A Sensitive Voltammetric Determination of Anti-Parkinson Drug Pramipexole Using Titanium Dioxide Nanoparticles Modified Carbon Paste Electrode

Abstract

In this study, a facile sensor based on TiO2 nanoparticles modified carbon paste electrode was developed for voltammetric determination of pramipexole in pharmaceutical formulations and biological samples. Surface of the fabricated electrode have been characterized using field emission scanning electron microscopy. Under the optimized experimental conditions, the modified electrode was exhibited excellent electrocatalytic activities and a sensitive oxidation peak at 0.9 V in the phosphate solution of pH 5.0 for electrooxidation of pramipexole. The plot of pH vs. Ep generated a slope of 62.5 mV per pH in the pH range of 3.0-13.0 indicating the contribution of an equal number of electrons and protons in the electrode process. A differential pulse voltammetry method was developed in the concentration range of 0.46-100 μmol L-1 with a limit of detection of 0.14 μmol L-1. The proposed method is simple, rapid, and inexpensive and also showed good selectivity and sensitivity toward pramipexole.

Keywords:
pramipexole; TiO2 nanoparticles; modified CPE; differential pulse voltammetry; electroanalysis


Introduction

Parkinson's disease is a common neurodegenerative disorder disease; it affects few parts of the brain which controls vital muscle movement. Pramipexole dihydrochloride monohydrate (PRX) is a widely preferred drug for the treatment of Parkinson's disease, since it has a direct activity on the central nervous system.11 Leentjens, A. F. G.; Drugs 2011, 71, 273. PRX, chemically known as (6S)-N6-propyl-4,5,6,7-tetrahydro-1,3-benzothiazole-2,6-diamine, is a dopaminergic agonist drug and the chemical structure is shown in Scheme 1. It has the capability to excite dopamine receptors in the striatum and is used for the treatment of depressive syndromes.22 Lavudu. P.; Rani, A. P.; Sekaran, C. B.; Kumar, K. S.; Ramesh, A.; Chem. Sci. J. 2012, 3, 1.,33 Leentjens, F. G.; Koester, J.; Fruh, B.; Toby, D.; Shephard, S.; Barone, P.; Houben, J. G.; Clin. Ther. 2009, 31, 89. Since 1997, the US government has approved the PRX drug to treat Parkinson's disease; the healing importance of PRX has made researchers to develop sensitive, selective, reliable and rapid analytical methods.

Scheme 1
Chemical structure of PRX.

There are many methods currently available for the determination of PRX such as UV-Vis spectrophotometry,44 Srinu, B. G.; Raju, C.; Asian J. Chem. 2007, 19, 816. high-performance liquid chromatography (HPLC) with ultraviolet and electrochemical detection,55 Lau, Y. Y.; Hanson, G. D.; Ichhpurani, N.; J. Chromatogr. B 1996, 683, 217. high-performance liquid chromatography-mass spectrometry (HPLC-MS),66 Lau, Y. Y.; Selenka, J. M.; Hanson, G. D.; Talat, R.; Ichhpurani, N.; J. Chromatogr. B 1996, 683, 209. HPLC with Monte Carlo simulations,77 Pathare, D. B.; Jadhav, A. S.; Shingare, M. S.; J. Pharm. Biomed. Anal. 2006, 41, 1152. spectrophotometry method based on the diazotization of primary amine group of pramipexole,88 Gurupadayya, B. M.; Vishwajith, V.; Srujana, N.; World J. Chem. 2009, 4, 157. gas chromatography mass spectrometry (GC-MS),99 Jayesh, G. P.; Ravindra, V. P.; Shobhana, K. M.; Biomed. Chromatogr. 2011, 25, 524. thin layer chromatography1010 Shubhangi, M. P.; Sunil, R. D.; J. Liq. Chromatogr. Relat. Technol. 2011, 34, 1664. and capilary electrophoresis with laser induced fluorescence detection.1111 Alessandro, M.; Ernst, K.; Emanuele, M.; Anal. Chim. Acta 2008, 626, 89. Furthermore, the above mentioned methods such as chromatographic methods require expensive instruments, organic solvents, reagents for the extraction and often time-consuming and hence, sensitive, reliable, and simple analytical methods were required to determine PRX.1212 Aref, M. A.; Raoof, J. B.; Ojani, R.; Colloids Surf. B 2013, 109, 287.

In the field of analytical chemistry, electrochemical methods have been widely attracted due to higher reliability, simplicity, rapid detection, high sensitivity and possibility of miniaturization.1313 Raoof, J. B.; Ojani, R.; Baghayeri, M.; Aref, M. A.; Anal. Methods 2012, 4, 157. Metal nanoparticles are very increasingly used for the electrode modification due to their extraordinary catalytic activities over corresponding bulk metal electrodes.1414 Lin, X.; Li, Y.; Biosens. Bioelectron. 2006, 22, 253. The unique chemical and physical properties of nanoparticles make them extremely suitable for designing and improving sensing devices, especially electrochemical and biosensors. Different kinds of nanomaterials, such as metals, metal oxides, carbon based materials and semiconductor nanoparticles, have been used for constructing electrochemical sensors and biosensors.1515 Ghavami, R.; Salimi, A.; Navaee, A.; Biosens. Bioelectron. 2011, 26, 3864. TiO2 nanoparticles have excellent chemical and physical properties; they have been used in the sensor preparation, coating, solar cell, and photocatalyst applications.1616 O'Regan, B.; Gratzel, M.; Nature 1991, 353, 737.,1717 Macak, J. M.; Barczuk, P. J.; Tsuchiya, H.; Nowakowska, G. A.; Chojak, M.; Bauer, S.; Virtanen, S.; Kulesza P. J.; Schmuki, P.; Electrochem. Commun. 2005, 7, 1417. These nanoparticles have been incorporated with other compounds, such as graphite and carbon nanotubes, to make modified electrodes in the electrochemical analysis of some biological compounds,1818 Qingwen, L.; Yiming, W.; Guoan, L.; Mater. Sci. Eng. C 2000, 11, 71.

