Acessibilidade / Reportar erro

Soil-cement formation factor: methodological approach and relationship with unconfined compression strength

Abstract

This study investigated the use of the Formation Factor of the material as an alternative way to estimate soil-cement strength involving no destructive tests. This factor is obtained from Archie's Law and consists of the ratio of pore water electrical conductivity to saturated porous material electrical conductivity, being related to porosity by constant terms. In this study, the electrical conductivity of the pore solution was obtained from a soil-cement leaching test after curing, and the conductivity of the monolithic soil-cement, by applying continuous voltage between 12-35 V onto electrodes of 1 mm thick copper plates. The influence of cement content and dry density on the electrical properties and water absorption was studied and discussed for curing times of 7 and 28 days. The samples molded with higher dry densities and cement contents presented higher Formation Factor for Soil Cement and higher unconfined compression strength. The Formation Factor and the unconfined compression strength are linearly related. Due to the methodology adopted, the Formation Factor was predominantly influenced by the conductivity of the pore solution and was related to the open porosity by means of a power function. Therefore, the Archie’s Law can be applied to soil-cement. In this case, the cementation coefficient varies until 28 days of curing, tending to stabilize around 8 from that age onwards. The volumetric coefficient can be adopted as a constant with a value of 1012.

Keywords:
Archie’s Law; Soil-cement; Absorption; Unconfined compression strength; Electrical conductivity

1. Introduction

Soil stabilization with the use of cement is used on a large scale in the production of earth bricks and in geotechnical works, such as pavement layers in roads and also in embankments (Bahar, et al., 2004Bahar, R., Benazoug, M., & Kenai, S. (2004). Performance of compacted cement-stabilized soil. Cement and Concrete Composites, 26, 811-820. http://dx.doi.org/10.1016/j.cemconcomp.2004.01.003.
http://dx.doi.org/10.1016/j.cemconcomp.2...
; Cardoso & Maranha das Neves, 2012Cardoso, R., & Maranha das Neves, E. (2012). Hydro-mechanical characterization of lime-treated and untreated marls used in a motorway embankment. Engineering Geology, 133-134, 76-84. http://dx.doi.org/10.1016/j.enggeo.2012.02.014.
http://dx.doi.org/10.1016/j.enggeo.2012....
). Performance standards prescribe minimum values for unconfined compression strength and water absorption. These parameters are largely affected by the cement dosage and compaction dry density, which may vary during construction, and for this it is important to develop non-destructive monitoring tools during construction for quality control.

In this context, there are studies involving the relationship between the physical properties of soil-cement and electrical conductivity or resistivity (e.g., Khalil & Santos, 2011Khalil, M.A., & Santos, F.A.M. (2011). Influence of degree of saturation in the electrical resistivity-hidraulic conductivity relationship. In O. Dikinya (Ed.), Developments in hydraulic conductivity research (Chap. 2, pp. 49-70). IntechOpen. Retrieved in July 8, 2021, from https://vdoc.pub/documents/developments-in-hydraulic-conductivity-research-3um1p1earg3g
https://vdoc.pub/documents/developments-...
; Kibria & Hossain, 2012Kibria, G., & Hossain, M.S. (2012). Investigation of geotechnical parameters affecting electrical resistivity of compacted clays. Journal of Geotechnical and Environmental Engineering, 138, 1520-1529. http://dx.doi.org/10.1061/(ASCE)GT.1943-5606.00007222.
http://dx.doi.org/10.1061/(ASCE)GT.1943-...
; Zhang et al., 2012Zhang, D., Chen, L., & Liu, S. (2012). Key parameters controlling electrical resistivity and strength of cement treated soils. Journal of Central South University, 19(10), 2991-2998. http://dx.doi.org/10.1007/s11771-012-1368-8.
http://dx.doi.org/10.1007/s11771-012-136...
; Hammad, 2013Hammad, A.H. (2013). Evaluation of soil-cement properties with electrical resistivity [Master, Dalhousie University]. Department of Civil Engineering, Dalhousie University. Retrieved in July 8, 2021, from http://hdl.handle.net/10222/21920
http://hdl.handle.net/10222/21920...
; Fallah-Safari et al., 2013Fallah-Safari, M., Hafizi, M. K., & Ghalandarzadeh, A. (2013). The relationship between clay geotechnical data and clay electrical resistivity. Bolletino di Geofisica ed Applicata, 54(1), 23-38. http://dx.doi.org/10.443/bgta0070.
http://dx.doi.org/10.443/bgta0070...
; Bai et al., 2013Bai, W., Kong, L., & Guo, A. (2013). Effects of physical properties on electrical conductivity of compacted lateritic soil. Journal of Rock Mechanics and Geotechnical Engineering, 5, 406-411. http://dx.doi.org/10.1016/j.jrmge.2013.07.003.
http://dx.doi.org/10.1016/j.jrmge.2013.0...
; Vincent et al., 2017Vincent, N.A., Shivashankar, R., Lokesh, K.N., & Jacob, J.M. (2017). Laboratory electrical resistivity studies on cement stabilized soil. International Scholarly Research Notices, 2017, 8970153. https://doi.org/10.1155/2017/8970153.
https://doi.org/ https://doi.org/10.1155...
). The methods used to obtain electrical measurements are easy and quick to apply, in addition to being non-destructive and non-invasive, which justifies their increasingly frequent use in research.

The electrical conductivity of the monolithic material, when associated with the conductivity of the pore solution, provides a parameter known as the Formation Factor (Archie, 1942Archie, G.E. (1942). The electrical resistivity log as an aid in determining some reservoir characteristics. Petroleum Transactions of AIME, 146(1), 54-62. https://doi.org/10.2118/942054-G.
https://doi.org/10.2118/942054-G...
). This factor, originally conceived for rocks, has been largely used in soil studies mainly for geophysical prospection (Rinaldi & Cuestas, 2002Rinaldi, V.A., & Cuestas, G.A. (2002). Ohmic conductivity of a compacted silty clay. Journal of Geotechnical and Geoenvironmental Engineering, 128(10), 824-835. http://dx.doi.org/10.1061/(ASCE)1090-0241(2002)128:10(824).
http://dx.doi.org/10.1061/(ASCE)1090-024...
; Lorenzo & Bergado, 2004Lorenzo, G.A., & Bergado, D.T. (2004). Fundamental parameters of cement-admixed clay: new approach. Journal of Geotechnical and Geoenvironmental Engineering, 130, 1042-1050. http://dx.doi.org/10.1061/(ASCE)1090-0241(2004)130:10(1042).
http://dx.doi.org/10.1061/(ASCE)1090-024...
; Shah & Singh, 2005Shah, P.H., & Singh, D.N. (2005). Generalized Archie’s law for estimation of soil electrical conductivity. Journal of ASTM International, 2(5), 1-19. http://dx.doi.org/10.1520/JAI13087.
http://dx.doi.org/10.1520/JAI13087...
; Song et al., 2008Song, Y.L., Yan, J.D., Han, L.H., & Gu, M.F. (2008). Experimental study on the electrical resistivity of soil–cement admixtures. Environmental Geology, 54, 1227-1233. http://dx.doi.org/10.1007/s00254-007-0905-5.
http://dx.doi.org/10.1007/s00254-007-090...
; Kahraman & Yeken, 2010Kahraman, S., & Yeken, T. (2010). Electrical resistivity measurement to predict uniaxial compression and tensile strength of igneous rocks. Bulletin of Materials Science, 33(6), 731-735. http://dx.doi.org/10.1007/s12034-011-0137-x.
http://dx.doi.org/10.1007/s12034-011-013...
). This factor (FF) is defined using Archie's equation (Equation 1), representing the relation between the electrical conductivity of the pore water and the saturated solid material (respectively Kw and K0), being function of porosity ϕ and calibration constants A (volumetric coefficient) and m (cementation coefficient).

