Acessibilidade / Reportar erro

Prospective randomized study after the use of drains in total knee arthroplasty with implant

Abstracts

OBJECTIVE:

to compare the laboratorial results of opening suction drainage 6 hours and 12 hours after total knee arthroplasty surgery.

METHODS:

prospective and randomized study in 88 patients undergoing with total knee arthroplasty in two groups: in one group the opening suction drainage was performed 6 hours (n = 45) after the surgery and in the other 12 hours (n = 43) after the surgery.

RESULTS

: the outcome was a significant fall in the three laboratorial variables (hemoglobin, red blood cells and hematocrit) between the pre and post-operative in the total sample and in the six and 12 hour opening suction drainage groups. In the group with opening suction drainage after 12 hours, the drainage volume was significantly lower than in the group with opening suction drainage after 6 hours (p = 0.0003). However, no significant difference was observed in the absolute delta of the laboratorial variables between the two groups.

CONCLUSION:

the opening suction drainage in six and 12 hours did not show significant difference from the laboratorial values although the volume of the blood drained was higher in the opening suction drainage in six hours.

Arthroplasty, replacement, knee ; Flood-bypass channel ; Prostheses and implants


OBJETIVO

: Comparar os resultados laboratoriais da abertura do dreno seis e 12 horas após a cirurgia de artroplastia total do joelho.

MÉTODOS

: Estudo prospectivo e randomizado em 88 pacientes tratados com artroplastia total do joelho com implante em dois grupos: um com abertura do dreno seis horas (n = 45) após a cirurgia e outro, 12 horas (n = 43) após a cirurgia.

RESULTADOS

: Existe uma queda significativa nas três variáveis laboratoriais (hemoglobina, hemácias e hematócrito) entre o pré e o pósoperatório na amostra total e nos grupos de tempo de abertura do dreno às seis e 12 horas. O grupo com tempo de abertura após 12 horas apresentou volume do dreno significativamente menor do que o grupo com tempo de abertura após 6 horas (p = 0,0003). Contudo, não foi verificada diferença significativa no delta absoluto das variáveis laboratoriais entre os dois grupos.

CONCLUSÃO

: A abertura do dreno em seis e 12 horas não demonstrou diferença significativa dos valores laboratoriais. Porém, o volume de sangue drenado foi maior com abertura do dreno após seis horas.

Artroplastia total do joelho ; Canal de drenagem ; Próteses e implantes


Introduction

Total knee arthroplasty is widely used in the treatment of osteoarthritis and moderate or severe rheumatoid arthritis. However, the use of suction drains in the joint is still controversial. In theory, drainage prevents hematoma formation at the surgical site, decreases tension over the incision (which consequently decreases pain), reduces the retardation of wound healing and reduces the risk of infection.1,2 However, the drainage system inevitably increases bleeding because the tamponade effect does not occur at the surgical site. In addition, it can cause a retrograde infection.3 However, several studies have shown that postoperative drainage in total knee arthroplasty is not necessary, although it is still widely used by orthopedic surgeons.3-7

Despite the blood loss that occurs after total knee arthroplasty during the first postoperative hours (37% in the first two hours and 55% in the following hours), drainage clamping may be used to create a temporary tamponade effect and to control bleeding.8,9

This study aimed to compare the laboratory results of the open suction drainage at six and 12 hours after total knee arthroplasty.

Materials and Methods

Between May 2010 and July 2011, total knee arthroplasty was performed on 102 patients at the Hospital Santa Teresa, Petrópolis, RJ, Brazil. The criterion for this prospective and randomized study was the treatment of patients with primary knee arthrosis using the same type of cemented implant (Nexgen®). In all cases, patellar arthroplasty was included. Patients were advised to suspend the use of any medication that could interfere with coagulation at least 15 days prior to surgery. Fourteen patients were excluded; eight patients were excluded due to the loss of the drains after surgery and six patients due to their use of implants. Of the 88 patients treated with total knee arthroplasty, there were no bilateral cases or any bleeding disturbances observed after surgery. The patients were randomly divided into two groups after surgery using an envelope: the first group had open suction drainage at six hours (n = 45) after surgery and a second group had opened suction drainage at 12 hours (n = 43) after surgery. Osteoarthritis was diagnosed according to Alhback10 into five types, and the cases were treated on the basis of type II.

