Acessibilidade / Reportar erro

A Choline Chloride-Ethylene Glycol Deep Eutectic Solvent Based on Magnetic Polydopamine with Preconcentration and Determination for Sulfonylurea Herbicides in Water Samples

Abstract

In this study, a novel deep eutectic solvent (DES) containing choline chloride and ethylene glycol was synthesized, and the magnetic polydopamine (PDA) was modified with this deep eutectic solvent to form Fe3O4@PDA-DES. Fourier transformed infrared spectroscopy, scanning electron microscopy, and vibrating sample magnetometer were used to characterize the proposed adsorbent. Then, this magnetic material was used as an adsorbent in the magnetic solid phase extraction process for the extraction of four sulfonylurea herbicides in water samples. The main parameters relevant to this method were investigated. Under the optimum conditions, the linearity was obtained by five points in the concentration range of 1.0-200 µg L-1 and with the correlation coefficients (r) ≥ 0.9927. The enrichment factors were in a range of 495 to 615 and the relative standard deviations were less than 4.3%. The limits of detection varied from 0.0092 to 0.0113 µg L-1. The recoveries of environmental water samples were 61.9 to 100.1%, and the recoveries of drinking water samples were 71.1-101.9%. All results highlighted the excellent potential of magnetic solid phase extraction coupled with ultra-high performance liquid chromatography strategy in selective separation and extraction of sulfonylurea herbicides in water samples.

Keywords:
sulfonylurea herbicides; deep eutectic solvent; choline chloride; magnetic polydopamine; water samples


Introduction

Sulfonylurea herbicides (SUHs) are one type of herbicides with high herbicidal activity and low toxicity. They are increasingly used for the control of broad-leaved weeds and some other weeds. However, the widespread application of SUHs results in their occurrence in adjacent environmental systems. Therefore, the analysis of SUHs residue is of great importance to environmental protection and human health. Sample pretreatment technique is a significantly vital step in chemical analysis. Presently reported pretreatment techniques for the detection of sulfonylurea herbicides mainly include solid phase extraction (SPE),11 Fang, G.; Chen, J.; Wang, J.; J. Chromatogr. A 2010, 1217, 1567.

2 Yan, C.; Zhang, B.; Liu, W.; J. Chromatogr. B: Anal. Technol. Biomed. Life Sci. 2011, 879, 3484.
-33 Fenoll, J.; Hellín, P.; Sabater, P.; Talanta 2012, 101, 273. dispersed solid phase extraction (DSPE),44 Wu, Q.; Wang, C.; Liu, Z.; J. Chromatogr. A 2009, 1216, 5504. and molecularly imprinted solid phase extraction (MISPE).55 Tang, K.; Chen, S.; Gu, X.; Anal. Chim. Acta 2008, 614, 112. SPE is the most frequently used method in all these sample pretreatment technologies. Miniaturization of separation technology, especially in liquid-phase and solid-phase extraction methods, is a trend of analytical chemistry, which could improve extraction efficiency, reduce operating costs, and have no environmental pollution. Recently, magnetic solid phase extraction (MSPE) has received increasing attention as a relative neotype of SPE technique based on the use of magnetic or magnetizable adsorbents.66 Safarikova, M.; Safarik, I.; J. Magn. Magn. Mater. 1999, 194, 108. It possesses advantages of high extraction efficient, high enrichment factor, easy and convenient operational process, and can be applied directly in rough samples.77 Wang, D. D.; Zhao, Y.; Ou-yang, M. N.; Guo, H. M.; Yang, Z. H.; J. Chromatogr. A 2019, 1601, 53. Meanwhile, the magnetic solid phase extraction technique simplifies the sample processing process and saves time.88 He, Z.; Liu, D.; Li, R.; Anal. Chim. Acta 2012, 747, 29.,99 Ma, J.; Jiang, L.; Wu, G.; J. Chromatogr. A 2016, 1466, 12.

Polydopamine (PDA) is formed by mild oxidative polymerization of dopamine under alkaline condition. PDA is rich in amino and phenolic hydroxyl groups which can easily adhere to different materials.1010 Zhang, L.; Wu, J.; Wang, Y.; J. Am. Chem. Soc. 2012, 134, 9879.,1111 Qin, Y.; Wang, M.; Sun, Z.; J. Mater. Chem. B 2013, 1, 6085. PDA has been widely used in surface modification,1212 Qian, Y.; Feng, Z.; Liu, W.; Chem. Soc. Rev. 2011, 40, 4244. controlled release,1313 Zheng, Q.; Lin, T.; Wu, H.; Int. J. Pharm. 2014, 463, 22. immunoassays1414 Lai, G.; Zhang, H.; Yong, J.; Biosens. Bioelectron. 2013, 47, 178. and MSPE process.1515 Xia, Z.; Lin, Z.; Xiao, Y.; Biosens. Bioelectron. 2013, 47, 120.