19 Li, G.; Qu, J.; Zhang, X.; Ge, J.; Water Res. 2006, 40, 213.

20 Lo, P. H.; Kumar, S. A.; Chen, S. M.; Colloids Surf. B 2008, 66, 266.

21 Raoof, J. B.; Ojani, R.; Baghayeri, M.; Chin. J. Catal. 2011, 32, 1685.
-2222 Lunsford, S. K.; Choi, H.; Stinson, J.; Yeary, A.; Dionysiou, D. D.; Talanta 2007, 73, 172. because they provide more active sites at the surface of the electrode. TiO2 nanoparticles can be used in wide potential windows and improve the stability of the electrode, therefore, increase the repeatability of the electrode response. The carbon paste electrodes (CPEs) are very popular due to their wide anodic potential range, low residual current, ease of fabrication, easy renewal and low cost.2323 Mashhadizadeh, M. H.; Afshar, E.; Electrochim. Acta 2013, 87, 816.

Up-to-date, no voltammetric procedure was described using a carbon paste electrode modified with TiO2 nanoparticles for the quantification of PRX drug in the pharmaceutical or biological samples. In the present study, we fabricated a new sensor based on TiO2 nanoparticles modified carbon paste electrode (TiO2NPs/CPE) for the electrochemical determination of PRX.

Experimental

Reagents and materials

All utilized materials were of analytical reagent grade and used as purchased, without further purification and all solutions were prepared freshly with deionized water. Pramipexole dihydrochloride monohydrate (> 95% purity) and TiO2 nanoparticle (nanoparticles ca. 21 nm, > 99.5%) were purchased from Sigma-Aldrich (St. Louis, MO, USA). Two series of pramipexole tablet containing different doses (0.35 and/or 0.7 mg) were obtained from Dr. Abidi pharmaceutical company (Tehran, Iran). Graphite powder and paraffin oil (d = 0.88 g cm-3 as the binding agent (both from Daejung company, Shiheung, Korea) were used for preparing the paste. The biological samples used in this work were obtained from Blood Transfusion Organization (Babol, Iran). Potassium chloride from Fluka (Buchs, Switzerland) was used as the supporting electrolyte. Potassium ferricyanide (K4Fe(CN)6) was purchased from Merck company (Merck, Darmstadt, Germany) and used as the standard redox system.

Apparatus

The morphology of the modified electrode (TiO2NPs/CPE) was obtained using field emission scanning electron microscopy (FESEM) on a MIRA 3 XM TESCAN instrument with the operation of 5.0 kV. A digital pH meter (Hana, USA) was used to read the pH of the solutions. The electrochemical experiments were performed at room temperature using potentiostat/galvanostat electrochemical analyzer (SAMA500, Iran) with a voltammetry cell in a three electrodes configuration. The platinum wire and Ag|AgCl|KCl (3 mol L-1 were used as auxiliary and reference electrodes, respectively. The bare CPE and TiO2 nanoparticles modified CPE (TiO2NPs/CPE) were used as the working electrodes.

Preparation of the working electrode

In a typical electrode preparation, diethyl ether was added to a mixture of 0.03 g TiO2NPs and 0.17 g of graphite powder. After hand mixing with a mortar and pestle, the solvent was evaporated with stirring. Then, paraffin oil (35 wt.%) was blended with the mixture in a mortar by hand mixing for 30 min until a uniformly wetted paste was obtained. This paste was packed into the end of a glass tube (ca. 0.35 cm i.d. and 10 cm long) and the copper wire was utilized for electrical contact. A new surface was achieved by pushing an excess of the paste out of the tube and polishing with a weighing paper. For comparison, bare CPE was also prepared in the same way in the absence of TiO2NPs.

Analytical procedure

A series of phosphate solutions (0.1 mol L-1 in the pH range of 3.0-13.0 were prepared by mixing stock solutions of 0.1 mol L-1 H3PO4, KH2PO4, K2HPO4 and K3PO4, and used as supporting electrolytes. A stock solution of 1.0 × 10-2 mol L-1 pramipexole was prepared daily by dissolving 0.1056 g pramipexole in 50 mL water and then stored at 4 ºC. Standard solutions were prepared using this stock solution by accurate dilution with water in the proposed concentration range (0.46-100 μmol L-1. The working solutions were prepared by mixing appropriate volume of stock solution, phosphate solutions and 1 M KCl as supporting electrolyte. The differential pulse voltammograms (DPVs) were recorded by applying positive potential scan from 0.0-1.5 V vs. Ag|AgCl|KCl (3 mol L-1), and pulse amplitude and scan increment of 50 and 25 mV s-1, respectively. All voltammetric measurements were carried out at ambient temperature.

