Revista Brasileira de Cardiologia Invasiva, Volume: 20, Número: 2, Publicado: 2012
  • Tratamento de bifurcações coronárias: simplifique, mas não exagere Editoriais

    Chaves, Áurea J.
  • Pré-dilatação em lesão de bifurcação coronária: devemos aderir ao reducionismo de Einstein? Editoriais

    Buysschaert, Ian; Verheye, Stefan
  • O sirolimus é um fármaco conhecido para o stent farmacológico, mas é um novo fármaco para o balão farmacológico Editoriais

    Nakagawa, Kaori; Ikeno, Fumiaki
  • Impacto da pré-dilatação do ramo lateral no procedimento de intervenção coronária percutânea em lesões de bifurcação coronária complexas Artigos Originais

    Costa, Ricardo A.; Feres, Fausto; Staico, Rodolfo; Costa Jr., J. Ribamar; Siqueira, Dimytri; Tanajura, Luiz F.; Abizaid, Alexandre; Sousa, Amanda G. M. R.; Sousa, J. Eduardo; Colombo, Antonio

    Resumo em Português:

    INTRODUÇÃO: O tratamento de lesões de bifurcação com implante de stent único no vaso principal e stent provisional no ramo lateral pode ser limitado pelo grau de complexidade anatômica/morfológica da lesão. A pré-dilatação do ramo lateral, um passo do procedimento geralmente evitado, pode ser necessária para manter a patência do ramo lateral. Investigamos o impacto da pré-dilatação do ramo lateral nos resultados imediatos de intervenção coronária percutânea em lesões de bifurcação coronária complexas. MÉTODOS: Entre maio de 2008 e agosto de 2009, 59 pacientes com lesão de bifurcação coronária única e comprometimento significativo de vaso principal e ramo lateral foram incluídos no estudo. Os principais critérios de exclusão foram: envolvimento do tronco de coronária esquerda, infarto agudo do miocárdio com elevação do segmento ST (< 72 horas) e reestenose intrastent. RESULTADOS: A média de idade foi de 61,2 ± 11 anos, 25,4% eram do sexo feminino e 30,1% tinham diabetes. As lesões mais frequentemente se localizaram em artéria descendente anterior/ramo diagonal (86,4%). Durante o procedimento, 8,5% (5/59) das lesões tiveram pré-dilatação do ramo lateral sem sucesso, e 4 dessas bifurcações foram tratadas com 2 stents. No modelo multivariado, a estenose do ramo lateral no pré-procedimento foi o único preditor significativo de pré-dilatação sem sucesso do ramo lateral (odds ratio 1,15, intervalo de confiança de 95% 1,01-1,30; P = 0,04), e estenose > 87,6% no ramo lateral foi identificada na curva ROC como valor de corte com maior acurácia para predizer o insucesso. CONCLUSÕES: A pré-dilatação do ramo lateral esteve associada a falência imediata do ramo lateral em < 10% dos casos e o único preditor significativo na análise multivariada foi a gravidade da estenose (> 85%) no ramo lateral no pré-procedimento.

    Resumo em Inglês:

    BACKGROUND: The treatment of coronary bifurcation lesions with single stenting in the main vessel and provisional side branch stenting may be limited by the degree of anatomical/morphological complexity. Side branch predilation, a procedural step usually avoided, may be required to maintain side branch patency. We investigated the impact of side branch predilation on the immediate results of percutaneous coronary intervention in complex coronary bifurcation lesions. METHODS: Between May 2008 and August 2009, 59 patients with single coronary bifurcation lesions with significant involvement of the main and side branches were included in the study. The main exclusion criteria were: involvement of the left main coronary artery, ST-elevation acute myocardial infarction (< 72 hours) and in-stent restenosis. RESULTS: Mean age was 61.2 ± 11 years, 25.4% were female and 30.1% had diabetes mellitus. Lesions were most prevalent in the left anterior descending artery/diagonal branch (86.4%). During procedure, 8.5% (5/59) of lesions had unsuccessful side branch predilation, and 4 of these bifurcations were treated with 2 stents. In the multivariate model, side branch stenosis at baseline was the only significant predictor of unsuccessful side branch predilation (odds ratio 1.15, 95% confidence interval 1.01-1.30; P = 0.04), and side branch stenosis > 87.6% was identified as the most accurate cut-off value to predict failure in the ROC curve. CONCLUSIONS: Side branch predilation was associated with immediate side branch failure in < 10% of cases, and the only significant predictor in the multivariate model was the severity of side branch stenosis (> 85%) at baseline.
  • Estudo da dose excipiente: fármaco com avaliação da hiperplasia neointimal por tomografia de coerência óptica e histopatologia em artérias coronárias porcinas após o emprego do balão eluidor de sirolimus Artigos Originais

    Takimura, Celso Kiyochi; Galon, Micheli Zanotti; Sojitra, Prakash; Doshi, Manish; Aiello, Vera; Gutierrez, Paulo Sampaio; Carvalho, Juliana; Ferreira, Suzane Kiss; Chaves, Marcio Jose Figueira; Laurindo, Francisco Rafael Martins; Lemos, Pedro Alves

    Resumo em Português:

    INTRODUÇÃO: Magic TouchTM é um balão recoberto com nanopartículas carreadoras de sirolimus. Objetivamos encontrar a dose excipiente:fármaco com a maior capacidade de inibição da proliferação neointimal 28 dias após o uso desse balão pós-implante de stent não-farmacológico em artérias coronárias porcinas. MÉTODOS: Foram avaliados 14 porcos com implante coronário de stent não-farmacológico seguido por dilatação (60 segundos) com balões com relação excipiente:sirolimus 1:1, 0,5:1, 0,25:1 e 1:0 ou balão controle. Após 28 dias a hiperplasia neointimal foi estudada por tomografia de coerência óptica e histopatologia. RESULTADOS: A hiperplasia neointimal porcentual (%) avaliada pela tomografia de coerência óptica e pela histomorfometria foi de 32,2 e 35,1, 28,1 e 33,4, 17,3 e 20,9, 28,6 e 30,2, e 37,9 e 42,3 nos grupos excipiente:sirolimus 0,25:1, 0,5:1, 1:1, 1:0 e balão controle, respectivamente (P = 0,03 para excipiente:sirolimus 1:1 vs. balão controle). A espessura (mm) da neoíntima inter-hastes foi de 0,23, 0,30, 0,16, 0,24 e 0,30 nos grupos excipiente:sirolimus 0,25:1, 0,5:1, 1:1, 1:0 e balão controle, respectivamente (P < 0,01 para excipiente:sirolimus 1:1 vs. balão controle). Os escores de inflamação, injúria e deposição de fibrina foram baixos e sem diferenças significantes entre os grupos. CONCLUSÕES: Ocorreu gradual aumento da eficácia inibitória da proliferação neointimal à medida que a concentração do excipiente aumentou; a menor eficácia ocorreu com a formulação excipiente:sirolimus 0,25:1 e a mais intensa inibição foi observada com a formulação excipiente:sirolimus 1:1, a qual reduziu significantemente a proliferação neointimal em comparação com o grupo controle, com baixos índices de inflamação e injúria.

