Abstract

Objective:

To compare the reliability of cone beam computed tomography (CBCT) in assessing the tooth length in comparison to orthopantomography (OPG).

Material and Methods:

Forty patients scheduled for extraction as result of caries or periodontal involvements were randomly selected. Panoramic radiographs and CBCT images were obtained and subsequently patients were subjected for extraction. Teeth with poor prognosis were extracted and stored in 10% formalin. Radiographic teeth measurements were carried out on OPG and CBCT images using a software and the actual tooth length (A-L) measurements were carried out with a digital vernier caliper. The data collected were statistically analyzed for paired “t” test significance of differences and Pearson's correlation at 5% level of confidence.

Results:

There was significant difference comparing all three actual tooth length (A-L) and CBCT- and OPG-measured tooth lengths. A significant positive correlation was observed among all the measurements.

Conclusion:

CBCT images exhibited accuracy over panoramic images even though the measurements are still significantly different from actual anatomical tooth lengths.

Keywords:
Cone-Beam Computed Tomography; Radiography, Panoramic; Tooth

Introduction

A radiographic examination is an essential part of the diagnostic process in dentistry and it is also known that tooth length plays an important role in many branches of dentistry. Radiographic tooth length is useful in evaluating the orthodontic treatment effects such as root resorption, development and anchorage. Endodontically, it helps in assessing the working length. In prosthetics it helps in making better judgment about the selection of abutment and in periodontics it helps in comparing tooth length or root length and alveolar crestal levels [1[1] Pretty IA, Sweet D. A look at forensic dentistry - Part 1: The role of teeth in the determination of human identity. Br Dent J 2001; 190(7):359-66. https://doi.org/10.1038/sj.bdj.4800972a
https://doi.org/10.1038/sj.bdj.4800972a...

[2] Flores-Mir C, Rosenblatt MR, Major PW, Carey JP, Heo G. Measurement accuracy and reliability of tooth length on conventional and CBCT reconstructed panoramic radiographs. Dental Press J Orthod 2014; 19(5):45-53. https://doi.org/10.1590/2176-9451.19.5.045-053.oar
https://doi.org/10.1590/2176-9451.19.5.0...
-3[3] Sameshima GT, Asgarifar KO. Assessment of root resorption and root shape: Periapical vs panoramic films. Angle Orthod 2001; 71(3):185-89.]. Several methods of determining tooth length exists [2[2] Flores-Mir C, Rosenblatt MR, Major PW, Carey JP, Heo G. Measurement accuracy and reliability of tooth length on conventional and CBCT reconstructed panoramic radiographs. Dental Press J Orthod 2014; 19(5):45-53. https://doi.org/10.1590/2176-9451.19.5.045-053.oar
https://doi.org/10.1590/2176-9451.19.5.0...
], but most preferred way of determining the root canal length is by radiographs mainly by the intraoral periapical radiography and orthopantomography. The major advantages of the orthopantomography (OPG) include less radiation exposure, decreased patient chair time, minimal operator time, better patient co-operation, and added benefit of visualizing of entire lower half of the face [4[4] Rushton VE, Horner K. The use of panoramic radiology in dental practice. J Dent 1996; 24:185-201. https://doi.org/10.1016/0300-5712(95)00055-0
https://doi.org/10.1016/0300-5712(95)000...
].

Although panoramic radiography is often used in diagnosis, a full mouth examination consisting of 14 or more periapical radiographs is performed occasionally as periapical radiographs are considered to be of higher image quality [5[5] Ezoddini Ardakani F, Zangouie Booshehri M, Behniafar B. Evaluation of the distortion rate of panoramic and periapical radiographs in erupted third molar inclination. Iran J Radiol 2011; 8:15-21.]. As a single panoramic film can provide same data with less radiation exposure OPG replaced periapical radiographs.