F F = K w K 0 = A . ϕ m (1)

The electrical conductivity depends on soil structure and minerals, and chemical composition of the pore fluid. In fact, electrical current flows through the conductive liquid phase existing in soil voids and eventually through the surface of conductive minerals, being dependent on pore geometry, or tortuosity. This explains the fact that molding dry density and water content affect the electrical conductivity (Vaillant, 2013Vaillant, J.M.M. (2013). Avaliação dos parâmetros de lixiviação de metais pesados em matriz de cimento Portland por meio da condutividade elétrica [Doctoral Thesis, Federal University of Santa Catarina]. Federal University of Santa Catarina’s repository (in Portuguese). https://repositorio.ufsc.br/handle/123456789/107025
https://repositorio.ufsc.br/handle/12345...
; Vaillant & Cardoso, 2016Vaillant, J.M.M., & Cardoso, R. (2016). Comportamento da condutividade elétrica mediante variações nos parâmetros de compactação dos solos. In Anais do 15º Congresso Nacional de Geotecnia e 8º Congresso Luso-Brasileiro de Geotecnia: A Geotecnia e os desafios societais, Porto.). For the case of soil-cement mixtures, a combination of the porous net and the cement content of the mixture will contribute to introduce more tortuosity. This combination is also primarily responsible for the mechanical strength of the material. In addition, soluble elements from cement will affect the electrical conductivity of the pore solution. For this reason, it is important to evaluate the electrical conductivity of the pore fluid as it will change with cement dosage and curing time.

The relationship between the Formation Factor of the material and its mechanical strength has not been properly addressed in soil-cement research yet. This fact may be due to a difficulty in obtaining the measurement of the electrical conductivity of the pore solution or a scarcity of studies correlating the conductivity of the solid material with its compression strength. Only a few studies can be cited, especially Song et al. (2008)Song, Y.L., Yan, J.D., Han, L.H., & Gu, M.F. (2008). Experimental study on the electrical resistivity of soil–cement admixtures. Environmental Geology, 54, 1227-1233. http://dx.doi.org/10.1007/s00254-007-0905-5.
http://dx.doi.org/10.1007/s00254-007-090...
, Zhang et al. (2012)Zhang, D., Chen, L., & Liu, S. (2012). Key parameters controlling electrical resistivity and strength of cement treated soils. Journal of Central South University, 19(10), 2991-2998. http://dx.doi.org/10.1007/s11771-012-1368-8.
http://dx.doi.org/10.1007/s11771-012-136...
, Fallah-Safari et al. (2013)Fallah-Safari, M., Hafizi, M. K., & Ghalandarzadeh, A. (2013). The relationship between clay geotechnical data and clay electrical resistivity. Bolletino di Geofisica ed Applicata, 54(1), 23-38. http://dx.doi.org/10.443/bgta0070.
http://dx.doi.org/10.443/bgta0070...
and Vincent et al. (2017)Vincent, N.A., Shivashankar, R., Lokesh, K.N., & Jacob, J.M. (2017). Laboratory electrical resistivity studies on cement stabilized soil. International Scholarly Research Notices, 2017, 8970153. https://doi.org/10.1155/2017/8970153.
https://doi.org/ https://doi.org/10.1155...
.

Song et al. (2008)Song, Y.L., Yan, J.D., Han, L.H., & Gu, M.F. (2008). Experimental study on the electrical resistivity of soil–cement admixtures. Environmental Geology, 54, 1227-1233. http://dx.doi.org/10.1007/s00254-007-0905-5.
http://dx.doi.org/10.1007/s00254-007-090...
established relationships between the resistivity of a stabilized soil and its cement content, degree of saturation, moisture content, curing time and unconfined compression strength, as well as relationships with the soil SPT. They found a directly proportional linear function in the relation between resistivity (ρ) and resistance (qu), as shown in Equation 2.

q u = 286. ρ 334 (2)

A similar relationship between compression strength and resistivity can be found in the study by Kahraman & Yeken (2010)Kahraman, S., & Yeken, T. (2010). Electrical resistivity measurement to predict uniaxial compression and tensile strength of igneous rocks. Bulletin of Materials Science, 33(6), 731-735. http://dx.doi.org/10.1007/s12034-011-0137-x.
http://dx.doi.org/10.1007/s12034-011-013...
carried out on rocks. This study particularly highlights a model obtained from multiple regressions, relating the compression strength (σc, in MPa) with the electrical resistivity (ρ, in Ω.m), the apparent density (γ, in g/cm3), and porosity (n, in %), according to Equation 3.

σ c = 296 16 + 0 071 ρ + 6.33 n + 135 8 γ r = 0 97 (3)

Zhang et al. (2012)Zhang, D., Chen, L., & Liu, S. (2012). Key parameters controlling electrical resistivity and strength of cement treated soils. Journal of Central South University, 19(10), 2991-2998. http://dx.doi.org/10.1007/s11771-012-1368-8.
http://dx.doi.org/10.1007/s11771-012-136...
studied the influence of cement content, porosity and curing time on the electrical resistivity and compression strength of soil-cement, before and after wet curing. In that study, the authors established relations of resistivity (ρ) and unconfined compression strength (UCS) with a synthetic parameter, combining total porosity (nt), curing time (T) and cement content (aw). It was suggested that this relationship is similar to Archie's Law and, therefore, this law can be applied to soil-cement. The relationships mentioned above have a linear correlation coefficient of 0.98 and are represented in Equations 4 and 5, respectively for electrical resistivity (ρ) and compression strength (UCS).

ρ = 33.65 n t a w . T 0,71 (4)
U C S = 9.857. n t a w . T 1,11 (5)

Fallah-Safari et al. (2013)Fallah-Safari, M., Hafizi, M. K., & Ghalandarzadeh, A. (2013). The relationship between clay geotechnical data and clay electrical resistivity. Bolletino di Geofisica ed Applicata, 54(1), 23-38. http://dx.doi.org/10.443/bgta0070.
http://dx.doi.org/10.443/bgta0070...
used different samples of compacted clay (without reuse) at different apparent molding densities, to observe the relation between UCS and electrical resistivity. They observed a non-linear relation between the variables - an increase in electrical resistivity for increases in apparent density. The results, on average, were not consistent, since the highest correlation coefficient (R2) obtained was 0.829 for a bentonite sample, and for four other samples the obtained coefficient was lower than 0.7.

Vincent et al. (2017)Vincent, N.A., Shivashankar, R., Lokesh, K.N., & Jacob, J.M. (2017). Laboratory electrical resistivity studies on cement stabilized soil. International Scholarly Research Notices, 2017, 8970153. https://doi.org/10.1155/2017/8970153.
https://doi.org/ https://doi.org/10.1155...
studied four different samples of a soil stabilized with cement. They performed a multiple regression analysis between the unconfined compression strength and the electrical resistivity of the material before curing (fresh state), in the periods of 1 and 7 days of curing. The results are consistent with those obtained in other studies, observing increases in resistivity for proportional increases in cement content and curing time. This study presented only the equations for the initial stage of the mixture (before curing) and after a period of 1 day of curing, as it sought to obtain the UCS prediction at 7 days, that is, before hardening, to avoid losses. The type of curing adopted in this research was not mentioned.