    Resumo em Inglês:

    BACKGROUND: Magic TouchTM is a sirolimus based nano carrier balloon. We aimed at finding the excipient:drug ratio with the highest capacity to inhibit neointimal proliferation 28 days after the use of this balloon after bare metal stenting in porcine coronary arteries. METHODS: Fourteen domestic pigs with coronary bare metal stenting followed by dilation (60 seconds) using balloons with an excipient:sirolimus ratio of 1:1, 0.5:1, 0.25:1, 1:0 or a control balloon were evaluated. After 28 days neointimal hyperplasia was assessed by optical coherence tomography and histopathology. RESULTS: Percent neointimal hyperplasia (%) assessed by optical coherence tomography and histomorphometry was 32.2 and 35.1, 28.1 and 33.4, 17.3 and 20.9, 28.6 and 30.2, and 37.9 and 42.3 in the groups with 0.25:1, 0.5:1, 1:1, 1:0 excipient:sirolimus ratios and control balloon, respectively (P = 0.03 for excipient:sirolimus 1:1 versus control balloon). The neointimal interstrut thickness (mm) was 0.23, 0.30, 0.16, 0.24 and 0.30 in the groups with 0.25:1, 0.5:1, 1:1, 1:0 excipient:sirolimus ratios and control balloon, respectively (P < 0.01 for excipient:sirolimus 1:1 versus control balloon). The scores of inflammation, injury and fibrin deposition were low and there was no significant difference among groups. CONCLUSIONS: There was a stepwise increase in inhibitory efficacy of neointimal proliferation as the excipient concentration increased; the lowest efficacy was observed with the 0.25:1 excipient:sirolimus formulation and the most intensive inhibition was observed with the 1:1 excipient:sirolimus formulation. The 1:1 excipient:sirolimus formulation significantly reduced neointimal proliferation when compared to the control group, with low inflammation and injury scores.
  • Identificação de genes envolvidos na síntese de proteínas de células musculares lisas com expressão aumentada em placas ateromatosas associados a hiperplasia neointimal após implante de stents não-farmacológicos: estudo GENESIS-R Artigos Originais

    Zago, Alexandre C.; Costa, Marco A.; Zago, Alcides J.; Rossato, Juliane S.; Matte, Bruno S.; Iturry-Yamamoto, German; Mossmann, Márcio; Savaris, Ricardo; Albertal, Mariano; Rocha, Cristiane S.; Healy, Aileen M.; Walker, Russell; Tahara, Satoko; Simon, Daniel I.

    Resumo em Português:

    INTRODUÇÃO: A reestenose coronária é um fenômeno pouco compreendido e que permanece como um desafio mesmo na era dos stents farmacológicos. Este estudo tem como objetivo identificar genes envolvidos na síntese de proteínas estruturais e funcionais de células musculares lisas com expressão aumentada em placas ateromatosas de humanos associados a hiperplasia neointimal após o implante de stents não-farmacológicos. MÉTODOS: Placas ateromatosas foram obtidas mediante aterectomia direcionada, previamente ao implante do stent. A análise da expressão dos genes foi realizada utilizando-se o sistema Affymetrix GeneChip. Os pacientes foram submetidos a ultrassom intracoronário 6 meses após o procedimento para análise volumétrica intrastent. Foi avaliada a correlação entre a expressão gênica de placas ateromatosas e o porcentual de hiperplasia intimal intrastent. RESULTADOS: A maioria dos pacientes era do sexo masculino (85,7%), com 60,2 ± 11,4 anos de idade, 35,7% eram diabéticos e o porcentual de hiperplasia intimal intrastent foi de 29,9 ± 18,7%. Não houve variação do porcentual de hiperplasia intimal intrastent entre os pacientes com ou sem diabetes (29,5% vs. 30,7%; P = 0,89). Não houve correlação entre a extensão do stent e o porcentual de hiperplasia intimal intrastent (r = -0,26; P = 0,26) ou entre o diâmetro do stent e o porcentual de hiperplasia intimal intrastent (r = 0,14; P = 0,56). Oito genes envolvidos na síntese de proteínas estruturais e funcionais de células musculares lisas apresentaram correlação positiva com o porcentual de hiperplasia intimal intrastent. CONCLUSÕES: As lesões coronárias de novo apresentam expressão aumentada de genes relacionados com a síntese de proteínas estruturais e funcionais de células musculares lisas associados a futura hiperplasia neointimal intrastent significativa, surgindo como novos alvos terapêuticos.

    Resumo em Inglês:

    BACKGROUND: Coronary restenosis is a poorly understood phenomenon that remains a challenge even in the drug-eluting stent era. This study is aimed at identifying the genes involved in structural and functional protein synthesis of smooth muscle cells with increased expression in human atheromatous plaques associated to neointimal hyperplasia after bare-metal stent implantation. METHODS: Atheromatous plaques were obtained by directional atherectomy prior to stenting. Gene expression analysis was performed using the Affymetrix GeneChip system. Patients were submitted to intravascular ultrasound 6 months after the procedure for in-stent volumetric analysis. We evaluated the correlation between gene expression in atheromatous plaques and the percentage of in-stent intimal hyperplasia. RESULTS: Most patients were male (85.7%), with 60.2 ± 11.4 years of age, 35.7% were diabetic and the percentage of in-stent intimal hyperplasia was 29.9 ± 18.7%. There was no change in the percentage of in-stent intimal hyperplasia in patients with or without diabetes (29.5% vs. 30.7%; P = 0.89). There was no correlation between stent length and the percentage of in-stent intimal hyperplasia (r = -0.26; P = 0.26) or between stent diameter and the percentage of in-stent intimal hyperplasia (r = 0.14; P = 0.56). Eight genes related to smooth muscle cell structural and functional protein synthesis had a positive correlation with the percentage of in-stent intimal hyperplasia. CONCLUSIONS: De novo coronary lesions show increased expression of genes related to smooth muscle cell structural and functional protein synthesis associated to future significant in-stent neointimal hyperplasia, emerging as novel therapeutic targets.
  • Seguimento angiográfico e clínico tardio do novo stent farmacológico não-polimérico liberador de paclitaxel para o tratamento de lesões coronárias de novo: resultados do estudo PAX-B Artigos Originais

