Acessibilidade / Reportar erro

Electrocatalytic and voltammetric determination of sulfhydryl compounds through iron nitroprusside modified graphite paste electrode

Abstracts

Iron nitroprusside Fe(II)NP was incorporated into a carbon paste electrode and the electrochemical studies were performed with cyclic voltammetry. The cyclic voltammogram of Fe(II)NP exhibits two redox couple with formal potential (E0')1 = 0.24 e (E0')2 = 0.85 V vs SCE attributed to Fe(II)/Fe(II) and Fe(II)(CN)5NO / Fe(III)(CN)5NO, respectively. The redox couple with (E0')2 = 0.85 V presents an electrocatalytic response for sulfhydryl compounds. The electrocatalytic oxidation of sulfhydryl compounds by the mediator has been used for the determination of L-cysteine and N-acetylcysteine. The modified graphite paste electrode gives a linear range from 9.2 ×10-4 <FONT FACE=Symbol>-</FONT> 2.0 ×10-2; 9.6 × 10-4 <FONT FACE=Symbol>-</FONT> 1.4 × 10-2mol L-1 for the determination of L-cysteine and N-acetylcysteine, respectively, with detection limit of 1.9 ×10-4 mol L-1; 1.5 × 10-4 mol L-1 and relative standard desviations ± 5% and 1.5 × 10-3 mol L-1 ± 4% (n=3). The amperometric sensitivities are 0.024 and 0.027 muA/mumol L-1 for L-cysteine and N-acetylcysteine, respectively. The application of this electrode was tested and a commercial pharmaceutical product (Fluimucil) has been determined.

iron nitroprusside; graphite paste electrode; L-cysteine; N-acetylcysteine; sulfhydryl compounds


O Nitroprussiato de ferro, Fe(II)NP foi incorporado em um eletrodo de pasta de grafite, sendo os estudos eletroquímicos realizados empregando a técnica de voltametria cíclica. O voltamograma cíclico de Fe(II)NP exibiu dois pares redox com potencial formal (E0')1 = 0,24 e (E0')2 = 0,85 V vs. SCE atribuídos a Fe(II)/Fe(III) e Fe(II)(CN)5NO / Fe(III)(CN)5NO, respectivamente. O par redox com (E0')2 = 0,85 V apresentou uma resposta eletrocatalítica para os compostos sulfidrílicos; L-cisteína e N-acetylcisteína. A oxidação eletrocatalítica dos compostos sulfidrílicos pelo mediador foi empregada para a determinação de L-cisteína e N-acetilcisteína. O eletrodo de pasta de grafite modificado para a determinação de L-cisteína e N-acetilcisteína apresenta uma linearidade de 9,2 × 10-4 <FONT FACE=Symbol>-</FONT> 2,0 × 10-2 e 9,6 × 10-4 <FONT FACE=Symbol>-</FONT> 1,4 × 10-2 mol L-1 com limite de detecção de 1,9 ×10-4 mol L-1 e 1,5 × 10-4 mol L-1 e desvio padrão relativo de ± 5 e 4% (n=3) e sensibilidade amperométrica de 0,024 e 0,027 miA/mimol L-1. A aplicação deste eletrodo foi testada determinando-se N- acetilcisteína em um fármaco (Fluimucil).


ARTICLE

Electrocatalytic and voltammetric determination of sulfhydryl compounds through iron nitroprusside modified graphite paste electrode

Devaney R. do Carmo; Ricardo M. da Silva; Nelson R. Stradiotto* * e-mail: nrstradi@iq.unesp.br

Instituto de Química, Universidade Estadual Paulista, CP 355, 14801-970 Araraquara - SP, Brazil

