.unepdtu.org/-/media/Sites/ene...
). One of the main paths to realizing such potential is through energy efficiencies (EE) achieved through improvements in energy management (EM) (Abdelaziz et al., 2011Abdelaziz, E. A., Saidur, R., & Mekhilef, S. (2011). A review on energy saving strategies in industrial sector. Renewable & Sustainable Energy Reviews, 15(1), 150-168. http://dx.doi.org/10.1016/j.rser.2010.09.003.
http://dx.doi.org/10.1016/j.rser.2010.09...
).

EM is defined by Abdelaziz et al. (2011Abdelaziz, E. A., Saidur, R., & Mekhilef, S. (2011). A review on energy saving strategies in industrial sector. Renewable & Sustainable Energy Reviews, 15(1), 150-168. http://dx.doi.org/10.1016/j.rser.2010.09.003.
http://dx.doi.org/10.1016/j.rser.2010.09...
) and Cabello Eras et al. (2016Cabello Eras, J. J., Sousa Santos, V., Sagastume Gutiérrez, A., Guerra Plasencia, M. Á., Haeseldonckx, D., & Vandecasteele, C. (2016). Tools to improve forecasting and control of the electricity consumption in hotels. Journal of Cleaner Production, 137, 803-812. http://dx.doi.org/10.1016/j.jclepro.2016.07.192.
http://dx.doi.org/10.1016/j.jclepro.2016...
) as a set of activities carried out to minimize the costs and environmental impacts of energy use without affecting production levels and quality, which involves the continuous improvement of energy performance through control, monitoring, planning and development of actions and strategies to increase EE (Bunse et al., 2011Bunse, K., Vodicka, M., Schönsleben, P., Brülhart, M., & Ernst, F. O. (2011). Integrating energy efficiency performance in production management: gap analysis between industrial needs and scientific literature. Journal of Cleaner Production, 19(6-7), 667-679. http://dx.doi.org/10.1016/j.jclepro.2010.11.011.
http://dx.doi.org/10.1016/j.jclepro.2010...
; Aragon et al., 2013Aragon, C. S., Pamplona, E., & Vidal Medina, J. R. (2013). Identification of energy efficiency investments and their risk assessment. Gestão & Produção, 20(3), 525-536.).

Even though many countries have made substantial progress in implementing EM (Cabello Eras et al., 2015Cabello Eras, J. J., Sagastume Gutiérrez, A., García Lorenzo, D., Cogollos Martínez, J. B., Hens, L., & Vandecasteele, C. (2015). Bridging universities and industry through cleaner production activities: experiences from the Cleaner Production Center at the University of Cienfuegos, Cuba. Journal of Cleaner Production, 108, 873-882. http://dx.doi.org/10.1016/j.jclepro.2014.11.063.
http://dx.doi.org/10.1016/j.jclepro.2014...
; Christoffersen et al., 2006Christoffersen, L. B., Larsen, A., & Togeby, M. (2006). Empirical analysis of energy management in Danish industry. Journal of Cleaner Production, 14(5), 516-526. http://dx.doi.org/10.1016/j.jclepro.2005.03.017.
http://dx.doi.org/10.1016/j.jclepro.2005...
; Gielen & Taylor, 2009Gielen, D., & Taylor, P. (2009). Indicators for industrial energy efficiency in India. Energy, 34(8), 962-969. http://dx.doi.org/10.1016/j.energy.2008.11.008.
http://dx.doi.org/10.1016/j.energy.2008....
; Hens et al., 2017Hens, L., Cabello-Eras, J. J., Sagastume-Gutiérez, A., Garcia-Lorenzo, D., Cogollos-Martinez, J. B., & Vandecasteele, C. (2017). University-industry interaction on cleaner production: the case of the Cleaner Production Center at the University of Cienfuegos in Cuba, a country in transition. Journal of Cleaner Production, 142, 63-68. http://dx.doi.org/10.1016/j.jclepro.2015.10.105.
http://dx.doi.org/10.1016/j.jclepro.2015...
; Palamutcu, 2010Palamutcu, S. (2010). Electric energy consumption in the cotton textile processing stages. Energy, 35(7), 2945-2952. http://dx.doi.org/10.1016/j.energy.2010.03.029.
http://dx.doi.org/10.1016/j.energy.2010....
; Posch et al., 2015Posch, A., Brudermann, T., Braschel, N., & Gabriel, M. (2015). Strategic energy management in energy-intensive enterprises: a quantitative analysis of relevant factors in the Austrian paper and pulp industry. Journal of Cleaner Production, 90, 291-299. http://dx.doi.org/10.1016/j.jclepro.2014.11.044.
http://dx.doi.org/10.1016/j.jclepro.2014...
; Rudberg et al., 2013Rudberg, M., Waldemarsson, M., & Lidestam, H. (2013). Strategic perspectives on energy management: a case study in the process industry. Applied Energy, 104, 487-496. http://dx.doi.org/10.1016/j.apenergy.2012.11.027.
http://dx.doi.org/10.1016/j.apenergy.201...
; Vine, 2005Vine, E. (2005). An international survey of the energy service company ESCO industry. Energy Policy, 33(5), 691-704. http://dx.doi.org/10.1016/j.enpol.2003.09.014.
http://dx.doi.org/10.1016/j.enpol.2003.0...
; Weinert et al., 2011Weinert, N., Chiotellis, S., & Seliger, G. (2011). Methodology for planning and operating energy-efficient production systems. CIRP Annals Manufacturing Technology, 60(1), 41-44. http://dx.doi.org/10.1016/j.cirp.2011.03.015.
http://dx.doi.org/10.1016/j.cirp.2011.03...
), it is widely acknowledged that there is still a long way to go in terms of optimizing the potential of EM and EE for reducing energy consumption and the environmental impact of manufacturing (Bunse et al., 2011Bunse, K., Vodicka, M., Schönsleben, P., Brülhart, M., & Ernst, F. O. (2011). Integrating energy efficiency performance in production management: gap analysis between industrial needs and scientific literature. Journal of Cleaner Production, 19(6-7), 667-679. http://dx.doi.org/10.1016/j.jclepro.2010.11.011.
http://dx.doi.org/10.1016/j.jclepro.2010...
; Cagno & Trianni, 2014Cagno, E., & Trianni, A. (2014). Evaluating the barriers to specific industrial energy efficiency measures: an exploratory study in small and medium-sized enterprises. Journal of Cleaner Production, 82, 70-83. http://dx.doi.org/10.1016/j.jclepro.2014.06.057.
http://dx.doi.org/10.1016/j.jclepro.2014...
; EC, 2014European Commission – EC. (2014). Communication from the commission to the European parliament and the council energy efficiency and its contribution to energy security and the 2030 Framework for climate and energy policy. Brussels. Retrieved in 2016, August 15, from https://ec.europa.eu/energy/sites/ener/files/ documents/2014_energy_efficiency_communication.pdf
https://ec.europa.eu/energy/sites/ener/f...
; Giacone & Mancò, 2012Giacone, E., & Mancò, S. (2012). Energy efficiency measurement in industrial processes. Energy, 38(1), 331-345. http://dx.doi.org/10.1016/j.energy.2011.11.054.
http://dx.doi.org/10.1016/j.energy.2011....
; ISO, 2014International Organization for Standardization – ISO. (2014). ISO 50004: energy management systems: Guidance for the implementation, maintenance and improvement of an energy management system. Geneva.; Ospino-Castro, 2010Ospino-Castro, A. (2010). Análisis del potencial energético solar en la Región Caribe para el diseño de un sistema fotovoltaico. INGECUC, 6(6), 1-8. Retrieved in 2016, August 15, from http://revistascientificas.cuc.edu.co/index.php/ingecuc/article/view/296
http://revistascientificas.cuc.edu.co/in...
; Weinert et al., 2011Weinert, N., Chiotellis, S., & Seliger, G. (2011). Methodology for planning and operating energy-efficient production systems. CIRP Annals Manufacturing Technology, 60(1), 41-44. http://dx.doi.org/10.1016/j.cirp.2011.03.015.
http://dx.doi.org/10.1016/j.cirp.2011.03...
).