OPG images known to have some shortcomings like magnification, unsharpness, distortion, etc., and the CBCT images are to be free from these disadvantages. Therefore, this study was carried out to assess the reliability of cone beam computed tomography (CBCT) in assessing the tooth length in comparison to orthopantomography (OPG).

Material and Methods

Sample

Forty patients who were scheduled for extraction as a result of caries or periodontal involvement were selected randomly. Sixty-one extracted maxillary and mandibular posterior teeth were analyzed. Patients who were having tooth which were indicated for extraction, provided the tooth structure is sound, were included in the study. Patients having medical conditions, which are contraindications for extraction like thyrotoxicosis, patients with immediate post radiation therapy and those undergoing extraction of grossly destructed tooth were excluded from the study. Teeth with metallic restoration and severe attrition of the crown were not included in this study.

Data Collection

Panoramic imaging was carried out by Cranex (Soredex, Tuusula, Finland), the measurements were carried out on these images using the accompanying software by marking a highest point on the crown and lowest point on the root apex. The CBCT scans were obtained by Scanora 3D (Soredex, Tuusula, Finland) with 6 mA and 89 kVp and the evaluation of the scans were carried out with the accompanying software. The CBCT images were obtained at a field of view (FOV) of 5 × 8 cm and each tooth was individually localized in the multiplanar reconstruction view in axial, coronal and sagittal planes and the tooth lengths were recorded on each respective section in the sagittal plane. The images were optimized by adjusting contrast and brightness with the aid of processing tool for better viewing. The extracted teeth were stored in 10% formalin and the actual tooth size was determined with a digital vernier caliper.

Statistical Analysis

The findings were statistically analyzed and compared in relation to accuracy and reliability of tooth measurements using Pearson's correlation and paired t test. A statistical significance was set at 5% level of significance (p<0.05).

Ethical Aspects

Clearance was obtained from the institutional Ethical Committee (# 8-20-3/40) and all the patients were voluntarily participated in the study.

Results

The mean, standard deviation and standard error values of tooth length measurements by actual length, CBCT length and OPG length are presented in the Table 1.

Table 1
Mean and median values of tooth length measurements by Actual, CBCT and OPG.

A significant difference was observed between actual length and CBCT length (t=7.6662, p=0.0001), actual length and OPG length (t=-10.3680, p=0.0001); CBCT and OPG length measurement (t=-11.7234, p=0.0001) of mandibular molar.

A significant and positive correlation was observed between actual length and CBCT length (r=0.9840, p=0.0001), actual length and OPG length (r=0.8734, p=0.0001), CBCT length and OPG length (r=0.8556, p=0.0001) of mandibular molar. It signified that actual length, CBCT length of mandibular molar was highly correlated and dependent on each other, but CBCT and OPG length are less correlated. However, a significant and positive correlation was observed between actual length and CBCT length (r=0.8641, p<0.05), actual length and OPG length (r=0.9777, p<0.05), CBCT length and OPG length (r=0.7627, p<0.05) of mandibular premolar. It implied that actual length, CBCT length and OPG lengths of mandibular premolar were dependent on each other.

Table 2
Co-relation and paired teeth test of mandibular tooth length measurements.

A significant difference was observed between actual length and CBCT length (t=9.8904, p=0.0001), actual length and OPG length (t=-5.4694, p=0.0001); CBCT and OPG length measurement (t=-7.6911, p=0.0001) of maxillary premolars. A significant difference was observed between actual length and CBCT length (t=14.9440, p=0.0001), actual length and OPG length (t=-9.2081, p=0.0001); CBCT and OPG length measurement (t=-13.7037, p=0.0001) of maxillary molars- palatal.

A significant difference was observed between actual length and CBCT length (t=10.1097, p=0.0001), actual length and OPG length (t=-10.2822, p=0.0001); CBCT and OPG length measurement (t=-11.6468, p=0.0001) of maxillary molars- buccal.

