Acessibilidade / Reportar erro

Micro-CT analysis of filling ability and porosity of root-end filling materials

Análise em micro-CT da capacidade de preenchimento e porosidade de materiais retrobturadores

Abstract

Introduction

Filling ability of retrograde cavity and porosity are important properties for root-end filling materials and may be evaluated by using microcomputed tomography (micro-CT).

Objective

To evaluate filling ability and porosity of root-end filling materials using microcomputed tomography (micro-CT).

Material and method

Cavities with 1 mm internal diameter and 3 mm depth were prepared in bovine dentin sections by using ultrasonic tips (CVD No. 6.1107-6), and filled by Mineral Trioxide Aggregate (MTA); Sealer 26 (S26) and zinc oxide and eugenol cement (ZOE). Before and after filling, cavities were scanned by using micro-CT (SkyScan 1176). Filling and porosity were analyzed by using CTAn software. Filling ability was calculated based on volumetric percentage of the filled cavity. The number and percentage of closed pores were measured throughout entire extension of the filled cavity (total) and in each third (cervical, middle and apical), by using bi and tridimensional analyses. The filling data were submitted to ANOVA and Tukey statistical tests, and porosity data to Kruskall-Wallis and Dunn tests, at a 5% significance level.

Result

S26 and ZOE presented higher filling ability than MTA (p<0.05). S26 showed the highest total porosity (number and percentage) (p<0.05). In all thirds after 2D and 3D analyses, porosity was higher for S26 in comparison to MTA and ZOE (p<0.05).

Conclusion

Although Sealer 26 presented more porosity, the material was associated with a great filling ability. Micro-CT analysis showed no correlation between filling ability and porosity.

Descriptors:
X-Ray Microtomography; porosity; dental materials; endodontics

Resumo

Introdução

Capacidade de preenchimento da cavidade retrógrada e porosidade são propriedades importantes de materiais retrobturadores e podem ser avaliadas por meio de microtomografia computadorizada (micro-CT).

Objetivo

Avaliar a capacidade de preenchimento e porosidade de materiais retrobturadores por meio de micro-CT.

Material e método

Cavidades com 1 mm de diâmetro e 3 mm de altura foram preparadas em dentina bovina utilizando pontas ultrassônicas (CVD No. 6.1107-6) e foram preenchidas com Mineral Trióxido Agregado (MTA), Sealer 26 (S26) e cimento de óxido de zinco e eugenol (OZE). As cavidades foram escaneadas em micro-CT antes e após o preenchimento. A capacidade de preenchimento foi calculada com base na porcentagem em volume, das cavidades preenchidas. O número e porcentagem dos poros fechados foram avaliados em toda extensão da cavidade preenchida (total) e por terços (cervical, médio e apical) por meio de análises bi e tridimensionais. Os dados de preenchimento foram submetidos aos testes estatísticos ANOVA e Tukey e a porosidade aos testes de Kruskall-Wallis e Dunn, com nível de significância de 5%.

Resultado

S26 e OZE apresentaram maior capacidade de preenchimento que o MTA (p<0,05). S26 mostrou maior porosidade total (em número e porcentagem) (p<0,05). Em todos os terços, após as análises 2D e 3D, a porosidade foi maior para S26 em comparação ao MTA e OZE (p<0,05).

Conclusão

Embora Sealer 26 tenha apresentado maior porosidade, o material foi associado a uma adequada capacidade de preenchimento. A análise em micro-CT mostrou ausência de correlação entre capacidade de preenchimento e porosidade.

Descritores:
Microtomografia por Raio-X; porosidade; materiais dentários; endodontia

INTRODUCTION

Microcomputed tomography (micro-CT) is a non-destructive tool used for different studies in Endodontics as analysis of root canal filling11 Jung M, Lommel D, Klimek J. The imaging of root canal obturation using micro-CT. Int Endod J. 2005 Sep;38(9):617-26. PMid:16104975. http://dx.doi.org/10.1111/j.1365-2591.2005.00990.x.
http://dx.doi.org/10.1111/j.1365-2591.20...
, filling ability of the reparative materials22 Torres FFE, Bosso-Martelo R, Espir CG, Cirelli JA, Guerreiro-Tanomaru JM, Tanomaru-Filho M. Evaluation of physicochemical properties of root-end filling materials using conventional and Micro-CT tests. J Appl Oral Sci. 2017 Jul-Aug;25(4):374-80. PMid:28877275. http://dx.doi.org/10.1590/1678-7757-2016-0454.
http://dx.doi.org/10.1590/1678-7757-2016...
and the evaluation of interface material/dentin associated with different root canal filling techniques and materials33 Gandolfi MG, Parrilli AP, Fini M, Prati C, Dummer PM. 3D micro-CT analysis of the interface voids associated with Thermafil root fillings used with AH Plus or a flowable MTA sealer. Int Endod J. 2013 Mar;46(3):253-63. PMid:23039158. http://dx.doi.org/10.1111/j.1365-2591.2012.02124.x.
http://dx.doi.org/10.1111/j.1365-2591.20...
. Micro-CT is also used for evaluating the volumetric change in endodontic materials, with possible correlation with solubility44 Cavenago CB, Pereira TC, Duarte MA, Ordinola-Zapata R, Marciano MA, Bramante CM, et al. Influence of powder to-water ratio on radiopacity, setting time, pH, calcium ion release, and a micro-CT volumetric solubility of white mineral trioxide aggregate. Int Endod J. 2014 Feb;47(2):120-6. PMid:23647286. http://dx.doi.org/10.1111/iej.12120.
http://dx.doi.org/10.1111/iej.12120...
and dimensional change after immersion in distilled water22 Torres FFE, Bosso-Martelo R, Espir CG, Cirelli JA, Guerreiro-Tanomaru JM, Tanomaru-Filho M. Evaluation of physicochemical properties of root-end filling materials using conventional and Micro-CT tests. J Appl Oral Sci. 2017 Jul-Aug;25(4):374-80. PMid:28877275. http://dx.doi.org/10.1590/1678-7757-2016-0454.
http://dx.doi.org/10.1590/1678-7757-2016...
.

