Acessibilidade / Reportar erro

Application of tuned-mass dampers to the control of floor vibrations

Abstract

This article proposes a standardized solution for the application of Tuned-Mass Dampers to the control of floor vibrations based on the characteristics of the acting loads associated to human usage and the characteristics of the most common structures of the contemporary engineering practice. In order to simplify its usage by the technical community, the tuning is proposed through the selection of pre-determined components for the assembly of the TMD and the choice of disposition and spacing of the mechanisms. The system efficacy is then verified through the computational case study of a floor before and after the application of the mechanisms.

Keywords:
tuned-mass damper; TMD; vibrations; floor; comfort

Resumo

Este artigo propõe uma solução padronizada de aplicação de Tuned-Mass Dampers (TMD) para controle de vibrações em lajes baseada na análise das características de carregamentos associados à utilização humana e nas características estruturais mais comuns à engenharia contemporânea. De modo a simplificar sua aplicação técnica, a sintonização é proposta por meio da escolha de componentes pré-determinados para a montagem do TMD e pela distribuição e posicionamento dos mecanismos. A eficácia do sistema é então verificada por meio de um estudo computacional de caso de uma laje antes e depois da aplicação dos mecanismos.

Palavras-chave:
tuned-mass damper; TMD; vibrações; lajes; conforto

1. Introduction

Tuned-Mass Dampers, TMD’s, are highly efficient systems utilized in the passive control of structural vibrations. They basically consist of an inertial element connected through a damper and a spring to a system to alter its dynamic characteristics. Its operational principle is based on the idea that the TMD resonates in an excitation frequency that coincides to a vibration mode of the structure, thus dissipating the energy that would otherwise act unchecked. This characteristic of the Tuned-Mass Dampers, however, demands that they are tuned to each system, reducing its employability in the contemporary civil engineering practice, which remains reluctant about adopting dynamic concepts in the design of structures. A possibility is thus presented for a standardized solution against recurring vibrational problems to which the applicability of traditional static approaches, such as the increase in stiffness, might be inefficient or unviable. In the case of slab vibrations, the situation is even more critical due to the architectonic demands for larger spans and the ever-increasing use of light partitions, that contribute little to the stiffness and damping of the system unlike the masonry partitions. As such, the development of a set of standardized Tuned-Mass Dampers is proposed, as well as a simplified design guide that will allow the proper tuning for slabs of different sizes, thickness and usages, in a way that facilitates its usage in the contemporary practice.

1.1 Justification

According to the AISC Steel Design Guides Series 11: Floor Vibrations Due to Human Activity, the human response to floor vibrations is a fairly complex phenomenon that depends, among other factors, of the amplitude of displacements and accelerations one is submitted to, as well as of the current location, user sensitivity and of the nature of the load that originated the vibration. Also, the user reaction is strongly tied to the activities performed in said locations. Users located in residences and offices are troubled by any perceptible vibration, which means any acceleration that surpasses 0,50% of the gravity, while those located in places in which more energetic activities take place are capable of accepting vibrations of up to 5,00% of the gravity. Users in intermediary situations, such as dining beside a ballroom or weightlifting beside a fitness class, or even shopping in a shopping center tolerate intermediary values of acceleration, around 1,50% of the gravity, depending also on the duration of the vibration and the distance from the source. Those limits, however are only valid for vibrations that have their frequencies between 4,0Hz and 8,0Hz, range beyond which users are capable of dealing with greater accelerations.

