Acessibilidade / Reportar erro

Transaxillary single-port subtotal parathyroidectomy: feasibility study in cadavers

ABSTRACT

Objective :

to test the minimally invasive technique of single-port transaxillary subtotal parathyroidectomy in non-formalized cadavers to evaluate its viability and reproduction.

Method :

we performed ten subtotal parathyroidectomies through a transaxillary TriPort access in cadavers. The technique consisted of access through the axillary fossa, creating a subcutaneous tunnel to the anterior cervical region, for handling of the thyroid gland and dissection and resection of the parathyroid glands.

Results :

all surgeries were successful. The mean time of surgery was 65 minutes (57-79 min), with uncomplicated identification of all anatomical structures. There was no need for complementary incisions in the cervical region.

Conclusion :

the transaxillary single-port subtotal parathyroidectomy technique was feasible and reproducible, suggesting an alternative for minimally invasive cervical surgery.

Keywords:
Parathyroidectomy; Endoscopy; Cadaver; Minimally Invasive Surgical Procedures.

Colégio Brasileiro de Cirurgiões Rua Visconde de Silva, 52 - 3º andar, 22271- 090 Rio de Janeiro - RJ, Tel.: +55 21 2138-0659, Fax: (55 21) 2286-2595 - Rio de Janeiro - RJ - Brazil