    Abreu-Silva, Erlon O. de; Costa, Ricardo A.; Abizaid, Andrea; Ramondo, Angelo; Brenot, Philippe; Benamer, Hakim; Desideri, Alessandro; Berland, Jacques; Almeida, Breno O.; Digne, Franck; Perin, Marco A.; Castro, Juliana P. de; Costa Jr., J. Ribamar; Staico, Rodolfo; Tanajura, Luiz F.; Abizaid, Alexandre

    Resumo em Português:

    INTRODUÇÃO: O stent farmacológico eluidor de paclitaxel, não-polimérico, Amazonia® PAX não mostrou diferença na reestenose coronária ou eventos clínicos aos 4 meses de evolução quando comparado com o stent Taxus®. Entretanto, o desempenho do stent Amazonia® PAX em cenários de maior complexidade e com seguimento angiográfico mais longo ainda não foi demonstrado. MÉTODOS: O Estudo PAX-B foi um estudo prospectivo, não-randomizado, multicêntrico, que avaliou os resultados tardios de pacientes tratados com o stent Amazonia® PAX. O desfecho primário foi a perda tardia do lúmen intrastent. RESULTADOS: Foram incluídos 103 pacientescom média de idade de 61,3 ± 11,4 anos, 26,2% eram diabéticos, 24,3% apresentaram-se com síndrome coronária aguda e 71,6% tinham lesões tipo B2/C. Implante de múltiplos stents ocorreu em 4,7% dos casos e o sucesso angiográfico foi de 100%. Na fase hospitalar, a taxa de infarto agudo do miocárdio periprocedimento foi de 3,9%, e um desses eventos levou à revascularização da lesão-alvo (RLA). No seguimento angiográfico de 9 meses, a mediana da perda tardia do lúmen intrastent foi de 0,91 [0,50; 1,21] mm. As taxas cumulativas de eventos cardíacos adversos maiores nos seguimentos de 6 meses, 9 meses e 12 meses foram, respectivamente, de 7,8%, 18,5% e 21,3%, principalmente em decorrência de RLA. Não se observou morte ou trombose de stent em 12 meses. CONCLUSÕES: O stent Amazonia® PAX demonstrou excelentes resultados imediatos e alto perfil de segurança. Entretanto, as taxas de recorrência angiográfica foram relativamente altas, em razão da pouca eficácia na inibição da formação de hiperplasia neointimal.

    Resumo em Inglês:

    BACKGROUND: The non-polymeric paclitaxel-eluting sent Amazonia® PAX did not show differences in the occurrence of coronary restenosis or clinical events after 4 months of follow-up when compared with the Taxus® stent. However, the performance of the Amazonia® PAX stent in more complex cases and with longer angiographic follow-up has not been demonstrated. METHODS: The PAX-B study was a prospective, non-randomized, multicenter study assessing the late follow-up of patients treated with the Amazonia® PAX stent. The primary outcome was in-stent late lumen loss. RESULTS: One hundred and three patients with mean age of 61.3 ± 11.4 years were included, 26.2% were diabetics, 24.3% had acute coronary syndromes and 71.6% had type B2/C lesions. Multiple stents were performed in 4.7% of the cases and angiographic success was 100%. During hospitalization, the periprocedural acute myocardial infarction rate was 3.9% and one of these events led to target lesion revascularization (TLR). At 9-month angiographic follow-up, the median in-stent late lumen loss was 0.91 [0.50; 1.21] mm. The cumulative rates of major adverse cardiac events at the 6-month, 9-month and 12-month follow-up were 7.8%, 18.5% and 21.3%, respectively, mostly due to TLR. There was no death or stent thrombosis at 12 months. CONCLUSIONS: The stent Amazonia® PAX demonstrated excellent immediate results and high safety profile. However, angiographic recurrence rates were relatively high, due to low efficacy in inhibition of neointimal hyperplasia.
  • Fondaparinux em intervenção coronária percutânea no tratamento da síndrome coronária aguda Artigos Originais

    Andrade, Pedro Beraldo de; Tebet, Marden André; Nogueira, Ederlon Ferreira; Andrade, Mônica Vieira Athanazio de; Barbosa, Robson Alves; Labrunie, André; Mattos, Luiz Alberto

    Resumo em Português:

    INTRODUÇÃO: Considerado um fármaco com adequado perfil de eficácia e segurança no tratamento da síndrome coronária aguda sem supradesnivelamento do segmento ST, o fondaparinux, utilizado de forma isolada, associa-se a maior ocorrência de complicações trombóticas durante a realização de procedimentos coronários invasivos, requerendo a adição de agente com atividade anti-IIa. Este estudo teve como objetivo avaliar a eficácia e a segurança da intervenção coronária percutânea (ICP) em pacientes admitidos com diagnóstico de síndrome coronária aguda sem supradesnivelamento do segmento ST, previamente tratados com fondaparinux. MÉTODOS: Registro prospectivo, controlado, envolvendo 127 pacientes consecutivos submetidos a estratificação invasiva precoce na vigência de fondaparinux, com suplementação de heparina não-fracionada intravenosa na dose de 85 U/kg no momento da ICP. RESULTADOS: A taxa do desfecho primário, composto por morte, infarto agudo do miocárdio, acidente vascular encefálico, trombose de stent ou revascularização miocárdica de urgência, foi de 3,2%. A incidência acumulada de sangramento grave e complicações vasculares foi de 3,2%. Não houve casos de trombose do cateter-guia ou oclusão abrupta do vaso. CONCLUSÕES: A ICP em pacientes com síndrome coronária aguda em uso de fondaparinux associa-se a baixas taxas de eventos cardiovasculares adversos isquêmicos e de complicações hemorrágicas graves. A suplementação com heparina não-fracionada durante o procedimento invasivo elimina o risco de trombose do cateter.

