Background:

Transcatheter aortic valve implantation (TAVI) has become a therapeutic option for high-risk or non-operable patients with severe symptomatic aortic stenosis. Atrioventricular conduction disturbances requiring permanent pacemaker (PPM) are a common and clinically important complication.

Objectives:

To evaluate the incidence of conduction disorders (CDs) after TAVI and the need for subsequent PPM implantation. To identify the predictors of postoperative PPM implantation.

Methods:

Retrospective study. All patients who underwent TAVI in a public hospital from December/2011 to June/2016 were included. Multivariate analysis was conducted to establish the predictor of permanent pacemaker implantation. Survival curves were constructed by the Kaplan-Meyer method. Statistically significant variables were those with p value < 0.05.

Results:

64 patients with AS underwent TAVI. Eleven patients were excluded. TAVI induced a new CD in 40 (77%) of the remaining 53 patients. The most common new CDs were 3rd degree AV block (32%) and left bundle branch block (30%). Sixteen patients (30,2%) underwent PPM implantation during the index hospitalization. On univariate analysis the risk factors for PPM implantation were CoreValve® use (OR: 1,76; P = 0,005), larger prosthesis implantation (P = 0,015), presence of a QRS ≥ 120 ms (OR: 5,62; P = 0,012), and 1st degree AV block (OR: 13; P = 0.008). On multivariate analysis the presence of 1st degree AV block predicted the need for PPM.

Conclusion:

TAVI induced CDs requiring PPM in 30% of the patients. The presence of 1st degree AV block predicted the need for PPM.

Keywords:
Atrioventricular Block; Bundle-Branch Block; Aortic Valve Stenosis/therapy; Transcatheter Aortic Valve Implantation/methods