In this context, this study proposes an easy-to-apply methodology to evaluate the compression strength of soil-cement composites based on relations with an Apparent Formation Factor of the soil-cement (henceforth called FFsc). Using the Archie's Law, this Formation Factor was determined both from measurements of electrical conductivity in the solid material after determined curing times (Kf) and from measurements of the leached solution, named Ksp (Equation 6). Electrical conductivity is the physical parameter that rules FFsc, which, in turn, is influenced by the material design parameters (dry volumetric weight or dry density at compaction, and cement content) and curing time.

F F s c = K s p K f = A . A b s m (6)

In this work the soil-cement porosity was replaced by the water absorption (Abs) (or open porosity), found using the saturation process described in the methodology section of ABNT NBR 8492 (ABNT, 2012bABNT NBR 8492. (2012b). Soil-cement brick — Dimensional analysis, compressive strength determination and water absorption — Test method. ABNT – Associação Brasileira de Normas Técnicas, Rio de Janeiro, RJ. (in Portuguese).). The water absorption is a parameter of quality control of soil-cement bricks at 7 days of age, whose value is limited to 20% (ABNT, 2012aABNT NBR 8491. (2012a). Soil-cement brick – Requirements. ABNT – Associação Brasileira de Normas Técnicas, Rio de Janeiro, RJ. (in Portuguese).).

The experimental conditions to measure the electrical conductivity of the solution, for which Archie's Law was postulated, were not obeyed in this study. This is because conductive clay minerals are dispersed in pore solution (Shale effect), and pore solution may be diluted. However, Archie's Law for this soil-cement is simple to use and allows obtaining a representative value of the “cementation” of the material. This law is being used as concept, because the formation factor depends on porosity, which comes from the connected porous network derived from dosing, molding, and curing conditions. Being associated with the presence of hydrated cement minerals, it will be latter possible to observe a relation between this factor and UCS.

Finally, this Apparent Formation Factor (FFsc) for soil-cement was related with UCS to define relationships which may be useful as a non-destructive method for quality control. The relations were established to consider dry density and cement dosage, in addition to the curing time.

2. Materials and methods

2.1 Materials and sample preparation

The soil samples used were fragments of marl from the Portuguese region of Abadia, which were passed through a #4 sieve. The fines content passed through sieve #200 with diameter <0.075 mm was of 17%. The minerals present were carbonates (16-23% calcite and dolomite), quartz (5-10%), other non-clayey minerals (8-17%), clays (1 5% chlorite, 17-30% kaolinite, 21-35% illite, 0-1% smectite and 30-60% mixed layer clays) and a very small percentage of organic matter (0-2%) (Maranha das Neves & Cardoso, 2006Maranha das Neves, E. & Cardoso, R. (2006). Research project for BRISA on the mechanical behaviour of embankments from A10 Motorway. Department of Civil Engineering, Report ICIST EP 23/06 and 23/08. Instituto Superior Tecnico. in Portuguese.). Liquid limit was 40% and plasticity index was 28% (classification CL) - values found using the fine fraction of the marl. The unit weight of solid particles was 27.5 kN/m3. The Portland cement type II-32 with unit weight of solid particles of 31.0 kN/m3 was used.

The specimens, molded in rectangular metallic forms with section of 4 × 4 cm2 and length of 16 cm (CEN, 2007CEN EN 1015-11. (2007). Methods of test for mortar for masonry. Part 11 - Determination of flexural and compression strength of hardened mortar. CEN – European Committee for Standardization, Brussels.), as shown in Figure 1a, were manually compacted in four layers, one-centimeter thick each. The compaction moisture adopted was approximately 2% above the optimum moisture obtained in Proctor Normal test. A pilot test was carried out to find the maximum possible dry density to be achieved in manual compaction. Thus, four levels of dry volumetric weights were defined up to the maximum limit achieved in the test: 14, 15, 16 and 17 kN/m3, respectively G1, G2, G3 and G4. Four cement dosages were mixed with each dry unit weight of marl: 5% (D1), 10% (D2), 15% (D3) and 20% (D4). The choice of these cement percentages was based on the most used content in the literature consulted. To individually identify each of the 16 combinations of density (G) and cement content (D), variable C was created. It represents the dosage of cement per volume or the cement content per m3 of mixture which values are shown in Table 1.

Figure 1
(a) specimen molding; (b) electric current reading procedures.
Table 1
Cement content (C) per m3 of soil-cement (kg/m3).

The samples were immediately extracted from the mold after compaction, weighted and their initial electrical conductivity was recorded. Then, curing was carried out in a humid chamber with a relative humidity greater than or equal to 95%. Curing times were established to be 7 days (ABNT, 2012aABNT NBR 8491. (2012a). Soil-cement brick – Requirements. ABNT – Associação Brasileira de Normas Técnicas, Rio de Janeiro, RJ. (in Portuguese).) and 28 days, being different specimens prepared for each period. The 28-day curing was included to observe the hydration process and its influence on electrical measurements. Considering the reference samples (without cement), a total of 108 specimens were manipulated for study.

After curing, the specimens were prepared for compression and leaching/absorption tests, which were performed after a new measurement of the electrical conductivity. This is the electrical conductivity of the saturated soil-cement (K0, or Kf if measured for different curing times). Each specimen of 4 cm × 4 cm × 16 cm was cut into three parts, being the cubic central part (4 × 4 cm2) reserved for the leaching and water absorption tests, and the two extremes (6 × 4 cm2) reserved for the simple compression tests (load applied along the larger dimension). The specimens reserved for the compression tests were wrapped in plastic wrap to prevent edge breaks.

2.2 Electrical conductivity of the treated compacted marls

The procedure adopted to measure the electrical conductivity of the treated compacted marls is presented in Figure 1b. A source of continuous tension between 12-35 V and one-millimeter-thick copper plate electrodes (10 × 10 cm2) was used to measure the electrical conductivity in the solid samples.

Electrical conductivity was computed using the well-known Ohm's law. The electric current was measured using the voltage source in the central part of the sample, applied perpendicularly to bedding layers formed in the compaction. The contact between the electrodes and the soil was ensured using a small weight, and a standard time for current stabilization of 15 seconds was adopted to consider capacitive effect of the material. Capacitive properties were not explored further. The soil-cement conductivity was taken in the saturated material with dry surface, i.e., superficially dried (ABNT, 2012bABNT NBR 8492. (2012b). Soil-cement brick — Dimensional analysis, compressive strength determination and water absorption — Test method. ABNT – Associação Brasileira de Normas Técnicas, Rio de Janeiro, RJ. (in Portuguese).).

2.3 Leaching, electrical conductivity and water adsorption joint tests

The central part of each sample was wrapped in filter paper to avoid possible loss of solid material (Figure 2a) after measuring the electrical conductivity. Then the sample was totally submerged in distilled water whose volume was defined to be 7.5 times the volume of the sample. It remained submerged (Figure 2b) until full saturation. Saturation was determined by controlling the sample weight along the leaching test.