Assay of the PRX in tablets

The contents of ten tablets were finely crushed with mortar and pestle to form a fine homogenous powder. Subsequently, a quantity equivalent to one tablet was collected and dissolved in a 100 mL volumetric flask with deionized water and sonicated for 15 min. The samples from the clear liquor were withdrawn and quantitatively diluted with the selected supporting electrolyte (0.1 mol L-1 phosphate solution, pH = 5.0). The content of the drug in the tablet was determined by referring to the calibration graph or regression equation and recovery percentages were calculated to examine the accuracy of the proposed method.

Determination of PRX in human plasma samples

Serum samples obtained from healthy individuals (after having obtained their written consent) were stored frozen until use. For the assay of PRX in plasma, 500 μL PRX solution (10 μmol L-1 was added to 500 μL of untreated plasma and the mixture was vortexed for 30 s. In order to precipitate the plasma proteins, the plasma samples were treated with 250 μL perchloric acid (15%) and then, the mixture was centrifuged at 6000 rpm for 10 min. An appropriate volume of the supernatant liquor was transferred into the voltammetric cell containing phosphate solution of pH 5.0 and DPVs were recorded. The content of the PRX in the plasma was measured referring to the calibration graph or regression equation.

Results and Discussion

Physical characterization of the modified electrode

The SEM image provides useful approach to the determination of size, morphology and surface of the modified electrode. Figures 1a and 1b show the scanning electron micrographs of CPE and TiO2NPs/CPE, respectively. As can be seen on the surface of CPE, the layer of irregular flakes of graphite powder was present and isolated from each other. After addition of TiO2NPs to the carbon paste, it can be seen that the spherical form of TiO2NPs with ca. 20-30 nm diameter was completely distributed on the surface of the modified electrode, indicating that the TiO2NPs was successfully incorporated into the CPE (see Figure 1b).

Figure 1
Representation of field emission scanning electron micrographs of (a) CPE and (b) TiO2NPs/CPE.

Figure 2 shows the energy dispersive X-ray spectroscopy (EDS) and elemental analysis of TiO2NPs/CPE electrode surface. Observation of intensive peaks related to the electron transmissions of titanium, oxygen and carbon demonstrates the presence of TiO2NPs on the surface and between layers of graphite.

Figure 2
EDS spectrum of TiO2NPs/CPE surface.

Electrochemistry of fabricated electrodes

Potassium ferricyanide (K4Fe(CN)6) was selected as a probe to evaluate the performance of the fabricated bare CPE and TiO2NPs/CPE electrodes using cyclic voltammetry (CV) technique. Figure 3a illustrates the typical CVs of the electrochemical oxidation of K4Fe(CN)6 at the surface of the bare CPE and TiO2NPs/CPE electrodes in the 10 mmol L-1 of K4Fe(CN)6 and 0.1 mol L-1 of KCl solution. It is obvious that the electron transfer rate was sluggish, with a peak-to-peak separation (ΔEp) of 190 mV at the CPE.

Figure 3
(a) The CVs of bare CPE and TiO2NPs/CPE in the presence of 10 mmol L-1 K4Fe(CN)6 solution at a scan rate of 20 mV s-1 and pH of 7.0 in 0.1 mol L-1 KCl as supporting electrolyte; (b) plot of Ipa versus υ1/2 at the surface of bare CPE and TiO2NPs/CPE at various scan rates of 10, 25, 50, 75, 100, 150, 200, 250, 300, 350, 400, 450 and 500 mV s-1 for the oxidation of 1 mmol L-1 K4Fe(CN)6 in 0.1 mol L-1 KCl.

On the contrary, the TiO2NPs/CPE displayed a well-shaped cyclic response for the Fe(CN)63/Fe(CN)64- redox couple with a ΔEp of 110 mV, indicating a dramatic increase in the electron transfer rate due to the high conductivity of TiO2 nanoparticles. This is a quasi-reversible system because ΔEp is greater than 59 mV that is expected for a reversible system. Therefore, the TiO2 nanoparticles in CPE could facilitate the electron transfer rate between the electron surface and electroactive species. It is proposed that TiO2 nanoparticles present in the carbon paste electrode not only acted as a binder to fill in the blanks of the carbon paste, but also formed a layer of titanium dioxide nanoparticles on the electrode surface. This effect was previously reported for determination of carbamazepine in the pharmaceutical samples onto Ag/TiO2 nanocomposite modified carbon paste electrode.2424 Mashhadizadeh, M. H.; Refahati, R.; Amereh, E.; Anal. Bioanal. Electrochem. 2013, 5, 270. The obtained result from CV of TiO2NPs/CPE in various buffered solutions with different pH values does not show any shift in the anodic peak potentials for oxidation of K4Fe(CN)6 (data not shown). It can be concluded that the electrochemical behavior of the Fe(CN)63-/Fe(CN)64- redox couple in the TiO2NPs/CPE electrode is not dependent on the pH of solution.

