Acessibilidade / Reportar erro

Evaluation of the Reliability and Reproducibility of the Roussouly Classification for Lumbar Lordosis Types

Abstract

Objective

The present study aims to determine the intra- and inter-rater reliability and reproducibility of the Roussouly classification for lumbar lordosis types.

Methods

A database of 104 panoramic, lateral radiographs of the spine of male individuals aged between 18 and 40 years old was used. Six examiners with different expertise levels measured spinopelvic angles and classified lordosis types according to the Roussouly classification using the Surgimap software (Nemaris Inc., New York, NY, USA). After a 1-month interval, the measurements were repeated, and the intra- and inter-rater agreement were calculated using the Fleiss Kappa test.

Results

The study revealed positive evidence regarding the reproducibility of the Roussouly classification, with reasonable to virtually perfect (0.307-0.827) intra-rater agreement, and moderate (0.43) to reasonable (0.369) inter-rater agreement according to the Fleiss kappa test. The most experienced examiners showed greater inter-rater agreement, ranging from substantial (0.619) to moderate (0.439).

Conclusion

The Roussouly classification demonstrated good reliability and reproducibility, with intra- and inter-rater agreements at least reasonable, and reaching substantial to virtually perfect levels in some situations. Evaluators with highest expertise levels showed greater intra and inter-rater agreement.

Keywords:
spinal curvatures; postural balance; lordosis/classification

Sociedade Brasileira de Ortopedia e Traumatologia Al. Lorena, 427 14º andar, 01424-000 São Paulo - SP - Brasil, Tel.: 55 11 2137-5400 - São Paulo - SP - Brazil
E-mail: rbo@sbot.org.br