The behavior under fire conditions of composite steel and concrete beams, not subjected to local buckling (compact steel profile), was studied considering the support rotational stiffness provided by the upper longitudinal slab reinforcement, usually present by means of anti-cracking meshes, and restriction of the steel profile’s lower flange, additional procedure required for development of the support bending moment resistance. Usually composite beams at room temperature are designed as simply supported and the semi-rigidity provided by this longitudinal reinforcement, if considered under fire conditions, may lead to a lower cost solution for fire protection of composite beams. The purpose of this study is to verify the viability of this proposal, using simplified design code methods.