Influence of the ergometric protocol in the onset of different criteria for maximal effort

Abstracts

INTRODUCTION AND OBJECTIVES: The aim of this study was to investigate the influence of different exercise protocols in the onset of maximal effort parameters. METHODS: Nine healthy individuals (23 ± 4 year old; 177 ± 10 cm; and 77.1 ± 16 kg) participated in three progressive exercise tests (PR1 - 15 W•min-1, PR2 - 50 W•3 min-1, and PR3 - 50 W•5 min-1) in a cycle ergometer. Oxygen consumption was measured in open circuit and was calculated at 20 s intervals. The maximal effort parameters considered here were: plateau in oxygen consumption < 150 mL•min-1; maximal heart rate > 95% predicted by age; blood lactate concentration (8.0 mM; and RER > 1.1. RESULTS: The VO2max was not different among exercise tests (2.68 ± 1.0; 2.58 ± 1.0 and 2.99 ± 1.3 L•min-1 for PR1; PR2 and PR3, p = 0.72). The highest plateau occurrence was in PR1 (5 individuals). The heart rate criterion was observed in 3 individuals in PR3, while the lactate criterion was fulfilled in 6 subjects in the same PR3 protocol. Regarding the RER parameter, only 6 subjects in PR1 achieved values > 1.1. CONCLUSION: It was concluded that the maximal effort parameters evaluated in this study are influenced by the exercise test, even when there are no differences in the VO2max

plateaus in oxygen consumption; VO2max; effort test


INTRODUÇÃO E OBJETIVO: Neste estudo investigamos a influência de diferentes protocolos ergométricos na ocorrência dos critérios de esforço máximo. MÉTODOS: Nove sujeitos fisicamente ativos (23 ± 4 anos, 177 ± 10cm, e 77,1 ± 16kg) realizaram três testes de esforço (PR1 - 15W·min-1, PR2 - 50W·3 min-1, e PR3 - 50W·5 min-1) no cicloergômetro. O consumo de oxigênio foi medido em circuito aberto e integrado a cada 20s. Adotaram-se como critérios de esforço máximo: o platô no consumo de oxigênio < 150 mL·min-1; frequência cardíaca máxima (FCmáx) > 95% prevista pela idade; lactato > 8,0 mM; e RER > 1,1. RESULTADOS: O VO2máx não apresentou diferenças entre os protocolos (2,68 ± 1,0; 2,58 ± 1,0 e 2,99 ± 1,3L·min-1 para PR1, PR2 e PR3, p = 0,72). A maior ocorrência do platô foi observada em PR1 (cinco sujeitos). O critério da frequência cardíaca máxima foi satisfeito em três sujeitos em PR3, e o critério do lactato em seis sujeitos, no mesmo protocolo (PR3). O RER > 1,1 foi observado em seis sujeitos em PR1. CONCLUSÃO: Concluímos que a ocorrência de diferentes critérios de esforço máximo é influenciada pela escolha do protocolo ergométrico, não indicando, contudo, valores distintos de VO2máx

platô do oxigênio; VO2máx; teste de esforço


ORIGINAL ARTICLE

CLÍNICA MÉDICA DO EXERCÍCIO E DO ESPORTE

Laboratório de Ergoespirometria, Serviço de Pneumologia, HSE-UFRJ; Laboratório de Biometria (Ladebio), PPGEF-UFRJ

Correspondence address

ABSTRACT

INTRODUCTION AND OBJECTIVES: The aim of this study was to investigate the influence of different exercise protocols in the onset of maximal effort parameters.

METHODS: Nine healthy individuals (23 ± 4 year old; 177 ± 10 cm; and 77.1 ± 16 kg) participated in three progressive exercise tests (PR1 - 15 W•min-1, PR2 - 50 W•3 min-1, and PR3 - 50 W•5 min-1) in a cycle ergometer. Oxygen consumption was measured in open circuit and was calculated at 20 s intervals. The maximal effort parameters considered here were: plateau in oxygen consumption < 150 mL•min-1; maximal heart rate > 95% predicted by age; blood lactate concentration (8.0 mM; and RER > 1.1.