A significant and positive correlation was observed between actual length and CBCT length (r=0.9620, p<0.05), actual length and OPG length (r=0.7863, p<0.05) and CBCT length and OPG length (r=0.6783, p<0.05) of maxillary premolar. This revealed that, actual length, CBCT length and OPG lengths of maxillary premolar were dependent on each other.

However, a significant and positive correlation was observed between actual length and CBCT length (r=0.9257, p<0.05), actual length and OPG length (r=0.7278, p<0.05), CBCT length and OPG length (r=0.5887, p<0.05) of maxillary molars- palatal. It implied that, actual length, CBCT length and OPG lengths of maxillary molars- palatal were dependent on each other.

Similarly, a significant and positive correlation was observed between actual length and CBCT length (r=0.8660, p<0.05), actual length and OPG length (r=0.7463, p<0.05), CBCT length and OPG length (r=0.4888, p<0.05) of maxillary molars- buccal. It implied that, actual length, CBCT length and OPG lengths of maxillary molars- buccal were dependent on each other. But a significant and moderate positive correlation was observed between CBCT length and OPG lengths of maxillary molars - palatal and buccal sides.

Table 3
Co-relation and paired t test of maxillary tooth length measurements.

Discussion

The reliability of radiographic estimation of the tooth length has always been of concern to a dentist. The objective of this study was to assess the reliability of tooth length determination by OPG and CBCT in a clinically relevant manner. By selecting teeth scheduled for extraction a benefit of confidently measuring the actual tooth length was obtained. Anterior teeth were excluded from this initial phase of study because in an OPG image the anterior teeth are more susceptible to be distorted, unsharp and unclear representation. Despite of its limitations, OPG is replacing full mouth IOPA's as a preoperative screening radiograph and it is widely available and economical than CBCT [6[6] Molander B. Panoramic radiography in dental diagnostics. Swed Dent J 1996; 119(Suppl):1-26.].

Studies were carried out in literature to know the reliability of OPG for the other applications other than measurement of toot length. A previous research compared panoramic and intra-oral radiographs for to assess the alveolar bone levels in a periodontal maintenance population and found that the OPG measurements may, at any rate to some extent, substitute for full-mouth periapical radiographic assessment [7[7] Persson RE, Tzannetou S, Feloutzis AG, Brägger U, Persson GR, Lang NP. Comparison between panoramic and intra-oral radiographs for the assessment of alveolar bone levels in a periodontal maintenance population. J Clin Periodontol 2003; 30(9):833-9. https://doi.org/10.1034/j.1600-051X.2003.00379.x
https://doi.org/10.1034/j.1600-051X.2003...
]. Another study investigated the reliability of periapical radiographs and orthopantomograms to determine the tooth root protrusion in the maxillary sinus by associating the outcomes with CBCT and found that that both the methods were not reliable to identify the exact correlation between the apex of tooth root and the floor of maxillary antrum. Periapical radiographs were slightly more dependable than panoramic radiographs in identifying this relationship [8[8] Hassan BA. Reliability of periapical radiographs and orthopantomograms in detection of tooth root protrusion in the maxillary sinus: Correlation results with cone beam computed tomography. J Oral Maxillofac Res 2010; 1(1):e6. https://doi.org/10.5037/jomr.2010.1106
https://doi.org/10.5037/jomr.2010.1106...
].

CBCT is a latest imaging technique that has been regarded as a dependable diagnostic modality in recent dental practice as it overcomes numerous shortcomings of conventional radiographic techniques by giving precise details [9[9] Patil SR, Ghani HA, Almuhaiza M, Al-Zoubi IA, Anil KN, Misra N, Raghuram P H. Prevalence of pulp stones in a Saudi Arabian subpopulation: A cone-beam computed tomography study. Saudi Endod J 2018; 8:93-8. https://doi.org/10.4103/sej.sej_32_17
https://doi.org/10.4103/sej.sej_32_17...