ABSTRACT

Iron nitroprusside Fe(II)NP was incorporated into a carbon paste electrode and the electrochemical studies were performed with cyclic voltammetry. The cyclic voltammogram of Fe(II)NP exhibits two redox couple with formal potential (E0')1 = 0.24 e (E0')2 = 0.85 V vs SCE attributed to Fe(II)/Fe(II) and Fe(II)(CN)5NO / Fe(III)(CN)5NO, respectively. The redox couple with (E0')2 = 0.85 V presents an electrocatalytic response for sulfhydryl compounds. The electrocatalytic oxidation of sulfhydryl compounds by the mediator has been used for the determination of L-cysteine and N-acetylcysteine. The modified graphite paste electrode gives a linear range from 9.2 ´ 10-4 – 2.0 ´ 10-2; 9.6 ´ 10-4 – 1.4 ´ 10-2mol L-1 for the determination of L-cysteine and N-acetylcysteine, respectively, with detection limit of 1.9 ´ 10-4 mol L-1; 1.5 ´ 10-4 mol L-1 and relative standard desviations ± 5% and 1.5 ´ 10-3 mol L-1 ± 4% (n=3). The amperometric sensitivities are 0.024 and 0.027 mA/mmol L-1 for L-cysteine and N-acetylcysteine, respectively. The application of this electrode was tested and a commercial pharmaceutical product (Fluimucil) has been determined.

Keywords: iron nitroprusside, graphite paste electrode, L-cysteine, N-acetylcysteine, sulfhydryl compounds

RESUMO

O Nitroprussiato de ferro, Fe(II)NP foi incorporado em um eletrodo de pasta de grafite, sendo os estudos eletroquímicos realizados empregando a técnica de voltametria cíclica. O voltamograma cíclico de Fe(II)NP exibiu dois pares redox com potencial formal (E0')1 = 0,24 e (E0')2 = 0,85 V vs. SCE atribuídos a Fe(II)/Fe(III) e Fe(II)(CN)5NO / Fe(III)(CN)5NO, respectivamente. O par redox com (E0')2 = 0,85 V apresentou uma resposta eletrocatalítica para os compostos sulfidrílicos; L-cisteína e N-acetylcisteína. A oxidação eletrocatalítica dos compostos sulfidrílicos pelo mediador foi empregada para a determinação de L-cisteína e N-acetilcisteína. O eletrodo de pasta de grafite modificado para a determinação de L-cisteína e N-acetilcisteína apresenta uma linearidade de 9,2 ´ 10-4 – 2,0 ´ 10-2 e 9,6 ´ 10-4 – 1,4 ´ 10-2 mol L-1 com limite de detecção de 1,9 ´ 10-4 mol L-1 e 1,5 ´ 10-4 mol L-1 e desvio padrão relativo de ± 5 e 4% (n=3) e sensibilidade amperométrica de 0,024 e 0,027 mA/mmol L-1. A aplicação deste eletrodo foi testada determinando-se N- acetilcisteína em um fármaco (Fluimucil).

Introduction

The chemical modification of electrodes is a field of growing interest in analytical chemistry. In electrochemistry, it has been demonstrated that chemically modified electrodes possess distinct advantages over conventional electrodes in numerous application areas including electrocatalysis and electrochemical sensors.1-7 One of the important properties of the chemical modified electrodes (CMEs), which has been the subject of considerable study, is their ability to catalyze the oxidation and reduction of solute species which exhibit high overpotential at unmodified electrode surfaces. The CMEs offer a possibility of lowering the overpotential and increasing sensitivity and selectivity of some electroactives species. In addition, they possess distinct advantages over mercury electrodes due to their possible toxicity or because of rapid deterioration of electrode response.8 Platinum and gold electrodes form surface oxides, also causing complications with analytical applications.9 From this point of view the graphite paste electrode offers advantages over the above mentioned methods.

One important group of inorganic compounds used for modification of graphite are the transition metal cyanoferrates in view of their well known catalytic activity.10-15 Metal nitroprusside films are not of easy preparation and these films are difficult to reproduce. The last proposition explains the small number of works in the literature and the different viewpoints among the authors.16 This work suggests the use of modified graphite paste electrode with iron nitroprusside for electrochemical studies. Characterization and electrochemical behavior of Fe(II)NP have been recently reported.17 In a second part of theses studies, we will describe the electrocatalytic properties of graphite paste electrode modified with iron nitroprusside as a mediator for oxidation of L-cysteine and N-acetylcysteine. These sulfhydryl compounds play very important role in living systems. As a direct application of the electrocatalytic properties of iron nitroprusside, N-acetylcysteine was determined in a pharmaceutical product (Fluimucil).