    Resumo em Inglês:

    BACKGROUND: Fondaparinux is considered an agent with a well-established safety and efficacy profile in the treatment of non-ST segment elevation acute coronary syndromes, but when used alone, is associated to a higher incidence of thrombotic complications during invasive coronary procedures, requiring the supplementation of an anti-IIa agent. This study aimed to evaluate the efficacy and safety of percutaneous coronary intervention (PCI) in patients with non-ST segment elevation acute coronary syndromes previously treated with fondaparinux. METHODS: Prospective, controlled registry enrolling 127 consecutive patients submitted to an early invasive stratification during treatment with fondaparinux, with supplementation of intravenous unfractionated heparin at a dose of 85 U/kg at the time of PCI. RESULTS: The rate of the composite primary endpoint including death, acute myocardial infarction, stroke, stent thrombosis or emergency myocardial revascularization was 3.2%. The cumulative incidence of major bleeding and vascular complications was 3.2%. There were no cases of guide-catheter thrombosis or abrupt vessel closure. CONCLUSIONS: PCI in patients with acute coronary syndromes receiving fondaparinux is associated with a low rate of major adverse cardiovascular ischemic events and severe hemorrhagic complications. Supplementation of unfractionated heparin during the invasive procedures eliminates the risk of catheter-related thrombosis.
  • Prognóstico tardio em jovens com coronariopatia estável: evolução em 10 anos após intervenção coronária percutânea Artigos Originais

    Bienert, Igor Ribeiro de Castro; Ribeiro, Expedito E.; Kajita, Luiz J.; Perin, Marco Antonio; Campos, Carlos A. H.; Trentin, Fabio; Lemos, Pedro Alves

    Resumo em Português:

    INTRODUÇÃO: Atualmente são ainda desconhecidas as implicações prognósticas tardias da doença arterial coronária (DAC) estável em pacientes jovens. O objetivo deste trabalho foi avaliar o prognóstico de pacientes adultos jovens com diagnóstico de DAC estável, tratados por meio de intervenção coronária percutânea (ICP) e acompanhados por até 10 anos. MÉTODOS: A população do estudo foi constituída por pacientes jovens (idade abaixo do 10o percentil) de um grupo de 1.394 pacientes consecutivos tratados para DAC estável por via percutânea. As características dos pacientes foram coletadas prospectivamente. Após o procedimento foi realizado seguimento ambulatorial, com análise do prontuário hospitalar eletrônico e contato telefônico, quando necessário. O desfecho primário foi a mortalidade geral e o desfecho secundário, a mortalidade cardiovascular. RESULTADOS: Foram selecionados 140 pacientes, com média de idade de 43,7 ± 4 anos (mínimo de 26 anos e máximo de 48 anos), predominantemente do sexo masculino (76,4%). Diabetes melito estava presente em aproximadamente um quinto dos pacientes e metade apresentava infarto prévio. Os pacientes foram seguidos por uma média de 94,6 ± 36,2 meses e a mortalidade geral no seguimento de 10 anos foi de 6%, com mortalidade cardíaca de 5,3%. Todos os pacientes que morreram obtiveram sucesso no procedimento inicial e apenas um dos casos não apresentava infarto prévio. CONCLUSÕES: Em nossa prática clínica, pacientes jovens com coronariopatia crônica tratados com ICP mostraram ter bom prognóstico tardio.

    Resumo em Inglês:

    BACKGROUND: The late prognostic implications of stable coronary artery disease (CAD) in young patients are currently unknown. The objective of this study was to evaluate the prognosis of young adult patients diagnosed with stable CAD, treated by percutaneous coronary intervention (PCI) and followed-up for 10 years. METHODS: The study population consisted of young patients (age below the 10th percentile) of a group of 1,394 consecutive patients treated for stable CAD using the percutaneous approach. Patient characteristics were collected prospectively. After the procedure outpatient follow-up was performed, including the analysis of the electronic medical records and telephone contact, whenever required. The primary outcome was overall mortality and the secondary outcome was cardiovascular mortality. RESULTS: One hundred and forty patients were selected, with mean age of 43.7 ± 4 years (ranging from 26 to 48 years) and were predominantly males (76.4%). Diabetes mellitus was present in approximately one fifth of patients and half of them had a previous myocardial infarction. Patients were followed for an average of 94.6 ± 36.2 months and the overall mortality after 10 years was 6%, with cardiac mortality of 5.3%. All of the patients who died had a successful index procedure and only one of the cases did not have a previous myocardial infarction. CONCLUSIONS: In our clinical practice, young patients with chronic CAD treated by PCI demonstrated a good late prognosis.
  • Resultados hospitalares da intervenção coronária percutânea em diabéticos Artigos Originais

    Coelho, Leonardo dos Santos; Cantarelli, Marcelo José de Carvalho; Castello Junior, Hélio José; Gonçalves, Rosaly; Gioppato, Silvio; Ribeiro, Evandro Karlo Pracchia; Guimarães, João Batista de Freitas; Vardi, Julio César Francisco; Silva, Patricia Teixeira da; Almeida, Roberto Simões de; Ganassin, Fabio Peixoto; Farinazzo, Marcelo Mendes

    Resumo em Português:

    INTRODUÇÃO: Poucas publicações estão disponíveis na literatura avaliando a evolução hospitalar de pacientes diabéticos submetidos a intervenção coronária percutânea (ICP) na era contemporânea. Nosso objetivo foi avaliar os resultados agudos pós-ICP de uma grande série de pacientes diabéticos e não-diabéticos, tratados consecutivamente. MÉTODOS: No período de agosto de 2006 a fevereiro de 2012, 6.011 pacientes foram submetidos a ICP e incluídos no Registro do Hospital Bandeirantes. A técnica e a escolha do material durante o procedimento ficaram a cargo dos operadores. Os desfechos clínicos foram registrados no momento da alta hospitalar. RESULTADOS: Os diabéticos mostraram ser mais idosos, mais frequentemente do sexo feminino, com maior prevalência de comorbidades e fatores de risco para doença arterial coronária, à exceção do tabagismo. A maioria das características de complexidade das lesões, no entanto, não diferiu entre os grupos. Nos diabéticos, o número de vasos tratados (1,6 ± 0,8 vs. 1,4 ± 0,7; P < 0,01) foi maior e o uso de stents de menor calibre (2,9 ± 0,5 mm vs. 3 ± 0,5 mm; P < 0,01) foi mais frequente. Taxa de sucesso do procedimento de 95,5% foi alcançada nos dois grupos. Os desfechos hospitalares não mostraram diferenças quanto à incidência de eventos cardíacos e cerebrovasculares adversos maiores (3,3% vs. 2,8%; P = 0,79), óbito (1% vs. 1,1%; P = 0,90), infarto agudo do miocárdio (2% vs. 2,4%; P = 0,35), acidente vascular cerebral (0,1% em ambos os grupos), e revascularização de emergência (0,3% em ambos os grupos). Hipertensão arterial foi a variável que melhor explicou a ocorrência de eventos cardíacos e cerebrovasculares adversos maiores [odds ratio (OR) 2,68, intervalo de confiança de 95% (IC 95%) 1,13-6,38; P = 0,026). CONCLUSÕES: O diabetes agrega maior complexidade clínica à ICP, sem modificar, entretanto, os desfechos clínicos hospitalares.

