Ion Exchange Chromatography and Mass Bias Correction for Accurate and Precise Zn Isotope Ratio Measurements in Environmental Reference Materials by MC-ICP-MS

Abstract

Precise and accurate d66/64Zn data for environmental reference materials (RMs) including rocks, sediments, soils and plants are presented in order to improve the metrological traceability and analytical control of Zn isotope ratio determinations in future environmental studies. Previously developed ion exchange chromatography protocols were adjusted to enable faster sample throughput and instrumental mass bias processes were investigated. The improved chromatographic protocol yielded precise and quantitative recoveries (99 ± 7%, σ, n = 16), while the mass bias correction using Cu as external dopant provided precisions better than 0.02‰, 2σ, n = 7. Investigations into spectral and non-spectral interferences identified significant formation of Cr and Ti oxides and hydroxide ionic species. Analysis of six RMs (BHVO-2 basalt (USGS), BCR-2 basalt (USGS), AGV-2 andesite (USGS), 2709 San Joaquin soil (NIST), 1646a estuarine sediment (NIST) and 1573a tomato leaves (NIST)) showed good reproducibility (< 0.01‰, 2s, 5 ≤ n ≥ 1).

Keywords:
analytical geochemistry; Zn isotopes; isotope geochemistry; mass spectrometry; metal isotopes


Introduction

The advent of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) promoted the development of new research areas in the isotope geosciences, in particular the stable isotope biogeochemistry of transition metals such as Cu, Zn, Fe and others.11 Wiederhold, J.; Environ. Sci. Technol. 2015, 49, 2606.

2 Bullen, T. In Handbook of Environmental Isotope Geochemistry; Baskaran, M., ed.; Springer: Heidelberg, Germany, 2011.
-33 Weiss, D.; Rehkdmper, M.; Schoenberg, R.; McLaughlin, M.; Kirby, J.; Campbell, P.; Arnold, T.; Chapman, J.; Peel, K.; Gioia, S.; Environ. Sci. Technol. 2008, 42, 655. Recent studies have shown the great potential of stable metal isotopes to identify contaminant sources,44 Yin, N.; Sivry, Y.; Benedetti, M.; Lens, P.; van Hullebusch, E.; Appl. Geochem. 2016, 64, 128.,55 Sonke, J.; Sivry, Y.; Viers, J.; Freydier, R.; Dejonghe, L.; Andre, L.; Aggarwal, J.; Fontan, F.; Dupre, B.; Chem. Geol. 2008, 252, 145. to constrain biogeochemical processes during nutrient cycling,66 Peel, K.; Weiss, D.; Siggc, L.; Limnol. Oceanogr. 2009, 54, 1699. weathering77 Viers, J.; Oliva, P.; Nonell, A.; Gelabert, A.; Sonke, J.; Freydier, R.; Gainville, R.; Dupre, B.; Chem. Geol. 2007, 239, 124.,88 Mulholland, D.; Poitrasson, F.; Boaventura, G.; Allard, T.; Vieira, L.; Santos, R.; Mancini, L.; Seyler, P.; Geochim. Cosmochim. Acta 2015, 150, 142. and to reconstruct metal transfer processes in complex systems such as the human body.99 Jaouen, K.; Pons, M.; Balter, V.; Earth Planet. Sci. Lett. 2013, 374, 164.,1010 Larner, F.; Woodley, L.; Shousha, S.; Moyes, A.; Humphreys-Williams, E.; Strekopytov, S.; Halliday, A.; Rehkämper, M.; Coombes, R.; Metallomics 2015, 7, 112. Special attention has been given to Zn due to its key function as micronutrient in the biosphere and as pollutant in industrial, mining and urban environments.11 Wiederhold, J.; Environ. Sci. Technol. 2015, 49, 2606.

2 Bullen, T. In Handbook of Environmental Isotope Geochemistry; Baskaran, M., ed.; Springer: Heidelberg, Germany, 2011.
-33 Weiss, D.; Rehkdmper, M.; Schoenberg, R.; McLaughlin, M.; Kirby, J.; Campbell, P.; Arnold, T.; Chapman, J.; Peel, K.; Gioia, S.; Environ. Sci. Technol. 2008, 42, 655.,1111 Cloquet, C.; Carignan, J.; Lehmann, M.; Vanhaecke, F.; Anal. Bioanal. Chem. 2008, 392, 451.

The natural variations in the Zn isotopic composition are small (< 1‰), requiring reliable analytical procedures including chromatographic separation of Zn from the matrix1212 Maréchal, C.; Télouk, P.; Albaréde, F.; Chem. Geol. 1999, 156, 251.

13 Chapman, J.; Mason, T.; Weiss, D.; Coles, B.; Wilkinson, J.; Geostand. Geoanal. Res. 2006, 30, 5.
-1414 Sossi, P.; Halverson, G.; Nebel, O.; Eggins, S.; Geostand. Geoanal. Res. 2014, 39, 129. and accurate correction of the instrumental mass bias.1414 Sossi, P.; Halverson, G.; Nebel, O.; Eggins, S.; Geostand. Geoanal. Res. 2014, 39, 129.

15 Peel, K.; Weiss, D.; Chapman, J.; Arnold, T.; Coles, B.; J. Anal. At. Spectrom. 2008, 23, 103.
-1616 Irrgeher, J.; Prohaska, T.; Anal. Bioanal. Chem. 2015, 408, 23 369. To date, a number of ion exchange chromatographic protocols for specific sample types such as rocks, sediments, marine and fresh water, aerosols, plants and food has been published.1717 Sivry, Y.; Riotte, J.; Sonke, J.; Audry, S.; Schafer, J.; Viers, J.; Blanc, G.; Freydier, R.; Dupre, B.; Chem. Geol. 2008, 255, 295.

18 Thapalia, A.; Borrok, D.; Van Metre, P.; Musgrove, M.; Landa, E.; Environ. Sci. Technol. 2010, 44, 1544.

19 Petit, J.; de Jong, J.; Chou, L.; Mattielli, N.; Geostand. Geoanal. Res. 2008, 32, 149.

20 Weiss, D.; Rausch, N.; Mason, T.; Coles, B.; Wilkinson, J.; Ukonmaanaho, L.; Arnold, T.; Nieminen, T.; Geochim. Cosmochim. Acta 2007, 71, 3498.