The porosity of a material may be affected by physicochemical properties. Cements with absence of macropores and lower porosity may present less penetration of oral fluids, bacteria and bacterial toxins into root canal55 Milutinović-Nikolić AD, Medić VB, Vuković ZM. Porosity of different dental luting cements. Dent Mater. 2007 Jun;23(6):674-8. PMid:16860859. http://dx.doi.org/10.1016/j.dental.2006.06.006.
http://dx.doi.org/10.1016/j.dental.2006....
. Pores in sealers appear to be originated from the air trapped in the mass of cement during handling manipulation66 Mutal L, Gani O. Presence of pores and vacuoles in set endodontic sealers. Int Endod J. 2005 Oct;38(10):690-6. PMid:16164682. http://dx.doi.org/10.1111/j.1365-2591.2005.00988.x.
http://dx.doi.org/10.1111/j.1365-2591.20...
. Porosity may be analyzed by means of microscopy, using porosimetry by mercury intrusion77 Camilleri J, Grech L, Galea K, Keir D, Fenech M, Formosa L, et al. Porosity and root dentine to material interface assessment of calcium silicate-based root-end filling materials. Clin Oral Investig. 2014;18(5):1437-46. PMid:24100638. http://dx.doi.org/10.1007/s00784-013-1124-y.
http://dx.doi.org/10.1007/s00784-013-112...
, or by using microcomputed tomography88 Kerckhofs G, Schrooten J, Van Cleynenbreugel T, Lomov SV, Wevers M. Validation of x-ray microfocus computed tomography as an imaging tool for porous structures. Rev Sci Instrum. 2008 Jan;79(1):013711. PMid:18248043. http://dx.doi.org/10.1063/1.2838584.
http://dx.doi.org/10.1063/1.2838584...
,99 N’Diaye M, Degeratu C, Bouler JM, Chappard D. Biomaterial porosity determined by fractal dimensions, succolarity and lacunarity on microcomputed tomographic images. Mater Sci Eng C Mater Biol Appl. 2013 May;33(4):2025-30. PMid:23498228. http://dx.doi.org/10.1016/j.msec.2013.01.020.
http://dx.doi.org/10.1016/j.msec.2013.01...
. De Souza et al.1010 De Souza ET, Nunes Tameirão MD, Roter JM, De Assis JT, De Almeida Neves A, De-Deus GA. Tridimensional quantitative porosity characterization of three set calcium silicate-based repair cements for endodontic use. Microsc Res Tech. 2013 Oct;76(10):1093-8. PMid:23913667. http://dx.doi.org/10.1002/jemt.22270.
http://dx.doi.org/10.1002/jemt.22270...
, using a 3D model, quantitatively evaluated the degree of porosity of calcium-silicate based materials analyzing the images obtained by microcomputed tomography. 3D models were evaluated and the porosity parameters of each material were obtained by comparison with standard porosity values of Biodentine®. This tool allows a tridimensional mensuration (with volumetric results – mm3) of failures. Surface area, volumetric analysis, the amount of pores and specific characteristics of these structures can be assessed.

Clinically, these physical properties of root-end filling materials are relevant. High porosity values for endodontic materials may affects its physical properties77 Camilleri J, Grech L, Galea K, Keir D, Fenech M, Formosa L, et al. Porosity and root dentine to material interface assessment of calcium silicate-based root-end filling materials. Clin Oral Investig. 2014;18(5):1437-46. PMid:24100638. http://dx.doi.org/10.1007/s00784-013-1124-y.
http://dx.doi.org/10.1007/s00784-013-112...
, besides increasing the leakage55 Milutinović-Nikolić AD, Medić VB, Vuković ZM. Porosity of different dental luting cements. Dent Mater. 2007 Jun;23(6):674-8. PMid:16860859. http://dx.doi.org/10.1016/j.dental.2006.06.006.
http://dx.doi.org/10.1016/j.dental.2006....
. A better sealing can be obtained using a material presenting low disintegration and solubility1111 Carvalho-Júnior JR, Guimarães LFL, Correr-Sobrinho L, Pécora JD, Sousa-Neto MD. Evaluation of solubility, disintegration, and dimensional alterations of a glass ionomer root canal sealer. Braz Dent J. 2003;14(2):114-8. PMid:12964655. http://dx.doi.org/10.1590/S0103-64402003000200008.
http://dx.doi.org/10.1590/S0103-64402003...
and it may be directly related to leakage1212 Chittoni SB, Martini T, Wagner MH, Da Rosa RA, Cavenago BC, Duarte MA, et al. Back-scattered electron imaging for leakage analysis of four retrofilling materials. Microsc Res Tech. 2012 Jun;75(6):796-800. PMid:22147679. http://dx.doi.org/10.1002/jemt.21128.
http://dx.doi.org/10.1002/jemt.21128...
. Also, proper sealing may be related to complete filling of the cavity. Analyzing physicochemical (i.e solubility, pH, filling ability) and biological (i.e biocompatibility, bioactivity) characteristics to the root-end filling material may improve the success of the treatment22 Torres FFE, Bosso-Martelo R, Espir CG, Cirelli JA, Guerreiro-Tanomaru JM, Tanomaru-Filho M. Evaluation of physicochemical properties of root-end filling materials using conventional and Micro-CT tests. J Appl Oral Sci. 2017 Jul-Aug;25(4):374-80. PMid:28877275. http://dx.doi.org/10.1590/1678-7757-2016-0454.
http://dx.doi.org/10.1590/1678-7757-2016...
,44 Cavenago CB, Pereira TC, Duarte MA, Ordinola-Zapata R, Marciano MA, Bramante CM, et al. Influence of powder to-water ratio on radiopacity, setting time, pH, calcium ion release, and a micro-CT volumetric solubility of white mineral trioxide aggregate. Int Endod J. 2014 Feb;47(2):120-6. PMid:23647286. http://dx.doi.org/10.1111/iej.12120.
http://dx.doi.org/10.1111/iej.12120...
,77 Camilleri J, Grech L, Galea K, Keir D, Fenech M, Formosa L, et al. Porosity and root dentine to material interface assessment of calcium silicate-based root-end filling materials. Clin Oral Investig. 2014;18(5):1437-46. PMid:24100638. http://dx.doi.org/10.1007/s00784-013-1124-y.
http://dx.doi.org/10.1007/s00784-013-112...
,1212 Chittoni SB, Martini T, Wagner MH, Da Rosa RA, Cavenago BC, Duarte MA, et al. Back-scattered electron imaging for leakage analysis of four retrofilling materials. Microsc Res Tech. 2012 Jun;75(6):796-800. PMid:22147679. http://dx.doi.org/10.1002/jemt.21128.
http://dx.doi.org/10.1002/jemt.21128...
.