Electric batteries are essential components in numerous applications. The most widely used type is the lead-acid battery, of which three types are produced: starter, traction and stationary batteries. These are used in motor vehicles, electric vehicles and energy storage applications, respectively.

The bulk of production is in starter batteries, of which close to 41.5 billion dollars were sold in 2012 (Miloloza, 2013Miloloza, I. (2013). Tendencies of development of global battery market with emphasis on Republic of Croatia. Interdisciplinary Description of Complex Systems, 11(3), 318-333. http://dx.doi.org/10.7906/indecs.11.3.3.
http://dx.doi.org/10.7906/indecs.11.3.3...
). Manufacturing of such batteries is highly energy-intensive, as the process uses large quantities of electricity and other energy carriers (Pavlov, 2011Pavlov, D. (2011). Lead-acid batteries: science and technology: a handbook of lead-acid battery technology and its Influence on the product. Amsterdam: Elsevier.; Report Buyer Ltd., 2015Report Buyer Ltd. (2015). Global and China lead-acid battery industry report, 2015-2018. London. Retrieved in 2016, August 15, from http://www.prnewswire.com/news-releases/global-and-china-lead-acid-battery-industry-report-2015-2018-300200529.html
http://www.prnewswire.com/news-releases/...
; Rydh, 1999Rydh, C. J. (1999). Environmental assessment of vanadium redox and lead-acid batteries for stationary energy storage. Journal of Power Sources, 80(1-2), 21-29. http://dx.doi.org/10.1016/S0378-7753(98)00249-3.
http://dx.doi.org/10.1016/S0378-7753(98)...
; Sullivan & Gaines, 2012Sullivan, J. L., & Gaines, L. (2012). Status of life cycle inventories for batteries. Energy Conversion and Management, 58, 134-148. http://dx.doi.org/10.1016/j.enconman.2012.01.001.
http://dx.doi.org/10.1016/j.enconman.201...
). According to (Rydh & Sandén, 2005Rydh, C. J., & Sandén, B. A. (2005). Energy analysis of batteries in photovoltaic systems. Part I: performance and energy requirements. Energy Conversion and Management, 46(11-12), 1957-1979. http://dx.doi.org/10.1016/j.enconman.2004.10.003.
http://dx.doi.org/10.1016/j.enconman.200...
), each kilo of battery production consumes between 15 and 34 MJ, depending on whether the raw materials are recycled or virgin. The production process accounts for 30% of such energy, primarily in machine operation, heat-based processes for the transformation of materials, battery assembly, and ancillary systems such as compressed air. The stage of the process that consumes most energy is battery formation (Jung et al., 2016Jung, J., Zhang, L., & Zhang, J. (2016). Lead-acid battery technologies. fundamentals, materials and applications. Florida: CRC Press.; Pavlov, 2011Pavlov, D. (2011). Lead-acid batteries: science and technology: a handbook of lead-acid battery technology and its Influence on the product. Amsterdam: Elsevier.; Sullivan & Gaines, 2012Sullivan, J. L., & Gaines, L. (2012). Status of life cycle inventories for batteries. Energy Conversion and Management, 58, 134-148. http://dx.doi.org/10.1016/j.enconman.2012.01.001.
http://dx.doi.org/10.1016/j.enconman.201...
), during which batches of batteries are charged simultaneously for the first time. This is a critical process, as the useful life and performance of the battery largely depends on the manner in which this process is performed.

Heat energy is used primarily in the lead melting process involved in manufacturing battery components. According to (Rantik, 1999Rantik, M. (1999). Life cycle assessment of five batteries for electric vehicles under different charging regimes (KFB-Meddelande, 28). Goteborg: KFB.), the most widely used energy carrier is electricity (4.8 MJ/kg of batteries), followed by heat (1.68 MJ/kg) and liquefied petroleum gas (LPG) (1.3 MJ/kg).

Despite the high energy-intensiveness of the lead-acid battery manufacturing process, only a handful of studies in the specialized literature address this topic.

The primary objective of this study is to improve energy performance through the implementation of the energy planning process described in the ISO 50001 standard at a Colombian battery factory (ISO, 2011International Organization for Standardization – ISO. (2011). ISO 50001: energy management systems: requirements with guidance for use. Geneva.).

The study also aims to lay the foundations for the implementation of an Energy Management System, which over the medium term will complement the Integrated Management System at the company, which holds certifications in ISO 9000 “Quality Management System”, ISO 14000 “Environmental Management System” and ISO 45001 “Work Health and Safety Management System”, contributing substantially to improving overall performance at the company (Cañizares et al., 2015Cañizares, G., Cuevas, M., Pérez, R. A., & González, E. (2015). Diseño e integración del sistema de gestión de la energía al sistema de gestión de la calidad en la ronera central” Agustín Rodríguez Mena. Sobre los Derivados de la Caña de Azúcar, 49(1), 46-52.).

2 Material and methods

2.1 Lead-acid battery manufacturing process

Figure 1 represents the lead-acid battery manufacturing process and its main energy inputs.

Figure 1
Lead-acid battery manufacturing process. LPG = Liquefied Petroleum Gas.

In the cell manufacturing process, the raw material is a lead alloy. The cells are manufactured by means of casting in book molds, or through continuous processes such as stamping, extrusion or continuous casting with subsequent rolling. In this process the most widely used energy carrier is heat, which is used to melt the lead, and is usually generated from LPG or oil, followed by electric power for the machines (Jung et al., 2016Jung, J., Zhang, L., & Zhang, J. (2016). Lead-acid battery technologies. fundamentals, materials and applications. Florida: CRC Press.).

Lead oxide is the main active component of the batteries’ positive and negative electrodes and it is used to coat the cells. They are produced using high purity lead, which is molten in a container and stirred rapidly with a rotating paddle to bring it into contact with an air stream. During this stage energy is consumed primarily in the form of heat to melt the lead, followed by compressed air and powering of machines.

During the pasting process the cells are filled and covered with the lead oxide paste. During this stage electricity is used to power the machines. Afterwards they are cured in a temperature-controlled room during 32 hours; during this phase heat is used to prepare the paste and to control the room’s temperature (Jung et al., 2016Jung, J., Zhang, L., & Zhang, J. (2016). Lead-acid battery technologies. fundamentals, materials and applications. Florida: CRC Press.).

In the assembly process all the battery components are fitted into the body; once the battery is sealed it is ready to receive the electrolyte. During this stage energy is consumed primarily in terms of electricity and compressed air to power the machines and the devices involved in the assembly (Jung et al., 2016Jung, J., Zhang, L., & Zhang, J. (2016). Lead-acid battery technologies. fundamentals, materials and applications. Florida: CRC Press.).