[10] Patil SR, Araki K, Ghani HA, Al-Zoubi IA, Sghaireen MG, Gudipaneni RK, et al. A cone beam computed tomography study of the prevalence of pulp stones in a Saudi Arabian adolescent population. Pesqui Bras Odontopediatria Clín Integr 2018; 18(1):e3973. https://doi.org/10.4034/PBOCI.2018.181.45
https://doi.org/10.4034/PBOCI.2018.181.4...

[11] Sinha N, Singh B, Patil S. Cone beam computed topographic evaluation of a central incisor with an open apex and a failed root canal treatment using one-step apexification with Biodentine™: A case report. J Conserv Dent 2014; 17:285-9. https://doi.org/10.4103/0972-0707.131805
https://doi.org/10.4103/0972-0707.131805...

[12] Al-Zoubi IA, Patil SR, Takeuchi K, Misra N, Ohno Y, Sugita Y, Maeda H, Alam MK. Analysis of the length and types of root trunk and length of root in human first and second molars and to the actual measurements with the 3D CBCT. J Hard Tissue Biol 2018; 27(1):39-42. https://doi.org/10.2485/jhtb.27.39
https://doi.org/10.2485/jhtb.27.39...
-13[13] Alam MK, Alhabib S, Alzarea BK, Irshad M, Faruqi S, Sghaireen MG, et al. 3D CBCT morphometric assessment of mental foramen in Arabic population and global comparison: Imperative for invasive and non-invasive procedures in mandible. Acta Odontol Scand 2018; 76(2):98-104. https://doi.org/10.1080/00016357.2017.1387813
https://doi.org/10.1080/00016357.2017.13...
]. Images with good resolution and lack of superimposition are some of the additional benefits of CBCT imaging [14[14] Patil SR, Alam MK, Moriyama K, Matsuda S, Shoumura M, Osuga N. 3D CBCT assessment of soft tissue calcification. J Hard Tissue Biol 2017; 26(3):297-300. https://doi.org/10.2485/jhtb.26.297
https://doi.org/10.2485/jhtb.26.297...

[15] Al-Zoubi IA, Patil SR, Kato I, Sugita Y, Maeda H, MK. 3D CBCT Assessment of incidental maxillary sinus abnormalities in a Saudi Arabian population. J Hard Tissue Biol 2017; 26:369-72. https://doi.org/10.2485/jhtb.26.369
https://doi.org/10.2485/jhtb.26.369...

[16] Patil SR, Araki K, Yadav N, Ghani HA. Prevalence of hypercementosis in a Saudi Arabian population: A cone beam computed tomography study. J Oral Res 2018; 7(3):94-7. https://doi.org/10.17126/JORALRES.2018.022
https://doi.org/10.17126/JORALRES.2018.0...

[17] Patil SR, Maragathavalli G, Araki K, Al-Zoubi IA, Sghaireen MG, Gudipaneni RK, et al. Three-rooted mandibular first molars in a Saudi Arabian population: A CBCT study. Pesqui Bras Odontopediatria Clín Integr 2018; 18(1):e4133. https://doi.org/10.4034/PBOCI.2018.181.87
https://doi.org/10.4034/PBOCI.2018.181.8...
-18[18] Patil SR, Raghuram PH, Munisekhar MS, Shailaja G, Gudipanen RK, Alam MK. CBCT evaluation of an unusual case of florid cemento osseous dysplasia in an old female. Int Med J 2018; 25(5):335-6.].