Mineral Trioxide Aggregate (MTA) is a biocompatible calcium silicate-based material with capacity to induce repair by mineralized tissue1313 Tanomaru-Filho M, Luis MR, Leonardo MR, Tanomaru JM, Silva LA. Evaluation of periapical repair following retrograde filling with different root-end filling materials in dog teeth with periapical lesions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2006 Jul;102(1):127-32. PMid:16831685. http://dx.doi.org/10.1016/j.tripleo.2005.09.008.
http://dx.doi.org/10.1016/j.tripleo.2005...
. However, the fluid consistency makes it difficult to insert MTA into the root-end cavity, and can harm filling and sealing1414 El-Ma’aita AM, Qualtrough AJ, Watts DC. A micro–computed tomography evaluation of Mineral Trioxide Aggregate root canal fillings. J Endod. 2012 May;38(5):670-2. PMid:22515899. http://dx.doi.org/10.1016/j.joen.2012.01.009.
http://dx.doi.org/10.1016/j.joen.2012.01...
. Sealer 26 (S26) is a resin-based endodontic sealer, composed of bismuth oxide, calcium hydroxide and epoxy resin, and requires higher powder/resin proportion to favor insertion into root-end cavities1313 Tanomaru-Filho M, Luis MR, Leonardo MR, Tanomaru JM, Silva LA. Evaluation of periapical repair following retrograde filling with different root-end filling materials in dog teeth with periapical lesions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2006 Jul;102(1):127-32. PMid:16831685. http://dx.doi.org/10.1016/j.tripleo.2005.09.008.
http://dx.doi.org/10.1016/j.tripleo.2005...
. It has excellent sealing properties when used as root-end filling material1515 Siqueira J Jr, Roccas I, Abad E, Castro A, Gahyva S, Favieri A. Ability of three root-end filling materials to prevent bacterial leakage. J Endod. 2001 Nov;27(11):673-5. PMid:11718135. http://dx.doi.org/10.1097/00004770-200111000-00005.
http://dx.doi.org/10.1097/00004770-20011...
, and presents interface adaptation similar to calcium silicate-based cements1616 Amoroso-Silva PA, Marciano MA, Guimarães BM, Duarte MA, Sanson AF, Moraes IG. Apical adaptation, sealing ability and push-out bond strength of five root-end filling materials. Braz Oral Res. 2014;28(1):1-6. PMid:25166765. http://dx.doi.org/10.1590/1807-3107BOR-2014.vol28.0043.
http://dx.doi.org/10.1590/1807-3107BOR-2...
. Zinc oxide and Eugenol cement (ZOE) may also be used with higher powder/liquid proportion1717 Sousa-Neto MD, Guimarães LF, Gariba Silva R, Saquy PC, Pécora JD. The influence of different grades of rosins and hydrogenated resins on the powder-liquid ratio of Grossman cements. Braz Dent J. 1998;9(1):11-8. PMid:9835799., favoring its insertion into root-end cavities.

The aim of this study was to evaluate the filling ability and porosity of root-end filling materials by using microcomputed tomography. The null hypothesis was that there is no difference between the materials, and the properties of porosity and filling ability are associated.

MATERIAL AND METHOD

Sample Preparation

Bovine teeth were used in this study. The coronal portion was removed. The root portion was sectioned into 5mm slices, using an Isomet 1000 (Buehler Ltd., Lake Bluff, IL, USA) machine. On dentine surface of each slice, root-end cavities with standardized dimensions (1.5 mm diameter and 3 mm deep) were prepared by making intermittent forward-backward movements1818 Wuchenich G, Meadows D, Torabinejad M. A comparison between two root end preparation techniques in human cadavers. J Endod. 1994 Jun;20(6):279-82. PMid:7931024. http://dx.doi.org/10.1016/S0099-2399(06)80816-2.
http://dx.doi.org/10.1016/S0099-2399(06)...
using a high-speed 2137 bur (KG SORENSEN, Cotia, SP, Brazil). Ultrasonic tip CVD No 6.1107-6 (CVD-Vale, São José dos Campos/SP, Brazil) coupled to an ultrasonic device CVDentus (CVD-Vale, São José dos Campos/SP, Brazil) was used on the dentinal walls. In order to maintain the same position during the scans, the samples were fixed in culture plates with silicone. Each well of the culture plate was filled with a standard amount of silicone and the samples were placed into this material, at all stages.