A surgeon with more expertise supervised all of the patients who underwent surgery, and the same surgical technique and pneumatic tourniquet were performed. Rachianesthesia was used on all of the patients. In cases with varus deformity (n = 59), the medial parapatellar approach was used, and in cases with valgus (n = 29) Kerbish, a lateral approach was used.11 The tourniquet was released after wound closure. In addition, a vacuum aspiration drain of 4.8 mm in diameter was used. The drain and compression dressing were maintained for 24 hours. The patients were then subjected to a protocol for thromboembolism prevention, which began six hours after the end of the surgery using heparin of a low molecular weight over 10 days.

Immediately after surgery, the patients were immobilized with a compression bandage for two days. On the third day, after removal of the bandage, the patients were advised to start walking.

The general profile of the 88 patients who participated in this study, which includes the mean, standard deviation (SD), median and the minimum and maximum values of the numerical variables, are shown in Table 1.

Table 1
General description of the basal numerical variables.

In addition, the frequency (n) and percentage (%) of the basal categorical variables are shown in Table 2.

Table 2
General description of the basal category variables.

Statistical evaluation

A descriptive analysis is presented in the tables containing the observed data, which were expressed as the frequency (n) and percentage (%) of the categorical data (qualitative). In addition, the mean, standard deviation (SD), median and minimum and maximum values for the numerical data are also provided.

The statistical analysis was performed using the following methods:

- a comparison of the basal numerical variables between the groups with a tourniquet opening (6 hours vs. 12 hours) was performed using Studentâ€(tm)s t-test for independent samples or the Mann-Whitney test. For the categorical variables, the χ2 test or Fisherâ€(tm)s Exact test was used;

- the variation in the pre- and post-treatment laboratory variables was calculated using Studentâ€(tm)s t-test for paired samples;

- the differences in the drain volume and in the deltas of the laboratory variables between the two groups with the tourniquet opening were analyzed using the Mann-Whitney test.

Non-parametric tests were performed because some of the variables did not present a normal distribution (Gaussian distribution) due to dispersion of the data and the rejection of the normality hypothesis according to the Kolmogorov-Smirnov test. The criterion for the determination of significance was set at 5%. Statistical analyses were performed using the SAS 6.11 software package (SAS Institute, Inc., Cary, North Carolina, USA).

Results

Our study consisted of two patient groups: the first and second groups had an open suction drain at six (n = 45) and at 12 hours (n = 43) after surgery, respectively.

In addition, we performed statistical analyses to confirm whether there was a significant difference in the basal variables between the groups regarding the numerical variables. The mean ± standard deviation (SD), median of the basal numerical variables according to the group (six vs. 12 hours) and corresponding descriptive level of Studentâ€(tm)s t-test for independent variables (age and laboratory variables) or the Mann-Whitneyâ€(tm)s test (valgus and varus angle) are shown in Table 3. Importantly, there was no difference in the basal numerical variables between the two groups.

Table 3
Basal numerical variables according to the drain opening time.

Furthermore, the presence of an association with the categorical variables was also determined. The frequency (n) and percentage (%) of the basal categorical variables according to the group (six vs. 12 hours) and corresponding descriptive level (p-value) of the χ2 test or Fisherâ€(tm)s Exact test are shown in Table 4.

Table 4
Basal category variables according to the drain opening time.

Moreover, we also performed statistical analyses to confirm whether there was a significant variation between the pre- and postoperative period in the laboratory variables. The mean ± standard deviation and corresponding descriptive level (p-value) of Studentâ€(tm)s paired t-test are provided in Table 5.

Table 5
Laboratory variables between the pre- and postoperative care in the total sample and according to the drain opening time group.