RESULTS: The VO2max was not different among exercise tests (2.68 ± 1.0; 2.58 ± 1.0 and 2.99 ± 1.3 L•min-1 for PR1; PR2 and PR3, p = 0.72). The highest plateau occurrence was in PR1 (5 individuals). The heart rate criterion was observed in 3 individuals in PR3, while the lactate criterion was fulfilled in 6 subjects in the same PR3 protocol. Regarding the RER parameter, only 6 subjects in PR1 achieved values > 1.1.

CONCLUSION: It was concluded that the maximal effort parameters evaluated in this study are influenced by the exercise test, even when there are no differences in the VO2max.

Keywords: plateaus in oxygen consumption, VO2max, effort test.

INTRODUCTION

Maximal oxygen consumption (VO2max) is considered one of the main determinant factors in physical aptitude for its association with athletic performance(1,2) and with exercise diagnosis and prescription for cardiac and pneumonia patients(3,4). The main criterion of VO2max determination is the onset of a plateau in oxygen consumption close to exhaustion(5,6). This criterion was previously established by Taylor et al.(7), having as grounding discontinuous protocols, with long stages and loads applied with hours and even days of interval. Although there is no consensus among the exercise scientific community on the choice of the optimum criterion of maximum effort(5), the reference proposed by Taylor et al.(7) is the most widely used.

The plateau criterion has been little efficient(8-10) in ramp protocols or with small increment in short duration; thus, the term "oxygen consumption peak"has been applied whenever the plateau is not observed. However, many investigations have shown that there is not distinction between the VO2max value observed in discontinuous or with increments tests (10,11). Low incidence of VO2 plateau led to the application of other markers of maximum effort. The respiratory exchanges ratio (RER), maximum heart rate (HRmax) and blood lactate concentrations ([Lac]) have also been considered in the determination of the maximum effort, although the indices used as reference may present variations between studies(5,6).

It is known that variation in load increase or duration of stage in ergometric tests may lead to different responses of metabolic and respiratory parameters, such as: mechanical efficiency(12), maximum power reached and VO2max(13,14). Considering that it is not clear whether the onset of the complementary criteria of maximum effort is affected by the different combinations of load increase and duration of ergometric test, the aim of the present retrospective investigation was to determine the effect of the protocol in cycle ergometer in the onset of different criteria of maximum effort.

METHODS

Subjects

The present investigation was composed of nine volunteers (among them seven men) aged 23 ± 4 years, 177 ± 10cm of stature, and 77.1 ± 16.0kg of body mass, apparently healthy, nonsmokers and non-athletes, experienced in a cycle ergometer, engaged or not in aerobic training programs.

Abstinence from extenuating physical exercises for the 24h prior to the exam (> 5 METs) and alcohol ingestion were recommended. Additionally, maintenance of mixed diet in the 48h before the test and abstinence from food and caffeine in the three hours before the effort was recommended. Each subject was informed about the risks associated with the adopted procedures. A clarified consent form was read and signed. All procedures here adopted were aproved by the Local Ethics Committee for Experiments with Humans (Rio de Janeiro, CEP/HSE 000.021/99). This study was conducted according to the Declaration of Helsinki.

Experimental Procedure

The subjects were submitted to three different scaled, continuous and maximum effort protocols in a mechanical cycle ergometer (Monark , São Paulo, SP, Brazil), performed in a 7-14 days interval, at the same period of the day. Tests order was randomly established. Seat height was adjusted to each subject so that knee would keep an angle close to total extension (aprox. 175º). After six-minute rest, seated on the cycle ergometer seat, the subjects pedaled without load during four minutes and the scaled phase was initiated subsequently. Intensity was specific for each protocol: Protocol 1 (PR1) - 15W·min-1; Protocol 2 (PR2) - 50W·3min-1; and Protocol 3 (PR3) - 50W·5min-1. The subjects maintained cadence during the exam (1.0Hz). The rhythm was controlled by na audiovisual metronome (Witter Junior Plast 826, Isny/ Allgäu, Germany).

Analysis of the physiological and metabolic parameters

The minute ventilation (VE) and oxygen and carbon dioxide expired fractions were continuously measured by indirect calorimetry of open circuit (TEEM 100® Total Metabolic Analysis System, Aerosport, Ann Arbor, Mich., USA)(15-18). The subjects used a nose clip and a medium flow pneumotachometer (Hans Rudolph® , Kansas City, MO, USA). Oxygen consumption per minute (VO2) and excretion of carbon dixide per minute (VCO2) were presented at every 20 seconds. Heart rate (HR) was continuously monitored during the test by telemetry (Vantage NV®, Polar Electro Oy, Kempele, Finland) and the concept of perceived exertion (CPE), in Borg's scale from 6 to 20, was collected at the end of each stage.