The active surface areas of the fabricated electrodes were calculated by the CV method at various scan rates using K4Fe(CN)6 as a probe. For this approach, the Randles-Sevcik formula can be used:

(1) I pa = 0 . 4 4 6 3 AC 0 F 3 RT 1 2 n 3 2 D 1 2 υ 1 2

where Ipa (A) refers to the anodic peak current, A (cm2) is the active surface area of the electrode, C0 (mol cm-3) is the concentration of K4Fe(CN)6, F is the Faraday's constant (96485 C mol-1), R is the universal gas constant (8.314 J mol-1 K-1), T is the absolute temperature (298 K), n is the electron transfer number, D (cm2 s-1) is the diffusion coefficient and υ (V s-1) is the scan rate. For 1.0 mmol L-1 K4Fe(CN)6 in 0.1 mol L-1 KCl as supporting electrolyte, the amount of n and D is 1 and 7.6 × 10-6 cm2 s-1, respectively.2525 Gharibi, H.; Kakaei, K.; Zhiani, M.; J. Phys. Chem. C 2010, 114, 5233.,2626 Hassaninejad-Darzi, S. K.; Rahimnejad, M.; J. Iran. Chem. Soc. 2014, 11, 1047. Figure 3b illustrates the plot of Ipa versus υ1/2 for the oxidation of K4Fe(CN)6 on the surface of bare CPE and TiO2NPs/CPE at various scan rates. Linear relationship between the anodic or cathodic peak currents and υ1/2 indicates a diffusion control process at the surfaces of both electrodes. In this experiment, the slopes Ipa versus υ1/2 were 61.50 and 242.49 μA (V-1 s-1)1/2 for bare CPE and TiO2NPs/CPE, respectively. Therefore, the active microscopic surface areas were found to be 0.084 and 0.390 cm2 for the bare CPE and TiO2NPs/CPE, respectively. These results indicated that modification of CPE with the TiO2 nanoparticles causes an increase in the active surface area of the modified electrode.

Electrochemical behavior of PRX at TiO2NPs/CPE and bare CPE

Inset in Figure 4 shows cyclic voltammograms of bare CPE and TiO2NPs/CPE in the absence of PRX in the phosphate solution of pH 5.0 at the potential range from 0.0 to 1.4 V vs. Ag|AgCl|KCl (3 mol L-1) and potential sweep rate of 25 mV s-1. As can be seen, no current can be obtained with these electrodes. Figure 4 displays the cyclic voltammograms of 0.3 mmol L-1 PRX at bare CPE and TiO2NPs/CPE in the phosphate solution of pH 5.0 at the potential range from 0.0 to 1.4 V vs. Ag|AgCl|KCl (3 mol L-1) and potential sweep rate of 25 mV s-1. The PRX exhibited a well-defined irreversible anodic peak at both TiO2NPs/CPE and bare CPE. The anodic voltammetric signals can be ascribed to the oxidation of -NH group.2727 Jain, R.; Tiwarib, D. C.; Shrivastava, S.; Mater. Sci. Eng. B 2014, 185, 53. The electroanalytical performance of TiO2NPs/CPE was advantageous over that observed at the bare CPE. The cyclic voltammograms of PRX showed about 2.5 times enhancement in the oxidation peak current at TiO2NPs/CPE (165 μA) as compared to a bare CPE (65 μA). The higher electrocatalytic behavior of the modified electrode corresponds to the presence of a larger number of electrochemical active sites and decrease in the charge transfer resistance in the TiO2NPs/CPE rather than in the bare CPE. These results indicated that the electrochemical oxidation of PRX has higher electron transfer kinetics in the surface of modified electrode, therefore, somewhat improving the sensitivity for voltammetric measurement.

Figure 4
The cyclic voltammograms of 0.3 mmol L-1 PRX at the surface of (a) bare CPE and (b) TiO2NPs/CPE in the phosphate solution of pH 5.0 and scan rate of 25 mV s-1. Inset shows CVs of modified electrodes in the phosphate solution of pH 5.0.

Effect of pH

The influence of pH on the electrooxidation of 0.3 mmol L-1 PRX at TiO2NPs/CPE was investigated in the pH range of 2.0-13.0 (see Figure 5a). Optimum peak current was achieved at pH 5, therefore, a phosphate solution of pH 5.0 was used for subsequent work. It is seen that increasing the pH, the peak current decreases due to pH dependence of half wave potential, which indicates the involvement of protons in the electrode process and finally dislocated in alkaline pH due to a lower number of available protons.2727 Jain, R.; Tiwarib, D. C.; Shrivastava, S.; Mater. Sci. Eng. B 2014, 185, 53. It can be seen from Figure 5b that with increase in pH of the solution, the oxidation current was observed to be shifted towards lower potentials.

Figure 5
The effect of pH on the (a) peak current and (b) peak potential of 0.3 mol L-1 PRX at TiO2NPs/CPE and scan rate of 25 mV s-1.

The linear dependence of peak potential on the pH in the range of 2.0-13.0 can be expressed by the following equation: Ep(V) = -0.0645pH + 1.1706. A slope value of 0.0645V / pH is close to the expected slope of 0.059V / pH, which indicates that the number of electrons and protons participating in the oxidation of PRX is the same.2828 Jain, R.; Sharma, R.; Yadav, R. K.; Shrivastava, R.; J. Electrochem. Soc. 2013, 160, 179.

Effect of potential sweep rate

Useful information with regard to electrochemical mechanisms can be obtained from the relationship between the peak current and the sweep rate. Therefore, the cyclic voltammetric investigations of PRX (0.3 mmol L-1) were performed on the surface of TiO2NPs/CPE at different sweep rates in the phosphate solution of pH 5.0. The PRX at the surface of TiO2NPs/CPE exhibits a single well defined oxidation peak at 0.9 V vs. Ag|AgCl|KCl (3 mol L-1). Since no anodic peak was observed in the reverse scan, therefore, the nature of the electrode process is irreversible. Figure 6a illustrates the influence of the sweep rate on the oxidation current of PRX in the range of 20-450 mV s-1. From Figure 6b, it can be seen that there is no linear relationship between peak current and scan rate; meanwhile, a linear relationship between anodic peak current (Ipa) vs. square root of scan rate (υ1/2) was obtained (see Figure 6c), suggesting the diffusion of PRX at the surface of TiO2NPs/CPE, which can be expressed by the following expression:2929 Engin, C.; Yilmaz, S.; Saglikoglu, G.; Yagmur, S.; Sadikoglu, M.; Int. J. Electrochem. Sci. 2015, 10, 1916.,3030 Madrakian, T.; Haghshenas, E.; Afkhami, A.; Sens. Actuators, B 2014, 193, 451. Ipa(μA) = 12.492υ1/2(mV s-1) + 91.051, R2 = 0.998.