21 Conway, T.; Rosenberg, A.; Adkins, J.; John, S.; Anal. Chim. Acta 2013, 793, 44.

22 Chen, J.; Gaillardet, J.; Louvat, P.; Huon, S.; Geochim. Cosmochim. Acta 2009, 73, 4060.

23 Chen, J.; Louvat, P.; Gaillardet, J.; Birck, J.; Chem. Geol. 2009, 259, 120.

24 Gioia, S.; Weiss, D.; Coles, B.; Arnold, T.; Babinski, M.; Anal. Chem. 2008, 80, 9776.

25 Arnold, T.; Schönbächler, M.; Rehkämper, M.; Dong, S.; Zhao, F.; Kirk, G.; Coles, B.; Weiss, D.; Anal. Bioanal. Chem. 2010, 398, 3115.
-2626 Costas-Rodríguez, M.; Van Heghe, L.; Vanhaecke, F.; Metallomics 2014, 6, 139. Moreover, our understanding about instrumental controls of mass bias including effect of acid strength, dopant/analyte ratios, wet and dry plasma and matrix has improved.2727 Moeller, K.; Schoenberg, R.; Pedersen, R.; Weiss, D.; Dong, S.; Geostand. Geoanal. Res. 2012, 36, 177.

28 Zhu, Z.; Jiang, S.; Yang, T.; Wei, H.; Int. J. Mass Spectrom. 2015, 393, 34.

29 Albarède, F.; Beard, B. L. In Geochemistry of Non-Traditional Stable Isotopes; Johnson, C. M.; Beard, B. L.; Albarède, F., eds.; Mineralogical Society of America: Washington, USA, 2004, ch. 4.

30 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 209.

31 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 218.
-3232 Archer, C.; Vance, D.; J. Anal. At. Spectrom. 2004, 19, 656. However, the rapid advance of the stable metal isotope field has not been accompanied by the supply of reference materials (RMs), hindering the inter-laboratory studies and quality assurances.1616 Irrgeher, J.; Prohaska, T.; Anal. Bioanal. Chem. 2015, 408, 23 369. For Zn isotopic compositions, only two certified isotopic reference materials (iCRMs) are available commercially, supplied by the Institute for Reference Materials and Measurements (IRMM-651 and IRMM-3702).1616 Irrgeher, J.; Prohaska, T.; Anal. Bioanal. Chem. 2015, 408, 23 369.,3333 Vogl, J.; Pritzkow, W. In Isotopic Analysis: Fundamentals and Applications Using ICP-MS; Vanhaecke, F.; Degryse, P., eds.; Wiley-VCH Verlag GmbH & Co. KGaA: Weinheim, Germany, 2012, p. 139. These two iCRMs are synthetic solutions whose matrices do not match with environmental and geological samples, hence they are not suitable for sample preparation and effect matrix control.1616 Irrgeher, J.; Prohaska, T.; Anal. Bioanal. Chem. 2015, 408, 23 369.

To address this problem, many laboratories have analyzed certified reference materials for elemental concentrations.3434 de Laeter, J. R.; Geostand. Geoanal. Res. 2005, 29, 53. To date, the most available Zn isotopic data have been provided for silicate rocks such as the RMs BHVO-2 basalt, BCR-2 basalt and AGV-2 andesite.2727 Moeller, K.; Schoenberg, R.; Pedersen, R.; Weiss, D.; Dong, S.; Geostand. Geoanal. Res. 2012, 36, 177. Data for RMs with environmental matrices such as soils, plants and sediments are rarely published, such that only one environmental RM (BCR-281 rye grass)2020 Weiss, D.; Rausch, N.; Mason, T.; Coles, B.; Wilkinson, J.; Ukonmaanaho, L.; Arnold, T.; Nieminen, T.; Geochim. Cosmochim. Acta 2007, 71, 3498. was reported in a data compilation from different laboratories (see Table 1 from reference 11).

Table 1
Original protocol of Maréchal et al.1212 Maréchal, C.; Télouk, P.; Albaréde, F.; Chem. Geol. 1999, 156, 251. and the modified protocol used in this study

Thus, the improvement of metrological traceability, data quality control and methodological validation for the production of reliable and comparable data on metal isotopes analysis is of the utmost urgency.1212 Maréchal, C.; Télouk, P.; Albaréde, F.; Chem. Geol. 1999, 156, 251.,3434 de Laeter, J. R.; Geostand. Geoanal. Res. 2005, 29, 53.

To address this gap, a method was set up for accurate and precise Zn isotopic measurements in environmental reference materials in two Brazilian laboratories (Laboratório de Geocrologia at University of Brasília (UnB) and Centro de Pesquisas Geocronológicas (CPGeo) at University of São Paulo (USP)). To this end, (i) a fast and simple chromatographic separation for Zn was introduced and calibrated; (ii) mass bias effects related to the analyte-dopant ratios (Zn/Cu) were assessed critically; (iii) effects of spectral and non-spectral interferences on Zn isotopic compositions were quantified; and (iv) new isotopic values for RMs of soils, sediments and plant matrices (2709 San Joaquin soil, 1646a estuarine sediment and 1573a tomato leaves) extending the data base for δ66/64Zn in materials relevant for environmental studies were determined. The database for previously analyzed RMs like the BHVO-2 basalt, BCR-2 basalt and AGV-2 andesite was further expanded.

Experimental

Reagents, standards and reference materials

The work was carried out under clean laboratory conditions in class 100 fume hoods, utilizing only Savillex® PFA labware. Ultrapure acids (Merck®) distilled by sub-boiling in Teflon® stills, Merck Suprapur H2O2 (30%) and de-ionized water (Milli-Q, 18.2 MΩ cm) were used. Multielement standard solutions (Merck®) were used to produce calibration curves to measure Cu, Zn, Na, Fe, Al, Ca, Mg, Ti, Cr and K by inductively coupled plasma optical emission spectrometer (ICP OES) and quadrupole inductively coupled plasma mass spectrometry (Q ICP-MS).

The reference materials BHVO-2 basalt (US Geochemical Reference Materials and Certificates (USGS)), BCR-2 basalt (USGS) and the AGV-2 andesite (USGS) were used to assess the quantitative recovery of acid dissolution and ion exchange chromatography and the accuracy of the Zn isotope ratio determinations. The RM 2709 San Joaquin soil (National Institute of Standards and Technology (NIST)), 1646a estuarine sediment (NIST) and 1573a tomato leaves (NIST) were analyzed to extent the isotope data set for environmental reference materials. The RMs BHVO-2, BCR-2 and AGV-2 were processed and analyzed for comparison with literature data.