Different results exist in the literature regarding the accuracy of the measurements obtained from CBCT images [19[19] Lascala CA, Panella J, Marques MM. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-newTom). Dentomaxillofac Radiol 2004; 33(5):291-4. https://doi.org/10.1259/dmfr/25500850
https://doi.org/10.1259/dmfr/25500850...
]. Few studies report the underestimations of the measurements, and some claim proposed that the measurements match the actual measurements [20[20] Lagravère MO, Carey J, Toogood RW, Major PW. Three-dimensional accuracy of measurements made with software on cone-beam computed tomography images. Am J Orthod Dentofacial Orthop 2008; 134(1):112-6. https://doi.org/10.1016/j.ajodo.2006.08.024
https://doi.org/10.1016/j.ajodo.2006.08....
]. Previous, a study was carried out to know the accuracy of CBCT in measuring the tooth lengths of only single rooted premolar teeth [21[21] Adarsh K, Sharma P, Juneja A. Accuracy and reliability of tooth length measurements on conventional and CBCT images: An in vitro comparative study. J Orthodont Sci 2018; 7:17. https://doi.org/10.4103/jos.JOS_21_18
https://doi.org/10.4103/jos.JOS_21_18...
], hence in the present study the molar teeth length were analyzed.

In the present study, in comparison with actual lengths, OPG lengths were relatively inaccurate, overestimating by 12.11% and 7.67% in mandibular molars and premolars followed by maxillary premolars (37.91%) and for maxillary molar-palatal (17.79%) and maxillary molar-buccal (20.16%) measurements. The CBCT images underestimated the lengths by 2.31% in mandibular premolars but overestimated the lengths in mandibular molar (3.93%), maxillary premolars (5.51%) and for maxillary molar-palatal (7.48 %) and maxillary molar-buccal (4.29%) measurements. It has been observed that CBCT underestimated tooth length by 1.2% and panoramic radiographs underestimated tooth length by an average of 3.9% [21[21] Adarsh K, Sharma P, Juneja A. Accuracy and reliability of tooth length measurements on conventional and CBCT images: An in vitro comparative study. J Orthodont Sci 2018; 7:17. https://doi.org/10.4103/jos.JOS_21_18
https://doi.org/10.4103/jos.JOS_21_18...
]. A previous study demonstrated that tooth lengths were 29% overestimated on OPG images overestimated the tooth and underestimated by 4% on CBCT panoramic reconstructed images [2[2] Flores-Mir C, Rosenblatt MR, Major PW, Carey JP, Heo G. Measurement accuracy and reliability of tooth length on conventional and CBCT reconstructed panoramic radiographs. Dental Press J Orthod 2014; 19(5):45-53. https://doi.org/10.1590/2176-9451.19.5.045-053.oar
https://doi.org/10.1590/2176-9451.19.5.0...
]. These differences may be due to different CBCT device used and the difference in the methodology. Some researchers carried out an in-vitro comparative study by using NewTom Giano Extra-Oral CBCT Imaging System and KODAK 8000C Digital Panoramic and Cephalometric device [21[21] Adarsh K, Sharma P, Juneja A. Accuracy and reliability of tooth length measurements on conventional and CBCT images: An in vitro comparative study. J Orthodont Sci 2018; 7:17. https://doi.org/10.4103/jos.JOS_21_18
https://doi.org/10.4103/jos.JOS_21_18...
]. A previous study used 12-bit i-CAT CBCT imaging system and the conventional panoramic radiographs with an Instrumentarium Orthopantomograph OP100 which were later digitized and evaluated [2[2] Flores-Mir C, Rosenblatt MR, Major PW, Carey JP, Heo G. Measurement accuracy and reliability of tooth length on conventional and CBCT reconstructed panoramic radiographs. Dental Press J Orthod 2014; 19(5):45-53. https://doi.org/10.1590/2176-9451.19.5.045-053.oar
https://doi.org/10.1590/2176-9451.19.5.0...
].

In the present study, even though the tooth length measured from CBCT images showed a statistically significant difference from actual tooth lengths, these images provided improved clarity and accuracy compared to the measurements obtained from conventional panoramic images.

Conclusion

CBCT images exhibited accuracy over panoramic images even though the measurements are still significantly different from actual anatomical tooth lengths.

  • Financial Support: This study was funded by the Jouf University, Kingdom of Saudi Arabia, Research Project No. 134/39.

References

  • [1]
    Pretty IA, Sweet D. A look at forensic dentistry - Part 1: The role of teeth in the determination of human identity. Br Dent J 2001; 190(7):359-66. https://doi.org/10.1038/sj.bdj.4800972a
    » https://doi.org/10.1038/sj.bdj.4800972a
  • [2]
    Flores-Mir C, Rosenblatt MR, Major PW, Carey JP, Heo G. Measurement accuracy and reliability of tooth length on conventional and CBCT reconstructed panoramic radiographs. Dental Press J Orthod 2014; 19(5):45-53. https://doi.org/10.1590/2176-9451.19.5.045-053.oar
    » https://doi.org/10.1590/2176-9451.19.5.045-053.oar
  • [3]
    Sameshima GT, Asgarifar KO. Assessment of root resorption and root shape: Periapical vs panoramic films. Angle Orthod 2001; 71(3):185-89.
  • [4]
    Rushton VE, Horner K. The use of panoramic radiology in dental practice. J Dent 1996; 24:185-201. https://doi.org/10.1016/0300-5712(95)00055-0
    » https://doi.org/10.1016/0300-5712(95)00055-0
  • [5]
    Ezoddini Ardakani F, Zangouie Booshehri M, Behniafar B. Evaluation of the distortion rate of panoramic and periapical radiographs in erupted third molar inclination. Iran J Radiol 2011; 8:15-21.
  • [6]
    Molander B. Panoramic radiography in dental diagnostics. Swed Dent J 1996; 119(Suppl):1-26.
  • [7]
    Persson RE, Tzannetou S, Feloutzis AG, Brägger U, Persson GR, Lang NP. Comparison between panoramic and intra-oral radiographs for the assessment of alveolar bone levels in a periodontal maintenance population. J Clin Periodontol 2003; 30(9):833-9. https://doi.org/10.1034/j.1600-051X.2003.00379.x
    » https://doi.org/10.1034/j.1600-051X.2003.00379.x
  • [8]
    Hassan BA. Reliability of periapical radiographs and orthopantomograms in detection of tooth root protrusion in the maxillary sinus: Correlation results with cone beam computed tomography. J Oral Maxillofac Res 2010; 1(1):e6. https://doi.org/10.5037/jomr.2010.1106
    » https://doi.org/10.5037/jomr.2010.1106
  • [9]
    Patil SR, Ghani HA, Almuhaiza M, Al-Zoubi IA, Anil KN, Misra N, Raghuram P H. Prevalence of pulp stones in a Saudi Arabian subpopulation: A cone-beam computed tomography study. Saudi Endod J 2018; 8:93-8. https://doi.org/10.4103/sej.sej_32_17
    » https://doi.org/10.4103/sej.sej_32_17
  • [10]
    Patil SR, Araki K, Ghani HA, Al-Zoubi IA, Sghaireen MG, Gudipaneni RK, et al. A cone beam computed tomography study of the prevalence of pulp stones in a Saudi Arabian adolescent population. Pesqui Bras Odontopediatria Clín Integr 2018; 18(1):e3973. https://doi.org/10.4034/PBOCI.2018.181.45
    » https://doi.org/10.4034/PBOCI.2018.181.45
  • [11]
    Sinha N, Singh B, Patil S. Cone beam computed topographic evaluation of a central incisor with an open apex and a failed root canal treatment using one-step apexification with Biodentine™: A case report. J Conserv Dent 2014; 17:285-9. https://doi.org/10.4103/0972-0707.131805
    » https://doi.org/10.4103/0972-0707.131805
  • [12]
    Al-Zoubi IA, Patil SR, Takeuchi K, Misra N, Ohno Y, Sugita Y, Maeda H, Alam MK. Analysis of the length and types of root trunk and length of root in human first and second molars and to the actual measurements with the 3D CBCT. J Hard Tissue Biol 2018; 27(1):39-42. https://doi.org/10.2485/jhtb.27.39
    » https://doi.org/10.2485/jhtb.27.39
  • [13]
    Alam MK, Alhabib S, Alzarea BK, Irshad M, Faruqi S, Sghaireen MG, et al. 3D CBCT morphometric assessment of mental foramen in Arabic population and global comparison: Imperative for invasive and non-invasive procedures in mandible. Acta Odontol Scand 2018; 76(2):98-104. https://doi.org/10.1080/00016357.2017.1387813
    » https://doi.org/10.1080/00016357.2017.1387813
  • [14]
    Patil SR, Alam MK, Moriyama K, Matsuda S, Shoumura M, Osuga N. 3D CBCT assessment of soft tissue calcification. J Hard Tissue Biol 2017; 26(3):297-300. https://doi.org/10.2485/jhtb.26.297
    » https://doi.org/10.2485/jhtb.26.297
  • [15]
    Al-Zoubi IA, Patil SR, Kato I, Sugita Y, Maeda H, MK. 3D CBCT Assessment of incidental maxillary sinus abnormalities in a Saudi Arabian population. J Hard Tissue Biol 2017; 26:369-72. https://doi.org/10.2485/jhtb.26.369
    » https://doi.org/10.2485/jhtb.26.369
  • [16]
    Patil SR, Araki K, Yadav N, Ghani HA. Prevalence of hypercementosis in a Saudi Arabian population: A cone beam computed tomography study. J Oral Res 2018; 7(3):94-7. https://doi.org/10.17126/JORALRES.2018.022
    » https://doi.org/10.17126/JORALRES.2018.022
  • [17]
    Patil SR, Maragathavalli G, Araki K, Al-Zoubi IA, Sghaireen MG, Gudipaneni RK, et al. Three-rooted mandibular first molars in a Saudi Arabian population: A CBCT study. Pesqui Bras Odontopediatria Clín Integr 2018; 18(1):e4133. https://doi.org/10.4034/PBOCI.2018.181.87
    » https://doi.org/10.4034/PBOCI.2018.181.87
  • [18]
    Patil SR, Raghuram PH, Munisekhar MS, Shailaja G, Gudipanen RK, Alam MK. CBCT evaluation of an unusual case of florid cemento osseous dysplasia in an old female. Int Med J 2018; 25(5):335-6.
  • [19]
    Lascala CA, Panella J, Marques MM. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-newTom). Dentomaxillofac Radiol 2004; 33(5):291-4. https://doi.org/10.1259/dmfr/25500850
    » https://doi.org/10.1259/dmfr/25500850
  • [20]
    Lagravère MO, Carey J, Toogood RW, Major PW. Three-dimensional accuracy of measurements made with software on cone-beam computed tomography images. Am J Orthod Dentofacial Orthop 2008; 134(1):112-6. https://doi.org/10.1016/j.ajodo.2006.08.024
    » https://doi.org/10.1016/j.ajodo.2006.08.024
  • [21]
    Adarsh K, Sharma P, Juneja A. Accuracy and reliability of tooth length measurements on conventional and CBCT images: An in vitro comparative study. J Orthodont Sci 2018; 7:17. https://doi.org/10.4103/jos.JOS_21_18
    » https://doi.org/10.4103/jos.JOS_21_18

Edited by

Academic Editors: Alessandro Leite Cavalcanti and Wilton Wilney Nascimento Padilha

Publication Dates

  • Publication in this collection
    10 Oct 2019
  • Date of issue
    2019

History

  • Received
    04 Jan 2019
  • Accepted
    28 Jan 2019
  • Published
    31 Jan 2019
Associação de Apoio à Pesquisa em Saúde Bucal Avenida Epitácio Pessoa, 4161 - Sala 06, Miramar, CEP: 58020-388, João Pessoa, PB - Brasil, Tel.: 55-83-98773 2150 - João Pessoa - PB - Brazil
E-mail: apesb@terra.com.br