Figure 6
(a) The CVs of 5 mmol L-1 PRX at the TiO2NPs/CPE in the phosphate solution (pH 5.0) at various scan rates from inner to outer: 20, 40, 75, 150, 250, 300, 350 and 450 mV s-1; (b) plot of Ipa and υ; (c) plot of Ipa and υ1/2; (d) plot of log Ipa vs. log υ; (e) plot of Epa vs. υ and (f) plot of Epa vs. log υ for CVs showed in the (a).

From theoretical point, a slope of 0.5 or 1.0 is expected for the plot of log Ipa vs. log υ under diffusion or adsorption control, respectively.3131 Azizi, S. N.; Ghasemi, S.; Chiani, E.; Electrochim. Acta 2013, 88, 463. A linear dependence is observed between log Ipa and log υ at the surface of TiO2NPs/CPE in the PRX oxidation (see Figure 6d). From linear section, the slope of 0.2922 is found that is near to the theoretically predicted value of 0.5 for a purely diffusion-controlled current. However, the contribution of a kinetic limitation to the overall process causes a small alteration in the theoretical value.3131 Azizi, S. N.; Ghasemi, S.; Chiani, E.; Electrochim. Acta 2013, 88, 463.,3232 Fleischmann, M.; Korinek, K.; Pletcher, D.; J. Electroanal. Chem. Interfacial Electrochem. 1971, 31, 39.

The electrochemical kinetic parameters, the number of electrons transferred (n), electron transfer coefficient (α) and the rate of the reaction, were evaluated by subjecting the scan rate results to the Laviron equation:3333 Laviron, E.; J. Electroanal. Chem. 1979, 101, 19.

(2) E pa = E 0 RT α nF 1 n RTk s α nF + RT α nF 1 n υ

where E0 is the formal potential, n is the number of electrons transferred, α is the electron transfer coefficient and ks is the standard rate constant of the electrode reaction. For the irreversible oxidation reaction, the values of ks and αn were deduced from the intercept and the slope of the linear plot of Epa vs. log υ, when the value of E0 was known.3434 Narayana, P. S.; Teradal, N. L.; Seetharamappa, J.; Satpati, A. K.; Anal. Methods 2015, 7, 3912. The value of E0 for PRX at the surface of TiO2NPs/CPE was obtained from the intercept of the plot of Epa vs. υ, as shown in Figure 6e (E0 = 1.1714 V). Knowing the values of E0, the slope and the intercept of the plot of Epa vs. log υ (Figure 6f), the values of αn and ks were calculated to be 0.943 and 2.025 s-1, respectively. Since, for a totally irreversible electron transfer reaction, α was assumed to be 0.5, the value of n was calculated to be 1.886. This indicated that two electrons have taken part in the irreversible oxidation step.3535 Teixeira, J. G.; Veiga, A.; Carvalho, A. J. P.; Teixeira, D. M.; Electrochim. Acta 2013, 108, 51. Also, the large value of electron transfer rate constant indicates the strong ability of the TiO2NPs/CPE to promote electron transfer between PRX and the electrode surface.

Electrooxidation mechanism of PRX

Based on information obtained from cyclic voltammetry, the effect of pH and scan rate and also other studies made previously on voltammetric determination of PRX and electrochemical oxidation of amines,3636 Cheemalapati, S.; Karuppiah, C.; Chen, S. M.; Ionics 2014, 20, 1599.

37 Thirumoorthi, A.; Elango, K. P.; J. Chem. Sci. 2007, 119, 289.

38 Adams, R. N.; Electrochemistry at Solid Electrodes. Monographs in Electroanalytical Chemistry and Electrochemistry; Marcel Dekker: New York, 1969.
-3939 Haouas, K. B.; Tapsoba, I.; Benkhoud, M. L.; Boujlel, K.; J. Electroanal. Chem. 2004, 571, 241. the electrooxidation process of PRX at the modified electrode surface is proposed as the reaction shown in Scheme 2.

Scheme 2
Electrooxidation mechanism of PRX.

Chronoamperometric studies

Chronoamperometric measurements of PRX at the surface of TiO2NPs/CPE were carried out by setting the working electrode potential at 0.9 V vs. Ag|AgCl|KCl (3 mol L-1) for various concentrations of PRX in the phosphate solution (pH 5.0), as presented in Figure 7A. For an electroactive material (i.e., PRX in this case) with a diffusion coefficient, D, the current observed for the electrochemical reaction under mass transport-limited conditions can be described by the Cottrell equation:4040 Taraszewska, J.; Rosłonek, G.; J. Electroanal. Chem. 1994, 364, 209.,4141 Greef, R.; Peat, R.; Peter, L. M.; Pletcher, D.; Robinson, J.; Instrumental Methods in Electrochemistry; Ellis Horwood: Chichester, 1990.