Sample Scanning

After cavity preparation, samples with empty cavities were subjected to microtomographic scannings (Micro-CT SkyScan 1176, Bruker micro-CT Kontich, Belgium). The scanning procedure was performed with 50 kV X-ray tube voltages and 800 µA anode current; aluminum filter of 0.5; isotropic voxel of 9 µm; and an evolution cycle of 360°. To standardize the position of samples, specimens were fixed in culture plates with silicone, as already described.

Filling Ability

The prepared cavities were then randomly divided into three groups, according to the material. MTA Angelus (Angelus, Londrina, PR, Brazil) was manipulated by a same operator previously calibrated using powder/liquid proportion of 1g/330µL. S26 (Dentsply, Petropolis, RJ, Brazil) was prepared in a thicker consistency than used as endodontic sealer, in a 4:1 powder/resin proportion (14). ZOE cement (S.S.White Art. Dent. Ltda., Rio de Janeiro, RJ, Brazil) was used in the proportion of 1 g zinc oxide to 0.2 mL eugenol. The cavities were filled with the materials by using a condenser (Trinity, São Paulo, SP, Brazil). Samples were maintained at 37ºC and 100% humidity for three times the material setting time. After this period, each filled sample was subjected to another microtomographic scanning, as previously described.

Filling Ability Analysis

The scanned images were reconstructed by using NRecon software (V1.6.4,7; SkyScan, Belgium). The correction parameters smoothing, beam hardening and ring artefacts were carefully adjusted and maintained for all the periods, using values of 7, 20% and 10, respectively. These image parameters were used for all materials, to standardize the analysis process (scanning, reconstruction and analyzing criteria). After reconstruction, images were analyzed by using CTAn software (V1.11.8; SkyScan, Belgium). To obtain the total volume of material in mm3, the area of interest the region of interest (ROI) was defined by previous tests and a calibrated operator made all the analyzes of each sample, excluding the dentin. The binary value (threshold) was adjusted to assure the analysis of the material and the total volume of the material in mm3 from quantitative analysis was obtained. Filling was determined by calculating the subtracting the initial (empty cavities) from the final (filled cavities) assessed volume of each sample. The results were then converted into percentages based on the initial volume. 3D models from each specimen were carefully obtained by using CTVol software (V2.0, SkyScan, Belgium) to analyze qualitatively the data.

Porosity Analysis

Micro-CT proved to be a powerful nondestructive 3D analysis tool for visualizing the porous internal microstructure33 Gandolfi MG, Parrilli AP, Fini M, Prati C, Dummer PM. 3D micro-CT analysis of the interface voids associated with Thermafil root fillings used with AH Plus or a flowable MTA sealer. Int Endod J. 2013 Mar;46(3):253-63. PMid:23039158. http://dx.doi.org/10.1111/j.1365-2591.2012.02124.x.
http://dx.doi.org/10.1111/j.1365-2591.20...
. So, at this stage, the filled cavities were analyzed by means of CTAn software (V1.11.8; SkyScan, Belgium). The porosity parameters for each sample were measured and number and percentage of closed pores were obtained. Total porosity throughout the entire material extent was determined. The limits of each sample were defined by using the “top” and “bottom” tool (Figure 1A). A circular VOI, measuring average 0.75 x 0.75, was determined to each analyzes to exclude any possible artefact related to the sample border. Thus, approximately 1 mm2 of margin was excluded. The internal portion of the materials was analyzed by the difference in radiopacity. After this, using the software’s porosity tool, the bidimensional total porosity values were obtained, according to number and percentage of closed pores. This feature allows porosity analysis for individual objects in 2D (bidimensional). It has been defined as the area of any spaces fully surrounded by solid, as a percent of the area of solid plus closed pores. Subsequently, by using the 3D (tridimensional) analysis tool, the number and percentage of closed pores were obtained by means of tridimensional data, providing volumetric data. In this case, a closed pore in 3D is a connected assemblage of space voxels that is fully surrounded on all sides in 3D by solid voxels. In addition a tridimensional model of the samples was obtained by using the CTVol software (V2.0, SkyScan, Belgium).

Figure 1
Models used for porosity analysis. (A) Sample analysis for full extent (total porosity); (B) sample analysis for sections (porosity in thirds).

To obtain more precise and specific analysis, sections with smaller thickness were also analyzed. The “top” and “bottom” tool was used to define 0.5mm sections to evaluate the porosity in the different cavity thirds: coronal, middle and apical (Figure 1B). The analysis was performed as previously described. For each third, the number and percentage of closed pores were calculated, and 3D models were obtained.

Data from filling analysis were submitted to ANOVA and the Tukey tests, with 5% significance. Porosity data were submitted to the Kruskall-Wallis test, complemented by the Dunn test, with a level of significance of 5%.

RESULT

Filling Ability

Data obtained for filling volumetric analysis are represented in Table 1. Similar filling ability was observed for S26 and ZOE (p>0.05), and both presented higher values than MTA (p<0.05). 3D model analyses (Figure 2) show similar characteristics for S26 and ZOE, in comparison with MTA.

Table 1
Mean percentage values (± standard deviation) of cavity fillings by different root-end filling materials
Figure 2
Representative micro-CT tree-dimensional reconstructions of the evaluated samples (1 – MTA; 2 – Sealer 26; 3 – Zinc oxide and eugenol cement). Empty cavity (A) and the cavity filled with each material (B).