A significant decrease in the three laboratory variables between the pre- and postoperative period was observed in the total sample and in the two groups treated with drain opening at six and 12 hours.

An additional objective of this study was to confirm whether there was a significant difference in the drain volume and in the levels of laboratory variables between the two groups (opening time at six hours vs. 12 hours). The mean ± standard deviation (SD) and mean of the drain volume, absolute deltas of the laboratory variables and corresponding descriptive level of the Mann-Whitney test are shown in Table 6.

Table 6
Drain volume and deltas of the laboratory variables according to the drain opening time (12 h and 6 h).

The absolute delta was calculated using the following formula:

Absolute Delta = variable after treatment â€" variable before treatment.

Importantly, the group with the drain opening time at 12 hours after surgery presented a significantly lower drain volume compared to the group treated at six hours (p = 0.0003) after surgery. However, no significant difference was observed in the absolute delta of the laboratory variables between the groups.

Discussion

Total knee arthroplasty is a widely used procedure that produces good results.12 Although it is controversial, drainage is a procedure that is normally used after arthroscopy; thus, it should be re-evaluated by surgeons.13,14 However, a point of discussion is whether the drainage system offers benefits regarding wounds, and if so, when do these benefits occur? In theory, drainage evacuates the developing hematoma at the surgical site and aids in wound healing.2 Waugh et al.15 support the use of drainage after several orthopedic procedures because it prevents hematoma formation and reduces the incidence of complications in the wound. However, other studies have shown that the placement of the drain after total knee arthroplasty does not affect the incidence of complications, mean time of hospitalization and functional recovery. Moreover, drainage after total knee arthroplasty reduces the tamponade effect and increases blood loss in the wound.2,3,5,16-20 In addition, Kim et al.2 observed that, unlike drained wounds (10.1%), wounds that were not drained demonstrated a high incidence (60.9%) of bleeding, which would soak the dressings and cause ecchymosis and erythema around the wound.

The time for drainage release varies among different studies. In one study, Aksoy et al.14 closed the wound, covered it with elastic bandages, and the drain was closed for two hours. They did not observe a significant difference in the amount of drained blood, in the levels of hemoglobin and hematocrit, or in the need for a transfusion during the postoperative period. In another study, Sedna et al.21 closed the drain for one hour after total knee arthroplasty and reported a reduction in bleeding in the postoperative period. Furthermore, Roy et al.22 used the technique of clamping the drain for one hour after surgery and showed that the amount of blood loss was 732 mL (620-845 mL) in the group with the closed drain and 1,050 mL (728-1,172 mL) in the control group. Although blood loss was significantly reduced and a decrease in the mean hemoglobin rate was observed in these patients, a transfusion was not required among the groups. Kiely et al.23 used the technique of clamping the drain for two hours and did not find a difference regarding blood loss, a reduction in hemoglobin levels or the need for a transfusion. However, Stucinskas et al.24 and Shen et al.25 maintained the drain clamp for four hours during the postoperative period and found a significant reduction in blood loss. Taken together, the amount of blood transfusion in both studies was reduced, but Stucinskas did not report a difference in the postoperative levels of hemoglobin and hematocrit. Furthermore, Raleigh et al.26 used a method of intermittent clamping for five minutes every two hours during the first six hours after surgery. The drain was then clamped again in the 12th hour and in the 24th hour for five minutes. The results showed that although the amount of bleeding was reduced, there was no difference in the transfusion rates in the postoperative period. In addition, Prasad et al.27 compared two intermittent methods for drain clamping. Using two patient groups, they maintained drain clamping in the first group for one hour and then every two hours for 10 minutes in the second group for the first 24 hours. Blood loss in the second group was significantly lower compared to the first group; however, no significant differences in the blood transfusion rates and in the levels of hemoglobin were observed. Tai et al.26 demonstrated that drain clamping for less than four hours did not reduce drainage and did not change the blood transfusion rates. In our study, there was no difference between the levels of hemoglobin, hematocrit and the amount of red blood cells between patients with a drain opening at six and 12 hours, as demonstrated by the absolute delta determined during pre- and postoperative care. However, there was a similar significant decrease in the laboratory variables after treatment in both groups.