(3) I = nFACD 1 2 π 1 2 t 1 2

where n is the number of electron (i.e., 2), F is the Faraday number (96485 C mol-1), A is the area of the electrode (0.0962 cm2), C is the known concentration of PRX and D is the diffusion coefficient. Experimental plots of I vs. t-1/2 were drawn and the best fits for different concentrations of PRX were determined (Figure 7B). The slopes of the resulting straight lines were then plotted vs. PRX concentration (Figure 7C). From the resulting slope and Cottrell equation, the mean value of D was found to be 3.92 × 10-7 cm2 s-1.

Figure 7
(A) Chronoamperograms obtained at TiO2NPs/CPE in the phosphate solution (pH 5.0) for PRX concentrations of (a) 0.0; (b) 0.3; (c) 0.4; (d) 0.5 and (e) 0.6 mmol L-1; (B) plots of I vs. t-1/2 obtained from chronoamperograms (a)-(e) in (A); (C) plot of the slope of the straight lines against PRX concentration; (D) dependence of Icat / Il on t1/2 derived from the data in chronoamperogram (a)-(e) in (A).

Chronoamperometry can also be used to evaluate the catalytic rate constant, kcat, for the reaction between PRX and TiO2NPs/CPE according to the method of Galus:4242 Luo, H.; Shi, Z.; Li, N.; Gu, Z.; Zhuang, Q.; Anal. Chem. 2001, 73, 915.

(4) I c / I L = γ 1 / 2 π 1 / 2 erf γ 1 / 2 + exp γ / γ 1 / 2

where IC is the catalytic current of PRX at TiO2NPs/CPE, IL is the limited current in the absence of PRX, and γ = kcatCbt is the argument of the error function (Cb is the bulk concentration of PRX). When γ exceeds 2, the error function is almost equal to 1, so equation 4 can be reduced to:

(5) I C / I L = π 1 / 2 γ 1 / 2 = π 1 / 2 ( k cat C b t ) 1 / 2

where t is the elapsed time. Equation 5 can be used to estimate kcat for the catalytic process from the slope of IC / IL vs. t1/2 at a given PRX concentration (Figure 7D). The average value of kcat was calculated to be 12.64 cm3 mol-1 s-1.

Analytical applications

Calibration curve

In order to develop an electroanalytical method for the PRX determination, we have selected the DPV method. The phosphate solution of pH 5.0 was selected as the supporting electrolyte for the quantification of PRX as it gave maximum peak current. The DPV measurement conditions were optimized by monitoring the variation in peak current with pulse amplitude, pulse width and sweep rate. The quantitative determination of PRX was based on the dependence of oxidation peak current on the PRX concentration. The differential pulse voltammograms of PRX at different concentrations is shown in Figure 8a. Under the optimized conditions (sweep rate: 25 mV s-1, pulse amplitude: 50 mV, pulse width: 50 ms), a linear relation between the peak current and PRX concentration was observed in the range of 0.46-100 μM. Deviation from the linearity was observed above this concentration level perhaps due to the adsorption of oxidation product of PRX on the surface of TiO2NPs/CPE. The dependence of oxidation peak current vs. the concentration of PRX at the surface of TiO2NPs/CPE is shown in Figure 8b. The value of F for regression obtained was 989.2. The F value is used to test the null hypothesis that the total variance in y (i.e., oxidation peak current) is equal to the variance due to error. A value of F greater than the value from the tables at the chosen confidence level indicates that the null hypothesis should be rejected and that the regression is significant. This result is in agreement with the obtained R2 of regression model (i.e., R2 = 0.994).

Figure 8
(a) DPVs of PRX at TiO2NPs/CPE in the phosphate solution of pH 5.0 at different concentrations from inner to outer: 0.6, 13, 21, 35, 50, 65, 85 and 100 μmol L-1; (b) calibration plot of PRX.

The limit of detection (LOD) and limit of quantification (LOQ) were estimated by the following equations:2727 Jain, R.; Tiwarib, D. C.; Shrivastava, S.; Mater. Sci. Eng. B 2014, 185, 53.

(6) LOD = 3 S . D . / m
(7) LOQ = 1 0 S . D . / m

where S.D. is the standard deviation of the intercept and m is the slope of the calibration curve. The LOD and LOQ were calculated to be 0.14 and 0.46 μmol L-1, respectively. The calibration curve was linear in the concentration lower than 100 μmol L-1. Then, linear dynamic range (LDR) obtained was 0.46-100 μmol L-1.

Effect of interferences

The effects of some biological interferences have been investigated on the electrochemical oxidation of PRX. This was performed by recording the DPVs of 10 μM PRX at TiO2NPs/CPE for 5 times with varying amounts of each of the interfering substance (5-100 μmol L-1). For each voltammetric measurement (in the absence and presence of interferences), freshly modified electrode was used to obtain the reproducible results. The corresponding results are given in Table 1. The experimental results show that modified electrode yield a small change response for the interfering agents. It confirms that TiO2NPs/CPE can be considered as a good electrochemical sensor for recognition of PRX.