Porosity

The data obtained for porosity are described in Table 2. 2D and 3D analyses presented similar patterns of comparison among the materials. S26 showed higher values for number and percentage of closed pores considering the total extent or each third analysis (p<0.05). MTA and ZOE cement were similar for all the analyses (p>0.05). Considering absolute values for both tests, the bidimensional analysis showed higher values in percentage and lower values for number of pores, while the tridimensional analysis revealed higher number of pores and a lower percentage. 3D models porosity models for each third were obtained (Figure 3). The higher porosity observed to S26 was clearly observed in the qualitative analysis in comparison with MTA and ZOE, in all thirds evaluated.

Table 2
Porosity values (total number and percentage of closed pores) in cavities filled with different root- end filling materials in 2D and 3D analysis
Figure 3
Representative aspect of material porosities observed in the different evaluated thirds for each evaluated material.

DISCUSSION

Micro-CT volumetric analysis shows that S26 and ZOE cement presented greater filling ability than MTA. The larger powder to resin/liquid used to manipulate S26 and ZOE cement made it possible to increase their consistency, favoring their insertion into the root-end cavity. By using microcomputed tomography, Cavenago et al.44 Cavenago CB, Pereira TC, Duarte MA, Ordinola-Zapata R, Marciano MA, Bramante CM, et al. Influence of powder to-water ratio on radiopacity, setting time, pH, calcium ion release, and a micro-CT volumetric solubility of white mineral trioxide aggregate. Int Endod J. 2014 Feb;47(2):120-6. PMid:23647286. http://dx.doi.org/10.1111/iej.12120.
http://dx.doi.org/10.1111/iej.12120...
evaluated the solubility of MTA with different powder-liquid ratio (4:1, 3:1 and 2:1) before and after immersion in water for 7 days. They observed that the material manipulated with larger quantity of water promoted greater change in volume. Therefore, the difficulty with inserting MTA into the cavity1313 Tanomaru-Filho M, Luis MR, Leonardo MR, Tanomaru JM, Silva LA. Evaluation of periapical repair following retrograde filling with different root-end filling materials in dog teeth with periapical lesions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2006 Jul;102(1):127-32. PMid:16831685. http://dx.doi.org/10.1016/j.tripleo.2005.09.008.
http://dx.doi.org/10.1016/j.tripleo.2005...
cannot be improved by changing the powder/liquid proportion. For this reason, a better fill can be achieved using materials which allow changes in handling, facilitating insertion into the cavity (i.e. S26 and ZOE cement).

Proper cavity filling with a material presenting low disintegration and solubility may allow a better sealing. Favorable sealing ability for some materials may be related to its dimensional stability and filling, which led to less leakage1111 Carvalho-Júnior JR, Guimarães LFL, Correr-Sobrinho L, Pécora JD, Sousa-Neto MD. Evaluation of solubility, disintegration, and dimensional alterations of a glass ionomer root canal sealer. Braz Dent J. 2003;14(2):114-8. PMid:12964655. http://dx.doi.org/10.1590/S0103-64402003000200008.
http://dx.doi.org/10.1590/S0103-64402003...
. Chittoni et al.1212 Chittoni SB, Martini T, Wagner MH, Da Rosa RA, Cavenago BC, Duarte MA, et al. Back-scattered electron imaging for leakage analysis of four retrofilling materials. Microsc Res Tech. 2012 Jun;75(6):796-800. PMid:22147679. http://dx.doi.org/10.1002/jemt.21128.
http://dx.doi.org/10.1002/jemt.21128...
observed lower bacterial leakage for Sealer 26 in comparison with MTA. Sealer 26 has also demonstrated to prevent bacterial leakage when compared with IRM1515 Siqueira J Jr, Roccas I, Abad E, Castro A, Gahyva S, Favieri A. Ability of three root-end filling materials to prevent bacterial leakage. J Endod. 2001 Nov;27(11):673-5. PMid:11718135. http://dx.doi.org/10.1097/00004770-200111000-00005.
http://dx.doi.org/10.1097/00004770-20011...
. Amoroso-Silva et al.1616 Amoroso-Silva PA, Marciano MA, Guimarães BM, Duarte MA, Sanson AF, Moraes IG. Apical adaptation, sealing ability and push-out bond strength of five root-end filling materials. Braz Oral Res. 2014;28(1):1-6. PMid:25166765. http://dx.doi.org/10.1590/1807-3107BOR-2014.vol28.0043.
http://dx.doi.org/10.1590/1807-3107BOR-2...
demonstrated that Sealer 26, MTA and calcium silicate cements were similar after analyzing sealing by fluid leakage and dentinal adaptation. In the present study, similar filling ability was observed for S26 and ZOE, and both presented higher values than MTA. Torres et al.22 Torres FFE, Bosso-Martelo R, Espir CG, Cirelli JA, Guerreiro-Tanomaru JM, Tanomaru-Filho M. Evaluation of physicochemical properties of root-end filling materials using conventional and Micro-CT tests. J Appl Oral Sci. 2017 Jul-Aug;25(4):374-80. PMid:28877275. http://dx.doi.org/10.1590/1678-7757-2016-0454.
http://dx.doi.org/10.1590/1678-7757-2016...
observed that ZOE presented better filling ability than MTA. Dias et al.1919 Dias HB, Bernardi MIB, Ramos MADS, Trevisan TC, Bauab TM, Hernandes AC, et al. Zinc oxide 3D microstructures as an antimicrobial filler content for composite resins. Microsc Res Tech. 2017 Jun;80(6):634-43. PMid:28271628. http://dx.doi.org/10.1002/jemt.22840.
http://dx.doi.org/10.1002/jemt.22840...
observed that the modification of a composite resin with small amounts of zinc oxide (ZnO) microparticles significantly inhibited the S. mutans growth on resin surface without significant alterations of its mechanical strength. This filling capacity may be related to the better consistency. The results obtained may suggest this relationship. S26 and ZOE cement presented similar characteristics of filling compared to MTA. The presence of space at the interface of the filling material and the root canal wall can result from deficient adaptation of the filling material to the root dentin2020 Prado M, Simao RA, Gomes BP. A microleakage study of gutta-percha/AH Plus and Resilon/Real self-etch systems after different irrigation protocols. J Appl Oral Sci. 2014 Jun;22(3):174-9. PMid:25025557. http://dx.doi.org/10.1590/1678-775720130174.
http://dx.doi.org/10.1590/1678-775720130...
. Despite the excellent properties of MTA, the condensation technique may have some influence in its sealing ability.