The battery formation process consists in charging the battery for the first time; it involves chemical processes in the grids that transform them into active positive and negative electrodes. This process is crucial for the battery’s performance and useful life, and consequently it is performed based on pre-established patterns regarding voltage and current (Pavlov, 2011Pavlov, D. (2011). Lead-acid batteries: science and technology: a handbook of lead-acid battery technology and its Influence on the product. Amsterdam: Elsevier.). In starter batteries, the formation process is performed in special facilities called battery charging units (BCU), which perform the process in batches. This is the process that consumes most electric energy in the starter battery manufacturing process (Jung et al., 2016Jung, J., Zhang, L., & Zhang, J. (2016). Lead-acid battery technologies. fundamentals, materials and applications. Florida: CRC Press.).

2.2 Methodology

Approval of the ISO 50001 standard in 2011 was a fundamental step in the development of EM at the international level, because it established the general requirements for Energy Management Systems (EMS). Among other aspects, application of this standard involves the identification of the areas that have the most effect on energy consumption; forecasting and planning of energy consumption; identification of potential savings, and action plans to achieve such savings. The standard describes a four-stage process: energy policy, energy planning, implementation and verification, all as part of a continuous improvement cycle (Soto et al., 2014Soto, J., Borroto, A., Bah, M. A., González, R., Curbelo, M., & Díaz, A. M. (2014). Diseño y aplicación de un procedimiento para la planificación energética según la NC-ISO 50001: 2011. Ingeniería Energética, 35(1), 38-47.).

The energy planning phase and the activities that form part of it are considered the core of the EMS. This phase sets the foundations for the development of energy performance improvement strategies by setting specific and attainable objectives and by establishing measures to ensure their fulfillment. Figure 2 provides a schematic view of this phase.

Figure 2
Energy Planning.

In line with what is established by the ISO 50004 (ISO, 2014International Organization for Standardization – ISO. (2014). ISO 50004: energy management systems: Guidance for the implementation, maintenance and improvement of an energy management system. Geneva.) standard, the methodology used in this study has 6 steps:

  1. 1

    Analysis of energy consumption and use;

  2. 2

    Finding the energy baseline and goal line;

  3. 3

    Developing energy performance indicators (EPIn);

  4. 4

    Identification of areas with significant energy use;

  5. 5

    Identification of opportunities to improve energy performance;

  6. 6

    Implementation and evaluation.

3 Results and discussion

The study was carried out at a Colombian battery factory whose production has increased at a rate of 14% per year between 2012 (742,600 batteries) and 2015 (1,110,900 batteries), in an assortment of 168 battery types. The study reviewed consumption and production data between 2011 and 2014; the proposed improvement measures were implemented in early 2015, and the results were assessed during the same year.

3.1 Analysis of electricity consumption

Figure 3 displays monthly battery production and electric power consumption between 2011 and 2014, indicating that consumption has risen in line with production, which implies that improving energy efficiency is an important priority given its high incidence on production costs.

Figure 3
Monthly behavior of production and electricity consumption. 2011-2014.

In five of the months it was observed that the behavior of electricity consumption and production were not proportional: In February 2011, May 2012 and November 2014 battery production increased but electric power consumption dropped because most of the batteries produced were of lower capacity. In November 2011 the number of batteries produced fell and electric power consumption dropped only slightly because most batteries produced were of greater capacity. In March 2014 production decreased and power consumption increased because during that month a technical shut-down of the plant took place over several days, during which energy was consumed but no batteries were produced. Despite these exceptions, overall we find that electric power consumption is proportional to the number of batteries produced. The relationship between these two parameters is to be used as the energy performance indicator (EPIn) at the factory.

3.2 Finding the energy baseline and goal line

The energy baseline (EBL) is used as a benchmark against which to measure progress and shortcomings in the organization’s energy performance. It establishes the status of energy use at the beginning of the intervention.

In order to find the EBL, correlation analysis was performed between monthly electricity consumption and monthly battery production from 2011 to 2014; the results are displayed in Figure 4.

Figure 4
Energy baseline.

All the points included in the correlation analysis reflect actual operating conditions at the factory; statistical analysis of consumption values produced a standardized bias of 0.49 and standardized kurtosis of 0.24. Because the values are within the range of -2 and +2, we can assume that the data are normally distributed. The t-test yielded a P-value of 0.0012, indicating that the mean is different from 0.

According to the specialized literature on studies of this type based on actual operating data, if the coefficient of determination (R2 > 0.6), a baseline and EPIn model can be developed with good results, and if the coefficient is greater than 0.8, very good results can be expected (Deng, 2003Deng, S. (2003). Energy and water uses and their performance explanatory indicators in hotels in Hong Kong. Energy and Building, 35(8), 775-784. http://dx.doi.org/10.1016/S0378-7788(02)00238-4.
http://dx.doi.org/10.1016/S0378-7788(02)...
; Matson & Piette, 2005Matson, N. E., & Piette, M. A. (2005). High performance commercial building systems: review of California and National Benchmarking Methods. Working Draft. Berkeley: United States Government. Retrieved in 2016, August 15, from https://www.semanticscholar.org/paper/Review-of-California-and-National-Benchmarking-Piette-Lawrence/8c0a3ecbe7c21ddcb43625a2104e445136c2f009
https://www.semanticscholar.org/paper/Re...
; Becken et al., 2001Becken, S., Frampton, C., & Simmons, D. (2001). Energy consumption patterns in the accommodation sector: the New Zealand case. Ecological Economics, 39(3), 371-386. http://dx.doi.org/10.1016/S0921-8009(01)00229-4.
http://dx.doi.org/10.1016/S0921-8009(01)...
; Bohdanowicz & Martinac, 2007Bohdanowicz, P., & Martinac, I. (2007). Determinants and benchmarking of resource consumption in hotels: case study of Hilton International and Scandic in Europe. Energy and Building, 39(1), 82-95. http://dx.doi.org/10.1016/j.enbuild.2006.05.005.
http://dx.doi.org/10.1016/j.enbuild.2006...
; Castrillón et al., 2013Castrillón, R., González, A., & Quispe, E. (2013). Mejoramiento de la eficiencia energética en la industria del cemento por proceso húmedo a través de la implementación del sistema de gestión integral de la energía. Dyna, 80(177), 115-123.; Yanes & Gaitan, 2005Yanes, J. P. M., & Gaitan, O. G. (2005). Herramientas para la gestión energética empresarial. Sciences et Techniques, 3(29), 169-174.).

Figure 4 displays the results of the correlation analysis performed to find the baseline. The R2 statistic indicates that the adjusted model explains 75% of the variation in electricity consumption compared to the number of batteries produced. The P-value in the analysis of variance was 0.0004 for estimation of the slope and 0.0001 for estimation of the intercept; the fact that both values are less than 0.05 indicates that there is a statistically significant relationship between electricity consumption and the number of batteries produced at a 95% confidence level.

The lineal correlation found for EBL has a coefficient of determination R2 = 0.7519; since it is greater than 0.6, according to the specialized literature (Becken et al., 2001Becken, S., Frampton, C., & Simmons, D. (2001). Energy consumption patterns in the accommodation sector: the New Zealand case. Ecological Economics, 39(3), 371-386. http://dx.doi.org/10.1016/S0921-8009(01)00229-4.
http://dx.doi.org/10.1016/S0921-8009(01)...
; Bohdanowicz & Martinac, 2007Bohdanowicz, P., & Martinac, I. (2007). Determinants and benchmarking of resource consumption in hotels: case study of Hilton International and Scandic in Europe. Energy and Building, 39(1), 82-95. http://dx.doi.org/10.1016/j.enbuild.2006.05.005.
http://dx.doi.org/10.1016/j.enbuild.2006...
; Deng, 2003Deng, S. (2003). Energy and water uses and their performance explanatory indicators in hotels in Hong Kong. Energy and Building, 35(8), 775-784. http://dx.doi.org/10.1016/S0378-7788(02)00238-4.
http://dx.doi.org/10.1016/S0378-7788(02)...
; Matson & Piette, 2005Matson, N. E., & Piette, M. A. (2005). High performance commercial building systems: review of California and National Benchmarking Methods. Working Draft. Berkeley: United States Government. Retrieved in 2016, August 15, from https://www.semanticscholar.org/paper/Review-of-California-and-National-Benchmarking-Piette-Lawrence/8c0a3ecbe7c21ddcb43625a2104e445136c2f009
https://www.semanticscholar.org/paper/Re...
), the relationship between batteries produced and energy consumption may be used to develop an EPIn, and the baseline equation can be used for electricity consumption planning and evaluation purposes.