Figure 2
(a) sample packaging; (b) submersion for leaching test; (c) measurement of the leachate electrical conductivity.

The experimental conditions to measure the electrical conductivity of the pore solution were not postulated as in Archie's Law. They were adapted in this study from the sample leaching. Two factors, then, probably affected the electrical conductivity measures obtained: the dispersion of clay minerals in pore solution, and the dilution of pore solution. However, the expectation is to validate Archie's Law for soil-cement under simplified experimental conditions and to obtain a representative value of the “cementation” of the material, that is, of the connected porous network derived from dosing, molding, and curing conditions

The electrical conductivity of the leached solution was measured using a CRISON conductivity meter (Figure 2c) (reading range of 0.2 μS/cm). The electrical conductivity of the pore solution of the samples (Ksp) was obtained from the relation between the accumulated conductivity and the leaching period, according to Vaillant (2013)Vaillant, J.M.M. (2013). Avaliação dos parâmetros de lixiviação de metais pesados em matriz de cimento Portland por meio da condutividade elétrica [Doctoral Thesis, Federal University of Santa Catarina]. Federal University of Santa Catarina’s repository (in Portuguese). https://repositorio.ufsc.br/handle/123456789/107025
https://repositorio.ufsc.br/handle/12345...
. The correlation curve presents a linear zone that is representative of the conductivity of the pore solution. Thus, the Ksp value was calculated from the slope of that line.

At the end of the leaching test the open porosity was determined after curing, at 7 and 28 days, by measuring the difference between total masses measured after saturation and after oven drying.

2.4 Unconfined compression tests

The unconfined compression tests were done following CEN EN 1015-11 (CEN, 2007CEN EN 1015-11. (2007). Methods of test for mortar for masonry. Part 11 - Determination of flexural and compression strength of hardened mortar. CEN – European Committee for Standardization, Brussels.). The load was applied adopting a constant rate of 0.5 mm/min for axial deformation. The precision of the equipment is 0.01 kN. The specimens tested were cut from the ends of the main sample (6 cm × 4 cm) and were subjected to saturation for four hours before the compression test. Figure 3 shows the steps followed for samples preparation.

Figure 3
Sample preparation for the UCS tests: (a) cutting; (b) saturation; (c) compression.

2.5 Electron scanning microscope images and mercury intrusion porosimetry tests

Complementary mercury intrusion porosimetry (MIP) tests were performed in 1 × 1 × 1 cm3 cubic portions extracted from some samples after 28 days curing to evaluate changes in pore sizes due to compaction and cement dosage. Electron scanning microscope images allowed to visualize the hydrated cement minerals formed for the different dosages adopted.

3. Results and discussion

3.1 Electron scanning microscope images

Figure 4 presents some electron scanning microscope images of the soil-cement structures modified by the compaction density (top photos) and stabilization with cement for 28 days of curing (bottom photos). The presence of the hydrated cement minerals is obvious in both samples, being more disperse and less thick in sample D2G4 than in sample D4G4. Their presence confirms pore clogging of the compacted material, interfering with electrical conductivity of the material because electrical current flows mainly through the liquid phase, i.e., by the pore fluid.

Figure 4
Microscopy of treated (bottom images) and untreated (top images) marls at different cement contents and molding density.

3.2 Influence of cement content on the conductivity of solid material (Kf)

Figure 5 presents the relation between cement content and saturated material electrical conductivity for 7 and 28 days of curing. In general, the electrical conductivity for a given curing period (Kf) tends to decrease with the increase of both cement content (C) and dry density (G) at compaction. This same behavior can be observed in other studies (e.g. Khalil & Santos, 2011Khalil, M.A., & Santos, F.A.M. (2011). Influence of degree of saturation in the electrical resistivity-hidraulic conductivity relationship. In O. Dikinya (Ed.), Developments in hydraulic conductivity research (Chap. 2, pp. 49-70). IntechOpen. Retrieved in July 8, 2021, from https://vdoc.pub/documents/developments-in-hydraulic-conductivity-research-3um1p1earg3g
https://vdoc.pub/documents/developments-...
; Kibria & Hossain, 2012Kibria, G., & Hossain, M.S. (2012). Investigation of geotechnical parameters affecting electrical resistivity of compacted clays. Journal of Geotechnical and Environmental Engineering, 138, 1520-1529. http://dx.doi.org/10.1061/(ASCE)GT.1943-5606.00007222.
http://dx.doi.org/10.1061/(ASCE)GT.1943-...
; Zhang et al., 2012Zhang, D., Chen, L., & Liu, S. (2012). Key parameters controlling electrical resistivity and strength of cement treated soils. Journal of Central South University, 19(10), 2991-2998. http://dx.doi.org/10.1007/s11771-012-1368-8.
http://dx.doi.org/10.1007/s11771-012-136...
; Hammad, 2013Hammad, A.H. (2013). Evaluation of soil-cement properties with electrical resistivity [Master, Dalhousie University]. Department of Civil Engineering, Dalhousie University. Retrieved in July 8, 2021, from http://hdl.handle.net/10222/21920
http://hdl.handle.net/10222/21920...
; Fallah-Safari et al., 2013Fallah-Safari, M., Hafizi, M. K., & Ghalandarzadeh, A. (2013). The relationship between clay geotechnical data and clay electrical resistivity. Bolletino di Geofisica ed Applicata, 54(1), 23-38. http://dx.doi.org/10.443/bgta0070.
http://dx.doi.org/10.443/bgta0070...
; Bai et al., 2013Bai, W., Kong, L., & Guo, A. (2013). Effects of physical properties on electrical conductivity of compacted lateritic soil. Journal of Rock Mechanics and Geotechnical Engineering, 5, 406-411. http://dx.doi.org/10.1016/j.jrmge.2013.07.003.
http://dx.doi.org/10.1016/j.jrmge.2013.0...
; Vincent et al., 2017Vincent, N.A., Shivashankar, R., Lokesh, K.N., & Jacob, J.M. (2017). Laboratory electrical resistivity studies on cement stabilized soil. International Scholarly Research Notices, 2017, 8970153. https://doi.org/10.1155/2017/8970153.
https://doi.org/ https://doi.org/10.1155...
).

Figure 5
Influence of cement content on the conductivity of the solid material for (a) 7 days and (b) 28 days of curing.

This behavior was expected, because the hydrated cement paste creates a new porous network in the material, with less quantity of pores and also disconnecting them (see the bottom images in Figure 4). This structural change has a direct impact on the material conductivity because the electrical current flows through the liquid phase and the path followed depends on the geometry of the connected pores. In addition, the amount of liquid present in the porous material is reduced by decreasing porosity and, for this reason, the conductivity decreases with the increase of dry density.

This reduction in conductivity is more marked for 28 days of curing, when the hydrated cement minerals are expected to be completely formed and therefore the quantity of ions dissolved in the pore water is reduced. Indeed, assuming the same amount of cement minerals for the same dosage (D), a consistent trend of behavior can be observed, indicating a power function whose exponent is close to 2.0 (Figure 6). This also seems to be the behavior trend observed in the work by Zhang et al. (2012)Zhang, D., Chen, L., & Liu, S. (2012). Key parameters controlling electrical resistivity and strength of cement treated soils. Journal of Central South University, 19(10), 2991-2998. http://dx.doi.org/10.1007/s11771-012-1368-8.
http://dx.doi.org/10.1007/s11771-012-136...
, for three samples studied at six different curing times.