Most studies have focused on the amount of blood loss by draining in the postoperative period but have not examined the amount of blood lost after a tourniquet release in the compression dressing or in the blood soaked in the tissues.22,27,28 Our study demonstrated that there was a reduction in the levels of hemoglobin, hematocrit and red blood cells in both groups. In the group with the drain opening after six hours, the amount of drained blood was 230.7 mL. In the group with the drain opening after 12 hours, the amount of drained blood was 158.6 mL. In addition, a difference was observed between the two groups that were treated at six and 12 hours, and a similarity between the laboratory levels was most likely due to the blood loss in the tissues and dressings, which could not be measured.

The positive aspect of this study was the presence of a difference in bleeding regarding the aspiration drain between the groups treated at six and 12 hours, although this difference has not yet been confirmed at the laboratory level due to the blood dissipation in the tissues and dressings in the group treated at 12 hours. A negative aspect of this study was the lack of comparison with clinical results.

Conclusions

Patients undergoing total knee arthroplasty with drain opening at six and 12 hours after surgery did not show a significant difference in laboratory values. However, the volume of blood drained was higher after drain opening at six hours.

REFERENCES

  • 1
    Holt BT, Parks NL, Engh GA, Lawrence JM. Comparison of closed suction drainage and no drainage after primary total knee arthroplasty. Orthopedics. 1997;20(12):1124-5.
  • 2
    Kim YH, Cho SH, Kim RS. Drainage versus nondrainage in simultaneous bilateral total knee arthroplasties. Clin Orthop Relat Res. 1998;(347):188-93.
  • 3
    Esler CN, Blakeway C, Fiddian NJ. The use of a closed suction drain in total knee arthroplasty. A prospective, randomized study. J Bone Joint Surg Br. 2003;85(2):215-7.
  • 4
    Adalberth G, Bystrom S, Kolstad K, Mallmin H, Milbrink J. Postoperative drainage of knee arthroplasty is not necessary: a randomized study of 90 patients. Acta Orthop Scand. 1998;69(5):475-8.
  • 5
    Niskanen RO, Korkala OL, Haapala J, Kuokkanen HO, Kaukonen JP, Salo SA. Drainage is of no use in primary uncomplicated cemented hip and knee arthroplasty for osteoarthritis: a prospective randomized study. J Arthroplasty. 2000;15(5):567-9.
  • 6
    Parker MJ, Roberts CP, Hay D. Closed suction drainage for hip and knee arthroplasty. A meta-analysis. J Bone Joint Surg Am. 2004;86(6):1146-52.
  • 7
    Jones AP, Harrison M, Hui A. Comparison of autologous transfusion drains versus no drain in total knee arthroplasty. Acta Orthop Belg. 2007;73(3):377-85.
  • 8
    Senthil Kumar G, Von Arx OA, Pozo JL. Rate of blood loss over 48 hours following total knee replacement. Knee. 2005;12(4):307-9.
  • 9
    Jou IM, Lai Ka, Yang CY. Blood loss associated with total knee arthroplasty. J Orthop Surg (ROC). 1993;10:213.
  • 10
    Ahlbäck S. Osteoarthrosis of the knee: a radiographic investigation. Acta Radiol Diagn (Stockh). 1968:(Suppl 277):7-72.
  • 11
    Keblish PA. The lateral approach to the valgus knee: Surgical technique and analysis of 53 cases with over two-year follow-up evaluation. Clin Orthop Relat Res. 1991;(271):52-62.
  • 12
    Zhang QD, Guo WS, Zhang Q, Liu ZH, Cheng LM, Li ZR. Comparison between closed suction drainage and nondrainage in total knee arthroplasty. A meta-analysis. J Arthroplasty. 2011;26(8):1265-72.