A reasonable and attainable goal is for energy consumption to approach the values that are below the EBL. Similarly, the points that are above the EBL can be used to estimate possible worsening of energy consumption under current plant conditions if no action is taken. Figure 5 shows the goal line (GL) calculated based on the points whose performance is better than the EBL, and the worsening line calculated based on the energy performance points that are above the EBL and which tend to affect EE and to worsen performance.

Figure 5
Baseline, goal line and worsen line.

The potential for savings without changes to the equipment is calculated based on the difference between the area under the EBL straight line and the area under the GL straight line. It is equal to 8% compared to current consumption, which would produce savings of 75,200 kWh per year. Possible worsening is calculated in a similar manner, yielding a result of 13%.

3.3 Construction of the EPIn.

The objective of the EPIn is to follow up on, monitor and control the company’s energy performance. The company’s performance indicator is obtained from the baseline Equation 1, as follows:

EPIn = Electricity consumption kWh Number of batteries produced (1)

Figure 6 displays in graphic form the behavior of EPIn vs monthly battery production, as well as the behavior of the GL indicator, the possible worsening of the indicator and some points reflecting actual months of operation at the plant. The points below the EPIn control curve have satisfactory energy performance, and the points above have deficient performance. Through the implementation of the energy savings actions at the company, energy performance is expected to approach the goal line indicator, indicating an improvement in energy performance.

Figure 6
Monthly control chart of the EPIn.

3.4 Identification of the main areas of energy use

In order to identify the main areas of energy use, simultaneous measurements were taken of overall electricity consumption at the plant and of the areas and equipment that presumably have greatest consumption. The measurements were taken using a portable Fluke model 435 II class A network analyzer. Figure 7 displays the Pareto diagram of the main energy users.

Figure 7
Pareto chart.

3.5 Main electricity users

As shown in Figure 7, the area of greatest electricity consumption is the battery charging unit (BCU), which accounts of 42% of the factory’s consumption, followed by the compressed air system, which accounts for 9%, and large motors, accounting for 8%.

3.6 Identification of opportunities to improve energy performance.

At each of the main energy usage areas the energy review procedure displayed in Figure 2 was performed, in order to identify savings opportunities that may improve energy performance.

3.6.1 Identification of savings opportunities in the BCU

The energy review focused on assessing the technical conditions of the charging tables and on identifying deficiencies or operating problems during the formation process that produce energy losses and consequently worsen the energy efficiency indicator. During the study, measurements were taken of electrical parameters related to losses and a thermographic survey was performed for all the battery charging circuits. Figure 8 displays the arrangement of the battery charging circuit connections.

Figure 8
Battery formation circuit chart.

At each circuit, the drop in tension and current between the connection points was measured, and losses were calculated based on Equation 2.

P = V I (2)

where: V = Difference in measured tension (V); I = Measured current (A); P = Power (W).

The above power is also calculated as:

P = I 2 R (3)

where: R = Resistance of circuit elements (Ω).

Equation 3 indicates that the losses are directly proportional to electrical resistance, given that the demand for current is constant for all types of battery. Resistance in turn depends on the conditions of the electrical conductors and points of connection.

At each circuit the power consumed was measured at the conductors and at the contact points between the cables and the battery terminals, based on which power consumption was measured using Equation 2. Taking into consideration the time the process takes, total energy losses were calculated (Wh) at the conductors and contacts of each charging circuit. Figure 9 shows the average of such losses at the circuits, indicating those with best and worst energy performance, finding a significant difference of approximately 2000 Wh, which indicates that the technical conditions of the conductors and contacts represent an opportunity for improvement of energy performance in the formation process.

Figure 9
Energy losses at the circuits with best and worst energy performance.

The incidence of the technical conditions of the conductors and contacts was confirmed by the results of the thermographic survey, which is displayed in Figure 10, showing that conductors and contacts in good conditions operate at 45°, whereas in others the temperature rises as high as 95 °C.

Figure 10
Thermographic analysis results.

Another source of inefficiency that was identified was the high level of tension of supply for the formation process, with an average for all circuits of 17.6 V; this is higher than the recommended 16 V (Kiessling, 1992Kiessling, R. (1992). Lead acid battery formation techniques. Shelton: Digatron Firing Circuits. Retrieved in 2016, August 15, from http://www.digatron.com/fileadmin/pdf/lead_acid.pdf
http://www.digatron.com/fileadmin/pdf/le...
; Pavlov, 2011Pavlov, D. (2011). Lead-acid batteries: science and technology: a handbook of lead-acid battery technology and its Influence on the product. Amsterdam: Elsevier.; Prout, 1993Prout, L. (1993). Aspects of lead/acid battery technology 4: plate formation. Journal of Power Sources, 41(1-2), 195-219. http://dx.doi.org/10.1016/0378-7753(93)80038-Q.
http://dx.doi.org/10.1016/0378-7753(93)8...
). Since energy is proportional to tension, in a scenario of constant current (Equation 2) this causes substantial over-consumption of energy, as well as an increase in Hydrogen and Oxygen emissions during the process (IEC, 2000International Electrotechnical Commission – IEC. (2000). IEC 60095-1: lead-acid starter batteries: part 1: general requirements and methods of test. London.; Pavlov, 2011Pavlov, D. (2011). Lead-acid batteries: science and technology: a handbook of lead-acid battery technology and its Influence on the product. Amsterdam: Elsevier.).

3.6.2 Actions to be implemented to improve energy performance in the batteries formation process

  • Establish requirements for use of intermediate conductors. Frequent inspections of their technical conditions;

  • Implement cleaning programs for connectors and other devices;

  • Implement systematic inspection with thermography to assess the quality of the process from an energy perspective;

  • Establish protocols for the manual connection of circuits;

  • Implement a frequent maintenance in the area to ensure cleanliness and good conditions of fixed contacts;

  • Re-design the connectors;

  • Set voltage supply in the batteries formation section at 16.4 V according to the possibilities of the transformer.

3.6.3 Identification of savings opportunities in the compressed air system

The compressed air system is in charge of supplying air in the required conditions of pressure and quality to all plant equipment and facilities that require it. The network installed throughout the plant is 942.6 m long with a volume of 4.12 m3; it is divided into two main components: generation and demand. The generation side consists of four modern and efficient compressors of the KAESER make model ASD 40S, each with flow of 162 Cubic feet per minute (CFM) and consumption of 30 kW; one KAESER TF 230 drying unit with flow of 671 CFM and consumption of 1.61 kW and one buffer tank with capacity of 1.13 m3.