Throughout the years, many criteria were proposed in order to ascertain the level of human comfort of a set of floors under dynamic effects, being that the AISC divides them in relation to the kind of considered excitation: rhythmic or due to walking. The criteria currently recommended for vibrations due to walking, estimation methods of the required properties and design procedures were initially devised by Allen and Murray, and they differ extensively from the previous analysis based on the “heel-drop test”, in which the natural frequencies and damping ratios of the system are ascertained due to the impact created by a person of about 75,0kg that stands on his toes, lifting the heels about 60mm from the floor and then allow them to hit the floor with full weight. Despite the criteria of Allen and Murray being more complex than the previous, they have a wider range of uses and result in more economic acceptable floors. Using them as basis with a few minor modifications to allow a more embracing application, the Design Guide 11 is based on the dynamic response of a system of floors bore by beams under the loads originated due to walking and can be used to design offices, malls and footbridges, among others. The accelerations are limited in accordance to the recommendations of the International Standards Organization (ISO 2631-2, 1989[6] INTERNATIONAL STANDARDS ORGANIZATION. INTERNATIONAL STANDARD ISO 2631-2: Evaluation of Human Exposure to Whole-Body Vibration-Part 2: Human Exposure to Continuous and Shock-Induced Vibrations in Buildings (1 to 80 Hz). 1989.) adjusted for the intended occupancy. Limits are suggested in terms of root mean square values of acceleration as multiples of the baseline curve presented in Figure [1], which are proposed for offices, malls and indoors footbridges, and outdoors footbridges, defined by multiplying the baseline by 10, 30 and 100, respectively. For design purposes, the limits can be assumed to range between 0,80 and 1,50 times the recommended values depending on the duration of the vibration and its frequency.

Figure 1
Recommended peak acceleration for human comfort for vibrations due to human activities (AISC Steel Design Guides Series 11; Allen e Murray, 1993; ISO 2631-2: 1989[6] INTERNATIONAL STANDARDS ORGANIZATION. INTERNATIONAL STANDARD ISO 2631-2: Evaluation of Human Exposure to Whole-Body Vibration-Part 2: Human Exposure to Continuous and Shock-Induced Vibrations in Buildings (1 to 80 Hz). 1989.)

The dynamic analysis of vibrations due to walking is performed according a time dependent harmonic force component that matches the fundamental frequency of the floor, according to the Equation [1].

F i = P α i cos ( 2 π i f s t e p t ) (1)

where

P = person´s weight, taken as 0,7kN for design.

i = harmonic multiple of the step frequency.

fstep = step frequency.

αi = dynamic coefficient for the ith harmonic force component. Recommended values are given in Table [1], however, only a single harmonic is considered at a time since the others would be negligible in comparison to the resonant harmonic.

Table 1
Common excitation frequencies and their respective dynamic coefficients (AISC Steel Design Guides Series 11)

As such, the resonant response function is given by the Equation [2].

a g = R α i P β W cos ( 2 π i f s t e p t ) (2)

in which:

ag = ratio of the floor acceleration to the acceleration of gravity.

β = modal damping ratio.

W = effective weight.

R = reduction factor that accounts for the fact that full steady-state resonant motion is not achieved for walking and that the excitation source and the affected user are not simultaneously at the location of maximum modal displacement. Taken as 0,7 for footbridges and 0,5 for floor structures with two-way mode shape configurations.

For frequencies above 8Hz, the quasi-static deflection and footstep impulse vibration can become more critical than resonance. To account for these effects, the AISC recommends that the acceleration should be limited to the same values as the frequencies ranging from 4,0Hz to 8,0Hz and a minimum stiffness of 1kN/mm under concentrated loads should be respected for vibrations of frequencies greater than 10,0Hz. These criteria, however, are not valid in case equipment sensitive to vibrations are affected.

When considering rhythmic excitations, the design criteria for structures is based on the dynamic response of the structure under loads distributed over the whole floor. They may be used in the evaluation of structural systems submitted to activities such as gymnastics, aerobic and dance classes on the condition that the loading function is known. The peak acceleration of the floor due to harmonic excitations is obtained from the Equation [3] through the classic solution by assuming that the structure presents a single mode of vibration.

a p g = 1,3 α i w p w t [ ( f n f ) 2 1 ] 2 + [ 2 β f n f ] 2 (3)

where:

αi = dynamic coefficient (see Table [1])

wp = effective weight per unit area of participants distributed over floor panel.

wt = effective weight per unit area of floor panel, including users.

fn = natural frequency of the floor (Hz).

f = excitation frequency (Hz).

β = damping ratio.

The effective maximum acceleration accounting for all the harmonic can, then, be calculated from the Equation [4].

a m = [ a i 1,5 ] 0,667 (4)

In which ai represents the peak acceleration for the ith harmonic.

