Acessibilidade / Reportar erro

Microbial contamination in eye drops of patients in glaucoma treatment

Abstract

Objetives:

To assess the degree of fungal and bacterial contamination of hypotensive eye drops and the way these are preserved by the patients at the Glaucoma outpatient clinic of Santa Casa Hospital in Ribeirão Preto.

Methods:

Fifty-five patients were randomly assigned to follow-up in the outpatient clinic and, after their consent, an eye drop was collected per patient and later sent by mail for analysis by microbiologist and pathologist in up to 72 hours. Approximately 0.5ml of the medications were analyzed and the patients were asked to answer a simple questionnaire on the method of drug conservation and whether they considered it adequate.

Results:

Of the 55 analysed eye drops, five (9.01%) had their liquid contents contaminated. Among the microorganisms isolated there were 4 Gram negative bacteria, 1 (1.8%) by Serratia marcenses, 1 (1.8%) Pseudomonas aeruginosa and 2 (3.6%) Stenotrophomas maltophilia. An eye drop was contaminated by the fungus Candida ssp. All the patients in the study judged their methods of storage and instillation appropriate. The patients who had the positive coliria were summoned for clinical examination and passed through a new questionnaire by the investigator.

Conclusion:

The time and methods of preservation influence the contamination of medicinal products. All the eye drops that presented growth of microorganisms in the present study were open between 30 and 90 days. The fact that most patients take their eye drops on daily tasks increases the exposure of the bottles and can be a relevant fact to determine the contamination of these medications.

Keywords:
Eye drops; Ophthalmic solutions; Bacterial contamination; Remedy expiration