25µL ob blood were collected by earlobe puncture at hyperemia, according to procedures described by Shephard(19). Collections were performed during rest, at the two minutes before the exam and at every two minutes of effort in PR1 and at the final minute of each stage in PR2 and PR3. The samples were immediately assessed by electroenzymatic method (YSI 1500 Sport L-Lactate Analyser®, Yellow Springs, USA). Total blood lactate was determined by the addition of the Triton X-100 hemolytic agent (YSI #1515 Agent Cell Lysing, USA) at 0.25% to the buffering solution. Blood collections were performed by an experienced evaluator between 20 and 25 seconds.

Controls and calibration

The metabolic analyzer, the lactate analyzer and the cycle ergometer were calibrated before each test. The ergospirometer was calibrated in closed circuit through a certified gas mixture containing 17.01% of oxygen, 5.00% of carbon dioxide and balanced with nitrogen (AGA®, Rio de Janeiro, RJ, Brazil). The flow was calibrated with the use of a three-liter air syringe (Hans Rudolph® , Kansas City, MO, USA). At the end of each test, measurement of the oxygen and carbonic dioxide percentage fractions in the gase misture applied for calibration was performed. Maximum variation allowed was 16.16 to 17.86% for FO2 and 4.75 to 5.25% for FCO2. The lactate analyzer had calibration confirmed before the test, through a standard solution of 5mmol·L-1 (YSI #2327 Lactate Standard YSI®, USA) of lactate. A new calibration was performed before each test and at each hour of use. Equipment linearity was confirmed until 15mmol·L-1 of lactate. Equipment accuracy was checked before the beginning of the experiment through a calibration curve with patterns of 1.0; 2.5; 5.0; 7.5; 12.0; 15.0; 18.0; 24.0; and 30.0mmol·L-1, prepared through the dilution of the patterns provided by the manufacturer (YSI #2327: 5mmol·L-1; YSI #2328: 15mmol·L-1, YSI #1530: 30mmol·L-1 Lactate Standard YSI®, USA). The association between the values measured and expected in the calibration curve was r = 0.999, y = 0.9436x + 0.33011 and EPE = 0.20mmol.L-1. The cycle ergometer was calibrated through 3kg load.

Maximum effort criteria

The plateau of oxygen consumption was used as main criterion of maximum effort. For the plateau determination, the difference in the VO2 measurement between the last two stages of the ergometric test was applied. Such difference was defined as ΔVO2final. Considering the original criterion of the plateau of oxygen consumption established in the work by Taylor et al.(7), the onset of this phenomenon was determined when ΔVO2final was < 150mL·min-1. Other maximum effort criteria were also considered(6): RER > 1.1; HRmax> 95% of the maximum expected by age (220 - age); and [Lac] at the end of the test > 8.0 mM.

Statistical analysis

Statistical treatment was performed through Statistica® (Statsoft® , version 7.0, USA) and Microsoft Excel® for Windows XP® programs (Microsoft, USA). Descriptive statistics with mean ± standard deviation was applied (SD). The experimental outlining of the present study was counterbalanced. Variance analysis (ANOVA) with one factor (protocol) for repeated samples and Tukey-HSD post-hoc test were used for comparison of the different protocols used. Significance level established for this study was of p < 0.05.

RESULTS

The physiological responses obtained in each protocol are found in table 1. Duration of the progressive effort test (Texhaustion) in PR3 was significantly higher than in PR1 and PR2 (p = 0.0002). The maximum power reached (Pmax) did not present differences between protocols (p = 0.28), although PR2 has suggested lower values in this parameter. Moreover, no difference was observed in the VO2max (p = 0.72), RER (1.1 ± 0.1 in all tests, p = 0.72), and HRmax (p = 0.59), despite a tendency of higher values in PR3 in this last index. Final concentration of blood lactate ([Lac]) was significantly higher in PR3, when compared to the other protocols (p = 0.04). The ΔVO2final presented great variation between individuals and between protocols (figure 1), reaching minimum and maximum values of: 5-485mL·min-1 in PR1, 68-1798mL·min-1 in PR2, and 230-1375mL·min-1 in PR3. Significant differences were observed for ΔVO2final, being it lower in PR1, when compared to PR2 and PR3 (p = 0.01).