Table 1
The effects of interferences on the DPV response of 10 μM PRX at TiO2NPs/CPE

Determination of PRX in the pharmaceutical tablets and spiked plasma samples

The TiO2NPs/CPE was directly used to determine the content of PRX in 0.35 and 0.7 mg tablets. Ten tablets were weighed and grounded to an homogeneous fine powder in a mortar. The powder was then transferred in 100 mL distilled water by ultrasonication. Then, different adequate amount of prepared solutions was diluted to 10 mL with the phosphate solution (pH 5.0) and transferred to the voltammetric cell for the voltammetric determinations. The results listed in Table 2 agreed satisfactorily with the labeled content of PRX. Low values of the relative standard deviation (RSD, 2.24%) indicated good reproducibility of the results.

Table 2
Determination results of PRX in the commercial tablets (n = 5); ttab (95%) = 2.78

The applicability of the proposed method was examined by analyzing PRX in plasma samples employing the TiO2NPs/CPE. Serum samples were spiked with known amounts of PRX and analyzed by recording DPVs. The amount of PRX in human serum samples was determined by referring to the calibration pot. The obtained results in Table 3 indicated good recovery of PRX.

Table 3
Results for determination of PRX in spiked human serum samples (n = 5) by proposed sensor; ttab (95%) = 2.78

Repeatability, stability and reproducibility of the modified electrode

The repeatability of the TiO2NPs/CPE was investigated by repetitive recording at a fixed PRX concentration of 0.3 mM. The RSD for the peak currents in CVs based on five replicates was 2.7%, indicating excellent repeatability of the modified electrode response. Also, using the TiO2NPs/CPE daily and storing under ambient conditions over a period of 40 days, the electrode retained 97.3% of its initial peak current response for a PRX concentration of 0.3 mmol L-1, which shows long-term stability of the modified electrode. Also, the fabrication reproducibility was evaluated by preparing five modified electrodes independently. The RSD for peak current determinations with five prepared electrodes on 0.3 mmol L-1 PRX was calculated to be 3.4%. The repeatability and stability of TiO2NPs/CPE were also examined by DPV measurements of 20.0 μmol L-1 PRX. The RSD for five successive assays was 1.8%. When using five different TiO2NPs/CPE, the RSD% for five measurements (for each one) was 2.8%. When the electrode was stored in the laboratory, the modified electrode retains 97.5% of its initial response after a week and 95% after 30 days. The results indicate that the modified electrode has a good repeatability and reproducibility in both preparation procedure and voltammetric determinations with good long-term stability. So far, few studies have been reported for electrochemical determination of PRX. The results of this work were compared with other previous work2727 Jain, R.; Tiwarib, D. C.; Shrivastava, S.; Mater. Sci. Eng. B 2014, 185, 53.,2828 Jain, R.; Sharma, R.; Yadav, R. K.; Shrivastava, R.; J. Electrochem. Soc. 2013, 160, 179.,3434 Narayana, P. S.; Teradal, N. L.; Seetharamappa, J.; Satpati, A. K.; Anal. Methods 2015, 7, 3912.,3636 Cheemalapati, S.; Karuppiah, C.; Chen, S. M.; Ionics 2014, 20, 1599. and are shown in Table 4.

Table 4
Comparison of the analytical performance of TiO2NPs modified carbon paste electrode (present work) with previously reported electrochemical methods

Conclusions

In the present study, electrochemical determination of pramipexole was studied using modified carbon paste electrode with TiO2 nanoparticles (TiO2NPs/CPE) via CV, DPV and chronoamperometry techniques. The developed methodology of this study was simple, fast, sensitive and cheap, especially in comparison with sophisticated techniques such as chromatography. The fabricated sensor identified PRX in the linear range of 0.46-100 μmol L-1 by DPV technique. The proposed electrochemical sensor was well selective for PRX in the presence of common interferences. Furthermore, it shows good reproducibility and repeatability. Besides, the modified electrode has been applied successfully for the determination of PRX in the pharmaceutical tablets and spiked plasma samples.

Acknowledgments

This work was supported by the Babol University of Technology (Islamic Republic of Iran). Also, we are very thankful to PhD Afshin Sarvari for the proposal of PRX electrooxidation mechanism.