Porosity analysis aims to measure the “failure fraction” and empty spaces, counting the spaces and characterizing their connections. The closed pores represent empty spaces completely surrounded by material, which is difficult to be analyzed by conventional methodologies. The use of microcomputed tomography allows evaluation of these faults1010 De Souza ET, Nunes Tameirão MD, Roter JM, De Assis JT, De Almeida Neves A, De-Deus GA. Tridimensional quantitative porosity characterization of three set calcium silicate-based repair cements for endodontic use. Microsc Res Tech. 2013 Oct;76(10):1093-8. PMid:23913667. http://dx.doi.org/10.1002/jemt.22270.
http://dx.doi.org/10.1002/jemt.22270...
. Microtomography has been used to evaluate the porosity of different materials88 Kerckhofs G, Schrooten J, Van Cleynenbreugel T, Lomov SV, Wevers M. Validation of x-ray microfocus computed tomography as an imaging tool for porous structures. Rev Sci Instrum. 2008 Jan;79(1):013711. PMid:18248043. http://dx.doi.org/10.1063/1.2838584.
http://dx.doi.org/10.1063/1.2838584...
,99 N’Diaye M, Degeratu C, Bouler JM, Chappard D. Biomaterial porosity determined by fractal dimensions, succolarity and lacunarity on microcomputed tomographic images. Mater Sci Eng C Mater Biol Appl. 2013 May;33(4):2025-30. PMid:23498228. http://dx.doi.org/10.1016/j.msec.2013.01.020.
http://dx.doi.org/10.1016/j.msec.2013.01...
. Kerckhofs et al.88 Kerckhofs G, Schrooten J, Van Cleynenbreugel T, Lomov SV, Wevers M. Validation of x-ray microfocus computed tomography as an imaging tool for porous structures. Rev Sci Instrum. 2008 Jan;79(1):013711. PMid:18248043. http://dx.doi.org/10.1063/1.2838584.
http://dx.doi.org/10.1063/1.2838584...
aiming to validate micro-CT as an imaging tool for analysis of pores, pointed out errors inherent to the analyses that may result in an incorrect interpretation. Artifacts might influence the quality of the images, challenging image analyses, once the images are reconstructed with several independent detector measurements2121 Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. Radiographics. 2004 Nov;24(6):1679-91. PMid:15537976. http://dx.doi.org/10.1148/rg.246045065.
http://dx.doi.org/10.1148/rg.246045065...
. As an example, streaking artefacts, which happen generally due to an inconsistency in a single measurement; ring artefacts, which appear due to errors in an individual detector calibration, distortion artefacts, due to the geometry of image reconstruction. In order to minimize these errors, all reconstructions were performed using the artifact reduction tools. De Souza et al.1010 De Souza ET, Nunes Tameirão MD, Roter JM, De Assis JT, De Almeida Neves A, De-Deus GA. Tridimensional quantitative porosity characterization of three set calcium silicate-based repair cements for endodontic use. Microsc Res Tech. 2013 Oct;76(10):1093-8. PMid:23913667. http://dx.doi.org/10.1002/jemt.22270.
http://dx.doi.org/10.1002/jemt.22270...
proposed a standard to obtain the threshold, using known values for the porosity of each material. Therefore, the use of microcomputed tomography for porosity analysis also presents variations that must suggest patterns based on the experiment performed and type of sample.

According to the manufacturer (Bruker-microCT, Kontich, Belgium), the CTAn software allows the analysis of porosity of any type of material. In this study, samples were scanned at a high resolution (9um), considered proper for quantifying pores2222 Mendoza F, Verboven P, Mebatsion HK, Kerckhofs G, Wevers M, Nicolai B. Three-dimensional pore space quantification of apple tissue using X-ray computed microtomography. Planta. 2007 Aug;226(3):559-70. PMid:17361459. http://dx.doi.org/10.1007/s00425-007-0504-4.
http://dx.doi.org/10.1007/s00425-007-050...
. During the reconstruction of images, standardized parameters were used in order to decrease artefacts. Analysis of the total sample extent presented more difficulty with defining the parameters, especially the histogram. Therefore, analysis of smaller sections (or thirds) is considered important for correct analysis.

As regards the results of this study, the two measurement analyses showed greater porosity for S26 in comparison with MTA and ZOE cement, for both number and percentage of pores. However, the 2D analyses showed higher percentage values, while the 3D presented a higher number of pores. In microscopic 2D images, a failure may appear as a closed pore, while in the 3D evaluation this pore is considered connected to the external space, which is one advantage of 3D analysis in comparison with conventional methods. Therefore, 3D analysis is indicated for this type of porosity analysis. Bidimensional analysis was evaluated to obtain complementary data. In the present study, bidimensional and tridimensional analysis presented correlated results for material porosities.