    Resumo em Inglês:

    BACKGROUND: There are few reports available in the literature assessing in-hospital outcomes of diabetic patients undergoing contemporary percutaneous coronary intervention (PCI). Our objective was to assess the acute post-PCI outcomes of a large series of diabetic and non-diabetic patients treated consecutively. METHODS: From August 2006 to February 2012, 6,011 patients were submitted to PCI and were included in Hospital Bandeirantes Registry. The technique and devices for the procedure were chosen by the operators. Clinical outcomes were recorded at the time of hospital discharge. RESULTS: Diabetic patients were older and more often female, with a higher prevalence of comorbidities and risk factors for coronary artery disease, except for smoking. However, most of the characteristics related to lesion complexity did not differ between groups. In diabetics, the number of treated vessels (1.6 ± 0.8 vs. 1.4 ± 0.7; P < 0.01) was higher and the use of smaller stents (2.9 ± 0.5 mm vs. 3 ± 0.5 mm; P < 0,01) was more frequent. Procedural success rate of 95.5% was achieved in both groups. In-hospital outcomes did not differ regarding the incidence of major adverse cardiac and cerebrovascular events (3.3% vs. 2.8%; P = 0.79), death (1% vs. 1.1%; P = 0.90), acute myocardial infarction (2% vs. 2.4%; P = 0.35), stroke (0.1% in both groups), and emergency revascularization (0.3% in both groups). Hypertension was the variable that best explained the occurrence of major adverse cardiac and cerebrovascular events [odds ratio (OR) 2.68, 95% confidence interval (95% CI) 1.13-6.38; P = 0.026). CONCLUSIONS: Diabetes adds more clinical complexity to PCI, but has no significant impact on in-hospital outcomes.
  • Lesões ostiais em artérias coronárias principais tratadas com técnica de Szabo Artigos Originais

    Maiello, Paulo Cícero Aidar; Osterne, Ernesto Misael Cintra; Pimentel Filho, Wilson Albino; Custódio, Wellington Borges; Pupin Filho, Waigner Bento; Petrucci, Fábio Soares; Nunes, Cássio dos Santos; Sada, Carlos Alberto; Lambert, Gustavo Vinicius; Büchler, Jorge Roberto; Assis, Stoessel Figueredo de; Armelin, Egas

    Resumo em Português:

    INTRODUÇÃO: A intervenção coronária percutânea (ICP) em lesões ostiais é um dos maiores desafios para a cardiologia intervencionista contemporânea. A despeito dos avanços tecnológicos, as lesões ostiais ainda apresentam maiores taxas de eventos adversos imediatos e tardios quando comparadas às lesões não-ostiais. O objetivo deste estudo foi avaliar a ICP em lesões ostiais, utilizando a técnica de Szabo. MÉTODOS: Série de 10 pacientes, incluídos entre outubro e novembro de 2011, tratados por meio de ICP utilizando a técnica de Szabo em lesões ostiais em ramos coronários principais. Não foram abordadas lesões aorto-ostiais. RESULTADOS: Dos 10 pacientes tratados, 7 eram do sexo masculino, com idade variando entre 42 anos e 75 anos, e 60% apresentavam síndrome coronária aguda sem supradesnivelamento do segmento ST. Artéria circunflexa foi tratada em 6 pacientes e cateter 7 F foi utilizado em 8 pacientes. Em 3 pacientes não se observou progressão do stent em decorrência de torção das cordas-guia, que foi resolvida com o recuo parcial da corda-guia direcionada para a lesão-alvo e novo posicionamento. Houve sucesso do procedimento em 90% dos casos. Não ocorreram óbitos, (re)infartos ou revascularizações de urgência hospitalares. CONCLUSÕES: Neste estudo, a técnica de Szabo permitiu tratar lesões ostiais em ramos principais das artérias coronárias com sucesso, posicionando o stent de maneira adequada na maioria dos casos.

    Resumo em Inglês:

    BACKGROUND:Percutaneous coronary intervention (PCI) in ostial lesions is one of the major challenges for contemporary interventional cardiology. Despite the technological advances, ostial lesions still present a higher rate of immediate and late adverse events when compared to non-ostial lesions. The objective of this study was to evaluate coronary ostial lesions treated with the Szabo technique. METHODS: Series of 10 patients, included between October and November 2011, treated by PCI using the Szabo technique to treat ostial lesions in main coronary arteries. Aorto-ostial lesions were excluded. RESULTS: Of the 10 patients treated, 7 were male, with ages ranging from 42 to 75 years and 60% had acute coronary syndromes without ST-segment elevation. The circumflex artery was treated in 6 patients and a 7 F catheter was used in 8 patients. In 3 patients, during the advancement of the stent to the lesion, both guidewires twisted, which was solved by partially retrieving the standard target vessel wire and positioning it again. Procedural success was observed in 90% of the cases. There were no hospital deaths, (re)infarctions or emergency revascularizations. CONCLUSIONS: In this study, the Szabo technique successfully treated ostial lesions in main coronary arteries, providing adequate positioning of the stent in most of the cases.
  • Associação entre saúde bucal e doença arterial coronária aterosclerótica em pacientes submetidos a cineangiocoronariografia: estudo transversal controlado Artigos Originais

    Zanella, Silvia Maria; Souza, Lucas Vieira de; Suzigan, Bruna Helena; Saba-Chujfi, Eduardo; Barbisan, Juarez Neuhaus

    Resumo em Português:

    INTRODUÇÃO: Doenças cardiovasculares e periodontais são condições inflamatórias comuns na população. Na aterosclerose, a condição inflamatória tem papel contínuo no desenvolvimento, desestabilização e ruptura da placa do ateroma. Existe evidência científica controversa em relação à associação entre periodontite crônica e doença arterial coronária (DAC). O objetivo do estudo foi verificar a associação entre periodontite crônica e DAC em nosso meio. MÉTODOS: Estudo transversal controlado, com amostra de 206 pacientes sem DAC prévia e com indicação clínica de cineangiocoronariografia, submetidos a anamnese, exame físico e coleta de sangue para verificação de glicemia, perfil lipídico e proteína C-reativa. A presença de periodontite crônica foi determinada por exame clínico realizado por periodontista, buscando avaliar quantidade de placa bacteriana, cálculos gengivais, sangramento, exsudato e sinais clássicos de inflamação. RESULTADOS: A média de idade foi de 60,3 ± 10,1 anos e 60,2% eram do sexo masculino. DAC esteve presente em 126 pacientes (61,2%). Houve associação da presença de DAC com gênero [sexo masculino, odds ratio (OR) 2,18; P = 0,0075], idade (61-70 anos, OR 5,63; P = 0,0007) e escolaridade (ensino superior, OR 2,08; P = 0,02). Os biomarcadores inflamatórios não diferiram entre os grupos com e sem DAC. Sinais inflamatórios e placa bacteriana ocorreram em 88% dos pacientes com DAC, índice ligeiramente superior ao observado naqueles sem DAC. Má saúde bucal, representada por perda de dentes, foi mais prevalente nos pacientes com DAC. O número de dentes faltantes foi de 14 ± 6,4 e de 11,9 ± 6,7 (P = 0,04) nos pacientes com e sem DAC, respectivamente. CONCLUSÕES: Há associação entre saúde bucal comprometida e DAC.

    Resumo em Inglês:

    BACKGROUND: Cardiovascular and periodontal diseases are common inflammatory conditions. In atherosclerosis, inflammation plays a continuous role in the development, destabilization and rupture of atheromas. There is controversial scientific evidence regarding the association between chronic periodontitis and coronary artery disease (CAD). The objective of this study was to assess the association between chronic periodontitis and CAD in our practice. METHODS: Cross-sectional controlled study including 206 patients without prior CAD and with a clinical indication for coronary angiography, undergoing history, physical examination and blood sample collection to test blood glucose, lipid profile and C-reactive protein. The presence of chronic periodontitis was determined by clinical examination performed by a periodontist, evaluating the amount of bacterial plaque, gingival calculus, bleeding, exudate and classical signs of inflammation. RESULTS: Mean age was 60.3 + 10.1 years and 60.2% were males. CAD was present in 126 patients (61.2%). There was an association of CAD with gender [male gender, odds ratio (OR) 2.18; P = 0.0075], age (61-70 years, OR 5.63; P = 0.0007) and education (higher education, OR 2.08; P = 0.02). Inflammatory biomarkers did not differ between the groups with and without CAD. Signs of inflammation and bacterial plaque were present in 88% of patients with CAD, slightly higher than the rate found in patients without CAD. Poor oral health, represented by loss of teeth, was more prevalent in patients with CAD. The number of missing teeth was 14 + 6.4 and 11.9 + 6.7 (P = 0.04) in patients with and without CAD, respectively. CONCLUSIONS: There is an association between poor oral health and CAD.
  • Tratamento endovascular da dissecção crônica de aorta tipo B complicada Artigos Originais

    Metzger, Patrick Bastos; Fontes, Deo Cesar Carneiro; Novero, Eduardo Rafael; Marco, Vanessa Luciene Abreu de; Moreira, Samuel Martins; Rossi, Fabio Henrique; Barbato, Heraldo Antonio; Cano, Manoel Nicolas; Izukawa, Nilo Mitsuru; Kambara, Antonio M.

    Resumo em Português:

    INTRODUÇÃO: A correção endovascular das doenças aórticas está bem estabelecida como alternativa terapêutica para pacientes com anatomia adequada e/ou alto risco cirúrgico, proporcionando menores taxas de morbidade e mortalidade. Nosso objetivo foi analisar os resultados do tratamento de pacientes assintomáticos submetidos a tratamento endovascular de dissecções de aorta torácica complicadas, seja por diâmetro aórtico > 5,5 cm ou vazamentos. Avaliamos o sucesso técnico, o sucesso terapêutico, a morbidade e a mortalidade, e as taxas de complicações perioperatórias e de reintervenções. MÉTODOS: Estudo retrospectivo, realizado em um centro de referência, no período de janeiro de 2010 a julho de 2011, em que foram analisados pacientes consecutivos submetidos a correção endovascular de dissecção crônica de aorta tipo B complicada pela classificação de Stanford. RESULTADOS: Foram tratados 26 pacientes. A média de idade foi de 56,4 ± 7 anos e 61,5% eram do sexo masculino. Os sucessos técnico e terapêutico foram de 100% e 74%, respectivamente. A mortalidade perioperatória foi de 7,6% e a taxa de mortalidade no primeiro ano de seguimento foi de 19,3%. A taxa de reintervenção foi de 15,3%. CONCLUSÕES: Em nosso estudo, o tratamento endovascular da dissecção crônica de aorta tipo B demonstrou ser um método viável e associado a aceitáveis taxas de complicações perioperatórias. As taxas de sucesso terapêutico e de reintervenções obtidas demonstram a necessidade de seguimento clínico rigoroso e atento desses pacientes.

    Resumo em Inglês:

    BACKGROUND: Endovascular repair of aortic diseases is a well-established therapeutic alternative for patients with appropriate anatomy and/or high surgical risk, providing lower morbidity and mortality rates. This study aimed at analyzing the outcomes of asymptomatic patients undergoing endovascular treatment of thoracic aortic dissections with aortic diameter > 5.5 cm or endoleaks. Technical success, therapeutic success, morbidity and mortality and perioperative complication and reintervention rates were assessed. METHODS: Retrospective study, performed at a reference center from January 2010 to July 2011, which analyzed consecutive patients undergoing endovascular repair of chronic complicated type B aortic dissection according to Stanford classification. RESULTS: Twenty-six patients were treated. Mean age was 56.4 ± 7 years and 61.5% were male. Technical and therapeutic success rates were 100% and 74%, respectively. Perioperative mortality was 7.6% and the mortality rate in the first year of follow-up was 19.3%. The reintervention rate was 15.3%. CONCLUSIONS: In our study, the endovascular treatment of chronic type B aortic dissection proved to be a feasible method with acceptable perioperative complication rates. Therapeutic success and reintervention rates demonstrated the need of a close and careful clinical follow-up of these patients.
  • Oclusão percutânea do canal arterial com a prótese Amplatzer® vascular plug II: experiência inicial em três centros de referência Artigos Originais