References

  • 1
    Leentjens, A. F. G.; Drugs 2011, 71, 273.
  • 2
    Lavudu. P.; Rani, A. P.; Sekaran, C. B.; Kumar, K. S.; Ramesh, A.; Chem. Sci. J. 2012, 3, 1.
  • 3
    Leentjens, F. G.; Koester, J.; Fruh, B.; Toby, D.; Shephard, S.; Barone, P.; Houben, J. G.; Clin. Ther. 2009, 31, 89.
  • 4
    Srinu, B. G.; Raju, C.; Asian J. Chem. 2007, 19, 816.
  • 5
    Lau, Y. Y.; Hanson, G. D.; Ichhpurani, N.; J. Chromatogr. B 1996, 683, 217.
  • 6
    Lau, Y. Y.; Selenka, J. M.; Hanson, G. D.; Talat, R.; Ichhpurani, N.; J. Chromatogr. B 1996, 683, 209.
  • 7
    Pathare, D. B.; Jadhav, A. S.; Shingare, M. S.; J. Pharm. Biomed. Anal. 2006, 41, 1152.
  • 8
    Gurupadayya, B. M.; Vishwajith, V.; Srujana, N.; World J. Chem. 2009, 4, 157.
  • 9
    Jayesh, G. P.; Ravindra, V. P.; Shobhana, K. M.; Biomed. Chromatogr. 2011, 25, 524.
  • 10
    Shubhangi, M. P.; Sunil, R. D.; J. Liq. Chromatogr. Relat. Technol. 2011, 34, 1664.
  • 11
    Alessandro, M.; Ernst, K.; Emanuele, M.; Anal. Chim. Acta 2008, 626, 89.
  • 12
    Aref, M. A.; Raoof, J. B.; Ojani, R.; Colloids Surf. B 2013, 109, 287.
  • 13
    Raoof, J. B.; Ojani, R.; Baghayeri, M.; Aref, M. A.; Anal. Methods 2012, 4, 157.
  • 14
    Lin, X.; Li, Y.; Biosens. Bioelectron. 2006, 22, 253.
  • 15
    Ghavami, R.; Salimi, A.; Navaee, A.; Biosens. Bioelectron. 2011, 26, 3864.
  • 16
    O'Regan, B.; Gratzel, M.; Nature 1991, 353, 737.
  • 17
    Macak, J. M.; Barczuk, P. J.; Tsuchiya, H.; Nowakowska, G. A.; Chojak, M.; Bauer, S.; Virtanen, S.; Kulesza P. J.; Schmuki, P.; Electrochem. Commun. 2005, 7, 1417.
  • 18
    Qingwen, L.; Yiming, W.; Guoan, L.; Mater. Sci. Eng. C 2000, 11, 71.
  • 19
    Li, G.; Qu, J.; Zhang, X.; Ge, J.; Water Res. 2006, 40, 213.
  • 20
    Lo, P. H.; Kumar, S. A.; Chen, S. M.; Colloids Surf. B 2008, 66, 266.
  • 21
    Raoof, J. B.; Ojani, R.; Baghayeri, M.; Chin. J. Catal. 2011, 32, 1685.
  • 22
    Lunsford, S. K.; Choi, H.; Stinson, J.; Yeary, A.; Dionysiou, D. D.; Talanta 2007, 73, 172.
  • 23
    Mashhadizadeh, M. H.; Afshar, E.; Electrochim. Acta 2013, 87, 816.
  • 24
    Mashhadizadeh, M. H.; Refahati, R.; Amereh, E.; Anal. Bioanal. Electrochem. 2013, 5, 270.
  • 25
    Gharibi, H.; Kakaei, K.; Zhiani, M.; J. Phys. Chem. C 2010, 114, 5233.
  • 26
    Hassaninejad-Darzi, S. K.; Rahimnejad, M.; J. Iran. Chem. Soc. 2014, 11, 1047.
  • 27
    Jain, R.; Tiwarib, D. C.; Shrivastava, S.; Mater. Sci. Eng. B 2014, 185, 53.
  • 28
    Jain, R.; Sharma, R.; Yadav, R. K.; Shrivastava, R.; J. Electrochem. Soc. 2013, 160, 179.
  • 29
    Engin, C.; Yilmaz, S.; Saglikoglu, G.; Yagmur, S.; Sadikoglu, M.; Int. J. Electrochem. Sci. 2015, 10, 1916.
  • 30
    Madrakian, T.; Haghshenas, E.; Afkhami, A.; Sens. Actuators, B 2014, 193, 451.
  • 31
    Azizi, S. N.; Ghasemi, S.; Chiani, E.; Electrochim. Acta 2013, 88, 463.
  • 32
    Fleischmann, M.; Korinek, K.; Pletcher, D.; J. Electroanal. Chem. Interfacial Electrochem. 1971, 31, 39.
  • 33
    Laviron, E.; J. Electroanal. Chem. 1979, 101, 19.
  • 34
    Narayana, P. S.; Teradal, N. L.; Seetharamappa, J.; Satpati, A. K.; Anal. Methods 2015, 7, 3912.
  • 35
    Teixeira, J. G.; Veiga, A.; Carvalho, A. J. P.; Teixeira, D. M.; Electrochim. Acta 2013, 108, 51.
  • 36
    Cheemalapati, S.; Karuppiah, C.; Chen, S. M.; Ionics 2014, 20, 1599.
  • 37
    Thirumoorthi, A.; Elango, K. P.; J. Chem. Sci. 2007, 119, 289.
  • 38
    Adams, R. N.; Electrochemistry at Solid Electrodes. Monographs in Electroanalytical Chemistry and Electrochemistry; Marcel Dekker: New York, 1969.
  • 39
    Haouas, K. B.; Tapsoba, I.; Benkhoud, M. L.; Boujlel, K.; J. Electroanal. Chem. 2004, 571, 241.
  • 40
    Taraszewska, J.; Rosłonek, G.; J. Electroanal. Chem. 1994, 364, 209.
  • 41
    Greef, R.; Peat, R.; Peter, L. M.; Pletcher, D.; Robinson, J.; Instrumental Methods in Electrochemistry; Ellis Horwood: Chichester, 1990.
  • 42
    Luo, H.; Shi, Z.; Li, N.; Gu, Z.; Zhuang, Q.; Anal. Chem. 2001, 73, 915.
  • 43
    Alessandro, M.; Ernst, K.; Emanuele M.; Anal. Chim. Acta 2008, 626, 89.
  • 44
    Lau, Y. Y.; Hanson, G. D.; Ichhpurani, N.; J. Chromatogr. B 1996, 683, 217.
  • 45
    Lavudu, P.; Rani, A. P.; Sekaran, C. B.; Kumar, K. S.; Ramesh, A.; Chem. Sci. J. 2012, 2012, CSJ49.

Publication Dates

  • Publication in this collection
    Apr 2017

History

  • Received
    11 Feb 2016
  • Accepted
    28 June 2016
Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
E-mail: office@jbcs.sbq.org.br