The damping associated to floor panels is originated from the non-structural components, furniture and occupants. Damping ratios recommended by the Design Guide range from 0,01 to 0,06. For footbridges or locations with low occupancy with no furniture nor non-structural components, the damping ratio should be considered 0,01; in case of floors with few non-structural components and furniture such as shopping centers and churches the recommended value is 0,02. A damping ratio of 0,03 is adequate for floors with non-structural components and furnishings, but with only small demountable partitions, such as modular offices; while a damping ratio of 0,05 should be considered for floors and homes with full height fixed partitions; and a ratio of 0,06 is recommended for vibrations caused by rhythmic excitation due to a great accumulation of people since the users themselves contribute to the damping.

Another important factor to the dynamic analysis of a slab is its own distributed weight, that must be carefully estimated in its actual value for both the live and dead loads, not the design loads. According to the AISC, the live loads should be taken as 0,50kN/m² for offices and 0,25kN/m² for homes, while footbridges, gymnasiums and shopping centers the live load should be taken as 0kN/m².

The application of these criteria, however, demands careful consideration from the engineer. For instance, the acceleration limit for outdoor footbridges is meant for high traffic of people, not quiet places such as office atria.

2. Methodology

2.1 Definition of the standard TMD characteristics

The basic elements of the proposed TMD can be ascertained from the previously mentioned criteria, and from among the possibilities some will be chosen as standard in a way that covers the greatest range of cases with the least amount of parts. The first elements to be defined are the standard masses. Assuming that the mass of the Tuned-Mass Dampers is contained exclusively on its inertial element, their mass can be obtained from the distributed weight of the structure common on the contemporary practice and desired spacing between mechanisms. Taking in account slabs of 10,0cm, 15,0cm and 20,0cm of height, floor coverings of 100,0kg/m² or 200kg/m² and live loads varying from 0,0kg/m² to 50,0kg/m², the possible distributed weights are shown in Table [2].

Table 2
Possible distributed weights considered

For each possibility of distributed weight, the adequate element mass can be ascertained from the distribution of the mechanisms through the floor and the ratio μ between the system and structure weights given in Equation [5].

μ = M s e t o f T M D ' s M s t r u c t u r e (5)

The CEB suggest in its Bulletin D´Information N209, annex D, that μ should usually range from 1,0% to 5,0%, while Varela and Batista (2011)[7] VARELA, Wendell D.; BATTISTA, Ronaldo C.. Control of vibrations induced by people walking on large span composite floor decks. Engineering Structures. p. 2485-2494. set. 2011. recommends it should range between 0,2% to 1,0%. As such, the inertial elements are ascertained assuming μ=1,0% and spacing of 0,50m between mechanisms. From the values thus obtained, shown in Table [3], the options of 0,75kg, 1,00kg, 1,25kg, 1,50kg and 1,75kg are chosen as the standard masses of the inertial elements in order to better cover the intended range.

Table 3
Calculated mass of the inertial elements of the TMD for the distributed weights considerer

Next, the spring stiffness can be defined. Since the TMD’s are damped mass-spring oscillators of a single degree of freedom, their natural frequency obeys Equation [6].

f T M D = 1 2 π k m (6)

where:

fTMD = natural frequency of the Tuned-Mass Damper.

k = system (spring) stiffness.

m = mass of the inertial element.

The application of TMDs, however, increases the system mass without an equivalent increase in its stiffness, slightly reducing its natural frequency. To compensate this deviation in a simplified manner, the tuning is done for a rectified frequency through Equation [7].

f t u n i n g = 1 1 + μ f n a t u r a l f l o o r (7)

in which:

ftuning= rectified natural frequency of the system.

fnaturalfloor= original natural frequency of the system.

According to the AISC the excitation frequency of excitation loads ranges from 1,60Hz to 2,20Hz for walking, 2,00 Hz to 2,75Hz for aerobic classes and 1,50Hz to 3,00Hz for dancing. The necessary springs to comprise the whole range of excitation and their harmonics can be obtained using Equations [6] and [7], and are indicate in Table [4]. Among the resulting stiffness, fifteen are selected as standard: 100N/m, 150N/m, 225N/m, 330N/m, 500N/m, 630N/m, 790N/m, 1000N/m, 1235N/m, 1500N/m, 1780N/m, 2050N/m, 2350N/m, 2700N/m e 3100N/m; that, together with the standard masses previously selected, allow the tuning of the mechanism to the exact frequencies indicated in Table [5].