Isotopic reference materials and data presentation

Stable isotopic variations are reported as relative values compared to reference material and generally expressed in terms of δ-values.11 Wiederhold, J.; Environ. Sci. Technol. 2015, 49, 2606. Zinc has five stable isotopes, 64Zn, 66Zn, 67Zn, 68Zn and 70Zn, with average natural abundances of 48.63, 27.90, 4.10, 18.75 and 0.62%, respectively.1212 Maréchal, C.; Télouk, P.; Albaréde, F.; Chem. Geol. 1999, 156, 251. The isotope ratio R(66Zn/64Zn) is commonly used because of the highest abundance of the isotopes 66Zn and 64Zn. In this work, the δ-values of Zn isotopic composition are expressed in per mil relative to the Zn standard Merck (No. 9953), henceforward labeled Zn UnB:

(1) δ 66 / 64 Zn UnB = R Zn 66 / Zn 64 sample R Zn 66 / Zn 64 UnB 1

Since common RMs are established as zero baseline for isotopic analyses, the results of different laboratories can be compared.1111 Cloquet, C.; Carignan, J.; Lehmann, M.; Vanhaecke, F.; Anal. Bioanal. Chem. 2008, 392, 451.,1212 Maréchal, C.; Télouk, P.; Albaréde, F.; Chem. Geol. 1999, 156, 251. To date, the δ66/64Zn values have been reported in relation to the RM Johnson Matthey® zinc (JMC 3-0749), labeled as δ66/64ZnJMC.1111 Cloquet, C.; Carignan, J.; Lehmann, M.; Vanhaecke, F.; Anal. Bioanal. Chem. 2008, 392, 451.,1212 Maréchal, C.; Télouk, P.; Albaréde, F.; Chem. Geol. 1999, 156, 251. Since this standard is no longer available, the Zn isotopic certified reference material from IRMM (IRMM-3702 (Zn)) has been adopted (δ66/64ZnIRMM).2727 Moeller, K.; Schoenberg, R.; Pedersen, R.; Weiss, D.; Dong, S.; Geostand. Geoanal. Res. 2012, 36, 177. Our Zn UnB Merck solution was calibrated against Zn JMC 3-0749 and IRMM-3702 to enable comparisons with values from literature.

Dissolution of reference materials

Soil, sediment and rock reference materials (RMs) were weighed in Savillex Teflon® beakers, with sample masses ranging from 20 to 150 mg, and digested using a multiple-step acid attack on a hot plate: (i) 1 mL of 14 mol L-1 HNO3 + 4 mL of 21 mol L-1 HF for 48 h; drying at 100 ºC; (ii) 3 mL of 6 mol L-1 HCl + 1 mL of 14 mol L-1 HNO3 for 24 h; drying at 100 ºC; (iii) 1 mL of 6 mol L-1 HCl + 0.5 mL of 14 mol L-1 HNO3 for 24 h; drying at 100 ºC; (iv) 1 mL of 6 mol L-1 HCl. Subsequently, the samples were dried again and re-dissolved in 1 mL of 2 mol L-1 HCl prior to Zn chromatographic purification (protocol details in the following sections). Blanks and RMs (BCR-2 or BHVO-2) were included in every sample batch as analytical controls in the elemental analysis. For the plant reference material (1573a tomato leaves), the digestion was performed using microwave digestion (Speedwave 4, Berghof) with an acid mixture of 3 mL of 21 mol L-1 HF + 5 mL of 14 mol L-1 HNO3 + 4 mL of 6 mol L-1 HCl. After digestion, the solution was transferred to Savillex Teflon® beakers dried on a hot plate at 100 ºC, dissolved in 1 mL of 2 mol L-1 HCl, dried again and re-dissolved in 1 mL of 2 mol L-1 HCl.

Determination of elemental concentration

Zinc concentrations in the acid dissolutions were determined using ICP OES (Spectroflame FVM03, Spectro Analytical Instrumental GmbH). Zinc in the purified fractions after chromatographic separation and in the procedural blanks were analyzed using Q ICP-MS (X Series 2, Thermo Scientific). The isotopes 66Zn, 68Zn, 49Ti, 47Ti, 52Cr, 53Cr, 56Fe and 57Fe were analyzed in CCT mode (collision cell technology), and 43Ca, 43Ca, 27Al, 24Mg, 25Mg and 23Na were analyzed in the standard mode. The accuracy of the concentration determinations in ICP OES and Q ICP-MS was verified with the certified values of the RMs BHVO-2 and BCR-2. The determined elemental concentrations were always within 10% of the certified values.

Zinc chromatographic separation: column specifications and development of the elution protocol

The zinc separation procedure was developed using Poly-prep Bio-Rad chromatography columns with 2 mL of bed volume (0.8 × 4 cm) and 9 cm height, loaded with AG MP1 Bio-Rad macro porous resins (100-200 mesh) and was based on the protocol originally published for the separation of Zn, Cu and Fe.1212 Maréchal, C.; Télouk, P.; Albaréde, F.; Chem. Geol. 1999, 156, 251.

Since Zn was the only element of interest, the protocol was modified to reduce time, reagents and sample mass (Table 1). In our protocol, the sample is directly loaded in the column with a molarity of 2 mol L-1, where Zn has a high sorptive capacity for the resin AG MP-1,3535 Kraus, K.; Moore, G.; J. Am. Chem. Soc. 1953, 75, 1460. thus avoiding undesirable losses of Zn during the matrix elution process.

The mass of sample loaded on the column was calculated to avoid saturation of exchange sites since amounts of Fe > 20% of theoretical resin saturation can lead to the early elution of light Zn isotopes and induce its fractionation.1313 Chapman, J.; Mason, T.; Weiss, D.; Coles, B.; Wilkinson, J.; Geostand. Geoanal. Res. 2006, 30, 5. Thus, the content of Fe in each sample was calculated so as not to exceed this value. Considering that the theoretical capacity of AG MP1 Bio-Rad resin is 1 meq mL-1, 2 mL of resin support 4 × 10-4 mol or 22.4 mg of Fe.1313 Chapman, J.; Mason, T.; Weiss, D.; Coles, B.; Wilkinson, J.; Geostand. Geoanal. Res. 2006, 30, 5. The resin was cleaned by passing three times 5 mL of 0.5 mol L-1 HNO3 and 5 mL of de-ionized water before and after each chromatographic procedure.

Assessment of the ion exchange chromatography procedure

The RMs 1646a estuarine sediment (NIST), 1573a tomato leaves (NIST), BHVO-2 basalt (USGS), BCR-2 basalt (USGS) and AGV-2 andesite (USGS) were used to assess the chromatographic separation with respect to recovery, reproducibility and matrix separation efficiency.

The recovery of Zn is a critical methodological step for its accurate isotopic determination since the ionic exchange process along the chromatographic column induces isotope fractionation throughout the Zn elution.3636 Maréchal, C.; Albarède, F.; Geochim. Cosmochim. Acta 2002, 66, 1499. The recovery was calculated from the difference between the amount of mass Zn recovered from purified solution at the end of chromatographic separation and the amount of Zn initially loaded on the column. The amount of Zn loaded on the column (1 to 3.5 µg) was calculated using the certified values of the elemental standards and RMs. The reproducibility was estimated as the relative standard deviation (RSD) from the Zn mass recovery of different replicates. In addition, possible chromatographic isotopic fractionation on the column was assessed measuring the Zn isotopic composition of the RM Zn UnB before and after the ion exchange procedure using the proposed protocol.