The onset of the maximum effort criteria used in this study was sensitive to the ergometric protocol (table 2). There was higher occurrence of plateau in the oxygen consumption in PR1, being it low in PR2 and not being observed in PR3; however, the subjects who reached the plateau in PR1 and PR2 were not the same. The heart rate criterion (HR) was met in few subjects in PR1 and PR3, not being met in PR2. The [Lac] reached higher or equal to 8.0mM values in a high number of subjects in PR3, with low occurrence of this criterion in PR1 and PR2. RER was the criterion of highest occurrence among the observed ones. When the maximum effort criteria were combined, little coherence was observed. Out of the five subjects who presented plateau in PR1, only four reached RER values within the pre-set cohort, with no occurrence of HR and [Lac] criteria. In PR2, in the only subject who presented plateau, no other criterion adopted was observed. In PR3, although we have not observed plateau in any subject, this was the protocol with the highest occurrence of the HR and [Lac] criteria, with occurrence for RER as well (table 2).

DISCUSSION

The present investigation considered that the plateau in the O2 consumption may not be a suitable criterion for determination of of VO2max when compared with different ergometric protocols, and the use of different maximum effort criteria, separately or combined analyzed, may not be guarantee of higher accuracy in the determination of this important metabolic index. Thus, we aimed to determine the effect of protocol in cycle ergometer in the occurrence of different maximum effort criteria.

The sample of this study was composed of subjects with the following characteristics: non-athletes, healthy, with high or low experience in cycle ergometer, engaged or not in aerobic training programs. Hereditary characteristics and involvement in exercise programs may influence in the VO2max values. Regardless of considering the individuals' experience with a cycle ergometer, this equipment may overload the lower limbs, causing hence early fatigue(4). Fatigue of lower limbs may result in low VO2max(20). The influence of different protocols in the measurement of the VO2max has been examined and it was observed that variations in the stage duration or load increase in progressive tests do not significantly affect the VO2max(12,21) measurement; however, other investigations have shown clashing results(14,22). In the present study, we assessed protocols with difference in stage duration as well as load increase and no significant difference has been observed in VO2max. Previous investigations observed VO2max lower indices in protocols with higher total duration(13,14).

Accuracy in the measurement of the gas and ventilatory exchanges is crucial to enable data reproduction. The measurements quality control should be assured through calibration, operation and assessment procedures conducted by experienced technicians(23). Tests in which these care measures are taken present low variation in the repeated measurements in close moments(15-17,23,24). The intra-individual daily variation, due to error and physiological fluctuations of VO2, VE and HR are (24) respectively 3.8%, 8.0% and 3.0%. Granja Filho et al.(17) observed intra-individual variation index of 5.5% for the VO2max. Nogueira and Pompeu(25) and Magrani and Pompeu(26) observed satisfactory indices for the measurements assessed in equipment similar to the one adopted here. Despite the higher inaccuracy of obtained measurements, comparing to the more sophisticated equipments (3.8% versus 5.5%), the ergospirometer adopted here was validated by other groups(15,16) and is widely used in Brazilian laboratories due to its lower cost.

There are countless criteria used for VO2max assessment; however, no consensus is presented concerning which method is the most suitable(5). Nevertheless, this controversy does not make the use of criteria established for the present study invalid, since the intention was to demonstrate the influence of the ergometric protocol in the onset of these indices. Originally established in ergometric tests of constant load (7), the plateau criterion has been criticized about its adaptability for characterization of the VO2max in progressive tests(5,6). Many studies comparing tests of constant load and progressive tests were not able to observe significant differences in the VO2max value between tests, although the plateau of oxygen consumption has been observed only in some of the tested subjects(8-10).