Experimental

Chemical reagents

L- cysteine hydrochloride monohydrate (L-cys) and N- acetylcysteine (N-acy) were used without further purification. All reagents and solvents were of analytical grade (Merck or Aldrich) and were used as purchased. All solutions and supporting electrolytes were prepared using Milli-Q water.

The L-cys and N-acy solutions were prepared immediately before use and were dearated with purified nitrogen. This procedure was adopted because this species can be oxidized to cystine and N-aceltylcystine, respectively, by atmospheric oxygen.

Measurements

Cyclic voltammetry was performed using an Auto Lab equipment (PGSTAT 30 –Eco chemie). The three electrode system used in these studies consisted of a modified working electrode (modified graphite paste electrode), a SCE reference electrode and a platinum wire as the auxiliary electrode.

Preparation of Fe(II)NP

The preparation and characterization of Fe(II)NP have been reported recently.17 A 0.05 mol L-1 solution of Fe(NH3)SO4, was added in slight excess to a 0.05 mol L-1 solution of commercially available Na2[Fe(CN)5NO]2H2O. The pH of the solution was adjusted (pH ~3.0) in order to prevent formation of Fe (II) hydroxide. The precipitates obtained were left overnight for aging, collected by filtration or centrifugation, washed with distilled water until sulfate ion could not be detected in the filtrate, finally washed with 95% ethanol, and dried over calcium chloride to constant weight.

Preparation of the graphite paste electrode modified with Fe(II)NP

The graphite paste electrode modified with Fe(II)NP was prepared by mixing 10 mg of Fe(II)NP with 90 mg of graphite (Aldrich) and 50 mL of mineral oil. The graphite paste with Fe(II)NP was included in a cavity with 2 mm inner diameter, connected with a copper wire.

Procedure

Initially, cyclic voltamograms were recorded for study the electrocatalysis of L- cysteine and N-acetylcysteine by graphite paste electrode modified with iron nitroprusside. The L-cysteine and N-acetylcysteine solutions were prepared immediately before use and were deaerated with nitrogen. In most of the experiments, 1.0 mol L-1 KCl ( pH ~ 6.8) was used as the supporting electrolyte. The catalytic current was estimated by the difference between the electrode current in the presence of sulfhydryl compounds and that which is established in the blank solution.

Procedure for the voltammetric determination of Fluimucil

In this study, we have applied the modified electrode to the determination of N-acetylcysteine in a pharmaceutical product (Fuimucil).

A standard aqueous solution of N- acetylcysteine 0.101 mol L-1 (stock solution) was preparated in water.

One commercial tablet (5.0348 g) was dissolved in water (25 mL). The standard addition method was employed for the quantification of Fluimucil. In an electrochemical cell filled with 20 mL 1.0 mol L-1 KCl, suitable aliquots (500 mL) were immediately added to the cell and the curves were registered after successive addition of 200 mL of the standard solution of the sample. The experiments were done in triplicate.

Results and Discussion

The electrochemical behavior of iron nitroprusside modified graphite paste electrode, already described in report recent,17 exhibits two redox couples. The electrocatalysis of graphite paste electrode modified with Fe(II)NP for electro-oxidation of L-cys and N-acy in a 1.0 mol L-1 KCl solution is showed in Figures 1 and 2. It can be seen that the electrochemical behavior of L-cysteine and N- acetylcysteine is similar.



Figures 1 and 2 show cyclic voltammograms of Fe(II)NP in absence (curve c) and presence (curve d) of L-cysteine and N-acetylcysteine respectively. The carbon paste electrode displays no redox peaks in the potential range from -0.3 to 1.2 V in absence or presence of sulfhydryl compounds (see curves a and b, respectively). After the addition of these sulfhydryl compounds, a substantial enhancement of the anodic peak current is observed (curve d). The peak current increased in proportion to the analyte concentration. This increase in anodic current indicates the electrocatalytic oxidation of sulphydril compound by the Fe(II)NP mediator. The Fe(III) produced during the anodic scan chemically oxidizes sulfhydryl compounds while it is reduced to Fe(II), which will be again electrochemically oxidized to Fe(III).