Matrix separation efficiency was assessed analyzing the residual matrix elements (Ti, Cr, Al, Fe, Mg and Ca) in the Zn fractions of RMs after passing through the column. Procedural blanks of the entire analytical protocol including digestion and chromatographic separation were performed during the processing of the sample batches.

Zinc isotope ratio measurements

Zinc isotopic compositions of sediment sample and reference materials were measured using a ThermoFinnigan Neptune MC-ICP-MS in the Laboratório de Geocronologia (UnB) and CPGeo (USP). Both instruments were configured in similar ways using the same inlet system, cones and acid concentrations. The typical operating conditions of the Neptune from both laboratories are shown in Table 2.

Table 2
Typical Neptune operating conditions of the USP and UnB laboratories

The inlet system consisted of a stable introduction system (SIS) composed by a tandem quartz glass spray chamber (cyclone plus standard Scott double pass) coupled with a low flow PFA nebulizer (50 µL min-1). The masses 62 (Ni), 63 (Cu), 64 (Zn/Ni), 65 (Cu), 66 (Zn), 67 (Zn) and 68 (Zn) were simultaneously detected using Faraday cups.

The analytical sequences ran automatically using a Cetac ASX-100 autosampler and low mass resolution collector slits, matching Cu and Zn concentrations at 300 µg L-1. Using the standard-sample bracketing technique, each sample was bracketed by a mixed isotopic reference solution (Zn UnB + Cu NIST SRM 976) with rinses between sample and standard analyses with 0.05 mol L-1 HNO3 from two different vials for 1 min each. Blank measurements consisted of 1 block of 10 cycles (8 s), while samples and isotopic reference solution were measured in 2 blocks of 20 cycles of 8 s each. For a single measurement (40 cycles), internal precision ranged from 3 to 8 ppm (2σ) for both Cu and Zn. An on-peak baseline correction was applied to correct instrumental and acid blank interference.

The Zn isotopic determinations of the RM samples were carried out on replicates prepared in separate batches (thus, separate digestion and chromatography for each batch). AGV-2 RM was prepared using a single aliquot.

Instrumental mass bias corrections

Mass bias (or instrumental fractionation) is a process in which isotopes of the same chemical element are transmitted with different efficiencies by the mass spectrometer resulting in non-uniform sensitivity across the mass range and inaccurate isotope ratio measurements.1414 Sossi, P.; Halverson, G.; Nebel, O.; Eggins, S.; Geostand. Geoanal. Res. 2014, 39, 129.,1515 Peel, K.; Weiss, D.; Chapman, J.; Arnold, T.; Coles, B.; J. Anal. At. Spectrom. 2008, 23, 103.,2929 Albarède, F.; Beard, B. L. In Geochemistry of Non-Traditional Stable Isotopes; Johnson, C. M.; Beard, B. L.; Albarède, F., eds.; Mineralogical Society of America: Washington, USA, 2004, ch. 4.,3131 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 218.,3737 Heumann, G. K.; Gallus, M. S.; Rädlinger, G.; Vogl, J.; J. Anal. At. Spectrom. 1998, 13, 1001.

The simplest technique used to correct mass bias is sample standard bracketing (SSB), consisting of analyzing an unknown sample bracketed by standards that are used to interpolate and correct the mass bias drift during data collection.1515 Peel, K.; Weiss, D.; Chapman, J.; Arnold, T.; Coles, B.; J. Anal. At. Spectrom. 2008, 23, 103.,3131 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 218. The SSB approach assumes that temporal drift in mass bias between bracketing standards is predictable and approximates to a simple mathematical expression (typically a linear interpolation), requiring a stable mass bias over the measurement session with no significant matrix-induced mass bias.1515 Peel, K.; Weiss, D.; Chapman, J.; Arnold, T.; Coles, B.; J. Anal. At. Spectrom. 2008, 23, 103.,2929 Albarède, F.; Beard, B. L. In Geochemistry of Non-Traditional Stable Isotopes; Johnson, C. M.; Beard, B. L.; Albarède, F., eds.; Mineralogical Society of America: Washington, USA, 2004, ch. 4.,3131 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 218.

Another technique widely applied is the external normalization which consists of doping samples and standard with an element with a known isotope composition and similar fractionation behavior to the element being analyzed (e.g., Zr doping to Mo isotope analysis, Mg doping for Si and Cu doping for Zn isotope analysis).1515 Peel, K.; Weiss, D.; Chapman, J.; Arnold, T.; Coles, B.; J. Anal. At. Spectrom. 2008, 23, 103.,3131 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 218.,3838 Longerich, H.; Fryer, B.; Strong, D.; Spectrochim. Acta, Part B 1987, 42, 39. The measured isotope ratio of the dopant can be compared to its known value to quantify instrument-induced fractionation (or factor of fractionation (f)) and a correction can then be applied to the isotope ratio of the target element.1515 Peel, K.; Weiss, D.; Chapman, J.; Arnold, T.; Coles, B.; J. Anal. At. Spectrom. 2008, 23, 103.,3131 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 218.,3838 Longerich, H.; Fryer, B.; Strong, D.; Spectrochim. Acta, Part B 1987, 42, 39. Different mathematical laws are used to associate the true isotopic composition with the measured values and the respective f values. For the instrumental fractionation (mass bias) of Zn and Cu, the exponential law (equation 2) has been indicated as the most appropriate law to describe it:1212 Maréchal, C.; Télouk, P.; Albaréde, F.; Chem. Geol. 1999, 156, 251.

(2) R meas = R true mass E i mass E j f

where iE and jE represent the masses of isotopes i and j of the analyte-element E; Rmeas and Rtrue represent the isotopic ratios experimentally measured and the true isotopic ratio of the analyte-element E, respectively.

Maréchal et al.1212 Maréchal, C.; Télouk, P.; Albaréde, F.; Chem. Geol. 1999, 156, 251. demonstrated that Cu and Zn isotopes do not fractionate to the same extent but the empirical relationship of f(Cu)/f(Zn) can be determined plotting the natural logarithm of the raw Cu and Zn isotope ratios of standards measured during an analytical session and can be used to correct the measured ratios of the analyte element. The corrected R(66Zn/64Zn) ratios for each sample and its bracketing standards are used to calculate the δ66/64Zn values by δ-equation (equation 1). In this work, external normalization was performed by doping samples and bracketing standards with Cu NIST SRM 976. The certified isotopic value of 0.4456 was used to correct the Zn isotopic ratios by the application of the exponential law.1212 Maréchal, C.; Télouk, P.; Albaréde, F.; Chem. Geol. 1999, 156, 251.