Figure 6
Influence of cement content on the conductivity of the solid material.

There was a great dispersion for samples with seven days of curing, mainly for the highest cement dosages, which may be due to hydration reactions still in progress, with a greater amount of hydrated calcium compounds present in the system. This fact can also be observed and explained in other studies already mentioned (Liu et al., 2008Liu, S., Du, Y., Han, L., & Gu, M. (2008). Experimental study on the electrical resistivity of soil-cement admixtures. Environmental Geology, 54(6), 1227-1233. http://dx.doi.org/10.1007/s00254-007-0905-5.
http://dx.doi.org/10.1007/s00254-007-090...
; Chen et al., 2011Chen, L., Du, Y., Liu, S., & Jin, F. (2011). Evaluation of cement hidration properties of cement stabilized lead contaminated soils using electrical resistivity measurement. Journal of Hazardous, Toxic and Radioactive Waste, 15(4), 312-320. http://dx.doi.org/10.1061/(ASCE)HZ.1944-8376.0000073.
http://dx.doi.org/10.1061/(ASCE)HZ.1944-...
; Zhang et al., 2012Zhang, D., Chen, L., & Liu, S. (2012). Key parameters controlling electrical resistivity and strength of cement treated soils. Journal of Central South University, 19(10), 2991-2998. http://dx.doi.org/10.1007/s11771-012-1368-8.
http://dx.doi.org/10.1007/s11771-012-136...
; Vincent et al. (2017)Vincent, N.A., Shivashankar, R., Lokesh, K.N., & Jacob, J.M. (2017). Laboratory electrical resistivity studies on cement stabilized soil. International Scholarly Research Notices, 2017, 8970153. https://doi.org/10.1155/2017/8970153.
https://doi.org/ https://doi.org/10.1155...
. For this reason, the regressions for the seven-day-curing samples were not presented.

3.3 Influence of cement content on the conductivity of the pore solution (Ksp)

The presence of cement contributes to increase the conductivity of the pore solution (Ksp) due to dissolved ions. This conductivity is different from that of distilled water even for the untreated material due to the presence of dissolved clay minerals. The contribution of the cement is evident in the values of Ksp measured for the lowest curing age (7 days), when there is intense chemical activity (cement hydration reactions) impairing the diffuse ion transport. This can be seen in Figure 6, in which the relations were more dispersed at this early age than after 28 days of curing. It is assumed that, in the latter, the pore water system is chemically more stable and, therefore, there is a well-defined trend between the variables. For 28 days the values of Ksp are linearly related to the cement content (slope close to 0.4, in Figure 7b).

Figure 7
Influence of cement content on the conductivity of the pore solution for (a) 7 days and (b) 28 days of curing.

By keeping cement dosage (D) constant there is an increase in Ksp for increasing dry density (G). The increase in dry density imposes an increase in cement content to adjust to the required percentual dosage. For this reason, there will be a greater concentration of ions in the pore solution which, in turn, will have their volume reduced because of the reduction of large pores produced by the higher density. It seems that this may have accelerated the ion transport mechanism, increasing its concentration in the leached solution and, consequently, increasing its conductivity.

3.4 Influence of cement content on the soil-cement Formation Factor (FFsc)

The FFsc represents the structural arrangement of the material at its “formation”. For soil-cement, therefore, this factor will influence dosage parameters (cement content and compaction density), type and curing time. The mathematical relations between the FFsc and cement content (C), defined in kg/m3, are presented in Figure 8. The regressions were performed as a function of the samples dry density, which, in this case, also represents an increase in the cement content, as indicated by the deviations of the points to the right. The groups of samples for the different cement dosages (D) were highlighted with circles in the graphs.

Figure 8
Influence of cement content on the soil-cement Formation Factor for (a) 7 days and (b) 28 days of curing.

Similar trends relating the two variables can be seen, except for sample D4 for 7 days of curing. The differences found for this sample are possibly due to the presence of larger amounts of non-hydrated cement particles. In other words, the sample with 20% of cement (D4) seems to indicate a disproportionate hydration process, suggesting that the relationship between water and cement was not ideal, with not enough water to hydrate the existing amount of cement particles. This caused a kind of “delay effect” in the hydration process at this age, which interfered with the conductivity readings, reversing the trend presented for the other groups of samples, with lower cement contents. At 28 days of curing, however, there was greater stability in the formation of the porous network, and the slope of the curve tended to be constant for any dosage, as indicated by the equations in Figure 8b. This suggests that, for cement contents above 15%, it would be prudent to have a curing time longer than 7 days to ensure that the measurements of the treated materials will no longer be affected by this hydration delay.

No study was found in the literature on the application of the electrical conductivity of soil-cement for a content of 20%. There were also no studies of this material associated with Archie's Law, involving electrical conductivity reading of the pore solution. There are many studies on the application of Archie's Law to concretes and mortars, associated with porosity, permeability, setting time and ion diffusion, as reported in Vaillant (2013)Vaillant, J.M.M. (2013). Avaliação dos parâmetros de lixiviação de metais pesados em matriz de cimento Portland por meio da condutividade elétrica [Doctoral Thesis, Federal University of Santa Catarina]. Federal University of Santa Catarina’s repository (in Portuguese). https://repositorio.ufsc.br/handle/123456789/107025
https://repositorio.ufsc.br/handle/12345...
. These differences in porosity can be observed in the mercury intrusion porosimetry (MIP) tests, which indicated a minor difference in the porous network for samples D2 e D4. The curves presented in Figure 9, for samples D0G4, D2G4 and D4G4, indicate the expected overall reduction of the pore size with increasing density, being more visible for the smallest pores because the peak displaced from dimensions around 120 nm to 80 nm and to 50 nm, for increasing dosages D0, D2 and D4, respectively.

Figure 9
Mercury intrusion porosimetry for the samples with dry density G4 with different cement dosage.

Finally, as observed in Figure 8, samples with a higher cement content showed a higher FFsc, represented by the points shifting up and to the right. Those samples with a higher density had a higher FFsc, represented by the upward shift of samples G1-G4 (except for group D4, as already discussed). Curing time concurs to reduce electrical conductivity of the solid sample (Kf) and, therefore, the higher it is, the greater is the FFsc.

3.5 Influence of Kf and Ksp on the FFsc

Figure 10 presents the relations between the conductivities of the solid material and the pore solution, Kf and Ksp, and the FFsc value. The conductivity of the solid sample is lower for higher cement contents and higher for low contents (D4→D1). Thus, the FFsc increases when the conductivity of the solid decreases. On the other hand, the conductivity of the pore solution is lower for lower cement contents and higher for high cement contents (D1→D4). Therefore, the FFsc increases when the conductivity of the pore solution is increased.

Figure 10
Influence of conductivities (Ksp and Kf ) on the value of the formation factor (FFsc) for (a) 7 days and (b) 28 days of curing.

However, FFsc is more sensitive to Ksp than to Kf: when Kf increases by a ratio of two (2), FFsc decreases by a ratio close to three (3) times or 37%; when Ksp increases in the same proportion, the FFsc increases in the rate of ten (10) times on average, or 1000%. This fact is certainly related to the lower resistance of the liquid medium to the passage of electric current, and also to the method used to obtain Ksp from the leaching test, as discussed above. The FFsc will be unitary when the conductivities of the solution and the solid are equal. For the studied soil, this occurred for the value of 45 μS/cm, as can be seen in Figure 10.