Table 4
Calculated stiffness of the springs of the TMD based on the inertial element and frequencies selected

Table 5
Possible rectified natural frequencies for the mass-spring combinations of the standard TMD

Lastly, the standard dampers must be defined. According to the Bulletin D´Information N209, annex D, the optimum damping ratio of a Tuned-Mass Damper can be obtained in a simplified manner from the Equation [8].

ξ o p t i m u m = [ 3 μ 8 ( 1 + μ ) 3 ] 1 / 2 (8)

where ξ is calculated from Equation [9].

ξ = c 2 m ϖ (9)

in which:

c = the damping coefficient.

m = mass of the inertial element.

ω = natural angular frequency of the TMD.

The ideal damping coefficient for each mass and frequency combination are given in Table [6]. Among those, 1,00Ns/m, 1,75Ns/m, 2,50Ns/m, 3,25Ns/m, 4,00Ns/m, 4,60Ns/m, 5,20Ns/m, 6,00Ns/m, 7,00Ns/m e 8,00Ns/m were chosen as standard to better comprise the range of interest.

Table 6
Ideal damping coefficient for the considered spring-frequency combinations

In short, the Tuned-Mass Damper to be used can be applied basically to any case within the analyzed spectrum through the compounding of the mechanism from five possible weights, fifteen springs and ten dampers, respectively indicated in Tables [7], [8] and [9].

Table 7
Mass of the standard inertial elements (weights)

Table 8
Stiffness of the standard restorative elements (springs)

Table 9
Damping coefficient of the standard dissipative elements (dampers)

2.2 Guide for parts selection of the tuned-mass damper

After recognizing the vibration problems on the floor, the assemblage of the TMD is straightforward and simples. Initially, the equivalent distributed weight is ascertained, in kg/m², from the sum of the weight of the slab, floor covering and live load in their actual values. The ideal inertial element for the mechanism can, thus, be calculated by multiplying this value by μ=1,00% and the influence area of each TMD, that is, the area obtained from the spacing of each adjacent mechanism, as demonstrated in Equation [10].

M T M D c a l c u l a t e d = μ [ ( h s l a b ρ c o n c r e t e + h f . c o v e r i n g ρ f . c o v e r i n g + Q A I S C ) d x d y ] (10)

na qual:

μ is taken as 1,00%;

hslab = slab height (m);

hf. covering = floor covering height (m);

ρconcrete = reinforced concrete density (kg/m³);

ρf. covering = density of the floor covering (kg/m³);

QAISC = equivalent weight of the live loads used for dynamic analysis (recommended by the AISC Design Guide 11 as approximately 50kg/m² for offices, 25kg/m² for houses and 0kg/m² for footbridges, gymnasiums and shopping centers);

dx = spacing between TMD’s in the main direction of the slab (m);

dy = spacing between TMD’s in the secondary direction of the slab (m).

The inertial element is then chosen as the one closest to the calculated value among the options in Table [7]. The next step would then be choosing the spring stiffness, which will be ascertained from the chosen inertial element and the natural frequency of the structure that needs mitigating, as seen in Equation [11], obtained from the Equations [6] and [7]. The resulting stiffness is then used as basis for choosing the spring among the options in Table [8].

k T M D C a l c u l a t e d = [ 2 π ( 1 + µ ) f n a t u r a l f l o o r ] 2 × M T M D A d o p t e d (11)

Lastly, the ideal damping is calculated according to Equation 12 that results from manipulating the Equations [8] and [9]. The damper can then be chosen from the options indicated in Table [9].

c T M D C a l d u l a t e d = [ 3 µ × M T M D A d o p t e d × k T M D A d o p t e d 2 ( 1 + µ ) 3 ] 1 / 2 (12)