The electrochemical oxidation of L-cysteine18 can be written as:

Sulfhydryl oxidation reactions at the iron nitropruside modified paste electrode electrode interface can be described by the following reactions:

where X = L-cys or N-acy and Y = L- cystine or N-acetylcystine.

Thus L-cysteine and N-acetylcysteine are electrocatalytically oxidized at the electrode surface and the oxidation process stars at 0.85 V. Compared to L-cysteine or N-acetylcysteine at the bare glassy carbon electrode this oxidation does not occur. The potential peak is not affected by sulfhydryl concentration and the catalytic current peak varies linearly with square root of the sweep rate. This indicates that the electrocatalytic process is controlled by diffusion.

The electrochemical behaviour of cysteine and N-acetylcysteine oxidation of iron nitroprusside exhibit only one oxidation peak at 0.85 V (vs. SCE), different from the Prussian Blue film modified electrode, that exhibits in the presence of cysteine and N-acetylcysteine, two oxidation peaks at about 0.79 and 0.95 V. (1.0 mol L-1 KCl, pH 3.0 vs. Ag/AgCl).19

Also, differently from Prussian Blue19 whose film disintegrates by hydrolysis in solutions of pH higher than 5, this hydrolysis with Fe(II)NP happens at pH > 8. The Fe(II)NP utility is limited only at pH < 2.5 because at higher concentration of protons an additional peak is present.17 Another important aspect of the electrocatalysys of sulfhydryl compounds is that the catalytic current decreases slightly with time after the first scan, probably due to depletion of sulfhydryl compounds19 near the electrode surface or the electrode is blocked by reaction products.20

Calibration graphs for the amount of sulphydryl compounds (L-cysteine and N-acetylcysteine) versus anodic current are shown in Figures 3 and 4.



The modified electrode gives a linear responce from 9.2 ´ 10-4 to 2.0 ´ 10-2 mol L-1 (r = 0.998) and 9.6 ´ 10-4 to 1.4 ´ 10-2 mol L-1 (r = 0.997)for the determination of cysteine and N-acetylcysteine, respectively, with detection limits of 1.9 ´ 10-4 mol L-1 and 1.5 ´ 10-4 mol L-1 and standard deviations of 5% and 4% (n = 3) for L-cystine and N-acetylcysteine, respectively. The amperometric sensitivities were 0.024 and 0.027 mA/mmol L-1 for L-cysteine and N-acetylcysteine.

The linear dependence of the calibration curve in Figures 3 and 4 suggests that the response of modified electrode is appropriated for quantitative L-cysteine and N-acetylcysteine determination even in the millimolar concentration range. Such a wide concentration range of analytical useful response was also reported for L-cysteine determination by chemically modified electrodes.20

Similar to methods involving mercury electrodes, the calibration plot crosses the abscissa, presumably owing to the interference of trace heavy metal in supporting electrolytes,21 but this does not interfere with the success for determination of sulfhyldryl compounds by addition methods. For L-cysteine determination the linear range and detection limit increase when comparated with N-acetylcysteine but the sensitivity is practically the same. The reproducibility is satisfactory for the investigated concentration range (RSD 5% and 4.1% for L-cysteine and N-acetilcysteine, respectively). The main electrochemical characteristic of iron nitroprusside modified paste electrode is that it could be re-used after an unique washing with Milli Q water, and it is not necessary to remove the electrode surface. Table 1 lists the main analytical parameters of these studies.

Detemination of N-acetylcysteine in tablet

Figure 5 shows the voltammograms of Fe(II)NP with addition of aliquots of Fluimucil and subsequent additions of N-acetylcysteine solutions.


