Acessibilidade / Reportar erro

Diagnosis of rubella infection by detecting specific immunoglobulin M antibodies in saliva samples: a clinic-based study in Niterói, RJ, Brazil

Diagnóstico laboratorial da rubéola através da detecção de imunoglobulina M específica em amostras de saliva

This study was designed to investigate whether saliva could be a feasible alternative to serum for the diagnosis of recent rubella infection in a clinic setting. Forty-five paired blood and saliva samples collected 1 to 29 days after onset of illness were tested for specific immunoglobulin (Ig) M by antibody-capture radioimmunoassay (MACRIA). Rubella IgM was detected in all serum samples and in 38 (84.4%) saliva specimens. Forty-six serum and saliva samples from other patients with rash diseases were tested by MACRIA for control purposes and two saliva specimens were reactive. The saliva test had specificity of 96%. These results indicate that salivary IgM detection may be a convenient non-invasive alternative to serum for investigation of recent rubella cases, especially for disease surveillance and control programmes.

Rubella; Saliva; Diagnosis; IgM; Antibody-capture radioimmunoassay


Sociedade Brasileira de Medicina Tropical - SBMT Caixa Postal 118, 38001-970 Uberaba MG Brazil, Tel.: +55 34 3318-5255 / +55 34 3318-5636/ +55 34 3318-5287, http://rsbmt.org.br/ - Uberaba - MG - Brazil