    Sant’Anna, Luis Otávio Campanhã; Costa, Rodrigo Nieckel da; Ribeiro, Marcelo Silva; Nascimento, Wanda Teixeira do; Pereira, Fabrício Leite; Neves, Juliana; Arrieta, Santiago Raul; Fontes, Valmir Fernandes; Pedra, Carlos Augusto Cardoso

    Resumo em Português:

    INTRODUÇÃO: As próteses convencionais disponíveis para o fechamento percutâneo da persistência do canal arterial (PCA) podem apresentar algumas limitações a seu uso, principalmente em crianças pequenas e em adultos com canais de maior diâmetro. A prótese Amplatzer® Vascular Plug II (AVP II) tem sido utilizada nesses casos com resultados animadores. Objetivamos apresentar a experiência inicial com AVP II em três centros de referência. MÉTODOS: Estudo prospectivo, com coleta de dados retrospectiva, dos pacientes submetidos a fechamento de PCA com AVP II desde 2011. Os dispositivos foram implantados sob anestesia geral por via anterógrada, exceto em um paciente. Foram avaliados aspectos técnicos, taxa de oclusão imediata e complicações. RESULTADOS: Foram selecionados 40 pacientes (67,5% do sexo feminino) com mediana de idade de 56,7 meses (6 meses a 654,7 meses) e mediana de peso de 17,3 kg (5 kg a 93 kg). Desses pacientes, 36 tinham PCA do tipo A, 3 do tipo E e 1 do tipo C. Os diâmetros médios do canal e da prótese foram de 3,7 ± 1,5 mm e de 9,4 ± 3,6 mm, respectivamente. Em 3 pacientes foi necessária a troca do dispositivo inicial por outro de diferente tamanho. Em uma paciente foi realizada tentativa de implante com 2 dispositivos, sem sucesso, a qual foi posteriormente encaminhada para correção cirúrgica. Em 5 pacientes foi observada discreta protrusão do disco para a aorta sem ocasionar gradiente pressórico significativo. Houve fluxo residual em 2 pacientes. Não ocorreram complicações significativas. CONCLUSÕES: O dispositivo AVP II é uma alternativa segura e eficaz para o tratamento de PCA, principalmente naqueles que apresentam limitações ao fechamento convencional.

    Resumo em Inglês:

    BACKGROUND: The conventional devices available for the percutaneous occlusion of patent ductus arteriosus (PDA) may present limitations, especially in small patients and in adults with larger ductus arteriosus. The Amplatzer® Vascular Plug II (AVP II) device has been used in these scenarios with promising results. This study is aimed at presenting the early experience with the AVP II device in three reference centers. METHODS: Prospective study, with retrospective data collection, of patients undergoing PDA occlusion with AVP II since 2011. The devices were implanted using the anterograde approach under general anesthesia, except for one patient. Technical aspects, immediate occlusion and complication rates were assessed. RESULTS: Forty patients (67.5% female) with median age of 56.7 months (6 months to 654.7 months) and median weight of 17.3 kg (5 kg to 93 kg) were included. Of these, 36 had type A PDA, 3 had type E PDA and 1 had type C PDA. Mean diameters of the ductus and the device were 3.7 ± 1.5 mm and 9.4 ± 3.6 mm, respectively. In 3 patients the initial device had to be replaced by another device with a different size. In one patient, an unsuccessful attempt was made to implant 2 devices. This patient was referred for surgical repair. In 5 patients a mild protrusion of the disc towards the aorta was observed, but did not cause significant pressure gradients. Residual flow was observed in 2 patients. There were no significant complications. CONCLUSIONS: The AVP II device is a safe and effective alternative for the treatment of PDA, especially in those with limitations to the conventional occlusion procedure.
  • Estudo iWONDER (Imaging WhOle vessel coroNary tree with intravascular ultrasounD and iMap® in patiEnts with acute myocaRdial infarction): racional e desenho do estudo Desenho De Estudo

    Souza, Cristiano Freitas de; Alves, Claudia Maria Rodrigues; Carvalho, Antonio Carlos; Bonfim, Alexandre Vidal; Silva, Erlon Oliveira de Abreu; P. Junior, Edilberto C.; Falcão, Felipe; Lanaro, Eduardo; Barbosa, Adriano H. P.; Souza, José Augusto M.; Sousa, José Marconi A.; Souza, Rodrigo Almeida; Rigla, Juan; Caixeta, Adriano

    Resumo em Português:

    INTRODUÇÃO: O ultrassom intracoronário (USIC) é um método capaz de fornecer medida sensível e reprodutível das dimensões da artéria coronária, da placa aterosclerótica e do lúmen arterial. Avanços em sua tecnologia permitem agora a caracterização da composição e da morfologia das placas ateroscleróticas. Embora estudos prévios tenham reportado dados utilizando USIC com análise de radiofrequência, o uso de uma nova modalidade (iMap®, Boston Scientific, Santa Clara, Estados Unidos) de caracterização da placa aterosclerótica é muito pouco conhecida. Nosso objetivo será analisar as características morfológicas, teciduais e fenotípicas das placas ateroscleróticas consideradas angiograficamente "culpadas" e "não-culpadas" em pacientes submetidos a angiografia coronária decorrente de infarto agudo do miocárdio (IAM). MÉTODOS: Estudo prospectivo, transversal, em único centro (Hospital São Paulo - Escola Paulista de Medicina - Universidade Federal de São Paulo/UNIFESP, São Paulo, SP, Brasil). Serão selecionados 50 pacientes para análise ultrassonográfica, de acordo com os seguintes critérios de inclusão: idade < 75 anos, IAM sem supradesnivelamento do segmento ST ou IAM com supradesnivelamento do segmento ST recente, com ou sem uso de fibrinolítico prévio. CONCLUSÕES: O presente estudo objetivará a caracterização morfológica, tecidual e fenotípica da placa aterosclerótica utilizando uma nova modalidade de imagem ainda pouco estudada em pacientes com IAM.