3.6 Influence of open porosity on the FFsc

FFsc is inversely proportional to the open porosity (Figure 11), represented here by the absorption of water, in compliance with Archie's Law. The only exception was observed in sample D4 at 7 days.

Figure 11
Influence of open porosity (Abs) on the soil-cement FFsc for (a) 7 days and (b) 28 days of curing.

The results show small variations in open porosity for increases in cement content. These variations are more consistent when the mold density is increased, except for the D4 sample. Considering only samples with 28 days of curing, the minimum open porosity achieved for the soil-cement in this study was close to 20% (D2G4), and the maximum close to 32% (D1G1). The FFsc is close to 5 for samples D1G4, 17 for D2G4 e reaches 150 in samples D4G4, indicating the influence of cement content on this factor.

It seems that the cementation coefficients (m) tend to stabilize for cement contents above 10%. This occurred with the samples with 7 and 28 days, demonstrating an independence of curing time from that dose onwards. The cement content influences the FFsc due to the hydration products, and its value varies if there are hydration reactions taking place, as indicated by the results (Figure 8). However, the increase in cement content does not represent a reduction in open porosity, in general. This will also depend on the mold density, as exemplified in Table 2.

Table 2
Variation of open porosity (Abs) with cement content for the samples G3 and G4.

The value of the cementation coefficient was close to 8 for the samples D3 and D4, being close to 9 and 6 for samples D2 and D1, respectively. These values for m constant are similar to those found for soil-cement mixtures (Backe et al., 2001Backe, K.R., Lile, O.B., & Lyomov, S.K. (2001). Characterizing curing cement slurries by electrical conductivity. SPE Drilling & Completion, 16(4), 201-207. http://dx.doi.org/10.2118/74694-PA.
http://dx.doi.org/10.2118/74694-PA...
) and hardened mortars (Garboczi, 1990Garboczi, E.J. (1990). Permeability, diffusivity, microstructural parameters: a critical review. Cement and Concrete Research, 20(4), 591-601. http://dx.doi.org/10.1016/0008-8846(90)90101-3.
http://dx.doi.org/10.1016/0008-8846(90)9...
; Christensen et al., 1994Christensen, B.J., Coverdale, T., Olson, R.A., Ford, S.J., Garboczi, E.J., Jennings, H.M., & Mason, T.O. (1994). Impedance spectroscopy of hydrating cement-based materials: measurement, interpretation, and application. Journal of the American Ceramic Society, 77(11), 2789. http://dx.doi.org/10.1111/j.1151-2916.1994.tb04507.x.
http://dx.doi.org/10.1111/j.1151-2916.19...
; Backe et al., 2001Backe, K.R., Lile, O.B., & Lyomov, S.K. (2001). Characterizing curing cement slurries by electrical conductivity. SPE Drilling & Completion, 16(4), 201-207. http://dx.doi.org/10.2118/74694-PA.
http://dx.doi.org/10.2118/74694-PA...
) and sand-cement mixtures (Cardoso, 2016Cardoso, R. (2016). Porosity and tortuosity influence on geophysical properties of an artificially cemented sand. Engineering Geology, 211(23), 198-207. http://dx.doi.org/10.1016/j.enggeo.2016.07.009.
http://dx.doi.org/10.1016/j.enggeo.2016....
), higher than the values found for soils and rocks (between 1 and 3, if Archie´s law is used). An acceptable explanation given by Christensen et al. (1994)Christensen, B.J., Coverdale, T., Olson, R.A., Ford, S.J., Garboczi, E.J., Jennings, H.M., & Mason, T.O. (1994). Impedance spectroscopy of hydrating cement-based materials: measurement, interpretation, and application. Journal of the American Ceramic Society, 77(11), 2789. http://dx.doi.org/10.1111/j.1151-2916.1994.tb04507.x.
http://dx.doi.org/10.1111/j.1151-2916.19...
for such high value is that the pore structure of cement slurries is much more tortuous and less porous than that of rocks. Similar explanation was given by Bryant & Pallatt (1996)Bryant, S., & Pallatt, N. (1996). Predicting formation factor and resistivity index in simple sandstones. Journal of Petroleum Science Engineering, 15(2-4), 169-179. in the interpretation of the results found for very low-porosity rocks.

The other constant in Archie's equation (A) represents a volumetric factor and its value has an extensive range of variations attributed to a series of intervening factors (Worthington, 1993Worthington, P.F. (1993). The uses and abuses of Archie equations, 1: the formation factor-porosity relationship. Journal of Applied Geophysics, 30(3), 215-228. http://dx.doi.org/10.1016/0926-9851(93)90028-W.
http://dx.doi.org/10.1016/0926-9851(93)9...
). For the soil-cement samples in this study, this coefficient did not show significant variations for samples above 10%. The values were very high, in the order of magnitude of 1012, indicating that the FFsc tends to infinity when porosity tends to zero. On the other hand, experimental data reveal the tendency of the curve to tangent the porosity axis. It means that when it reaches its maximum value, the FFsc value reaches zero, theoretically.

4. FFsc and UCS

4.1 Influence of the soil-cement formation factor on UCS

The relation between the UCS of the soil-cement mixtures and the Formation Factor is presented in Figure 12. The samples dosed with 20% of cement (D4) were excluded from the analysis, due to the deviations presented by the FFsc in the samples with 7 days of curing. Although this dispersion was minimized in the 28-day samples, as previously mentioned. UCS increases linearly with FFsc, which in turn increases with cement content (D1→D4) and molding density (G1→G4), as shown in Figure 12.

Figure 12
Relation between FFsc and UCS for: (a) 7 days for each cement content; (b) 7 days for any content; (c) 28 days for each cement content; (d) 28 days for any content.

The logarithmic scale was adopted to favor the visualization of the trend curves, with indicate good linear relations between the variables. A good fitting is also found if all samples are considered in a unique relationship (Figures 12b and 12d), with angular and linear coefficients with values of 0.08 and 0.11 for curing of 7 days, and 0.02 and 0.53 for curing of 28 days.

Considering that the FFsc is lower for the largest porosities (Figure 11), then the UCS will be higher for higher values of FFsc, as expected due to this mechanical property of the material. Note that there is also a progression of strength in relation to the cement dosage, which can be verified on the right part of the plot (Figures 12a and 12c).

The FFsc is a parameter obtained after curing the soil-cement in saturation condition and should not vary for periods over 28 days. So, it can be an alternative to control this material strength after its production, in addition to the usual way that relates strength to the design parameters (GC). Nevertheless, it is best to consider each dosage to minimize error, as discussed next.

Considering the soil characteristics and the manual molding conditions adopted in this study, the unconfined compression strength reached minimum values ​​(2 MPa) only at the curing time of 28 days, for samples molded close to dry density of 1.7 (G4) and cement content equal to or above 15% (D3 and D4).

The equation in Figure 12b indicates that to obtain a minimum value of UCS = 2 MPa at 7 days, the FFsc should be close to 24 or greater. Thus, by the graph of Figure 10, it is possible to know which value of electrical conductivity of the solid and of the solution must be obtained in the measurements. Applying the equation, the values found are, respectively, 5 μS/cm and 113 μS/cm, approximately.