Energy consumption measurements were taken during one week using a Fluke model 435 II class A portable network analyzer, to measure energy consumption and start-up and idling times of the compressors. It was found that total consumption is between 110 and 130 kWh, very close to its maximum value. The operating regime consists of three compressors working continuously and one compressor working in the ON/OFF mode, depending on the regulated pressure range of the system, which is set at Pmax = 108 Psi and Pmin = 100 Psi. The start-up and idling times are between 17 and 25 seconds, which is far below the values established by the manufacturer, which recommends minimum idling time of 2 minutes for compressors of this type.

This behavior may the result of inadequate system design, substantial air leaks, or both. An inspection of the network was performed with an AMPROVE TMULD 300 ultrasonic detector to identify places with substantial leaks, links with abrupt layouts, poorly designed reductions and sealing problems. To establish the value of the leaks, the procedure proposed by (Dindorf, 2012Dindorf, R. (2012). Estimating potential energy savings in compressed air systems. Procedia Engineering, 39, 204-211. http://dx.doi.org/10.1016/j.proeng.2012.07.026.
http://dx.doi.org/10.1016/j.proeng.2012....
; Saidur et al., 2010Saidur, R., Rahim, N. A., & Hasanuzzaman, M. (2010). A review on compressed-air energy use and energy savings. Renewable & Sustainable Energy Reviews, 14(4), 1135-1153. http://dx.doi.org/10.1016/j.rser.2009.11.013.
http://dx.doi.org/10.1016/j.rser.2009.11...
) was used, which consists in starting up the compressors with no demand in the system, bringing them up to working pressure and then shutting them off to find the average time it takes the pressure to fall below 50% of its nominal value. The value of the leaks was calculated based on such nominal value through the following Equation 4.

C = V P 1 P 2 t P 0 k (4)

where: C = Air leak capacity (m3/s); P1 = Test starting pressure (Psi); P2 = End of test pressure (Psi); t = Time it takes to reach the end of test pressure (sec.); P0 = Atmospheric pressure (Psi); V = Total volume of the system; k = Coefficient of correction to the normal pressure system; k = 1.25.

The results of the measurements and the value of the leaks are displayed in Table 1.

Table 1
Measurement results and percentage of leaks.

The average (Mean) value of the leaks was 34.61 and the standard deviation (σ) of the measurements was 2.49. Measurement number 4 was excluded from the sample because it lies outside the control range of the variable (Mean -σ, Mean +σ), which is between 31.8 and 36.8, and the final average value is 33.7%.

This average value of leaks is greater than that recommended in the literature, which indicates that it should be lower than 15% (Abdelaziz et al., 2011Abdelaziz, E. A., Saidur, R., & Mekhilef, S. (2011). A review on energy saving strategies in industrial sector. Renewable & Sustainable Energy Reviews, 15(1), 150-168. http://dx.doi.org/10.1016/j.rser.2010.09.003.
http://dx.doi.org/10.1016/j.rser.2010.09...
; Dindorf, 2012Dindorf, R. (2012). Estimating potential energy savings in compressed air systems. Procedia Engineering, 39, 204-211. http://dx.doi.org/10.1016/j.proeng.2012.07.026.
http://dx.doi.org/10.1016/j.proeng.2012....
), which implies that the leaks must be corrected.

If the system worked at the recommended values of leaks of between 10-15%, it would require a flow of 484 CFM. At this value, three compressors would be in operation and the other would be on standby as backup. Two of the three compressors in operation would be in continuous operation and the other would be in the ON/OFF mode, dependent of the pressure in the system. Calculations were performed to make the idling last 2 minutes, as recommended by the manufacturer, finding that a storage tank of 6.53 m3 capacity would be required, and that regulation of the generation system should be changed to the range of between Pmax = 120 Psi and Pmin = 100 Psi. This new system configuration would produce savings of 27% compared to the current system, which is equivalent to 8,793,865.98 COP per month.

3.6.3.1 Actions to be implemented to reduce energy consumption in the compressed air system

  • Establish a leak detection and correction program with maintenance personnel. The program will consist of inspecting the entire compressed air system to identify leaks and eliminate them through sealing or substitution of the required sections. The personnel will be equipped with an AMPROVE TMULD 300 ultrasonic leak detector and a Fluke Ti200 thermographic camera, as recommended by (Dudic et al., 2012Dudic, R., Ignjatovic, I., Šešlija, D., Blagojević, V., & Stojiljković, M. (2012). Leakage quantification of compressed air using ultrasound and infrared thermography. Measurement, 45(7), 1689-1694. http://dx.doi.org/10.1016/j.measurement.2012.04.019.
    http://dx.doi.org/10.1016/j.measurement....
    ; Dindorf, 2012Dindorf, R. (2012). Estimating potential energy savings in compressed air systems. Procedia Engineering, 39, 204-211. http://dx.doi.org/10.1016/j.proeng.2012.07.026.
    http://dx.doi.org/10.1016/j.proeng.2012....
    ; Saidur et al., 2010Saidur, R., Rahim, N. A., & Hasanuzzaman, M. (2010). A review on compressed-air energy use and energy savings. Renewable & Sustainable Energy Reviews, 14(4), 1135-1153. http://dx.doi.org/10.1016/j.rser.2009.11.013.
    http://dx.doi.org/10.1016/j.rser.2009.11...
    ; Abdelaziz et al., 2011Abdelaziz, E. A., Saidur, R., & Mekhilef, S. (2011). A review on energy saving strategies in industrial sector. Renewable & Sustainable Energy Reviews, 15(1), 150-168. http://dx.doi.org/10.1016/j.rser.2010.09.003.
    http://dx.doi.org/10.1016/j.rser.2010.09...
    );

  • Also, sections with layout design problems must be corrected;

  • Substitute the buffer tank for one with capacity equal to or greater than 6.53 m3;

  • Once the new tank is installed, increase the generation system regulation pressure to a range of between 100-120 Psi, with the objective of reducing sudden changes in demand and pressure drops and to increase the compressor start-up and idling interval, thereby reducing electricity consumption and increasing useful life.

3.6.4 Identification of savings opportunities in large electric motors

The operating features of the nine motors with greatest consumption were studied. Fluke model 435 II class A and Dranetz Power Visa portable network analyzers were used to measure the monthly energy consumption of each motor. The assessment of output power, the load factor and operating efficiency of the motor was performed using a method based on the data on the motor plates and catalogs (Hasanuzzaman et al., 2011Hasanuzzaman, M., Rahim, N. A., Saidur, R., & Kazi, S. N. (2011). Energy savings and emissions reductions for rewinding and replacement of industrial motor. Energy, 36(1), 233-240. http://dx.doi.org/10.1016/j.energy.2010.10.046.
http://dx.doi.org/10.1016/j.energy.2010....
). The assessment considers the effects of the harmonics generated by the frequency drives, by means of the model for losses due to the effect of harmonics indicated in the standard (ANSI, 2012American National Standard Motors and Generator – ANSI. American National Standards Institute – NEMA. (2012). NEMA MG 1-2012. Virginia.).

Table 2 displays the nominal data of the motors, the average and maximum values of the load factor and the operating efficiency of the motors, as well as the percent difference between nominal efficiency and maximum operating efficiency obtained in each motor.

Table 2
Output power, load factor and operating efficiency of the motors.