The analysis of porosity did not show correlation with filling data, since S26 and ZOE cement promoted greater filling. Otherwise, more porosity was observed for S26 when compared with MTA and ZOE cement, rejecting the null hypothesis. The immediate porosity (after the material set) is related to the material composition and hydration mechanism, especially to water/powder proportion for MTA2323 Camilleri J. Evaluation of selected properties of mineral trioxide aggregate sealer cement. J Endod. 2009 Oct;35(10):1412-7. PMid:19801242. http://dx.doi.org/10.1016/j.joen.2009.07.008.
http://dx.doi.org/10.1016/j.joen.2009.07...
. MTA has demonstrated porosity in different formulations, especially after long evaluation periods33 Gandolfi MG, Parrilli AP, Fini M, Prati C, Dummer PM. 3D micro-CT analysis of the interface voids associated with Thermafil root fillings used with AH Plus or a flowable MTA sealer. Int Endod J. 2013 Mar;46(3):253-63. PMid:23039158. http://dx.doi.org/10.1111/j.1365-2591.2012.02124.x.
http://dx.doi.org/10.1111/j.1365-2591.20...
. The low porosity observed for MTA in the present study may be related to the different methodologies and analysis performed immediately after cavity filling. Mutal, Gani66 Mutal L, Gani O. Presence of pores and vacuoles in set endodontic sealers. Int Endod J. 2005 Oct;38(10):690-6. PMid:16164682. http://dx.doi.org/10.1111/j.1365-2591.2005.00988.x.
http://dx.doi.org/10.1111/j.1365-2591.20...
, after a qualitative analysis of pores in endodontic sealers, including zinc oxide and eugenol cements and Sealer 26, observed that the frequency and size of pores were related to the consistency of the material, and was increased for sealers with calcium hydroxide, such as Sealer 26.

CONCLUSION

Based on the methodology used and the results obtained, we could conclude that Sealer 26 and ZOE cement showed better filling ability in comparison to MTA. On the other hand, Sealer 26 presented porosity higher in number and percentage than MTA and zinc oxide and eugenol.

