Efficiency of cleaning and disinfection of surfaces: correlation between assessment methods

Eficiencia de la limpieza y desinfección de superficies: correlación entre métodos de evaluación

ABSTRACT

Objective:

to assess the correlation among the ATP-bioluminescence assay, visual inspection and microbiological culture in monitoring the efficiency of cleaning and disinfection (C&D) of high-touch clinical surfaces (HTCS) in a walk-in emergency care unit.

Method:

a prospective and comparative study was carried out from March to June 2015, in which five HTCS were sampled before and after C&D by means of the three methods. The HTCS were considered dirty when dust, waste, humidity and stains were detected in visual inspection; when ≥2.5 colony forming units per cm2 were found in culture; when ≥5 relative light units per cm2 were found at the ATP-bioluminescence assay.

Results:

720 analyses were performed, 240 per method. The overall rates of clean surfaces per visual inspection, culture and ATP-bioluminescence assay were 8.3%, 20.8% and 44.2% before C&D, and 92.5%, 50% and 84.2% after C&D, respectively (p<0.001). There were only occasional statistically significant relationships between methods.

Conclusion:

the methods did not present a good correlation, neither quantitative nor qualitatively.

Descriptors:
Equipment Contamination; Housekeeping; Nursing Audit; Health Facility Environment; Infectious Disease Transmission