Acessibilidade / Reportar erro

Injection Shrinkage аnd Water Sorption of Some Thermoplastic Dental Materials

Abstract

Objective:

To evaluate the change of diameter of different injection-molded thermoplastic materials.

Material and Methods:

Four thermoplastic injection-molded materials were analyzed (Bre.flex 2nd edition, Vertex ThermoSens, Perflex Biosens and Polyan IC). A total of 432 test samples were made in the form of an "hourglass". All samples were divided into three groups: Group I (Control) - consisting of 36 test samples for each type of material, that was not exposed to artificial aging or a wet environment; Group II - consisting of 36 test samples for each type of material, that were artificially aged through dehydration; Group III - specimen were subjected to artificial aging without dehydration. The diameter of each specimen was measured with a digital caliper. Data were analysed using the Student's t-test.

Results:

Regarding to shrinkage, the samples from the Bf Control group have a mean value of 1.56 mm and was observed a shrinkage of the injection-molded polyamide material within 0.25%. The comparison between the samples from Group II and Group III showed statistically significant differences (p<0.001). There were no significant differences between groups for Thermosens and Biosens (p>0.05). The comparison between Group II and Group III for Polyan IC samples shows that Group III has a higher arithmetic mean value (p<0.01).

Conclusion:

Shrinkage of the polymers during the injection process is present in all materials. The thermocycling and the storage in a dry or in a wet environment of the samples results in a change of the diameter in almost every single type of material.

Keywords:
Dental Impression Materials; Dental Prosthesis; Denture Bases

Associação de Apoio à Pesquisa em Saúde Bucal Avenida Epitácio Pessoa, 4161 - Sala 06, Miramar, CEP: 58020-388, João Pessoa, PB - Brasil, Tel.: 55-83-98773 2150 - João Pessoa - PB - Brazil
E-mail: apesb@terra.com.br