    Resumo em Inglês:

    BACKGROUND: Intravascular ultrasound (IVUS) provides a sensitive and reproducible measurement of coronary artery dimensions, atherosclerotic plaque, and arterial lumen. Advances in IVUS technology now allow the characterization of the composition and morphology of atherosclerotic plaques. Although previous studies have reported data using IVUS radiofrequency analysis, the use of a new modality (iMap®, Boston Scientific, Santa Clara, USA) of atherosclerotic plaque characterization is very little known. Our objective is to analyze the morphological, phenotypic and tissue characteristics of "culprit" and "non-culprit" atherosclerotic plaques determined by angiography in patients undergoing coronary angiography due to acute myocardial infarction (AMI). METHODS: Prospective, cross-sectional, single center study (Hospital São Paulo - Escola Paulista de Medicina - Universidade Federal de São Paulo/UNIFESP, São Paulo, SP, Brazil). Fifty patients will be selected for ultrasound analysis according to the following inclusion criteria: age < 75 years, non-ST-segment elevation AMI or recent ST-segment elevation AMI, with or without previous fribrinolytic agents. CONCLUSIONS: The present study is aimed at obtaining morphological, phenotypic and tissue characteristics of the atherosclerotic plate using an imaging modality not extensively evaluated in patients with AMI.
  • Experiência inicial com o uso do autopulse® em sala de hemodinâmica Relatos De Caso

    Vargas, Túlio Torres; Ribeiro, Philipe Leitão; Cade, Jamil Ribeiro; Dallan, Luís Augusto Palma; Janella, Bruno Laurenti; Almeida, Breno Oliveira; Spadaro, André Gasparini; Perin, Marco Antonio; Truffa, Rodrigo Augusto Meirelles; Sato, Anderson Pedro Katsuo

    Resumo em Português:

    Os autores apresentam a experiência inicial do uso de dispositivo mecânico de reanimação AutoPulse®. O dispositivo foi utilizado em caso de parada cardiorrespiratória em sala de hemodinâmica, permitindo a continuidade do procedimento percutâneo concomitantemente à ressuscitação cardiopulmonar. O dispositivo proporcionou compressões torácicas ininterruptas e efetivas, bem como liberou um médico da equipe para outras funções durante o procedimento. Houve dificuldades quanto à rapidez na instalação do dispositivo no momento da emergência e em relação à radiopacidade dos componentes eletrônicos, que impediram algumas projeções angiográficas. O uso de dispositivos mecânicos de compressões torácicas durante parada cardiorrespiratória é factível, porém ainda não há comprovação de seus benefícios em relação à ressuscitação cardiopulmonar com compressões manuais.

    Resumo em Inglês:

    The initial experience with the use of AutoPulse® Non-Invasive Cardiac Support Pump in the catheterization laboratory is reported. The device was used in a case of cardiopulmonary arrest in the catheterization laboratory, allowing the percutaneous procedure to move on with simultaneous cardiopulmonary resuscitation. The device provided uninterrupted and effective chest compressions and released a team doctor for other functions during the procedure. There were difficulties related to the setup of the device and regarding the radiopacity of the electronic components, which prevented some angiographic projections from being obtained. The use of mechanical devices for chest compressions during a cardiopulmonary arrest is feasible, however, there is no proof of its benefits when compared to cardiopulmonary resuscitation using manual compressions.
  • Técnica "mother and child" com um novo cateter: experiência inicial Relatos De Caso

    Furini, Fabio Rodrigo; Oliveira, Alessandra Teixeira de; Francisco, Rafic Sergio Bittencourt; Bassani, Ismael Arcari; Voltolini, Sara; Lima, Valter Correia de

    Resumo em Português:

    Relatamos nossa experiência inicial com o GuideLinerTM, uma extensão de cateter-guia de rápida troca tipo "child", desenvolvido para facilitar a entrega de stents e balões em intervenções arteriais percutâneas complexas. Descrevemos sua utilização em um caso com lesão coronária complexa, em outro com anatomia complexa, e em um terceiro caso com dissecção do enxerto de artéria torácica interna esquerda. Todos os procedimentos foram realizados com sucesso. O GuideLinerTM pode auxiliar no tratamento de lesões arteriais complexas e de complicações durante o procedimento.

    Resumo em Inglês:

    We report our initial experience with the GuideLinerTM, a "child" type rapid exchange guide-catheter extension, designed to facilitate stent and balloon delivery in complex percutaneous coronary interventions. We describe its use in a case of complex coronary lesion, a case of complex anatomy and a third case with a dissection of the left internal thoracic artery graft. All of the procedures were performed successfully. The GuideLinerTM can be used to treat complex artery lesions and to treat complications during the procedure.
  • Correção de regurgitação paravalvar mitral por via percutânea guiada por ecocardiograma transesofágico tridimensional Relatos De Caso

    Aguiar Filho, Gentil Barreira de; Guimarães, Guilhermo Guerra; Toledo, Leonardo Mello Guimarães de; Le Bihan, David Costa de Souza; Braga, Sergio Luiz Navarro; Esteves, Cesar Augusto

    Resumo em Português:

    A reoperação é o método de escolha para a correção de defeitos protéticos paravalvulares. A correção da regurgitação paravalvar mitral por via percutânea constitui uma alternativa interessante para casos selecionados. Relatamos dois casos com regurgitação paravalvar mitral, tratados por via percutânea, com prótese AmplatzerTM Vascular Plug III, guiados por ecocardiograma transesofágico tridimensional. No primeiro caso, o paciente, com 55 anos de idade, já havia sido submetido a tratamento cirúrgico por cinco vezes (trocas valvares aórtica e mitral) e evoluía com insuficiência cardíaca classe III da New York Heart Association (NYHA) e insuficiência mitral grave. No segundo caso, o paciente, com 76 anos de idade, tinha sido submetido a troca valvar aórtica por duas vezes, a última associada a troca valvar mitral, e evoluía em insuficiência cardíaca classe IV (NYHA) e regurgitação mitral grave, e várias comorbidades aumentavam seu risco cirúrgico. Os procedimentos foram realizados por via percutânea, sob anestesia geral, utilizando-se a via transeptal para o implante dos plugs, que ocluíram os defeitos paravalvares com sucesso em ambos os casos.

    Resumo em Inglês:

    Reoperation is the method of choice for correction of prosthetic paravalvular leaks. The percutaneous repair of mitral paravalvular leaks might represent an interesting alternative for selected cases. We report two cases of mitral paravalvular leaks treated with AmplatzerTM Vascular Plug III guided by three-dimensional transesophageal echocardiography using the percutaneous approach. The first case was of a 55-year old male who had undergone five previous cardiac surgeries (aortic and mitral valve replacements) and evolved with New York Heart Association (NYHA) class III heart failure and severe mitral regurgitation. The second case was of a 76-year old male previously submitted to aortic valve replacement twice, the last one associated to mitral valve replacement, which evolved with NYHA class IV heart failure and severe mitral regurgitation, and had several comorbidities increasing surgical risk. The procedures were performed percutaneously under general anesthesia using the transeptal approach to deploy the plugs, which occluded the paravalvular defects successfully in both cases.