The table shows that motors M2, M3 and M9 are operating near nominal efficiency, whereas the operating efficiency of the remaining six motors is lower. In motors M1 and M4, the lower efficiency is due to the effect of harmonics generated by frequency drives. In motors M5 and M8 the lower efficiency is because they work at a load factor below 50%, whereas in motors M6 and M7 the lower efficiency is due to a combination of the harmonics effect and the low load factor (Chirindo et al., 2016Chirindo, M., Khan, M. A., & Barendse, P. S. (2016). Considerations for nonintrusive efficiency estimation of inverter-fed induction motors. IEEE Transactions on Industrial Electronics, 63(2), 741-749. http://dx.doi.org/10.1109/TIE.2015.2477801.
http://dx.doi.org/10.1109/TIE.2015.24778...
; Siraki & Pillay, 2012Siraki, A. G., & Pillay, P. (2012). An in situ efficiency estimation technique for induction machines working with unbalanced supplies. IEEE Transactions on Energy Conversion, 27(1), 85-95. http://dx.doi.org/10.1109/TEC.2011.2168563.
http://dx.doi.org/10.1109/TEC.2011.21685...
; Sousa et al., 2017Sousa, V., Hernández Herrera, H., Quispe, E. C., Viego, P. R., & Gómez, J. R. (2017). Harmonic distortion evaluation generated by PWM motor drives in electrical industrial systems. Iranian Journal of Electrical and Computer Engineering, 7(6), 3207-3216. http://dx.doi.org/10.11591/ijece.v7i6.pp3207-3216.
http://dx.doi.org/10.11591/ijece.v7i6.pp...
). Motors M1, M2, M4, M6 and M7 operate with frequency drives, whereas the other motors use soft starters.

3.6.4.1 Actions to reduce energy consumption in electric motors

Replace motors to improve operating efficiency.

In order to reduce energy consumption of the motors, the proposal is to replace the current motors for new ones that operate at a higher load factor and level of efficiency (Siraki & Pillay, 2012Siraki, A. G., & Pillay, P. (2012). An in situ efficiency estimation technique for induction machines working with unbalanced supplies. IEEE Transactions on Energy Conversion, 27(1), 85-95. http://dx.doi.org/10.1109/TEC.2011.2168563.
http://dx.doi.org/10.1109/TEC.2011.21685...
). An economic feasibility analysis was performed using the Simple Return on Investment method (SROI) (Hasanuzzaman et al., 2011Hasanuzzaman, M., Rahim, N. A., Saidur, R., & Kazi, S. N. (2011). Energy savings and emissions reductions for rewinding and replacement of industrial motor. Energy, 36(1), 233-240. http://dx.doi.org/10.1016/j.energy.2010.10.046.
http://dx.doi.org/10.1016/j.energy.2010....
), which takes into consideration the cost of the new motor, lower expenses due to energy savings and the residual value of the equipment to be replaced.

Table 3 shows the maximum operating load factor and the maximum operating efficiency of the current motors (a) and the new proposed motors (n); estimated monthly energy savings (ES) and the corresponding SROI. For motors M2 and M9 no replacement is proposed because they have a good load factor and premium efficiency; M3 has similar behavior, but it is of standard efficiency, so the proposal is to change it for one with premium efficiency.

Table 3
Nominal and operating data of the motors and monthly energy savings.

The above table shows total potential energy savings of 2.272 kWh/ month, and that the return on the investment is less than 3 months, due to the high potential energy savings and the high residual value of the current motors.

Replace unnecessary frequency drives for soft starters.

Motors M1, M2 and M4 operate with unnecessary frequency drives, because their load is essentially constant; consequently, the proposal is to replace the frequency drives for soft starters. Table 4 displays the maximum and average values of THDV, annual energy losses due to the effect of harmonics calculated using the model of standard (ANSI, 2012American National Standard Motors and Generator – ANSI. American National Standards Institute – NEMA. (2012). NEMA MG 1-2012. Virginia.) and the SROI of the proposed change.

Table 4
Result of the analysis of harmonics in motors.

As shown in the table, THDV is above 3%, the limit established by the standard (ANSI, 2012American National Standard Motors and Generator – ANSI. American National Standards Institute – NEMA. (2012). NEMA MG 1-2012. Virginia.), which produces energy losses due to harmonics of 28,776 kWh. The return on investment in these units is less than one year because of their high residual value.

3.7 Implementation and evaluation

The proposed actions to save electricity were implemented in late 2015, producing significant improvements in energy performance. A major achievement was to reduce leakage in the compressed air system from 34.61% to 19.5%. In the battery formation area, a protocol was implemented to review the conductors and contact points of the formation tables that includes cleaning and measurement of contact resistance. In the motors area, the frequency drives of motors M1, M4 and M2 were replaced for soft starters and motors M3 and M5 were replaced for motors with greater efficiency and appropriate power as per Table 3.

Between January and July 2016, management performed monthly analysis of the company’s energy performance. It evaluated the results of the measures that were implemented and undertook corrective actions as required in response to deviations. Figure 11 shows the results of the six-month evaluation. Despite the significant increase in battery production and the consequent increase in energy consumption, the energy performance indicator remained below the EBL and above the goal line that was initially established.

Figure 11
Results of the monthly analysis of energy performance at the company.

Table 5 displays monthly energy savings, calculated as the difference between forecast energy consumption according to the EBL and actual energy consumption. Over the entire period energy savings totaled 201,934 kWh (3.48%); the highest monthly savings totaled 47,548 kWh (4.68%) and the lowest monthly savings totaled 16,270 kWh (1.89%).

Table 5
Total and monthly energy savings.

4 Conclusions

The study found that implementation of the Energy Review procedure established in ISO 50001 (see Figure 2) enabled a substantial improvement in energy performance at the battery factory.

The methodology of the intervention enabled establishing the IDEn and baseline for the major areas of electricity consumption at the factory, as well as the procedures for their systematic assessment, which helps lay the groundwork to design and implement an EMS according to ISO 50001.

The actions carried out in the areas identified as major energy consumers produced a 3.48% reduction in electricity consumption (21,934 kWh). Consequently, as additional actions are implemented in the future, the company will continue to improve its energy performance and reduce its electricity consumption.

  • How to cite: Noriega Angarita, E., Cabello Eras, J. J., Hernández Herrera, H., Sousa Santos, V., Balbis Morejón, M., Silva Ortega, J. I., & Sagastume Gutiérrez, A. (2019). Energy planning and management during battery manufacturing. Gestão & Produção, 26(4), e3928. https://doi.org/10.1590/0104-530X3928-19
  • Financial support: None.