16 Liu, R.; Sha, M.; Jiang, S.; Talanta 2014, 120, 76.
-1717 Wang, X.; Song, G.; Deng, C.; Talanta 2015, 132, 753.

Deep eutectic solvent (DES), as a novel green solvent with similar physical properties and phase behavior to ionic liquids,1818 Erbas, Z.; Soylak, M.; Yilmaz, E.; Dogan, M.; Microchem. J. 2019, 145, 745. was firstly introduced by Abbot et al.1919 Abbott, A. P.; Capper, G.; Davies, D. L.; Rasheed, R. K.; Tambyrajah, V.; Chem. Commun. 2003, 9, 70. in 2003. DES has attracted extensive attention because of the advantages such as low vapor pressure, wide liquid phase range, easy preparation, low cost, and non-toxicity.2020 Smith, E. L.; Abbott, A. P.; Ryder, K. S.; Chem. Rev. 2014, 114, 11060. These solvents are usually synthesized by mixing quaternary ammonium salts as hydrogen bond acceptors (HBA) and naturally derived non-charged hydrogen bond donors (HBD).2121 Abbott, A. P.; Cullis, P. M.; Gibson, M. J.; Green Chem. 2007, 9, 868. In particular, as a biodegradable and non-toxic quaternary ammonium salt, choline chloride (ChCl) has become a commonly used hydrogen-bonded donor in DES.2222 Hammond, O. S.; Bowron, D. T.; Edler, K. J.; Green Chem. 2016, 18, 2736. Because of the excellent characteristics, DES prepared by ChCl has been used in areas such as organic synthesis,2323 Gore, S.; Baskaran, S.; Koenig, B.; Green Chem. 2011, 13, 1009. electro-deposition,2424 Sebastián, P.; Torralba, E.; Vallés, E.; Electrochim. Acta 2015, 164, 187. extraction of heavy metal ions,2525 Gulsah, S. K.; Erkan, Y.; Mustafa, S.; J. Iran. Chem. Soc. 2018, 15, 2307. nano-materials2626 Karimi, M.; Hesaraki, S.; Alizadeh, M.; Ceram. Int. 2016, 42, 2780. preparation and separation process.2727 Abdul, H. N.; Ng, M. H.; Choo, Y. M.; J. Am. Oil Chem. Soc. 2015, 92, 1709.

In the current study, we synthesized a novel DES by mixing choline chloride (HBA) and ethylene glycol (HBD). The obtained DES has both hydrophilic and hydrophobic functional groups, which could enhance its selectivity and adsorption capacity. After a series of synthetic processes, a magnetic polydopamine adsorbent (Fe3O4@PDA-DES) was prepared and applied in MSPE coupled with ultra-high-performance liquid chromatography (UPLC) for the determination of sulfonylurea herbicide in aqueous samples. The synthesized magnetic material was confirmed systematically through a series of characterization methods. The extraction parameters such as adsorbent dosage, ionic strength, and sample pH value were optimized.

Experimental

Chemicals and materials

All reagents used in the experiments were analytical grade or chromatographic grade. ChCl and ethylene glycol (EG) were obtained from Shanghai Aladdin Bio-Chem Technology Co. Ltd. (Shanghai, China). Dopamine (DA) was obtained from Tianjin Xiens Biochemical Technology Co., Ltd. (Tianjin, China). Potassium bromide (KBr), FeCl3·6H2O, FeCl2·4H2O, HCl, NaOH, anhydrous ethanol, ammonia and sodium chloride were analytical grades and obtained from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). HPLC (high-performance liquid chromatography) grade acetonitrile (ACN) and methanol (MeOH) were provided by Fisher Chemistry Reagent Co. Ltd. (Waltham, USA). Sodium dodecyl sulfate (SDS) was achieved from Xilong Chemistry Co. Ltd. (Shantou, China). Ammonium persulfate (APS) and N,N-methylenebisacrylamide (MBAAm) were purchased from Fucheng Chemicals (Tianjin, China). Tetraethyl orthosilicate (TEOS) was obtained from Alfa Aesar (Waltham, USA). High-purity deionized water (18.2 MΩ cm) purified by a Milli-Q water purification system (Millipore, Bedford, MA, USA) was used. Sulfosulfuron, bensulfuron-methyl, pyrazosulfuron-ethyl and halosulfuron-methyl were obtained from the Testing Center of the Shanghai Pesticide Research Institute (Shanghai, China) with purity over 95%. Stock standard solutions of target pesticides were prepared at 1.0 g L-1 in methanol. The stock and working standard solutions were stored in dark at 4 °C until use.