4.2 Influence of design parameters on soil-cement UCS

The values of soil-cement UCS can be mathematically related with the cement contents, as it is usually done for mortars and concrete. This is presented in Figure 13. In this figure it is also shown that there is a direct relationship between the soil-cement UCS and its molding density.

Figure 13
Influence of cement content on soil-cement UCS for: (a) 7 days and (b) 28 days. Influence of the dry density on soil-cement UCS for: (c) 7 days and (d) 28 days.

The slope of the regression line corresponds to an increase in the UCS when dry density and cement content increase. Regarding the constant cement content (C), the UCS grows vertically with the dry mold density. The small slope of the correlation line is due to the cement content that was increased with the density. On the other hand, for constant molding density (G), the UCS values also increase vertically with dosage. Relationships such as these are useful to quantify UCS using this non-destructive technique.

From the plots in Figure 13, the UCS is obtained for any combination of cement consumption (C) and mold density (G) for the cement-stabilized soil. Table 3 presents the calculations obtained for a UCS = 2 MPa, including the control parameters, confirming that high dry densities are required in molding for low cement contents. It seems relevant to remember that more unfavorable conditions were adopted in this study, such as manual compaction, immediate demolding and curing in a wet chamber.

Table 3
Results of dosing and control parameters for UCS = 2 MPa.

The calculations show the possible combinations in dosing parameters to achieve the desired strength, both at 7 and 28 days. In some cases, it is still necessary to meet a water absorption requirement at 7 days of curing, which is 20% on average. Thus, the most economical dosage in this context would be for a cement consumption of 337.3 kg/m3 and molding density of 2059.2 kg/m3. However, this density would not be obtained manually.

The calculations also indicate the variation of FFsc as a function of curing time. This factor was calculated based on the good general relations shown in Figure 12. Therefore, it is constant for all combinations. The volumetric constant (A) of Archie's Law was also considered constant for all sample combinations because it is “volumetric factor” with a value of a high order of magnitude. Small variations in the “cementation coefficient” (m) can be observed for each variation in dosage. Also, this coefficient tends to stabilize at the end of the “formation” of the definitive structure of the material at 28 days of curing.

The Kf values were obtained from the equations in Figure 10 and they presented a constant value along curing time. The Ksp value was calculated from this conductivity and the FFsc. Thus, minimum values were obtained for this variable and equations with poor correlation coefficients were avoided, as seen in Figure 10a.

5. Conclusions

A methodology is proposed to evaluate the UCS of compacted soil-cement mixtures by using a non-destructive technique, in which the electrical conductivity of the material and that of the fluid from a leaching test are measured to compute the parameter FFsc. This Formation Factor of the soil-cement varies for each combination of dosage/dry density. These parameters contribute to the variations in the electrical conductivity of the material (Kf) and of the pore solution (Ksp). This last measure increases with increasing cement content, and the second decreases. However, FFsc is more sensitive to Ksp than to Kf, in a proportion 5 times greater. Curing time concurs to reduce electrical conductivity of the solid sample (Kf) and, therefore, the higher it is, the greater is the FFsc. The cement content influences the FFsc from the porous network formed with the hydration products, and its value varies as long as there are hydration reactions taking place. However, the increase in cement content does not represent a reduction in open porosity in general. This will also depend on the mold density.

The cementation coefficient is not constant for the material up to 7 days of curing, but it seems to stabilize at 28 days. At this age, the value of the cementation coefficient was close to 8 for the samples D3 and D4, and close to 9 and 6 for the samples D2 and D1, respectively. The same occurred to the volumetric factor (A), whose values were very high, in the order of magnitude of 1012 on average. Therefore, the higher the FFsc of the soil-cement, the higher its UCS. It was seen that UCS increases with both mold density and cement content.

Therefore, it is possible to design the material quality control parameters of the soil-cement and, consequently, the dosage parameters to obtain a specific UCS using the methodological conditions proposed by this study.

List of symbols

m cementation coefficient of the Archie’s Law

A volumetric coefficient of the Archie’s Law

Abs water absorption or open porosity

C cement content in kg/m3

CL clay low

D cement content in percentage

FF Archie’s Formation Factor for conductivity

FFsc Apparent Factor Formation for soil-cement

G molding dry volumetric weight (kN/m3)

K0 electrical conductivity of saturated material

Kf electrical conductivity of soil-cement saturated after curing

Ksp electrical conductivity of soil-cement pore solution

Kw electrical conductivity of material pore solution

UCS unconfined compression strength of the soil

ϕ porosity of the material

Acknowledgements

We are thankful to Instituto Superior Técnico of Lisbon University for having supported the conduct of the research and the Brazilian sponsoring agency CAPES (Coordenação de Aperfeiçoamento de Pessoal de Nível Superior) for the funding.

  • Discussion open until February, 28, 2023.