References

  • Abdelaziz, E. A., Saidur, R., & Mekhilef, S. (2011). A review on energy saving strategies in industrial sector. Renewable & Sustainable Energy Reviews, 15(1), 150-168. http://dx.doi.org/10.1016/j.rser.2010.09.003
    » http://dx.doi.org/10.1016/j.rser.2010.09.003
  • American National Standard Motors and Generator – ANSI. American National Standards Institute – NEMA. (2012). NEMA MG 1-2012 Virginia.
  • Aragon, C. S., Pamplona, E., & Vidal Medina, J. R. (2013). Identification of energy efficiency investments and their risk assessment. Gestão & Produção, 20(3), 525-536.
  • Becken, S., Frampton, C., & Simmons, D. (2001). Energy consumption patterns in the accommodation sector: the New Zealand case. Ecological Economics, 39(3), 371-386. http://dx.doi.org/10.1016/S0921-8009(01)00229-4
    » http://dx.doi.org/10.1016/S0921-8009(01)00229-4
  • Bohdanowicz, P., & Martinac, I. (2007). Determinants and benchmarking of resource consumption in hotels: case study of Hilton International and Scandic in Europe. Energy and Building, 39(1), 82-95. http://dx.doi.org/10.1016/j.enbuild.2006.05.005
    » http://dx.doi.org/10.1016/j.enbuild.2006.05.005
  • Bunse, K., Vodicka, M., Schönsleben, P., Brülhart, M., & Ernst, F. O. (2011). Integrating energy efficiency performance in production management: gap analysis between industrial needs and scientific literature. Journal of Cleaner Production, 19(6-7), 667-679. http://dx.doi.org/10.1016/j.jclepro.2010.11.011
    » http://dx.doi.org/10.1016/j.jclepro.2010.11.011
  • Cabello Eras, J. J., Sagastume Gutiérrez, A., García Lorenzo, D., Cogollos Martínez, J. B., Hens, L., & Vandecasteele, C. (2015). Bridging universities and industry through cleaner production activities: experiences from the Cleaner Production Center at the University of Cienfuegos, Cuba. Journal of Cleaner Production, 108, 873-882. http://dx.doi.org/10.1016/j.jclepro.2014.11.063
    » http://dx.doi.org/10.1016/j.jclepro.2014.11.063
  • Cabello Eras, J. J., Sousa Santos, V., Sagastume Gutiérrez, A., Guerra Plasencia, M. Á., Haeseldonckx, D., & Vandecasteele, C. (2016). Tools to improve forecasting and control of the electricity consumption in hotels. Journal of Cleaner Production, 137, 803-812. http://dx.doi.org/10.1016/j.jclepro.2016.07.192
    » http://dx.doi.org/10.1016/j.jclepro.2016.07.192
  • Cagno, E., & Trianni, A. (2014). Evaluating the barriers to specific industrial energy efficiency measures: an exploratory study in small and medium-sized enterprises. Journal of Cleaner Production, 82, 70-83. http://dx.doi.org/10.1016/j.jclepro.2014.06.057
    » http://dx.doi.org/10.1016/j.jclepro.2014.06.057
  • Camioto, F. C., Rebelatto, D. A. N., & Rocha, R. T. (2015). Análise da eficiência energética nos países do BRICS: um estudo envolvendo a Análise por Envoltória de Dados. Gestão & Produção, 23(1), 192-203. http://dx.doi.org/10.1590/0104-530X1567-13
    » http://dx.doi.org/10.1590/0104-530X1567-13
  • Cañizares, G., Cuevas, M., Pérez, R. A., & González, E. (2015). Diseño e integración del sistema de gestión de la energía al sistema de gestión de la calidad en la ronera central” Agustín Rodríguez Mena. Sobre los Derivados de la Caña de Azúcar, 49(1), 46-52.
  • Castrillón, R., González, A., & Quispe, E. (2013). Mejoramiento de la eficiencia energética en la industria del cemento por proceso húmedo a través de la implementación del sistema de gestión integral de la energía. Dyna, 80(177), 115-123.
  • Castro, F., Aparecida, D., & Teixeira, R. (2015). Análise da eficiência energética nos países do BRICS: um estudo envolvendo a Análise por Envoltória de Dados. Gestão & Produção, 23(1), 192-203.
  • Chan, Y., & Kantamaneni, R. (2015). Study on energy efficiency and energy saving potential in industry and on possible policy mechanisms London: ICF Consulting. Retrieved in 2016, August 15, from https://ec.europa.eu/energy/sites/ener/files/documents/151201 DG ENER Industrial EE study - final report_clean_stc.pdf
    » https://ec.europa.eu/energy/sites/ener/files/documents/151201
  • Chirindo, M., Khan, M. A., & Barendse, P. S. (2016). Considerations for nonintrusive efficiency estimation of inverter-fed induction motors. IEEE Transactions on Industrial Electronics, 63(2), 741-749. http://dx.doi.org/10.1109/TIE.2015.2477801
    » http://dx.doi.org/10.1109/TIE.2015.2477801
  • Christoffersen, L. B., Larsen, A., & Togeby, M. (2006). Empirical analysis of energy management in Danish industry. Journal of Cleaner Production, 14(5), 516-526. http://dx.doi.org/10.1016/j.jclepro.2005.03.017
    » http://dx.doi.org/10.1016/j.jclepro.2005.03.017
  • Deng, S. (2003). Energy and water uses and their performance explanatory indicators in hotels in Hong Kong. Energy and Building, 35(8), 775-784. http://dx.doi.org/10.1016/S0378-7788(02)00238-4
    » http://dx.doi.org/10.1016/S0378-7788(02)00238-4
  • Dindorf, R. (2012). Estimating potential energy savings in compressed air systems. Procedia Engineering, 39, 204-211. http://dx.doi.org/10.1016/j.proeng.2012.07.026
    » http://dx.doi.org/10.1016/j.proeng.2012.07.026
  • Dudic, R., Ignjatovic, I., Šešlija, D., Blagojević, V., & Stojiljković, M. (2012). Leakage quantification of compressed air using ultrasound and infrared thermography. Measurement, 45(7), 1689-1694. http://dx.doi.org/10.1016/j.measurement.2012.04.019
    » http://dx.doi.org/10.1016/j.measurement.2012.04.019
  • European Commission – EC. (2014). Communication from the commission to the European parliament and the council energy efficiency and its contribution to energy security and the 2030 Framework for climate and energy policy Brussels. Retrieved in 2016, August 15, from https://ec.europa.eu/energy/sites/ener/files/ documents/2014_energy_efficiency_communication.pdf
    » https://ec.europa.eu/energy/sites/ener/files/
  • Fawkes, S., Oung, K., & Thorpe, D. (2016). Best practices and case studies for industrial energy efficiency improvement: an introduction for policy makers Copenhagen: DTU. Retrieved in 2016, August 15, from http://www.unepdtu.org/-/media/Sites/energyefficiencycentre/Publications/C2E2 Publications/Best-Practises-for-Industrial-EE_web.ashx?la=da
    » http://www.unepdtu.org/-/media/Sites/energyefficiencycentre/Publications/C2E2
  • Giacone, E., & Mancò, S. (2012). Energy efficiency measurement in industrial processes. Energy, 38(1), 331-345. http://dx.doi.org/10.1016/j.energy.2011.11.054
    » http://dx.doi.org/10.1016/j.energy.2011.11.054
  • Gielen, D., & Taylor, P. (2009). Indicators for industrial energy efficiency in India. Energy, 34(8), 962-969. http://dx.doi.org/10.1016/j.energy.2008.11.008
    » http://dx.doi.org/10.1016/j.energy.2008.11.008
  • Hasanuzzaman, M., Rahim, N. A., Saidur, R., & Kazi, S. N. (2011). Energy savings and emissions reductions for rewinding and replacement of industrial motor. Energy, 36(1), 233-240. http://dx.doi.org/10.1016/j.energy.2010.10.046
    » http://dx.doi.org/10.1016/j.energy.2010.10.046
  • Hens, L., Cabello-Eras, J. J., Sagastume-Gutiérez, A., Garcia-Lorenzo, D., Cogollos-Martinez, J. B., & Vandecasteele, C. (2017). University-industry interaction on cleaner production: the case of the Cleaner Production Center at the University of Cienfuegos in Cuba, a country in transition. Journal of Cleaner Production, 142, 63-68. http://dx.doi.org/10.1016/j.jclepro.2015.10.105