Effect of variable analyte-dopant (Zn/Cu) ratios on MC-ICP-MS

The extent of mass bias is a function of the analyte-dopant (Zn/Cu) ratio and plasma condition (wet versus dry).1919 Petit, J.; de Jong, J.; Chou, L.; Mattielli, N.; Geostand. Geoanal. Res. 2008, 32, 149.,2323 Chen, J.; Louvat, P.; Gaillardet, J.; Birck, J.; Chem. Geol. 2009, 259, 120. Wet plasma conditions show a stronger effect of the Zn/Cu ratio compared to the dry plasma (using Aridus I, DSN-100 or Apex HF), likely because of stronger turbulence effects during ionization, vaporization, atomization and excitation.2323 Chen, J.; Louvat, P.; Gaillardet, J.; Birck, J.; Chem. Geol. 2009, 259, 120. To this end, an experiment with sequential analysis of a mixed isotopic reference solution (Zn UnB + Cu NIST SRM 976) with variable concentration ratios ranging from 1 to 8 was conducted. The δ-values were calculated using the SSB and external normalization approaches to compare accuracy and precision for different concentration ratios (Cu/Zn) and mass bias correction methods. This experiment also allows the identification of the best Cu/Zn ratio to be used in the established method and offers a good opportunity to verify similarities and differences between instruments of the same model under different laboratory conditions.

Spectral and non-spectral interferences

Matrix elements induce spectral (isobaric) and non-spectral (matrix effects) interferences, inducing suppression or enhancement of signals, changes on sensitivity and instrumental mass bias, and overlap between the analyte isotopes and other elemental isobars (e.g., 64Ni at 64Zn), polyatomic ion species such as oxides (MO)+ and hydroxides (MOH)+ or double charged ions (e.g., 48Ca2+ at 24Mg).1919 Petit, J.; de Jong, J.; Chou, L.; Mattielli, N.; Geostand. Geoanal. Res. 2008, 32, 149.,2929 Albarède, F.; Beard, B. L. In Geochemistry of Non-Traditional Stable Isotopes; Johnson, C. M.; Beard, B. L.; Albarède, F., eds.; Mineralogical Society of America: Washington, USA, 2004, ch. 4.,3030 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 209.

Even in post-chromatographic separation procedures, some residual matrix elements can remain in the purified sample solution, affecting the accurate and precise determinations of Zn isotope ratios. As demonstrated in previous studies,1919 Petit, J.; de Jong, J.; Chou, L.; Mattielli, N.; Geostand. Geoanal. Res. 2008, 32, 149.,3030 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 209. Zn solutions doped with different elements (Na, Fe, Mg, Al, Ti, V, Cr, Ba and Ce) showed different magnitudes of interference on the Zn isotopic ratios, which Cr and Ti oxides and hydroxide ion species formed in the plasma were the main isobaric interferences for Zn isotopes. Other polyatomic species formed in the plasma (such as 27Al40Ar+) can cause strong isobaric interference while remaining major elements as Fe can induce matrix effects on Zn isotope ratio measurements.1919 Petit, J.; de Jong, J.; Chou, L.; Mattielli, N.; Geostand. Geoanal. Res. 2008, 32, 149.,3030 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 209. These studies, however, were carried out on VG Axiom, MicroMass Isoprobe and Nu Plasma,1919 Petit, J.; de Jong, J.; Chou, L.; Mattielli, N.; Geostand. Geoanal. Res. 2008, 32, 149.,3030 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 209. instead of in a MC-ICP-MS Neptune instrument.

In this work, we assessed the potential interferences of Fe, Cr, Al, Ti, Mg, Na and Ca in a Neptune MC-ICP-MS, doping the isotopic reference solution (Cu NIST SRM 976 + Zn UnB) with these representative matrix elements in the proportion of 1:1 at concentrations of 300 µg L-1. The interference magnitude on Zn isotope ratios was estimated using the δ66/64ZnUnB values for the doped reference isotopic solution against the average of the undoped bracketed isotopic reference solution using SSB and external normalization for mass bias correction.

Results and Discussion

Assessing the ion exchange chromatographic procedure: recovery, reproducibility, matrix separation and blanks

The experiment of Zn recovery using replicates of RMs is shown in Table 3. The chromatographic procedure yielded, on average, recovery of 99.3 ± 7.1% (σ, n = 16), which falls within the relative error of ± 10% for the certified concentration values of the CRMs analyzed by ICP OES and Q ICP-MS in our laboratories. Average reproducibility of replicates was ca. 5%, expressed as percentage of relative standard deviation of the replicates, indicating that the procedure including digestion and chromatographic separation is robust, and confirming quantitative recovery during the separation process. The RMs processed on the column and analyzed by MC-ICP-MS in an intra-run showed δ66/64Zn values of 0.01 ± 0.02‰ (3 replicates, σ, n = 6 measurements). This uncertainty is well within the reproducibility estimated from repeated measurements of the iCRM Zn IRMM-3702 relative to the RM Zn UnB during several analytical session-days (± 0.03‰, n = 30, Table 4), confirming that the chromatographic column does not induce significant isotopic fractionation on the samples.

Table 3
Zinc recovery yield and reproducibility data obtained for replicates of reference materials (RMs)
Table 4
Results of zinc isotope determinations of reference isotopic standards and reference materials (RMs)

The Q ICP-MS scan of all the samples and most of the certified reference materials processed using the ion exchange procedure showed efficient separation of potential interfering elements and Al/Zn, Mg/Zn, Ca/Zn, Na/Zn, Ti/Zn and Cr/Zn ratio were all below 0.001. The purified Zn fractions were free from the main potential interfering metals (Cr and Ti). The reference materials BHVO-2 (basalt) and estuarine sediment 1646a had Fe remaining after the chromatographic separation with Fe/Zn values corresponding to 0.12 and 0.02, respectively.

The blank contribution of our total procedure, including dissolution reagents and chromatography elution, was about 44 ± 14 ng (σ, n = 6), which corresponds to less than 0.1% of the total Zn found in samples. This low blank did not require any additional corrections.

Determining the optimum analyte-dopant ratio (Zn/Cu) of isotopic measurements

The effect of variable Cu/Zn ratios on the mass bias was investigated using bi-variant plots of raw Cu and Zn isotope ratios (i.e., ratios uncorrected for the mass bias effect) of standards in the ln-ln space (Figure 1). Straight lines indicating constant instrumental fractionation behavior of Zn and Cu confirming invariable f(Zn)/f(Cu) over the analytical sessions were found consistently. The slope ranges between 0.99 and 1.22 for the different Cu/Zn ratios, however, demonstrate that the mass bias behavior of Zn and Cu depends on the analyte/dopant ratio. Our results reinforce the importance of verifying empirically the relationship between the factor of fractionation of Zn (f(Zn)) and Cu (f(Cu)) for each analytical season if SBB is used, and also highlight the importance of matching dopant (Cu) analyte (Zn) concentrations of samples and standards.2323 Chen, J.; Louvat, P.; Gaillardet, J.; Birck, J.; Chem. Geol. 2009, 259, 120.

