Acessibilidade / Reportar erro

Operating room fire prevention - preventive measures for safe eyelid surgery

Abstract

Fire in the surgical field during eyelid surgery is an intra-operative complication that is dramatic for both the patient and the medical staff. It’s being reported a case of surgical accident during eyelid surgery where the patient suffered a brow burn. There was interaction between the oxygen used for sedation (open mask) and a source of ignition represented by monopolar cautery. Although the patient presented good clinical evolution with complete recovery of the cutaneous lesion, this case is an alert to avoid such type of occurrence. This work highlights the conditions involved and the way of prevention.

Keywords:
Fire/prevention & control; Operating room; Risk factors; Eyelids/surgery