2.3 Case analysis

TTo verify the efficacy of the TMD assembled according the process described in the previous item, a case analysis was performed on an office floor made of concrete, fck 40Mpa; height of 10,0cm; spans of 580,0cm by 600,0cm; 2,0cm concrete covering thickness and subjected to the following loads: self-weight of 2500N/m², floor covering of 2000N/m² and live loads of 2000N/m². The resulting moments, obtained using the Tables of Czerny for slabs with four simply supported sides, are mxsd = 10220Nm/m e mysd = 9690Nm/m. Considering CA-50 steel and respecting requirements from the ABNT NBR 6118:2013[2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 6118: Projeto de estruturas de concreto - Procedimento. 2013., the necessary reinforcement of the slabs is 4,65cm²/m on the main direction and 5,18cm²/m on the secondary direction, both satisfied by Φ10c/15cm. The resulting deflection is 19,5mm, less than the required limit of 1/300 if the main span. Next, assuming the slab is held by four beams 20cm wide and 45cm tall, with concrete covering thickness of 2,50cm, the critical beam is submitted to 6700N/m dead load, 3000N/m live load and 2250N/m self-weight with a span of 6,00m. Thus, the resulting moment is Msd = 76640Nm, that, neglecting the slab contribution, requires 4,65cm² reinforcement., satisfied by the adoption of 4Φ12,5. The resulting deflection is 1,23cm and the maximum fissure gap is 0,08mm, both values satisfy the requirements of the NBR 6118:2013[2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 6118: Projeto de estruturas de concreto - Procedimento. 2013.. In short, the structure is compatible with the ABNT requirements for static design.

To Figure the natural frequencies, amplitude of displacements and accelerations of the structural system before and after the setup of the TMD´s, the software Adina 9,1, student license was utilized. A model was created with unities from the International System, a concentrated sinusoidal harmonic load of 700N applied to the center of the slab and fixed supports on its vertices. The following Figures [2] and [3] represent respectively the simple and rendered images of the model as seen in the software.

Figure 2
Modeling of the analyzed floor without TMD’s on the Adina 9,1 software

Figure 3
Rendering of the analyzed floor without TMD’s on the Adina 9,1 software

From the analysis of the model, the following natural frequencies are obtained: 5,62Hz for the first mode, 11,56Hz for the second mode and 11,86Hz for the third mode. Among those, only the first is contained within the range of frequencies generated due to walking and thus the Tuned-Mass Damper will be tuned for 5,62Hz.

The choice of inertial element is done by applying Equation [10] to the case with a dynamic live load of 50kg/m², that is, 500N/m², recommended by the Design Guide for office floors:

M T M D c a l c u l a t e d = 0,01 [ ( 0,10 x 2500 + 200 + 50 ) 0,50 x 0,50 ] = 1,25 k g M T M D a d o p t e d = 1,25 K g

Next, the ideal spring stiffness is ascertained from Equation [11]:

k T M D c a l c u l a t e d = [ 2 π ( 1 + 0,01 ) 5,62 ] 2 × 1,25 = 1528 N / m k T M D a d o p t e d = 1500 N / m

Lastly, the ideal damping is obtained by applying Equation [12] to the case:

c T M D c a l c u l a t e d = [ 3 x 0,01 x 1,25 × 1500 2 ( 1 + 0,01 ) 3 ] 1 / 2 = 5,22 N s / m c T M D a d o p t e d = 5,20 N s / m

A new model is then created with the application of the previously defined Tuned-Mass Dampers under the slab, spaced 0,50m from each other. The natural frequency of this new model is 5,30Hz for the first mode.

To accommodate all the AISC demands, the exciting load is multiplied by an αi coefficient, indicated in Table [1] for each harmonic. This means that the maximum intensity of the excitation load varies from one harmonic to the next. Also, according to the AISC recommendation the damping ratio considered is that of offices, 0,03, and will be considered through the application of Rayleigh Damping, in which the damping ratio is obtained from Equation [13] with two variables, αRayleigh and βRayleigh, and is defined in such a way that results in a value as close as possible to the desired for the greater part of the analyzed range. To guarantee a damping ratio of 0,03 for excitations close the resonance frequency, the Rayleigh damping will be adjusted to present the desired ratio for 4,00Hz and 7,00Hz, which results in the variables αRayleigh = 0,9596 and βRayleigh = 8,68x10-4 and the damping ratio shown in Figure [4]. Then, varying the excitation frequency through the interest range the stabilized displacement and acceleration amplitudes can be obtained.