Figure 1
The effect of variable Cu/Zn ratios performed on the Neptune USP using the mixed reference isotopic solution (Zn UnB + Cu NIST SRM 976). The Cu/Zn ratio of 1 showed the closest slope to the theoretical value (ca. 0.96) and the best coefficient of determination (r2 = 0.99).

Table 5 shows the δ66/64Zn values and precision (expressed as 2σ of the total number measurements) of the mixed reference isotopic solution (Zn UnB + Cu NIST SRM 976) analyzed sequentially with different ratios of Cu/Zn. We found that variable Cu/Zn ratios do not have significant effects on the accuracy of δ66Zn values (all δ66Zn values obtained were close to 0.00 ± 0.01‰, σ, n = 31). However, the analytical precision (or external reproducibility) is affected by the different Cu/Zn ratios and hence the mass bias corrections (Table 5). The best external reproducibility (± 0.02‰, 2σ, n = 7) was obtained using the Cu/Zn ratio of 1 and correcting the ratios by external normalization through the exponential law. The Cu/Zn ratio of 1 yielded the best correlation and the slope closest to the theoretical value (0.96) indicating that ƒ(Cu) is approximately equal to ƒ(Zn). Therefore, this experiment shows that the higher the coefficient of determination (r2) between the natural logarithms of Cu and Zn, more precise will be the correction by the external normalization.

Table 5
Accuracy and reproducibility for the isotopic reference solution (Zn UnB + Cu NIST SRM 976) using different methods of mass bias correction and different Cu/Zn concentration ratios

Since instrument mass bias behavior can change day to day, a plot of the measurements of the mixed reference isotopic solution (Zn UnB + Cu NIST SRM 976) analyzed on consecutive days (n = 121) is presented in Figure 2. The results showed that the Cu/Zn ratio of 1 maintains the slope of the mass bias line close to 1.0 and a good correlation coefficient on both instruments. Throughout this study, the largest extent of mass bias was observed in the Neptune at UnB (Figure 2).

Figure 2
Plot of ln R(66Zn/64Zn) versus ln R(65Cu/63Cu) for 121 measurements of the isotopic solution (Zn UnB + Ni NIST 986) over several analytical sessions on consecutive days using the Neptune equipments from USP and UnB universities over a year. The slopes of the mass bias lines obtained in both instruments (1.17 at USP and 1.05 at UnB) are close to the theoretical value (ca. 0.96) indicating that f(Cu) is approximately equal to f(Zn). Moreover, both instruments maintained good correlations between the Cu and Zn isotopic ratios. In general, the Neptune from UnB showed large mass bias drift over time.

Summarizing our recent results using different Cu/Zn ratios, the use of Cu-doping in the proportion of 1:1 with Zn (at concentrations of 300 µg L-1) provided the more constant mass bias and consequently more precise results using the external normalization. Thus, the ratio Cu/Zn ratio of 1 was applied to all samples and isotopic reference solution measured in this study.

Assessing spectral and non-spectral interferences effects on Zn isotopic ratios

The doped isotopic reference solution (Zn UnB + Cu NIST SRM 976) with matrix elements, i.e., Fe, Cr, Al, Ti, Mg and Ca, showed a strong effect on the accuracy of the δ66/64Zn values (Figure 3). Chromium and titanium induced shifts higher than 0.1‰ due to the isobaric oxides and hydroxide ionic species (48Ti16O)+, (48Ti16OH)+, (52Cr16O)+ and (52Cr16O1H)+, while Fe, Al, Ca and Mg inducing lower shifts (< 0.1‰). This pattern was observed in previous studies1919 Petit, J.; de Jong, J.; Chou, L.; Mattielli, N.; Geostand. Geoanal. Res. 2008, 32, 149.,3030 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 209. and suggests that inlet systems and ICPs from different MC-ICP-MS models do not differ with respect to the production of interferences when operating in wet plasma. Mason et al.3030 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 209. found little differences in the formation and/or persistence of matrix related polyatomic species in the VG Axiom or the isoprobe instruments. Our data suggest that the MC-ICP-MS Neptune instrument operated in the wet mode is affected in a similar way to other instruments.

Figure 3
Interference assessed for different elements of the Zn isotopic compositions. The δ-values of doped mixed reference isotopic solution (Zn UnB + Cu NIST SRM 976) were calculated against the undoped bracketed mixed reference solution using the sample standard bracketing (SSB) and external normalization (Ext.) corrections.

Comparing the isotopic compositions by the different mass bias correction approaches, the external normalization method improved the precision compared to the SSB method. This demonstrates that external normalization is capable of attenuating (but not totally) the matrix effects, reinforcing the importance of chemical separation quality prior the chromatography. As demonstrated by Mason et al.3030 Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 209. and Petit et al.,1919 Petit, J.; de Jong, J.; Chou, L.; Mattielli, N.; Geostand. Geoanal. Res. 2008, 32, 149. the reductions of oxide and hydroxide ionic species using dry plasma or a second passage through the column are the best alternatives in case of remaining matrix elements on the sample solution.4242 Dong, S.; Weiss, D.; Strekopytov, S.; Kreissig, K.; Sun, Y.; Baker, A.; Formenti, P.; Talanta 2013, 114, 103.

Zn isotopic compositions of environmental RMs

The RM Zn UnB was calibrated against the iCRM Zn IRMM 3702 and the RM Zn JMC 3-0749 during several analytical sessions. The instrumental settings and analytical procedures were the same applied to the samples, using the external normalization for mass bias corrections, Cu-dopant and Zn-analyte matched at concentrations of 300 µg L-1 and the RM Zn UnB as a bracketed standard. The results are presented in Table 4 and the conversion of the δ66ZnUnB values to δ66/64ZnIRMM and δ66/64ZnJMC values is obtained applying the following equations:

(3) δ 66 / 64 Zn UnB = δ 66 / 64 Zn IRMM + 0 . 13
(4) δ 66 / 64 Zn UnB = δ 66 / 64 Zn JMC 0 . 14

The δ66/64ZnUnB and δ66/64ZnJMC-3-0749L determined for the iCRM Zn IRMM 3702 are presented in Table 4. The δ66/64ZnJMC-3-0749L values are shown to enable comparison with the literature since the δ66/64ZnJMC continues to be the more widely reported reference standard. Error propagations were used to calculate the error of δ66/64ZnJMC values (expressed as 2σ). The corresponding δ66/64ZnIRMM values can be obtained using equation 3.

The external reproducibility (2σ) for replicate measurements (n = 2 to 5) of RM with environmental matrices are below 0.1‰ (Table 4). For the synthetic RMs Zn UnB and Zn JMC 3-0749, the reproducibilities calculated from 34 measurements in different analytical sessions were 0.08 and 0.06‰, respectively.