  • 13
    Li C, Nijat A, Askar M. No clear advantage to use of wound drains after unilateral total knee arthroplaty. A prospective randomized, controlled trial. J Arthroplasty. 2011;26(4):519-22.
  • 14
    Aksoy Y, Altinel L, Köse KÇ. The comparison of the effects of intraoperative bleeding control and postoperative drain clamping methods on the postoperative blood loss and the need for transfusion following total knee arthroplaty. Acta Orthop Traumatol Turc. 2011;45(3):190-4.
  • 15
    Waugh TR, Stinchfield FE. Suction drainage of ortthopaedic wounds. J Bone Joint Surg Am. 1961;43:939-46.
  • 16
    Beer KL, Lombardi AV Jr, Mallory TH, Vaughn BK. The efficacy of suction drains after routine total joint arthroplasty. J Bone Joint Surg Am. 1991:73(4):584-7.
  • 17
    Reilly TJ, Gradisar IA Jr, Pakan W, Reilly M. The use of postoperative suction drainage in total knee arthroplasty. Clin Orthop Relat Res. 1986;(208):238-42.
  • 18
    Cobb JP. Why use drains? J Bone Joint Surg Br. 1990:72(6):993-5.
  • 19
    Jenny JY, Boeri C, Lafare S. No drainage does not increase complication risk after total knee prosthesis implantation: a prospective, comparative, randomized study. Knee Surg Sports Traumatol Arthrosc. 2001;9(5):299-301.
  • 20
    Crevoisier XM, Reber P, Noesberger B. Is suction drainage necessary after total joint arthroplasty? A prospective study. Arch Orthop Trauma Surg. 1998;117(3):121-4.
  • 21
    Senda H, Nomura K, Oda M, Hirano M, Sakisaka M, Mizuoka J. Total blood loss in total knee arthroplasty. A comparison of drain-clamped and non drain-clamped operations. [Article in Japanese] Seikeigeka to Saigai Geka. Orthop Traumatol. 1990;37:1739-42.
  • 22
    Roy N, Smith M, Anwar M, Elsworth C. Delayed release of drain in total knee replacement reduces blood loss. A prospective randomised study. Acta Orthop Belg. 2006;72(1):34-8.
  • 23
    Kiely N, Hockings M, Gambhir A. Does temporary clamping of drains following knee arthroplasty reduce blood loss? A randomised controlled trial. Knee. 2001;8(4):325-7.
  • 24
    Stucinskas J, Tarasevicius S, Cebatorius A, Robertsson O, Smailys A, Wingstrand H. Conventional drainage versus four hour clamping drainage after total knee arthroplasty in severe osteoarthritis: a prospective, randomised trial. Int Orthop. 2009;33(5):1275-8.
  • 25
    Shen PC, Jou IM, Lin YT, Lai KA, Yang CY, Chern TC. Comparison between 4-hour clamping drainage and nonclamping drainage after total knee arthroplasty. J Arthroplasty. 2005;20(7):909-13.
  • 26
    Raleigh E, Hing CB, Hanusiewicz AS, Fletcher SA, Price R. Drain clamping in knee arthroplasty, a randomized controlled trial. ANZ J Surg. 2007;77(5):333-5.
  • 27
    Prasad N, Padmanabhan V, Mullaji A. Comparasion between two methods of drain clamping after total knee arthroplasty. Arch Orthop Trauma Surg. 2005;125(6):381-4.
  • 28
    Tai TW, Yang CY, Jou IM, Lai KA, Chen CH. Temporary drainage clamping after total knee arthroplasty: a metaanalysis of randomized controlled trials. J Arthroplasty. 2010;25(8):1240-5.

Publication Dates

  • Publication in this collection
    May/June 2013

History

  • Received
    18 Jan 2012
  • Accepted
    03 Aug 2012
Sociedade Brasileira de Ortopedia e Traumatologia Al. Lorena, 427 14º andar, 01424-000 São Paulo - SP - Brasil, Tel.: 55 11 2137-5400 - São Paulo - SP - Brazil
E-mail: rbo@sbot.org.br