The use of other criteria of maximum effort determination, separated or combined, has also been previously assessed. Duncan et al.(9) observed the incidence of plateau in 50% of the subjects tested in two ergometric protocols, although the [Lac] and RER criteria had been reached by a higher number of individuals (90-100%). Similar results were obtained by Doherty et al.(11), in which RER and HR were satisfied by more than 60% of the subjects, although the plateau had only been reached by less than 40% of these subjects. When the onset of different criteria of maximum effort between elite athletes and sedentary individuals was compared, using analyses similar to the ones in the present study (RER > 1.1; HRmax > 95% of maximum expected by age; [Lac] > 8 mM), but a distinct definition of plateau (ΔVO2 < 1.5 mL kg-1(min-1)), Lucia et al.(27) observed that the RER was met in 100% of the volunteers. However, significant differences between athletes and sedentary individuals were found for the onset of HR criterion (82% for athletes and 68% for sedentary subjects), for [Lac] (84% and 73%, for athletes and sedentary subjects, respectively), and for the plateau (47% for athletes and only 24% for sedentary subjects). Lacour et al.(28) attribute the onset of plateau in high levels of blood lactate reached by their subjects. [Lac] was assessed at the end of the test and during recovery and results lower in the group which presented plateau were observed (~6 mM) compared to the ones who obtained higher indices (~8 mM). Difference in the VO2max between groups was not observed. The outcomes of the present investigation are in agreement with the ones by Lacour et al.(28). Using statistical techniques for the plateau determination and different criteria for RER and HR, Poole et al.(29) concluded that the use of these criteria is not in fact determinant for VO2max validation.

Considering that the plateau of oxygen consumption onset as well as of other criteria used for VO2max determination is influenced by the choice of the ergometric protocol and that differences in this onset do not indicate distinct VO2max values between protocols, it can be concluded that the general use of plateau or other criteria of maximum effort for comparison of different ergometric tests does not seem to be adequate.

ACKNOWLEDGEMENTS

The authors of this study express their gratitude to the Association of Friends of the Center of Studies and Improvement of the Hospital of the Servants of the State of Rio de Janeiro represented by Dr. Aluysio S. Aderaldo Jr. his significant contribution for this work performance. This study received grants from FAPERJ and MCT/ CNPq.