Figure 4
Resulting Rayleigh damping

ξ n = 1 2 ω n α R a y l e i g h + ω n 2 β R a y l e i g h (13)

3. Results and discussions

The difference in response between the structural systems with and without the application of TMD´s represented in the previous two models can be visualized in the graphics of the Figures [5] and [6] that present the root mean square values of the acceleration and displacement in the center of the slab for the stabilized harmonic system respectively. Based in those results, the reduction of the resonant amplitude of displacement and acceleration is clear. The root mean square values of both are reduced close to 65% for the exciting frequency of 5,6Hz, the displacement diminishing from 0,165mm to 0,057mm and the acceleration is reduced from 0,204m/s² to 0,07m/s². It should be noted that even though those results seem negligible in the first place, the displacement is based only on a single concentrated load of 700N, much lesser than the real loading; and the acceleration with and without TMD´s represent 2,06% and 0,71% of the gravity respectively, while the acceleration limit for offices should range from 0,40% and 0,75%. Also, in Figures [5] and [6] the noncontinuities that occur for 2,20Hz, 4,40Hz and 6,60Hz are caused by the change of the coefficient αi of each harmonic. The difference in behavior of the structural system before and after the setup of the TMD´s is clear not only due to the reduction of the dynamic response at the resonance frequency but also due to the emergence of two new dynamic peaks besides the new generated valley, which actually possess worse dynamic response than the original system. The presence of those peaks, however, was already expected as a side effect of the use of Tuned-Mass Dampers and is lessened by the fact that the two new maximums are dwarfed when compared to the original peak. To better represent this behavior, the graphic of Figure [7] indicates the efficacy of the use of the TMD´s by directly comparing the results with and without the mechanisms for the whole range of analyzed excitation frequencies.

Figure 5
Root mean value of displacement x frequency

Figure 6
Root mean value of acceleration x frequency

Figure 7
Relation Between the systems amplitude with and without TMD’s

4. Conclusion

This study indicates a reduction of about 65% of the root mean square values of acceleration, proving the efficiency of the suggest solution. Another advantage of said method are its relative easiness of use and installation. This study, however, was limited to a single case, making it necessary to develop new models that account for a broader range of typical structural engineering situations, with different occupancies, geometric shapes and spans.

5. Acknowledgements

This study was possible due to the support of ADINA R&D. Inc that freely provided the Adina 9,1 software, 900 nodes edition, for students from all over the world

6. Bibliographic References

  • [1]
    AMERICAN INSTITUTE OF STEEL CONSTRUCTION, INC. STEEL DESIGN GUIDE SERIES 11: Floor Vibrations Due to Human Activity. 2003.
  • [2]
    ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 6118: Projeto de estruturas de concreto - Procedimento. 2013.
  • [3]
    BATHE, Klaus-Jürgen. Finite Element Procedures. 14. ed. :Prentice Hall, 1996.
  • [4]
    CLOUGH, Ray W.; PENZIEN, Joseph. Dynamics of Structures. Mcgraw-Hill International Book Company, 1982.
  • [5]
    COMITÉ EURO-INTERNATIONAL DU BÉTON. BULLETIN D'INFORMATION N209: Vibration Problems in Structures. 1991.
  • [6]
    INTERNATIONAL STANDARDS ORGANIZATION. INTERNATIONAL STANDARD ISO 2631-2: Evaluation of Human Exposure to Whole-Body Vibration-Part 2: Human Exposure to Continuous and Shock-Induced Vibrations in Buildings (1 to 80 Hz). 1989.
  • [7]
    VARELA, Wendell D.; BATTISTA, Ronaldo C.. Control of vibrations induced by people walking on large span composite floor decks. Engineering Structures. p. 2485-2494. set. 2011.

Publication Dates

  • Publication in this collection
    Apr 2018

History

  • Received
    10 June 2016
  • Accepted
    25 Sept 2017
IBRACON - Instituto Brasileiro do Concreto Instituto Brasileiro do Concreto (IBRACON), Av. Queiroz Filho, nº 1700 sala 407/408 Torre D, Villa Lobos Office Park, CEP 05319-000, São Paulo, SP - Brasil, Tel. (55 11) 3735-0202, Fax: (55 11) 3733-2190 - São Paulo - SP - Brazil
E-mail: arlene@ibracon.org.br