The RMs BHVO-2 and BCR-2 were used to test critically the analytical accuracy of our analytical procedures as it allows comparison with previously published data (Table 4), while the RMs 2709 San Joaquin soil, 1646a estuarine sediment and 1573a tomato leaves are reported to enable future quality controls of Zn isotope ratio measurements related to environmental studies. The results of our BHVO-2 and BCR-2 (δ66/64ZnJMC = 0.25 ± 0.09 and 0.25 ± 0.10‰, 2σ, respectively) are in line with previously published values (Table 4) ranging between 0.2 and 0.3‰ associated to igneous rocks.4343 Chen, H.; Savage, P.; Teng, F.; Helz, R.; Moynier, F.; Earth Planet. Sci. Lett. 2013, 369, 34. The δ66/64ZnJMC value for 1646a estuarine sediment (0.32 ± 0.07‰, 2σ, n = 8) is close to typical values for igneous rocks, marine sediments and sapropels (0.23 ± 0.08‰, 2σ, n = 20; 0.28 ± 0.02‰, 2σ, n = 3, respectively).4141 Maréchal, C.; Nicolas, E.; Douchet, C.; Albarède, F.; Geochem. Geophys. Geosyst. 2000, 1, 1.

The δ66/64ZnJMC value for the 2709 San Joaquin soil is 0.28 ± 0.09‰ which is close to the δ66/64ZnJMC of 0.2‰ suggested for unpolluted soils.4444 Fekiacova, Z.; Cornu, S.; Pichat, S.; Sci. Total. Environ. 2015, 517, 96. The δ66/64ZnJMC values of 0.79 ± 0.09‰ (2σ, n = 8) for 1573a tomato are within the large range found in the plant leaves ranging from -0.91 to 0.63‰ for herbaceous species and 0.98 ± 0.19‰, 2σ for bamboo leaves.77 Viers, J.; Oliva, P.; Nonell, A.; Gelabert, A.; Sonke, J.; Freydier, R.; Gainville, R.; Dupre, B.; Chem. Geol. 2007, 239, 124.,4545 Moynier, F.; Pichat, S.; Pons, M.; Fike, D.; Balter, V.; Albarède, F.; Chem. Geol. 2009, 267, 125. The several factors of fractionation such as diffusive processes in cross-cell membrane transport, Zn bioavailable speciation and rhizosphere reactions4646 Jouvin, D.; Weiss, D.; Mason, T.; Bravin, M.; Louvat, P.; Zhao, F.; Ferec, F.; Hinsinger, P.; Benedetti, M.; Environ. Sci. Technol. 2012, 46, 2652.,4747 Coutaud, A.; Meheut, M.; Viers, J.; Rols, J.; Pokrovsky, O.; Chem. Geol. 2014, 390, 46. probably are associated to this heavy isotopic compositions of 1573a tomato leaves compared with soils and sediments.

Conclusion

A procedure for determining the Zn isotopic compositions in environmental samples has been developed through the co-operation between two Brazilian laboratories. The method focused on establishing a simple and fast chromatographic separation of Zn isotopes from complexes environmental matrices (soils, sediments, rocks and plants), on instrumental controls of mass bias and matrix interferences and on the determinations of Zn isotopic compositions in reference materials from NIST and USGS.

The chromatographic column calibration experiments showed a fit-for-purpose matrix separation, reproducibility (< 0.01‰, 5 ≤ n ≥ 1, 2σ) and practically 100% recovery yields. During analysis sessions, the instruments from both laboratories (ThermoFinnigan Neptune) presented similar mass bias behavior with f(Zn) approximately equal to f(Cu). External normalization (Ext.) using Cu NIST SRM 976 with the dopant/analyte ratio (Cu/Zn) of 1 produced more precise results than the SSB approach for the mass bias corrections. Investigations on spectral and non-spectral interferences in matrix-doped standards identified the formation of Cr and Ti oxides and hydroxide ionic species in the plasma as the main interferences on Zn isotope ratios. Other elements such Fe, Ca, Mg do not produce large interferences, with shifts commonly lower than 0.1‰.

Six certified reference materials (USGS and NIST materials) were analyzed: BHVO-2 basalt, BCR-2 basalt, AGV-2 andesite, San Joaquin soil SRM 2709, 1646a estuarine sediment and 1573a tomato leaves. In the case of rock RMs (BHVO-2 basalt, BCR-2 basalt and AGV-2 andesite), the δ66/64ZnJMC values were in agreement with values reported in the literature.

This work contributed with a simplified chromatographic protocol for Zn separation, additional insights about the mass bias processes in the MC-ICP-MS instruments and a new dataset of Zn isotopic compositions for environmental reference materials in order to fill a gap in the metrological traceability and analytical control of Zn isotopic data, and stimulate future inter-laboratorial calibrations.

Acknowledgments

CAPES and CNPq provided scholarships for Daniel Araújo that supported this work. We thank all the laboratory personnel of the Institute of Geosciences at UnB and USP, especially, Erico Zacchi, Myller Tonhá, Fernando Cavalcante and Jeane Chaves for their collaborations in this study. We thank Timothy Mulholland for his substantial support on the English grammar correction. We also thank the two anonymous reviewers for their valuable suggestions and comments.