REFERENCES

  • 1. Åstrand P-O. Principles in ergometry and their implications in sports practice. Sports Med 1984;1:1-5.
  • 2. Snell PG, Stray-Gundersen J, Levine BD, Hawkins MN, Raven PB. Maximal oxygen uptake as a parametric measure of cardiorespiratory capacity. Med Sci Sports Exerc 2007;39:103-7.
  • 3. Monteiro HL, Rolim LMC, Squinca DA, Silva FC, Ticianeli CCC, Amaral SL. Efetividade de um programa de exercícios no condicionamento físico, perfil metabólico e pressão arterial de pacientes hipertensos. Rev Bras Med Esporte 2007;13:107-12.
  • 4. Fleg JL, Pina IL, Balady GL, Chaitman BR, Fletcher B, Lavie C, et al. Assessment of functional capacity in clinical and research applications: An advisory from the Committee on Exercise, Rehabilitation, and Prevention, Council on Clinical Cardiology, American Heart Association. Circulation 2000;102:1592-7.
  • 5. Howley ET, Basset DR, Welch HG. Criteria for maximal oxygen uptake: review and commentary. Med Sci Sports Exerc 1995;27:1292-301.
  • 6. Midgley AW, McNaughton LR, Polman R, Marchant D. Criteria for determination of maximal oxygen uptake. Sports Med 2007;37:1019-28.
  • 7. Taylor H, Buskirk E, Henschel A. Maximal oxygen uptake as an objective measure of cardio-respiratory performance. J Appl Physiol 1955;8:73-80.
  • 8. Rowland TW. Does peak VO2 reflect VO2max in children?: evidence from supramaximal testing. Med Sci Sports Exerc 1993;25:689-93.
  • 9. Duncan GE, Howley ET, Johnson BN. Applicability of VO2max criteria: discontinuous versus continuous protocols Med Sci Sports Exerc 1997;29:273-8.
  • 10. Day JR, Rossiter HB, Coats EM, Skasick A, Whipp BJ. The maximally attainable VO2 during exercise in humans: the peak versus maximum issue. J Appl Physiol 2003;95:1901-7.
  • 11. Doherty M, Nobbs L, Noakes TD. Low frequency of the "plateau phenomenon"during maximal exercise in elite British athletes. Eur J Appl Physiol 2003;89:619-23.
  • 12. Scheuermann BW, McConnell JHT, Barstow TJ. EMG and oxygen uptake responses during slow and fast ramp exercise in humans. Exp Physiol 2000;87:91-100.
  • 13. Buchfuhrer MJ, Hansen JE, Robinson TE, Sue DY, Wasserman K, Whipp BJ. Optimizing the exercise protocol for cardiopulmonary assessment. J Appl Physiol 1983;55:1558-64.
  • 14. Kang J, Chaloupka EC, Mastrangelo MA, Biren GB, Robertson RJ. Physiological comparisons among three maximal treadmill exercise protocols in trained and untrained individuals. Eur J Appl Physiol 2001;84:291-5.
  • 15. Novitsky S, Segal KR, Chatr-Aryamontri B, Guvakov D, Katch VL. Validity of a new portable indirect calorimeter: the Aerosport TEEM 100. Eur J Appl Physiol Occup Physiol 1995;70:462-7.
  • 16. Wideman L, Stoudemire NM, Pass KA, McGinnes CL, Gaesser GA, Weltman A. Assessment of the Aerosport TEEM 100 portable metabolic measurement system. Med Sci Sport Exerc 1996;28:509-15.
  • 17. Granja Filho PCN, Pompeu FAMS, Ribeiro P. A acurácia da determinação do VO2máx e do limiar anaeróbio. Rev Bras Med Esporte 2005;11:167-71.
  • 18. Nogueira FS, Pompeu FAMS. Modelos para predição da carga máxima no teste clínico de esforço cardiopulmonar. Arq Bras Cardiol 2006;87:137-45.
  • 19. Shephard RJ. Muscular Endurance and Blood Lactate. In: Endurance in Sport. R.J. Shephard and P-O. Åstrand, eds. Oxford: Blackwell Scientific Publications, 1992. pp. 215-25.
  • 20. Wasserman K, Hansen JE, Sue DY, Whipp BJ, Casaburi R. Principles of exercise testing and interpretation. 3rd ed. Philadelphia: Lea & Febiger, 1999.
  • 21. Kuipers H, Rietjens G, Verstappen F, Schoenmakers H, Hofman G. Effects of stage duration in incremental running tests on physiological variables. Int J Sports Med 2003;24:486-9.
  • 22. Weston SB, Gray AB, Schneider DA, Gass GC. Effect of ramp slope on ventilation thresholds and VO2peak in male cyclists. Int J Sports Med 2002;23:22-7.
  • 23. Guimarães JI, Stein R, Vilas-Boas F, et al. Normatização de técnicas e equipamentos para realização de exames em ergometria e ergoespirometria. Arq Bras Cardiol 2003;80:458-64.
  • 24. Jones NL, Kane JW. Quality control of exercise test measurements. Med Sci Sports 1979;11:368-72.
  • 24. Nogueira FS, Pompeu FAMS. Precisão da medida do limiar anaeróbio através do calorímetro portátil. Arq Bras Cardiol 2010 (in press).
  • 26. Magrani P, Pompeu FAMS. Equações de predição do VO2máx de Jovens adultos Brasileiros. Arq Bras Cardiol (in press).
  • 27. Lucia A, Rabadan M, Hoyos J, Hernandez-Capilla M, Perez M, Sab Juan AF, et al. Frequency of the VO2max plateau phenomenon in world-class cyclists. Int J Sports Med 2006;27:984-92.
  • 28. Lacour J-R, Messonnier L, Bourdin M. The leveling-off of oxygen uptake is related to blood lactate accumulation: retrospective study of 94 elite rowers. Eur J Appl Physiol 2007;101:241-7.
  • 29. Poole DC, Wilkerson DP, Jones AM. Validity of criteria for establishing maximal O2 uptake during ramp exercise tests. Eur J Appl Physiol 2008;102:403-10.
  • Influence of the ergometric protocol in the onset of different criteria for maximal effort

    Thiago Lemos; Fernando S. Nogueira; Fernando A.M.S. Pompeu
  • Publication Dates

    • Publication in this collection
      30 Nov 2011
    • Date of issue
      Feb 2011
    Sociedade Brasileira de Medicina do Exercício e do Esporte Av. Brigadeiro Luís Antônio, 278, 6º and., 01318-901 São Paulo SP, Tel.: +55 11 3106-7544, Fax: +55 11 3106-8611 - São Paulo - SP - Brazil
    E-mail: atharbme@uol.com.br