    » http://dx.doi.org/10.1016/j.jclepro.2015.10.105
  • International Electrotechnical Commission – IEC. (2000). IEC 60095-1: lead-acid starter batteries: part 1: general requirements and methods of test London.
  • International Organization for Standardization – ISO. (2011). ISO 50001: energy management systems: requirements with guidance for use Geneva.
  • International Organization for Standardization – ISO. (2014). ISO 50004: energy management systems: Guidance for the implementation, maintenance and improvement of an energy management system Geneva.
  • Jung, J., Zhang, L., & Zhang, J. (2016). Lead-acid battery technologies. fundamentals, materials and applications Florida: CRC Press.
  • Kaygusuz, K. (2012). Energy for sustainable development: a case of developing countries. Renewable & Sustainable Energy Reviews, 16(2), 1116-1126. http://dx.doi.org/10.1016/j.rser.2011.11.013
    » http://dx.doi.org/10.1016/j.rser.2011.11.013
  • Kiessling, R. (1992). Lead acid battery formation techniques Shelton: Digatron Firing Circuits. Retrieved in 2016, August 15, from http://www.digatron.com/fileadmin/pdf/lead_acid.pdf
    » http://www.digatron.com/fileadmin/pdf/lead_acid.pdf
  • Matson, N. E., & Piette, M. A. (2005). High performance commercial building systems: review of California and National Benchmarking Methods Working Draft. Berkeley: United States Government. Retrieved in 2016, August 15, from https://www.semanticscholar.org/paper/Review-of-California-and-National-Benchmarking-Piette-Lawrence/8c0a3ecbe7c21ddcb43625a2104e445136c2f009
    » https://www.semanticscholar.org/paper/Review-of-California-and-National-Benchmarking-Piette-Lawrence/8c0a3ecbe7c21ddcb43625a2104e445136c2f009
  • Miloloza, I. (2013). Tendencies of development of global battery market with emphasis on Republic of Croatia. Interdisciplinary Description of Complex Systems, 11(3), 318-333. http://dx.doi.org/10.7906/indecs.11.3.3
    » http://dx.doi.org/10.7906/indecs.11.3.3
  • Ospino-Castro, A. (2010). Análisis del potencial energético solar en la Región Caribe para el diseño de un sistema fotovoltaico. INGECUC, 6(6), 1-8. Retrieved in 2016, August 15, from http://revistascientificas.cuc.edu.co/index.php/ingecuc/article/view/296
    » http://revistascientificas.cuc.edu.co/index.php/ingecuc/article/view/296
  • Palamutcu, S. (2010). Electric energy consumption in the cotton textile processing stages. Energy, 35(7), 2945-2952. http://dx.doi.org/10.1016/j.energy.2010.03.029
    » http://dx.doi.org/10.1016/j.energy.2010.03.029
  • Pavlov, D. (2011). Lead-acid batteries: science and technology: a handbook of lead-acid battery technology and its Influence on the product Amsterdam: Elsevier.
  • Posch, A., Brudermann, T., Braschel, N., & Gabriel, M. (2015). Strategic energy management in energy-intensive enterprises: a quantitative analysis of relevant factors in the Austrian paper and pulp industry. Journal of Cleaner Production, 90, 291-299. http://dx.doi.org/10.1016/j.jclepro.2014.11.044
    » http://dx.doi.org/10.1016/j.jclepro.2014.11.044
  • Prout, L. (1993). Aspects of lead/acid battery technology 4: plate formation. Journal of Power Sources, 41(1-2), 195-219. http://dx.doi.org/10.1016/0378-7753(93)80038-Q
    » http://dx.doi.org/10.1016/0378-7753(93)80038-Q
  • Rantik, M. (1999). Life cycle assessment of five batteries for electric vehicles under different charging regimes (KFB-Meddelande, 28). Goteborg: KFB.
  • Report Buyer Ltd. (2015). Global and China lead-acid battery industry report, 2015-2018 London. Retrieved in 2016, August 15, from http://www.prnewswire.com/news-releases/global-and-china-lead-acid-battery-industry-report-2015-2018-300200529.html
    » http://www.prnewswire.com/news-releases/global-and-china-lead-acid-battery-industry-report-2015-2018-300200529.html
  • Rudberg, M., Waldemarsson, M., & Lidestam, H. (2013). Strategic perspectives on energy management: a case study in the process industry. Applied Energy, 104, 487-496. http://dx.doi.org/10.1016/j.apenergy.2012.11.027
    » http://dx.doi.org/10.1016/j.apenergy.2012.11.027
  • Rydh, C. J. (1999). Environmental assessment of vanadium redox and lead-acid batteries for stationary energy storage. Journal of Power Sources, 80(1-2), 21-29. http://dx.doi.org/10.1016/S0378-7753(98)00249-3
    » http://dx.doi.org/10.1016/S0378-7753(98)00249-3
  • Rydh, C. J., & Sandén, B. A. (2005). Energy analysis of batteries in photovoltaic systems. Part I: performance and energy requirements. Energy Conversion and Management, 46(11-12), 1957-1979. http://dx.doi.org/10.1016/j.enconman.2004.10.003
    » http://dx.doi.org/10.1016/j.enconman.2004.10.003
  • Saidur, R., Rahim, N. A., & Hasanuzzaman, M. (2010). A review on compressed-air energy use and energy savings. Renewable & Sustainable Energy Reviews, 14(4), 1135-1153. http://dx.doi.org/10.1016/j.rser.2009.11.013
    » http://dx.doi.org/10.1016/j.rser.2009.11.013
  • Siraki, A. G., & Pillay, P. (2012). An in situ efficiency estimation technique for induction machines working with unbalanced supplies. IEEE Transactions on Energy Conversion, 27(1), 85-95. http://dx.doi.org/10.1109/TEC.2011.2168563
    » http://dx.doi.org/10.1109/TEC.2011.2168563
  • Soto, J., Borroto, A., Bah, M. A., González, R., Curbelo, M., & Díaz, A. M. (2014). Diseño y aplicación de un procedimiento para la planificación energética según la NC-ISO 50001: 2011. Ingeniería Energética, 35(1), 38-47.
  • Sousa, V., Hernández Herrera, H., Quispe, E. C., Viego, P. R., & Gómez, J. R. (2017). Harmonic distortion evaluation generated by PWM motor drives in electrical industrial systems. Iranian Journal of Electrical and Computer Engineering, 7(6), 3207-3216. http://dx.doi.org/10.11591/ijece.v7i6.pp3207-3216
    » http://dx.doi.org/10.11591/ijece.v7i6.pp3207-3216
  • Sullivan, J. L., & Gaines, L. (2012). Status of life cycle inventories for batteries. Energy Conversion and Management, 58, 134-148. http://dx.doi.org/10.1016/j.enconman.2012.01.001
    » http://dx.doi.org/10.1016/j.enconman.2012.01.001
  • Vine, E. (2005). An international survey of the energy service company ESCO industry. Energy Policy, 33(5), 691-704. http://dx.doi.org/10.1016/j.enpol.2003.09.014
    » http://dx.doi.org/10.1016/j.enpol.2003.09.014
  • Weinert, N., Chiotellis, S., & Seliger, G. (2011). Methodology for planning and operating energy-efficient production systems. CIRP Annals Manufacturing Technology, 60(1), 41-44. http://dx.doi.org/10.1016/j.cirp.2011.03.015
    » http://dx.doi.org/10.1016/j.cirp.2011.03.015
  • Yanes, J. P. M., & Gaitan, O. G. (2005). Herramientas para la gestión energética empresarial. Sciences et Techniques, 3(29), 169-174.

Publication Dates

  • Publication in this collection
    10 Oct 2019
  • Date of issue
    2019

History

  • Received
    26 Apr 2017
  • Accepted
    24 Nov 2017
Universidade Federal de São Carlos Departamento de Engenharia de Produção , Caixa Postal 676 , 13.565-905 São Carlos SP Brazil, Tel.: +55 16 3351 8471 - São Carlos - SP - Brazil
E-mail: gp@dep.ufscar.br