Acessibilidade / Reportar erro

Evaluation of determination of prothrombin time in blood samples using two different collection techniques

The objective of the present study is to evaluate the interference of different blood collection techniques in determining prothrombin time. Two collection techniques were used. One of them uses the vacuum system and the other, manual aspiration using plastic syringe. The obtained values of determination of prothrombin time from these two techniques were compared. We analyzed patients’ samples that presented normal and non-normal prothrombin time owing to oral treatment with anticoagulant medication. The conclusion was that the collection processes using either vacuum system or manual aspiration with plastic syringe to obtain samples destined to the prothrombin time analysis do not interfere in the test result and the obtained values. In comparing both collecting techniques we did not find any significant statistical differences.

Prothrombin; Oral anticoagulant; Vitamin K; Bleeding; Thromboembolism


Sociedade Brasileira de Patologia Clínica, Rua Dois de Dezembro,78/909 - Catete, CEP: 22220-040v - Rio de Janeiro - RJ, Tel.: +55 21 - 3077-1400 / 3077-1408, Fax.: +55 21 - 2205-3386 - Rio de Janeiro - RJ - Brazil
E-mail: jbpml@sbpc.org.br