References

  • 1
    Wiederhold, J.; Environ. Sci. Technol. 2015, 49, 2606.
  • 2
    Bullen, T. In Handbook of Environmental Isotope Geochemistry; Baskaran, M., ed.; Springer: Heidelberg, Germany, 2011.
  • 3
    Weiss, D.; Rehkdmper, M.; Schoenberg, R.; McLaughlin, M.; Kirby, J.; Campbell, P.; Arnold, T.; Chapman, J.; Peel, K.; Gioia, S.; Environ. Sci. Technol. 2008, 42, 655.
  • 4
    Yin, N.; Sivry, Y.; Benedetti, M.; Lens, P.; van Hullebusch, E.; Appl. Geochem. 2016, 64, 128.
  • 5
    Sonke, J.; Sivry, Y.; Viers, J.; Freydier, R.; Dejonghe, L.; Andre, L.; Aggarwal, J.; Fontan, F.; Dupre, B.; Chem. Geol. 2008, 252, 145.
  • 6
    Peel, K.; Weiss, D.; Siggc, L.; Limnol. Oceanogr. 2009, 54, 1699.
  • 7
    Viers, J.; Oliva, P.; Nonell, A.; Gelabert, A.; Sonke, J.; Freydier, R.; Gainville, R.; Dupre, B.; Chem. Geol. 2007, 239, 124.
  • 8
    Mulholland, D.; Poitrasson, F.; Boaventura, G.; Allard, T.; Vieira, L.; Santos, R.; Mancini, L.; Seyler, P.; Geochim. Cosmochim. Acta 2015, 150, 142.
  • 9
    Jaouen, K.; Pons, M.; Balter, V.; Earth Planet. Sci. Lett. 2013, 374, 164.
  • 10
    Larner, F.; Woodley, L.; Shousha, S.; Moyes, A.; Humphreys-Williams, E.; Strekopytov, S.; Halliday, A.; Rehkämper, M.; Coombes, R.; Metallomics 2015, 7, 112.
  • 11
    Cloquet, C.; Carignan, J.; Lehmann, M.; Vanhaecke, F.; Anal. Bioanal. Chem. 2008, 392, 451.
  • 12
    Maréchal, C.; Télouk, P.; Albaréde, F.; Chem. Geol. 1999, 156, 251.
  • 13
    Chapman, J.; Mason, T.; Weiss, D.; Coles, B.; Wilkinson, J.; Geostand. Geoanal. Res. 2006, 30, 5.
  • 14
    Sossi, P.; Halverson, G.; Nebel, O.; Eggins, S.; Geostand. Geoanal. Res. 2014, 39, 129.
  • 15
    Peel, K.; Weiss, D.; Chapman, J.; Arnold, T.; Coles, B.; J. Anal. At. Spectrom. 2008, 23, 103.
  • 16
    Irrgeher, J.; Prohaska, T.; Anal. Bioanal. Chem. 2015, 408, 23 369.
  • 17
    Sivry, Y.; Riotte, J.; Sonke, J.; Audry, S.; Schafer, J.; Viers, J.; Blanc, G.; Freydier, R.; Dupre, B.; Chem. Geol. 2008, 255, 295.
  • 18
    Thapalia, A.; Borrok, D.; Van Metre, P.; Musgrove, M.; Landa, E.; Environ. Sci. Technol 2010, 44, 1544.
  • 19
    Petit, J.; de Jong, J.; Chou, L.; Mattielli, N.; Geostand. Geoanal. Res. 2008, 32, 149.
  • 20
    Weiss, D.; Rausch, N.; Mason, T.; Coles, B.; Wilkinson, J.; Ukonmaanaho, L.; Arnold, T.; Nieminen, T.; Geochim. Cosmochim. Acta 2007, 71, 3498.
  • 21
    Conway, T.; Rosenberg, A.; Adkins, J.; John, S.; Anal. Chim. Acta 2013, 793, 44.
  • 22
    Chen, J.; Gaillardet, J.; Louvat, P.; Huon, S.; Geochim. Cosmochim. Acta 2009, 73, 4060.
  • 23
    Chen, J.; Louvat, P.; Gaillardet, J.; Birck, J.; Chem. Geol. 2009, 259, 120.
  • 24
    Gioia, S.; Weiss, D.; Coles, B.; Arnold, T.; Babinski, M.; Anal. Chem. 2008, 80, 9776.
  • 25
    Arnold, T.; Schönbächler, M.; Rehkämper, M.; Dong, S.; Zhao, F.; Kirk, G.; Coles, B.; Weiss, D.; Anal. Bioanal. Chem. 2010, 398, 3115.
  • 26
    Costas-Rodríguez, M.; Van Heghe, L.; Vanhaecke, F.; Metallomics 2014, 6, 139.
  • 27
    Moeller, K.; Schoenberg, R.; Pedersen, R.; Weiss, D.; Dong, S.; Geostand. Geoanal. Res. 2012, 36, 177.
  • 28
    Zhu, Z.; Jiang, S.; Yang, T.; Wei, H.; Int. J. Mass Spectrom. 2015, 393, 34.
  • 29
    Albarède, F.; Beard, B. L. In Geochemistry of Non-Traditional Stable Isotopes; Johnson, C. M.; Beard, B. L.; Albarède, F., eds.; Mineralogical Society of America: Washington, USA, 2004, ch. 4.
  • 30
    Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 209.
  • 31
    Mason, T.; Weiss, D.; Horstwood, M.; Parrish, R.; Russell, S.; Mullane, E.; Coles, B.; J. Anal. At. Spectrom. 2004, 19, 218.
  • 32
    Archer, C.; Vance, D.; J. Anal. At. Spectrom. 2004, 19, 656.
  • 33
    Vogl, J.; Pritzkow, W. In Isotopic Analysis: Fundamentals and Applications Using ICP-MS; Vanhaecke, F.; Degryse, P., eds.; Wiley-VCH Verlag GmbH & Co. KGaA: Weinheim, Germany, 2012, p. 139.
  • 34
    de Laeter, J. R.; Geostand. Geoanal. Res. 2005, 29, 53.
  • 35
    Kraus, K.; Moore, G.; J. Am. Chem. Soc. 1953, 75, 1460.
  • 36
    Maréchal, C.; Albarède, F.; Geochim. Cosmochim. Acta 2002, 66, 1499.
  • 37
    Heumann, G. K.; Gallus, M. S.; Rädlinger, G.; Vogl, J.; J. Anal. At. Spectrom. 1998, 13, 1001.
  • 38
    Longerich, H.; Fryer, B.; Strong, D.; Spectrochim. Acta, Part B 1987, 42, 39.
  • 39
    Herzog, G.; Moynier, F.; Albarède, F.; Berezhnoy, A.; Geochim. Cosmochim. Acta 2009, 73, 4365.
  • 40
    Moynier, F.; Beck, P.; Yin, Q.; Ferroir, T.; Barrat, J.; Paniello, R.; Telouk, P.; Gillet, P.; Chem. Geol. 2010, 276, 374.
  • 41
    Maréchal, C.; Nicolas, E.; Douchet, C.; Albarède, F.; Geochem. Geophys. Geosyst. 2000, 1, 1.
  • 42
    Dong, S.; Weiss, D.; Strekopytov, S.; Kreissig, K.; Sun, Y.; Baker, A.; Formenti, P.; Talanta 2013, 114, 103.
  • 43
    Chen, H.; Savage, P.; Teng, F.; Helz, R.; Moynier, F.; Earth Planet. Sci. Lett. 2013, 369, 34.
  • 44
    Fekiacova, Z.; Cornu, S.; Pichat, S.; Sci. Total. Environ. 2015, 517, 96.
  • 45
    Moynier, F.; Pichat, S.; Pons, M.; Fike, D.; Balter, V.; Albarède, F.; Chem. Geol. 2009, 267, 125.
  • 46
    Jouvin, D.; Weiss, D.; Mason, T.; Bravin, M.; Louvat, P.; Zhao, F.; Ferec, F.; Hinsinger, P.; Benedetti, M.; Environ. Sci. Technol. 2012, 46, 2652.
  • 47
    Coutaud, A.; Meheut, M.; Viers, J.; Rols, J.; Pokrovsky, O.; Chem. Geol. 2014, 390, 46.

Publication Dates