The standard addition method was applied for pharmaceutical product determination. The values obtained by this procedure (205 ± 0.4 mg) (n=3) are comparable and agree well with the amount declared in these tablets (200 mg).

Conclusions

Iron nitroprusside, Fe(II)NP, presents two redox couples at 0.24 and 0.85 V ( KCl 1.0 mol L-1; v =20 mV s-1vs SCE). The voltammetric performance of insoluble solid incorporated in carbon paste electrode does not depend on pre-electrochemical treatment. The electrode preparation is simpler than the others processes of modification. An electrode surface renewal is not necessary as only a simple electrode washing is enough before each experiment. The electrode is chemically and electrochemically stable.

The second redox couple presents electrocatalytic property towards sulphydryl compounds. Quantitative determination in the millimolar range of N-acetylcysteine in a pharmaceutical product (Fluimucil) can be achieved using Fe(II)NP incorporated in carbon paste electrode. This method is simple and convenient, and no separation step nor elimination of strange species is required.

Acknowledgements

The authors acknowledge FAPESP for financial support.

Received: February 19, 2003

Published on the web: August 14, 2003

FAPESP helped in meeting the publication costs of this article.

  • 1. Ijeri,V.S.; Jaiswal, P.V.; Scrivastava, A.K.; Anal. Chim. Acta 2001, 439, 291.
  • 2. Wring, S.A.; Hart, J.P.; Analyst 1992, 117, 1215.
  • 3. Mafatli,T.J.; Nyokong, I.; J.Electroanal.Chem 1996, 408, 213.
  • 4. Golabi, S.M.; Zare, H.R.; Hamzehloo, M.; Electroanalysis 2002, 14 , 611.
  • 5. Totir, N.; Luca C.; Lupu, S.; Lete, C.; Ion A.C.; Rev. Roum. Chim. 2001, 46, 555.
  • 6. Haubey, A.C.; Malhotra, B.D.; Biosens. Bioelectron2002, 17, 441.
  • 7. Razmi-Nerbin, H.; Pournaghi-Azar, M.H.; J. Solid State Electrochem 2002, 6, 126.
  • 8. Bergstron R.F.; Kay D.R.; Wagner J.E.; J.Chromatogr 1981, 222, 445.
  • 9. Jobll, M.E.; Williams D.G.; Johnson, D.C.; Electroanalysis 1997, 9, 1397.
  • 10. Shakaran, D.R.; Narayanan , S.S.; Bull.Electrochem 1998, 4, 267.
  • 11. Chen,S.M.; J.Electroanal. Chem 2002, 521, 29.
  • 12. De Mattos I.L.; Gorton L.; Quim. Nova 2001, 24, 200.
  • 13. De Toccani N.R.; K. Rajeshwar; Lesna, R.O.; Electrochim. Acta 2000, 45, 3403.
  • 14. Garjonyté, R.; Malinauskas, A.; Sens. Actuators, B 1998, 46, 236.
  • 15. Cui, X.P.; Hong L.; Lin X.Q.; Anal. Sci 2002, 18, 543.
  • 16. Ivanov, V.D.; Kaplum, M.M.; Russ. J. Electrochem 1998 , 14, 559.
  • 17. Do Carmo, D.R.; Da Silva, R.M.; Stradiotto, N.R.; Ecl. Quim 2002, 27, 197.
  • 18. Ralph,T.R.; Hitchman, M.L.; Millington J.P.; Walsh F.C.; J. Electroanal. Chem 1994, 375, 1.
  • 19. Hou, W.; Wang, E.; J.Electroanal.Chem 1991, 316, 155
  • 20. Sãpataru, N.; Sarada, B.V.; Popa, E.; Tryk, D.A.; Fujishima, A.; Anal. Chem 2001, 73, 514.
  • 21. Florence, T.M.; J.Electroanal. Chem 1979, 97, 237.
  • *
    e-mail:
  • Publication Dates

    • Publication in this collection
      16 Sept 2003
    • Date of issue
      Aug 2003

    History

    • Accepted
      14 Aug 2003
    • Received
      19 Feb 2003
    Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil