Correlation of the epidural space measured intraoperatively and estimated by MRI or US: an observational study

Abstract

Background and objectives:

To assess the agreement between the epidural depth measured from the surgical site with the epidural depths estimated with magnetic resonance imaging (MRI) and ultrasound scanning.

Methods:

Fifty patients of either sex, scheduled for L4‒5 lumbar disc surgery under general anesthesia were enrolled in this prospective observational study, and the results of 49 patients were analyzed. The actual epidural depth was measured from the surgical site with a sterile surgical scale. The MRI-derived epidural depth was measured from the MRI scan. The ultrasound estimated epidural depth was measured from the ultrasound image obtained just before surgery.

Results:

The mean epidural depth measured from the surgical site was 53.80 ± 7.67 mm, the mean MRI-derived epidural depth was 54.06 ± 7.36 mm, and the ultrasound-estimated epidural depth was 53.77 ± 7.94 mm. The correlation between the epidural depth measured from the surgical site and MRI-derived epidural depth was 0.989 (r2 = 0.979, p < 0.001), and the corresponding correlation with the ultrasound-estimated epidural depth was 0.990 (r2 = 0.980, p < 0.001).

Conclusions:

Both ultrasound-estimated epidural depth and MRI-derived epidural depth have a strong correlation with the epidural depth measured from the surgical site. Preprocedural MRI-derived estimates of epidural depth are slightly deeper than the epidural depth measured from the surgical site, and the ultrasound estimated epidural depths are somewhat shallower. Although both radiologic imaging techniques provided reliable preprocedural estimates of the actual epidural depth, the loss of resistance technique cannot be discarded while inserting epidural needles.

KEYWORDS
Epidural; Anesthesia; Ultrasound; Magnetic resonance imaging; Intraoperative

Resumo

Justificativa e objetivos:

Avaliar a concordância entre a profundidade peridural medida no campo cirúrgico com a profundidade peridural estimada pela Ressonância Magnética (RM) e ultrassonografia.

Métodos:

Cinquenta pacientes de ambos os sexos agendados para cirurgia de disco lombar L4-5 sob anestesia geral foram incluídos neste estudo observacional prospectivo, e os resultados de 49 pacientes foram analisados. A profundidade peridural real foi medida no campo cirúrgico com uma régua cirúrgica estéril. A profundidade peridural obtida pela Ressonância Magnética (RM) foi medida a partir das imagens do exame de RM. A profundidade peridural estimada pelo ultrassom foi medida a partir da imagem do ultrassom obtida imediatamente antes da cirurgia.

Resultados:

A profundidade peridural média medida no campo cirúrgico foi de 53,80 ± 7,67 mm; a profundidade peridural média da RM foi de 54,06 ± 7,36 mm; e a profundidade peridural estimada por ultrassom foi de 53,77 ± 7,94 mm. A correlação entre a profundidade peridural medida no campo cirúrgico e a profundidade peridural derivada da RM foi de 0,989 (r2 = 0,979; p < 0,001); e a correlação correspondente com a profundidade peridural estimada por ultrassom foi de 0,990 (r2 = 0,980; p < 0,001).

Conclusões:

Tanto a profundidade peridural estimada por ultrassom quanto a profundidade peridural derivada da RM mostram forte correlação com a profundidade peridural medida no campo cirúrgico. As estimativas pré-operatórias da profundidade peridural derivadas da RM são um pouco mais profundas do que a profundidade peridural medida no campo cirúrgico, e as profundidades peridurais estimadas por ultrassom são um pouco mais rasas. Embora ambas as técnicas de imagem radiológica tenham fornecido estimativas pré-operatórias confiáveis da profundidade peridural real, a técnica de perda de resistência não pode ser descartada durante a inserção da agulha peridural.

PALAVRAS-CHAVE
Peridural; Anestesia; Ultrassonografia; Ressonância magnética; Intraoperatório

Introduction

Neuraxial anesthesia is technically challenging but has well established intraoperative and postoperative benefits.11 Bomberg H, Paquet N, Huth A, et al. Epidural needle insertion: a large registry analysis. Anaesthesist. 2018;67:922-30.,22 Popping DM, Elia N, Van Aken HK, et al. Impact of epidural analgesia on mortality and morbidity after surgery: systematic review and meta-analysis of randomized controlled trials. Ann Surg. 2014;259:1056-67.

Neuraxial procedures necessitate due diligence since they are routinely performed with a so-called “blind technique”. The success rate of precisely identifying the epidural space depends on the accuracy of the clinican sensing the loss of resistance. The inaccurate identification of epidural depth is not trivial among novices and may result in failed regional anesthesia, inadvertent dural puncture, paresthesia, and epidural hematoma.33 Bouman EA, Gramke HF, Wetzel N, et al. Evaluation of two different epidural catheters in clinical practice. Narrowing down the incidence of paresthesia!. Acta Anaesthesiol Belg. 2007;58:101-5.

4 Dalsasso M, Grandis M, Innocente F, et al. A survey of 1000 consecutive epidural catheter placements performed by inexperienced anesthesia trainees. Minerva Anestesiol. 2009;75:13-9.

5 Kang XH, Bao FP, Xiong XX, et al. Major complications of epidural anesthesia: a prospective study of 5083 cases at a single hospital. Acta Anaesthesiol Scand. 2014;58:858-66.

6 Shih CK, Wang FY, Shieh CF, et al. Soft catheters reduce the risk of intravascular cannulation during epidural block — a retrospective analysis of 1,117 cases in a medical center. Kaohsiung J Med Sci. 2012;28:373-6.
-77 Tanaka K, Watanabe R, Harada T, et al. Extensive application of epidural anesthesia and analgesia in a university hospital: incidence of complications related to technique. Reg Anesth. 1993;18:34-8.

Preprocedural information of epidural depth may facilitate epidural insertion and increase the safety of the procedure. Previous studies assessed the agreement between the actual epidural depth and radiologic estimates of epidural depth measured with computed tomography, Magnetic Resonance Imaging (ED/MRI), and Ultrasonography (ED/US) in a variety of patient populations with varying age groups to provide a reliable estimate of the epidural depth.88 Algrain H, Liu A, Singh S, et al. Cervical epidural depth: correlation between cervical MRI measurements of the skin-to-cervical epidural space and the actual needle depth during interlaminar cervical epidural injections. Pain Med. 2018;19:1015-22.

9 Canturk M, Karbancioglu Canturk F, Kocaoglu N, et al. Abdominal girth has a strong correlation with ultrasound-estimated epidural depth in parturients: a prospective observational study. J Anesth. 2019;33(2):273-8.

10 Carnie J, Boden J, Gao Smith F. Prediction by computerised tomography of distance from skin to epidural space during thoracic epidural insertion. Anaesthesia. 2002;57:701-4.

11 Franklin AD, Lorinc AN, Shotwell MS, et al. Evaluation of the skin to epidural and subarachnoid space distance in young children using magnetic resonance imaging. Reg Anesth Pain Med. 2015;40:245-8.

12 Jones JH, Singh N, Nidecker A, et al. Assessing the agreement between radiologic and clinical measurements of lumbar and cervical epidural depths in patients undergoing prone interlaminar epidural steroid injection. Anesth Analg. 2017;124:1678-85.
-1313 Lee HJ, Min JY, Kim HI, et al. Measuring the depth of the caudal epidural space to prevent dural sac puncture during caudal block in children. Paediatr Anaesth. 2017;27:540-4.

Former studies assessing the correlation between the actual epidural depth with those measured with ED/US and ED/MRI were retrospective in nature, and the “actual epidural depth” was defined as the epidural needle depth.88 Algrain H, Liu A, Singh S, et al. Cervical epidural depth: correlation between cervical MRI measurements of the skin-to-cervical epidural space and the actual needle depth during interlaminar cervical epidural injections. Pain Med. 2018;19:1015-22.,1212 Jones JH, Singh N, Nidecker A, et al. Assessing the agreement between radiologic and clinical measurements of lumbar and cervical epidural depths in patients undergoing prone interlaminar epidural steroid injection. Anesth Analg. 2017;124:1678-85.,1313 Lee HJ, Min JY, Kim HI, et al. Measuring the depth of the caudal epidural space to prevent dural sac puncture during caudal block in children. Paediatr Anaesth. 2017;27:540-4. To the best of our knowledge, our study is unique in that we identified the “actual epidural depth” as the “Epidural Depth measured from the surgical site” (ED/AC), and the study is prospectively designed.

The primary outcomes of the present study were determining the ED/US. The secondary outcomes of the study were to determine ED/MRI and ED/AC.

In the present study, ED/AC was assessed for its agreement with ED/US and ED/MRI. We hypothesized that both ED/US and ED/MRI are in strong agreement with ED/AC.

Methods

This prospective observational study on patients scheduled for lumbar herniated disc surgery at the L4‒5 level with general anesthesia was conducted from 31 May 2018 to 31 August 2018 to assess the agreement among ED/AC, ED/US and ED/MRI. Written informed consent was obtained from all patients. The study was prepared following the Declaration of Helsinki and Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) guidelines (Fig. 1).

Figure 1
STROBE Checklist.

After obtaining approval from the ethical committee (2017-20/244, 26/12/2017) and institutional review board (13389610/449, 19/01/2018), the study was prospectively registered in the Australian New Zealand Clinical Trials Registry (ACTRN12618000552280, 13/04/2018).

Patients with American Society of Anesthesiologists physical status (ASA-PS) I ‒III who were aged 18‒75 years and scheduled for lumbar herniated disc surgery at the L4‒5 level with general anesthesia were included in the study. Patients with neurological diseases, vertebral column anomalies, history of previous spine or spinal canal surgeries, and ASA-PS > III, patients aged younger than 18 years or older than 75 years, and patients pregnant or lactating were excluded.

The majority of herniated lumbar discs occur at the L4‒5 and L5‒S1 levels.1414 Jordan J, Konstantinou K, O’Dowd J. Herniated lumbar disc. BMJ Clin Evid. 2009;2009. One of the treatment modalities for lumbar herniated disc to improve the functional status of the patient is surgical treatment.1515 Nelson AM, Nagpal G. Interventional approaches to low back pain. Clin Spine Surg. 2018;31:188-96. In the present study, we included patients who underwent surgery for a herniated lumbar disc at the L4‒5 level.

The rationale for choosing a study group composed of patients scheduled for herniated disc surgery was that they readily had lumbar MRI scans, and surgical site ED/AC measurements were possible during the operation.

Ultrasound measurements

The patients received electrocardiogram, pulse oximeter, and noninvasive blood pressure monitoring on arrival to the operating room. General anesthesia was induced with intravenous 2‒2.5 mg.kg-1 propofol and 2 mcg.kg-1 fentanyl. Muscle relaxation was achieved with intravenous rocuronium 1.5 mg.kg-1. Maintenance of anesthesia was achieved with 2% Sevoflurane in a 50% air/oxygen mixture with 4 L.min-1 fresh gas flow. After securing the airway, the patients were placed in a prone position.

The ultrasound examination was performed in the paramedian sagittal oblique plane with a 2‒5 MHz curved array probe (Esaote Mylab30, Florence, Italy) before surgical draping was performed in the prone position. The paramedian sagittal oblique plane was formerly reported to provide optimal window for ultrasound scanning.1616 Grau T, Leipold RW, Horter J, et al. Paramedian access to the epidural space: the optimum window for ultrasound imaging. J Clin Anesth. 2001;13:213-7. All ultrasound scanning was performed by the same investigator (MC) with more than five years of experience in vertebral sonoanatomy who was blinded to the ED/MRI measurements. First, the hyperechoic continuous line of the sacrum was identified in the midline. The probe was placed 2‒3 cm lateral to the midline in sagittal axis and tilted to provide the paramedian sagittal oblique view of the vertebral canal. After achieving visualization of the saw-tooth-like appearance, the L4‒5 interspace was located in the center of the probe. The screen was frozen to measure the ED/US. The distance from the skin to the posterior border of the ligamentum flavum was accepted as the ED/US and measured in millimeters with the built-in caliper of the ultrasound device.

MRI measurements

All patients underwent MRI scanning of the lumbar vertebra within 30 days before the surgery, following the standard protocol of the neurosurgery clinics in our institution. MRI scanning was performed in the supine position. All MRI measurements were acquired by the same investigator (NK, trained for lumbar epidural depth measurements by a neuroradiologist) at the L4‒5 level. NK was blinded for the ED/US measurements. MRI scans were selected from the T2‒weighted sagittal images stored in the picture achieving and communication system (PACS, GE Healthcare Co.) of the hospital to measure the ED/MRI. The distance from the skin to the posterior border of the ligamentum flavum, measured in the horizontal plane was accepted as the ED/MRI and was recorded for further statistical analysis. Measurements were acquired in millimeters with the built-in caliper of the PACS system.

Surgical site epidural depth measurements

After positioning the patient for surgery, the patients back was prepared aseptically and covered with surgical drapes. Following the skin incision and surgical dissection, ligamentum flavum was exposed. The position of the patient was then turned to supine in the horizontal plane. The actual epidural depth was measured in the horizontal prone position, rather than in the surgical flexed position, which could affect the distance from the skin to the ligamentum flavum. The surgeon used a sterile surgical scale to measure the distance from the skin to the posterior border of the ligamentum flavum in millimeters. This distance was accepted as the actual Epidural Depth (ED/AC).

Statistical analysis

The data were analyzed for normality with the Shapiro-Wilk test. The normally distributed data were expressed as the mean ± Standard Deviation (SD). Categorical variables are presented as percentages. Pearson’s correlation and Lin’s concordance correlation1717 Crawford SB, Kosinski AS, Lin HM, et al. Computer programs for the concordance correlation coefficient. Comput Methods Programs Biomed. 2007;88:62-74.,1818 Lin L, Torbeck LD. Coefficient of accuracy and concordance correlation coefficient: new statistics for methods comparison. PDA J Pharm Sci Technol. 1998;52:55-9. were used to analyze the agreement among ED/AC, ED/US, and ED/MRI. A Bland-Altman plot was used to analyze the accuracy among the measurements. One-sample t-test was used to compare mean differences. The mean differences among measurements were calculated by subtracting ED/US or ED/MRI from ED/AC and dividing by two. The mean values of the measurements were calculated by summing of ED/US or ED/MRI with ED/AC and dividing by two. The mean differences in measurements were graphically plotted against the mean sums of measurements on a Bland-Altman diagram1919 Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-10.,2020 Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135-60. that presented the 95% limits of agreement among ED/AC, ED/US, and ED/MRI.

The sample size of the study was calculated by using data obtained from the preliminary results of the study with G*Power 3.1.9.2. Minimum required sample size (n) was 50 to detect a desired statistical power level of 0.80 and p-value = 0.05.

Results

We enrolled fifty patients in this prospective observational study. One patient withdrew his consent to participate in the study, and the results of 49 patients were considered for analysis. Mean age of the patients was 47.61 ± 13.92 years, and the mean height was 167.27 ± 8.67 cm. Mean patient weight was 82.11 ± 12.58 kg. The mean Body Mass Index (BMI) was 29.51 ± 5.18 kg.m-2. The distribution of patients according to ASA-PS was as follows: 19 patients with ASA-OS I, 22 patients with ASA-PS II, and eight patients with ASA-PS III. Twenty-five patients were female, and 24 were male. The mean ED/AC was 53.80 ± 7.67 mm, the mean ED/US was 53.77 ± 7.94 mm, and the mean ED/MRI was 54.06 ± 7.36 mm (Table 1).

Table 1
Patient characteristics.

The Pearson correlation coefficient between ED/AC and ED/US was 0.990 (r2 = 0.980, p < 0.001). The concordance correlation coefficient between ED/AC and ED/US was 0.990 (95% CI 0.982-0.994). The Pearson correlation coefficient between ED/AC and ED/MRI was 0.989 (r2 = 0.979, p < 0.001). The concordance correlation coefficient between ED/AC and ED/MRI was 0.975 (95% CI 0.958-0.985). Pearson correlation and Lin’s concordance correlation plots are presented in Figs. 2 and 3 respectively.

Figure 2
Pearson’s correlation plots. (a) The correlation between the actual Epidural Depth (ED/AC) and the Eltrasound estimated Epidural Depth (ED/US); r2, coefficient of determination. (b) The correlation between the Actual Epidural Depth (ED/AC) and the Magnetic Resonance Imaging derived Epidural Depth (ED/MRI); r2, coefficient of determination.

Figure 3
Lin’s concordance correlation plots. (a) The correlation between the actual Epidural Depth (ED/AC) and the Ultrasond estimated Epidural Depth (ED/US); r2, coefficient of determination. (b) The correlation between the actual Epidural Depth (ED/AC) and the Magnetic Resonance Imaging derived Epidural Depth (ED/MRI); r2, coefficient of determination.

The mean difference between ED/US and ED/AC was -0.36 ± 1.13 mm (95% limits of agreement: -2.52-1.91). The mean difference between ED/MRI and ED/AC was 0.26 ± 1.14 mm (95 limits of agreement: -1.97-2.49). The mean difference in the epidural depth was plotted against the mean sum of epidural depth measurements on a Bland-Altman diagram representing the upper and lower 95% limits of agreement of the ED/AC with ED/US and ED/MRI (Fig. 4).

Figure 4
Bland-Altman plots. (a) The Bland-Altman plot representing the agreement between the actual epidural depth and the ultrasound estimated epidural depth (ED/US, Ultrasound Estimated Skin to Epidural Depth; ED/AC, Actual Epidural Depth measured from the surgical site. (b) The Bland-Altman plot representing the agreement between the actual epidural depth and the magnetic resonance imaging derived epidural depth (ED/MRI, Magnetic Resonance Imaging derived skin to Epidural Depth; ED/AC, Actual Epidural Depth Measured from the surgical site.

Discussion

We assessed the correlation of ED/AC with ED/US and ED/MRI in patients scheduled for lumbar disc surgery under general anesthesia. We demonstrated a strong correlation between ED/AC and ED/US, which was also consistent between ED/AC and ED/MRI.

The precise identification of the epidural space determines if the procedure will be a success or failure. The identification of the epidural space with the loss of resistance technique depends mainly on the clinician performing the epidural. Preprocedural knowledge of the depth of the ligamentum flavum may facilitate the precise location of the epidural space, providing the safe distance for epidural needle advancement.

The correlations between epidural space depth and patient characteristics were analyzed in previous studies. A mathematical formula was derived to predict epidural depth.88 Algrain H, Liu A, Singh S, et al. Cervical epidural depth: correlation between cervical MRI measurements of the skin-to-cervical epidural space and the actual needle depth during interlaminar cervical epidural injections. Pain Med. 2018;19:1015-22.,99 Canturk M, Karbancioglu Canturk F, Kocaoglu N, et al. Abdominal girth has a strong correlation with ultrasound-estimated epidural depth in parturients: a prospective observational study. J Anesth. 2019;33(2):273-8.,1111 Franklin AD, Lorinc AN, Shotwell MS, et al. Evaluation of the skin to epidural and subarachnoid space distance in young children using magnetic resonance imaging. Reg Anesth Pain Med. 2015;40:245-8.,1313 Lee HJ, Min JY, Kim HI, et al. Measuring the depth of the caudal epidural space to prevent dural sac puncture during caudal block in children. Paediatr Anaesth. 2017;27:540-4. These earlier works were undertaken to facilitate the epidural insertion as well as to prevent the inadvertent complications of the procedure. The agreement between the actual epidural depth and radiologic measurements was assessed to predict the epidural depth.99 Canturk M, Karbancioglu Canturk F, Kocaoglu N, et al. Abdominal girth has a strong correlation with ultrasound-estimated epidural depth in parturients: a prospective observational study. J Anesth. 2019;33(2):273-8.

10 Carnie J, Boden J, Gao Smith F. Prediction by computerised tomography of distance from skin to epidural space during thoracic epidural insertion. Anaesthesia. 2002;57:701-4.

11 Franklin AD, Lorinc AN, Shotwell MS, et al. Evaluation of the skin to epidural and subarachnoid space distance in young children using magnetic resonance imaging. Reg Anesth Pain Med. 2015;40:245-8.
-1212 Jones JH, Singh N, Nidecker A, et al. Assessing the agreement between radiologic and clinical measurements of lumbar and cervical epidural depths in patients undergoing prone interlaminar epidural steroid injection. Anesth Analg. 2017;124:1678-85.,2121 Arzola C, Davies S, Rofaeel A, et al. Ultrasound using the transverse approach to the lumbar spine provides reliable landmarks for labor epidurals. Anesth Analg. 2007;104:1188-92.

22 Balki M, Lee Y, Halpern S, et al. Ultrasound imaging of the lumbar spine in the transverse plane: the correlation between estimated and actual depth to the epidural space in obese parturients. Anesth Analg. 2009;108:1876-81.
-2323 Helayel PE, da Conceicao DB, Meurer G, et al. Evaluating the depth of the epidural space with the use of ultrasound. Rev Bras Anestesiol. 2010;60:376-82.

Daniel et al.2424 Daniel M, Doyon D, Bekkali F, et al. MRI of normal spinal epidural fat. J Radiol. 1992;73:695-8. reported that there were variations in the deposition of epidural fat along the vertebral column that alter the anterior-posterior diameter of the epidural space. Other than the study published by Jones et al.,1212 Jones JH, Singh N, Nidecker A, et al. Assessing the agreement between radiologic and clinical measurements of lumbar and cervical epidural depths in patients undergoing prone interlaminar epidural steroid injection. Anesth Analg. 2017;124:1678-85. other previous studies defined the epidural depth as the distance from the skin to the anterior border of the ligamentum flavum-posterior dura complex.1111 Franklin AD, Lorinc AN, Shotwell MS, et al. Evaluation of the skin to epidural and subarachnoid space distance in young children using magnetic resonance imaging. Reg Anesth Pain Med. 2015;40:245-8.,2525 Aldrete JA, Mushin AU, Zapata JC, et al. Skin to cervical epidural space distances as read from magnetic resonance imaging films: consideration of the “hump pad”. J Clin Anesth. 1998;10:309-13. In the present study, we described the epidural depth as the distance from the skin to the posterior border of the ligamentum flavum.

To the best of our knowledge, all previous investigators accepted the epidural needle depth as the gold standard. Our study is unique because the “gold standard epidural depth” was measured from the surgical site (ED/AC) by the surgeon, and defined as the distance from the skin to the ligamentum flavum.

Although there was a strong agreement between ED/AC and ED/US, ED/US was shorter than ED/AC in our study, which was in agreement with previous studies.99 Canturk M, Karbancioglu Canturk F, Kocaoglu N, et al. Abdominal girth has a strong correlation with ultrasound-estimated epidural depth in parturients: a prospective observational study. J Anesth. 2019;33(2):273-8.,2121 Arzola C, Davies S, Rofaeel A, et al. Ultrasound using the transverse approach to the lumbar spine provides reliable landmarks for labor epidurals. Anesth Analg. 2007;104:1188-92.,2222 Balki M, Lee Y, Halpern S, et al. Ultrasound imaging of the lumbar spine in the transverse plane: the correlation between estimated and actual depth to the epidural space in obese parturients. Anesth Analg. 2009;108:1876-81. Both ED/AC and ED/US measurements were acquired in the prone position. The compression applied to the probe can explain the difference between ED/US and ED/AC. The pressure applied to the ultrasound probe squeezes the soft tissue underneath the skin, leading to a shorter epidural depth measurement. However, ED/AC was measured from the skin to the ligamentum flavum without soft tissue compression.

ED/AC was also in strong agreement with ED/MRI; however, the ED/MRI measurements were deeper than the ED/AC measurements in our study. Patients lie in the supine position during MRI scan, and the skin to epidural depth distance is compressed by the patient’s body weight. Therefore it is expected that the ED/MRI measurements would be shallower than the ED/AC measurements. Previous investigators have reported similar differences in epidural depth measurements between ED/MRI and ED/AC.88 Algrain H, Liu A, Singh S, et al. Cervical epidural depth: correlation between cervical MRI measurements of the skin-to-cervical epidural space and the actual needle depth during interlaminar cervical epidural injections. Pain Med. 2018;19:1015-22.,1212 Jones JH, Singh N, Nidecker A, et al. Assessing the agreement between radiologic and clinical measurements of lumbar and cervical epidural depths in patients undergoing prone interlaminar epidural steroid injection. Anesth Analg. 2017;124:1678-85. It is difficult to explain the deeper epidural depth measurements with MRI. However, the spinal curvature contributr to the extended epidural depth with MRI.

We demonstrated a strong positive correlation between ED/AC and ED/US, showing that when there is an increase in the actual epidural depth the ultrasound estimated epidural depth also increases. This is also consistent between ED/AC and ED/MRI.

The limits of agreement between ED/AC and ED/US were clinically very close to the limits of agreement between ED/AC and ED/MRI. Therefore both epidural depth measurement techniques can be used interchangeably while inserting epidural needles. Although ED/MRI and ED/US are in strong agreement when predicting ED/AC, we recommend that ED/US is more reliable and easy to acquire for novices. Moreover, we suggest that sensing the loss of resistance cannot be ruled out even with preprocedural knowledge of the epidural depth.

A critical limitation of the present study was that the supine position of the patient during the MRI scan was different from the position of the patient at the time of ED/AC and ED/US measurements. Further studies with larger sample sizes are warranted to validate our results.

Summary

Although ED/MRI and ED/US have a strong correlation and are in agreement with ED/AC, the loss of resistance technique should not be excluded while performing epidurals. Estimating the epidural depth with ultrasound is more appropriate in operating rooms with today’s technology. The developments in radiologic monitoring systems may provide more precise and accurate measurements of epidural depth.

  • Funding
    The authors declare no funding sources for the present study.

References

  • 1
    Bomberg H, Paquet N, Huth A, et al. Epidural needle insertion: a large registry analysis. Anaesthesist. 2018;67:922-30.
  • 2
    Popping DM, Elia N, Van Aken HK, et al. Impact of epidural analgesia on mortality and morbidity after surgery: systematic review and meta-analysis of randomized controlled trials. Ann Surg. 2014;259:1056-67.
  • 3
    Bouman EA, Gramke HF, Wetzel N, et al. Evaluation of two different epidural catheters in clinical practice. Narrowing down the incidence of paresthesia!. Acta Anaesthesiol Belg. 2007;58:101-5.
  • 4
    Dalsasso M, Grandis M, Innocente F, et al. A survey of 1000 consecutive epidural catheter placements performed by inexperienced anesthesia trainees. Minerva Anestesiol. 2009;75:13-9.
  • 5
    Kang XH, Bao FP, Xiong XX, et al. Major complications of epidural anesthesia: a prospective study of 5083 cases at a single hospital. Acta Anaesthesiol Scand. 2014;58:858-66.
  • 6
    Shih CK, Wang FY, Shieh CF, et al. Soft catheters reduce the risk of intravascular cannulation during epidural block — a retrospective analysis of 1,117 cases in a medical center. Kaohsiung J Med Sci. 2012;28:373-6.
  • 7
    Tanaka K, Watanabe R, Harada T, et al. Extensive application of epidural anesthesia and analgesia in a university hospital: incidence of complications related to technique. Reg Anesth. 1993;18:34-8.
  • 8
    Algrain H, Liu A, Singh S, et al. Cervical epidural depth: correlation between cervical MRI measurements of the skin-to-cervical epidural space and the actual needle depth during interlaminar cervical epidural injections. Pain Med. 2018;19:1015-22.
  • 9
    Canturk M, Karbancioglu Canturk F, Kocaoglu N, et al. Abdominal girth has a strong correlation with ultrasound-estimated epidural depth in parturients: a prospective observational study. J Anesth. 2019;33(2):273-8.
  • 10
    Carnie J, Boden J, Gao Smith F. Prediction by computerised tomography of distance from skin to epidural space during thoracic epidural insertion. Anaesthesia. 2002;57:701-4.
  • 11
    Franklin AD, Lorinc AN, Shotwell MS, et al. Evaluation of the skin to epidural and subarachnoid space distance in young children using magnetic resonance imaging. Reg Anesth Pain Med. 2015;40:245-8.
  • 12
    Jones JH, Singh N, Nidecker A, et al. Assessing the agreement between radiologic and clinical measurements of lumbar and cervical epidural depths in patients undergoing prone interlaminar epidural steroid injection. Anesth Analg. 2017;124:1678-85.
  • 13
    Lee HJ, Min JY, Kim HI, et al. Measuring the depth of the caudal epidural space to prevent dural sac puncture during caudal block in children. Paediatr Anaesth. 2017;27:540-4.
  • 14
    Jordan J, Konstantinou K, O’Dowd J. Herniated lumbar disc. BMJ Clin Evid. 2009;2009.
  • 15
    Nelson AM, Nagpal G. Interventional approaches to low back pain. Clin Spine Surg. 2018;31:188-96.
  • 16
    Grau T, Leipold RW, Horter J, et al. Paramedian access to the epidural space: the optimum window for ultrasound imaging. J Clin Anesth. 2001;13:213-7.
  • 17
    Crawford SB, Kosinski AS, Lin HM, et al. Computer programs for the concordance correlation coefficient. Comput Methods Programs Biomed. 2007;88:62-74.
  • 18
    Lin L, Torbeck LD. Coefficient of accuracy and concordance correlation coefficient: new statistics for methods comparison. PDA J Pharm Sci Technol. 1998;52:55-9.
  • 19
    Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-10.
  • 20
    Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135-60.
  • 21
    Arzola C, Davies S, Rofaeel A, et al. Ultrasound using the transverse approach to the lumbar spine provides reliable landmarks for labor epidurals. Anesth Analg. 2007;104:1188-92.
  • 22
    Balki M, Lee Y, Halpern S, et al. Ultrasound imaging of the lumbar spine in the transverse plane: the correlation between estimated and actual depth to the epidural space in obese parturients. Anesth Analg. 2009;108:1876-81.
  • 23
    Helayel PE, da Conceicao DB, Meurer G, et al. Evaluating the depth of the epidural space with the use of ultrasound. Rev Bras Anestesiol. 2010;60:376-82.
  • 24
    Daniel M, Doyon D, Bekkali F, et al. MRI of normal spinal epidural fat. J Radiol. 1992;73:695-8.
  • 25
    Aldrete JA, Mushin AU, Zapata JC, et al. Skin to cervical epidural space distances as read from magnetic resonance imaging films: consideration of the “hump pad”. J Clin Anesth. 1998;10:309-13.

Publication Dates

  • Publication in this collection
    14 Sept 2020
  • Date of issue
    May-Jun 2020

History

  • Received
    3 Apr 2019
  • Accepted
    22 Mar 2020
Sociedade Brasileira de Anestesiologia R. Professor Alfredo Gomes, 36, 22251-080 Botafogo RJ Brasil, Tel: +55 21 2537-8100, Fax: +55 21 2537-8188 - Campinas - SP - Brazil
E-mail: bjan@sbahq.org