REFERENCES

  • 1
    Jung M, Lommel D, Klimek J. The imaging of root canal obturation using micro-CT. Int Endod J. 2005 Sep;38(9):617-26. PMid:16104975. http://dx.doi.org/10.1111/j.1365-2591.2005.00990.x
    » http://dx.doi.org/10.1111/j.1365-2591.2005.00990.x
  • 2
    Torres FFE, Bosso-Martelo R, Espir CG, Cirelli JA, Guerreiro-Tanomaru JM, Tanomaru-Filho M. Evaluation of physicochemical properties of root-end filling materials using conventional and Micro-CT tests. J Appl Oral Sci. 2017 Jul-Aug;25(4):374-80. PMid:28877275. http://dx.doi.org/10.1590/1678-7757-2016-0454
    » http://dx.doi.org/10.1590/1678-7757-2016-0454
  • 3
    Gandolfi MG, Parrilli AP, Fini M, Prati C, Dummer PM. 3D micro-CT analysis of the interface voids associated with Thermafil root fillings used with AH Plus or a flowable MTA sealer. Int Endod J. 2013 Mar;46(3):253-63. PMid:23039158. http://dx.doi.org/10.1111/j.1365-2591.2012.02124.x
    » http://dx.doi.org/10.1111/j.1365-2591.2012.02124.x
  • 4
    Cavenago CB, Pereira TC, Duarte MA, Ordinola-Zapata R, Marciano MA, Bramante CM, et al. Influence of powder to-water ratio on radiopacity, setting time, pH, calcium ion release, and a micro-CT volumetric solubility of white mineral trioxide aggregate. Int Endod J. 2014 Feb;47(2):120-6. PMid:23647286. http://dx.doi.org/10.1111/iej.12120
    » http://dx.doi.org/10.1111/iej.12120
  • 5
    Milutinović-Nikolić AD, Medić VB, Vuković ZM. Porosity of different dental luting cements. Dent Mater. 2007 Jun;23(6):674-8. PMid:16860859. http://dx.doi.org/10.1016/j.dental.2006.06.006
    » http://dx.doi.org/10.1016/j.dental.2006.06.006
  • 6
    Mutal L, Gani O. Presence of pores and vacuoles in set endodontic sealers. Int Endod J. 2005 Oct;38(10):690-6. PMid:16164682. http://dx.doi.org/10.1111/j.1365-2591.2005.00988.x
    » http://dx.doi.org/10.1111/j.1365-2591.2005.00988.x
  • 7
    Camilleri J, Grech L, Galea K, Keir D, Fenech M, Formosa L, et al. Porosity and root dentine to material interface assessment of calcium silicate-based root-end filling materials. Clin Oral Investig. 2014;18(5):1437-46. PMid:24100638. http://dx.doi.org/10.1007/s00784-013-1124-y
    » http://dx.doi.org/10.1007/s00784-013-1124-y
  • 8
    Kerckhofs G, Schrooten J, Van Cleynenbreugel T, Lomov SV, Wevers M. Validation of x-ray microfocus computed tomography as an imaging tool for porous structures. Rev Sci Instrum. 2008 Jan;79(1):013711. PMid:18248043. http://dx.doi.org/10.1063/1.2838584
    » http://dx.doi.org/10.1063/1.2838584
  • 9
    N’Diaye M, Degeratu C, Bouler JM, Chappard D. Biomaterial porosity determined by fractal dimensions, succolarity and lacunarity on microcomputed tomographic images. Mater Sci Eng C Mater Biol Appl. 2013 May;33(4):2025-30. PMid:23498228. http://dx.doi.org/10.1016/j.msec.2013.01.020
    » http://dx.doi.org/10.1016/j.msec.2013.01.020
  • 10
    De Souza ET, Nunes Tameirão MD, Roter JM, De Assis JT, De Almeida Neves A, De-Deus GA. Tridimensional quantitative porosity characterization of three set calcium silicate-based repair cements for endodontic use. Microsc Res Tech. 2013 Oct;76(10):1093-8. PMid:23913667. http://dx.doi.org/10.1002/jemt.22270
    » http://dx.doi.org/10.1002/jemt.22270
  • 11
    Carvalho-Júnior JR, Guimarães LFL, Correr-Sobrinho L, Pécora JD, Sousa-Neto MD. Evaluation of solubility, disintegration, and dimensional alterations of a glass ionomer root canal sealer. Braz Dent J. 2003;14(2):114-8. PMid:12964655. http://dx.doi.org/10.1590/S0103-64402003000200008
    » http://dx.doi.org/10.1590/S0103-64402003000200008
  • 12
    Chittoni SB, Martini T, Wagner MH, Da Rosa RA, Cavenago BC, Duarte MA, et al. Back-scattered electron imaging for leakage analysis of four retrofilling materials. Microsc Res Tech. 2012 Jun;75(6):796-800. PMid:22147679. http://dx.doi.org/10.1002/jemt.21128
    » http://dx.doi.org/10.1002/jemt.21128
  • 13
    Tanomaru-Filho M, Luis MR, Leonardo MR, Tanomaru JM, Silva LA. Evaluation of periapical repair following retrograde filling with different root-end filling materials in dog teeth with periapical lesions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2006 Jul;102(1):127-32. PMid:16831685. http://dx.doi.org/10.1016/j.tripleo.2005.09.008
    » http://dx.doi.org/10.1016/j.tripleo.2005.09.008
  • 14
    El-Ma’aita AM, Qualtrough AJ, Watts DC. A micro–computed tomography evaluation of Mineral Trioxide Aggregate root canal fillings. J Endod. 2012 May;38(5):670-2. PMid:22515899. http://dx.doi.org/10.1016/j.joen.2012.01.009
    » http://dx.doi.org/10.1016/j.joen.2012.01.009
  • 15
    Siqueira J Jr, Roccas I, Abad E, Castro A, Gahyva S, Favieri A. Ability of three root-end filling materials to prevent bacterial leakage. J Endod. 2001 Nov;27(11):673-5. PMid:11718135. http://dx.doi.org/10.1097/00004770-200111000-00005
    » http://dx.doi.org/10.1097/00004770-200111000-00005
  • 16
    Amoroso-Silva PA, Marciano MA, Guimarães BM, Duarte MA, Sanson AF, Moraes IG. Apical adaptation, sealing ability and push-out bond strength of five root-end filling materials. Braz Oral Res. 2014;28(1):1-6. PMid:25166765. http://dx.doi.org/10.1590/1807-3107BOR-2014.vol28.0043
    » http://dx.doi.org/10.1590/1807-3107BOR-2014.vol28.0043
  • 17
    Sousa-Neto MD, Guimarães LF, Gariba Silva R, Saquy PC, Pécora JD. The influence of different grades of rosins and hydrogenated resins on the powder-liquid ratio of Grossman cements. Braz Dent J. 1998;9(1):11-8. PMid:9835799.
  • 18
    Wuchenich G, Meadows D, Torabinejad M. A comparison between two root end preparation techniques in human cadavers. J Endod. 1994 Jun;20(6):279-82. PMid:7931024. http://dx.doi.org/10.1016/S0099-2399(06)80816-2
    » http://dx.doi.org/10.1016/S0099-2399(06)80816-2
  • 19
    Dias HB, Bernardi MIB, Ramos MADS, Trevisan TC, Bauab TM, Hernandes AC, et al. Zinc oxide 3D microstructures as an antimicrobial filler content for composite resins. Microsc Res Tech. 2017 Jun;80(6):634-43. PMid:28271628. http://dx.doi.org/10.1002/jemt.22840
    » http://dx.doi.org/10.1002/jemt.22840
  • 20
    Prado M, Simao RA, Gomes BP. A microleakage study of gutta-percha/AH Plus and Resilon/Real self-etch systems after different irrigation protocols. J Appl Oral Sci. 2014 Jun;22(3):174-9. PMid:25025557. http://dx.doi.org/10.1590/1678-775720130174
    » http://dx.doi.org/10.1590/1678-775720130174
  • 21
    Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. Radiographics. 2004 Nov;24(6):1679-91. PMid:15537976. http://dx.doi.org/10.1148/rg.246045065
    » http://dx.doi.org/10.1148/rg.246045065
  • 22
    Mendoza F, Verboven P, Mebatsion HK, Kerckhofs G, Wevers M, Nicolai B. Three-dimensional pore space quantification of apple tissue using X-ray computed microtomography. Planta. 2007 Aug;226(3):559-70. PMid:17361459. http://dx.doi.org/10.1007/s00425-007-0504-4
    » http://dx.doi.org/10.1007/s00425-007-0504-4
  • 23
    Camilleri J. Evaluation of selected properties of mineral trioxide aggregate sealer cement. J Endod. 2009 Oct;35(10):1412-7. PMid:19801242. http://dx.doi.org/10.1016/j.joen.2009.07.008
    » http://dx.doi.org/10.1016/j.joen.2009.07.008

Publication Dates

  • Publication in this collection
    07 Dec 2017
  • Date of issue
    Nov-Dec 2017

History

  • Received
    06 Aug 2017
  • Accepted
    21 Nov 2017
Universidade Estadual Paulista Júlio de Mesquita Filho Rua Humaitá, 1680 - Caixa Postal 331, 14801-903 Araraquara,São Paulo,SP, Tel.: (55 16) 3301-6376, Fax: (55 16) 3301-6433 - Araraquara - SP - Brazil
E-mail: adriana@foar.unesp.br