References

  • ABNT NBR 8491. (2012a). Soil-cement brick – Requirements ABNT – Associação Brasileira de Normas Técnicas, Rio de Janeiro, RJ. (in Portuguese).
  • ABNT NBR 8492. (2012b). Soil-cement brick — Dimensional analysis, compressive strength determination and water absorption — Test method ABNT – Associação Brasileira de Normas Técnicas, Rio de Janeiro, RJ. (in Portuguese).
  • Archie, G.E. (1942). The electrical resistivity log as an aid in determining some reservoir characteristics. Petroleum Transactions of AIME, 146(1), 54-62. https://doi.org/10.2118/942054-G
    » https://doi.org/10.2118/942054-G
  • Backe, K.R., Lile, O.B., & Lyomov, S.K. (2001). Characterizing curing cement slurries by electrical conductivity. SPE Drilling & Completion, 16(4), 201-207. http://dx.doi.org/10.2118/74694-PA
    » http://dx.doi.org/10.2118/74694-PA
  • Bahar, R., Benazoug, M., & Kenai, S. (2004). Performance of compacted cement-stabilized soil. Cement and Concrete Composites, 26, 811-820. http://dx.doi.org/10.1016/j.cemconcomp.2004.01.003
    » http://dx.doi.org/10.1016/j.cemconcomp.2004.01.003
  • Bai, W., Kong, L., & Guo, A. (2013). Effects of physical properties on electrical conductivity of compacted lateritic soil. Journal of Rock Mechanics and Geotechnical Engineering, 5, 406-411. http://dx.doi.org/10.1016/j.jrmge.2013.07.003
    » http://dx.doi.org/10.1016/j.jrmge.2013.07.003
  • Bryant, S., & Pallatt, N. (1996). Predicting formation factor and resistivity index in simple sandstones. Journal of Petroleum Science Engineering, 15(2-4), 169-179.
  • Cardoso, R. (2016). Porosity and tortuosity influence on geophysical properties of an artificially cemented sand. Engineering Geology, 211(23), 198-207. http://dx.doi.org/10.1016/j.enggeo.2016.07.009
    » http://dx.doi.org/10.1016/j.enggeo.2016.07.009
  • Cardoso, R., & Maranha das Neves, E. (2012). Hydro-mechanical characterization of lime-treated and untreated marls used in a motorway embankment. Engineering Geology, 133-134, 76-84. http://dx.doi.org/10.1016/j.enggeo.2012.02.014
    » http://dx.doi.org/10.1016/j.enggeo.2012.02.014
  • CEN EN 1015-11. (2007). Methods of test for mortar for masonry. Part 11 - Determination of flexural and compression strength of hardened mortar CEN – European Committee for Standardization, Brussels.
  • Chen, L., Du, Y., Liu, S., & Jin, F. (2011). Evaluation of cement hidration properties of cement stabilized lead contaminated soils using electrical resistivity measurement. Journal of Hazardous, Toxic and Radioactive Waste, 15(4), 312-320. http://dx.doi.org/10.1061/(ASCE)HZ.1944-8376.0000073
    » http://dx.doi.org/10.1061/(ASCE)HZ.1944-8376.0000073
  • Christensen, B.J., Coverdale, T., Olson, R.A., Ford, S.J., Garboczi, E.J., Jennings, H.M., & Mason, T.O. (1994). Impedance spectroscopy of hydrating cement-based materials: measurement, interpretation, and application. Journal of the American Ceramic Society, 77(11), 2789. http://dx.doi.org/10.1111/j.1151-2916.1994.tb04507.x
    » http://dx.doi.org/10.1111/j.1151-2916.1994.tb04507.x
  • Fallah-Safari, M., Hafizi, M. K., & Ghalandarzadeh, A. (2013). The relationship between clay geotechnical data and clay electrical resistivity. Bolletino di Geofisica ed Applicata, 54(1), 23-38. http://dx.doi.org/10.443/bgta0070
    » http://dx.doi.org/10.443/bgta0070
  • Garboczi, E.J. (1990). Permeability, diffusivity, microstructural parameters: a critical review. Cement and Concrete Research, 20(4), 591-601. http://dx.doi.org/10.1016/0008-8846(90)90101-3
    » http://dx.doi.org/10.1016/0008-8846(90)90101-3
  • Hammad, A.H. (2013). Evaluation of soil-cement properties with electrical resistivity [Master, Dalhousie University]. Department of Civil Engineering, Dalhousie University. Retrieved in July 8, 2021, from http://hdl.handle.net/10222/21920
    » http://hdl.handle.net/10222/21920
  • Kahraman, S., & Yeken, T. (2010). Electrical resistivity measurement to predict uniaxial compression and tensile strength of igneous rocks. Bulletin of Materials Science, 33(6), 731-735. http://dx.doi.org/10.1007/s12034-011-0137-x
    » http://dx.doi.org/10.1007/s12034-011-0137-x
  • Khalil, M.A., & Santos, F.A.M. (2011). Influence of degree of saturation in the electrical resistivity-hidraulic conductivity relationship. In O. Dikinya (Ed.), Developments in hydraulic conductivity research (Chap. 2, pp. 49-70). IntechOpen. Retrieved in July 8, 2021, from https://vdoc.pub/documents/developments-in-hydraulic-conductivity-research-3um1p1earg3g
    » https://vdoc.pub/documents/developments-in-hydraulic-conductivity-research-3um1p1earg3g
  • Kibria, G., & Hossain, M.S. (2012). Investigation of geotechnical parameters affecting electrical resistivity of compacted clays. Journal of Geotechnical and Environmental Engineering, 138, 1520-1529. http://dx.doi.org/10.1061/(ASCE)GT.1943-5606.00007222
    » http://dx.doi.org/10.1061/(ASCE)GT.1943-5606.00007222
  • Liu, S., Du, Y., Han, L., & Gu, M. (2008). Experimental study on the electrical resistivity of soil-cement admixtures. Environmental Geology, 54(6), 1227-1233. http://dx.doi.org/10.1007/s00254-007-0905-5
    » http://dx.doi.org/10.1007/s00254-007-0905-5
  • Lorenzo, G.A., & Bergado, D.T. (2004). Fundamental parameters of cement-admixed clay: new approach. Journal of Geotechnical and Geoenvironmental Engineering, 130, 1042-1050. http://dx.doi.org/10.1061/(ASCE)1090-0241(2004)130:10(1042)
    » http://dx.doi.org/10.1061/(ASCE)1090-0241(2004)130:10(1042)
  • Maranha das Neves, E. & Cardoso, R. (2006). Research project for BRISA on the mechanical behaviour of embankments from A10 Motorway. Department of Civil Engineering, Report ICIST EP 23/06 and 23/08 Instituto Superior Tecnico. in Portuguese.
  • Rinaldi, V.A., & Cuestas, G.A. (2002). Ohmic conductivity of a compacted silty clay. Journal of Geotechnical and Geoenvironmental Engineering, 128(10), 824-835. http://dx.doi.org/10.1061/(ASCE)1090-0241(2002)128:10(824)
    » http://dx.doi.org/10.1061/(ASCE)1090-0241(2002)128:10(824)
  • Shah, P.H., & Singh, D.N. (2005). Generalized Archie’s law for estimation of soil electrical conductivity. Journal of ASTM International, 2(5), 1-19. http://dx.doi.org/10.1520/JAI13087
    » http://dx.doi.org/10.1520/JAI13087
  • Song, Y.L., Yan, J.D., Han, L.H., & Gu, M.F. (2008). Experimental study on the electrical resistivity of soil–cement admixtures. Environmental Geology, 54, 1227-1233. http://dx.doi.org/10.1007/s00254-007-0905-5
    » http://dx.doi.org/10.1007/s00254-007-0905-5
  • Vaillant, J.M.M. (2013). Avaliação dos parâmetros de lixiviação de metais pesados em matriz de cimento Portland por meio da condutividade elétrica [Doctoral Thesis, Federal University of Santa Catarina]. Federal University of Santa Catarina’s repository (in Portuguese). https://repositorio.ufsc.br/handle/123456789/107025
    » https://repositorio.ufsc.br/handle/123456789/107025
  • Vaillant, J.M.M., & Cardoso, R. (2016). Comportamento da condutividade elétrica mediante variações nos parâmetros de compactação dos solos. In Anais do 15º Congresso Nacional de Geotecnia e 8º Congresso Luso-Brasileiro de Geotecnia: A Geotecnia e os desafios societais, Porto.
  • Vincent, N.A., Shivashankar, R., Lokesh, K.N., & Jacob, J.M. (2017). Laboratory electrical resistivity studies on cement stabilized soil. International Scholarly Research Notices, 2017, 8970153. https://doi.org/10.1155/2017/8970153.
    » https://doi.org/ https://doi.org/10.1155/2017/8970153
  • Worthington, P.F. (1993). The uses and abuses of Archie equations, 1: the formation factor-porosity relationship. Journal of Applied Geophysics, 30(3), 215-228. http://dx.doi.org/10.1016/0926-9851(93)90028-W
    » http://dx.doi.org/10.1016/0926-9851(93)90028-W
  • Zhang, D., Chen, L., & Liu, S. (2012). Key parameters controlling electrical resistivity and strength of cement treated soils. Journal of Central South University, 19(10), 2991-2998. http://dx.doi.org/10.1007/s11771-012-1368-8
    » http://dx.doi.org/10.1007/s11771-012-1368-8

Publication Dates

  • Publication in this collection
    10 Oct 2022
  • Date of issue
    2022

History

  • Received
    08 July 2021
  • Accepted
    21 Aug 2022
Associação Brasileira de Mecânica dos Solos Av. Queiroz Filho, 1700 - Torre A, Sala 106, Cep: 05319-000, São Paulo - SP - Brasil, Tel: (11) 3833-0023 - São Paulo - SP - Brazil
E-mail: secretariat@soilsandrocks.com