Apparatus and analytical conditions

The detection process was performed with an ultra-performance liquid chromatography (Nexera X2 Shimadzu, Japan) equipped with an SPD-M30A PDA detector, an LC-30AD quaternary pump system, an SIL-30AC auto sampler, and a CTO-30A thermostatic column compartment. Chromatographic separation of the analyte was carried out on a Waters Acquity UPLC BEH C18 column (100 × 2.1 mm, 1.7 µm). The mobile phases were 0.1% formic acid (solvent A) and acetonitrile (solvent B). The analytes were separated with the following gradient program: 0 min, 30% B; 0-11.0 min, 30-60% B; 11.0-15.0 min, 60-90% B; 15.0-16.0 min, 90-30% B; 16.0-20 min, 30% B. The flow rate was set at 0.45 mL min-1. The sample injection volume was 20 µL. Absorbance was monitored at 254 nm and the column temperature was held constant at 35 °C. Fourier transform-infrared spectrometer (FTIR, Model Nexus 470, Nicolet USA) and KBr were used to identify functional groups of the magnetic microspheres. The morphologies of adsorbent were characterized on a scanning electron microscopy (SEM) instrument (Model 8010, Tian Mei Instrument Co., Ltd., China). The magnetic measurements were conducted using a vibrating sample magnetometer (Model PPMS-9 Squid-VSM, Quantum Design, USA). The magnetic moments were measured under applied magnetic fields varying from -2000 to +2000 G at 300 K.

Synthesis of magnetic nanocomposite

Preparation of DES

Choline chloride and ethylene glycol were accurately weighed at 1:2 M ratio and combined in a 100 mL round-bottom flask. Then, the mixture was stirred at 80 °C for 1 h until a clear liquid was obtained. After cooling, the DESs were stored at room temperature.

Preparation of Fe3O4 nanoparticles

Fe3O4 nanoparticles were prepared by the well-known coprecipitation method.2828 Wang, X.; Li, G.; Row, K. H.; Electrophoresis 2018, 39, 1111. 5.2 g FeCl3·6H2O and 2.0 g FeCl2·4H2O were dissolved in 160 mL ultrapure water which was degassed with nitrogen gas to agitate the mixture. Then, 30 mL NH3·H2O was added to the solution. The mixture was kept in a magnetic stirrer at 80 °C for 50 min with vigorous stirring. Black particles were recovered by an external magnet after washing by ultrapure water. Finally, the mixture was dried in a 60 °C vacuum oven for 12 h to achieve the Fe3O4 nanoparticles.

Preparation of Fe3O4@PDA

Fe3O4@PDA was prepared according to the reported literature.2929 Tao, Z.; Zhang, X. L.; Niu, H. Y.; Appl. Catal., B 2013, 134, 26. The prepared Fe3O4 nanoparticles (400 mg) were dispersed in 250 mL Tris buffer solution (pH = 8.5) containing 400 mg dopamine. The mixture was continuously sonicated for 30 min in water bath and reacted at room temperature for 10 h. Under alkaline condition, Fe3O4 nanoparticles were introduced into PDA to form Fe3O4@PDA nanoparticles. Fe3O4@PDA nanoparticles were collected by magnet separation and washed with deionized water and ethanol. At last, the nanoparticles were dried in a vacuum oven at 60 °C.

Preparation of Fe3O4@PDA-DES

Fe3O4@PDA-DES were prepared through a seed emulsion polymerization method.3030 Xu, K. J.; Wang, Y. Z.; Li, Y. X.; Anal. Chim. Acta 2016, 946, 64. 500 mg Fe3O4@PDA was dispersed into 210 mL deionized water and 40 mL ethanol. 50 mg SDS was added into the mixture and stirred at room temperature for 30 min. Then, 5 mL DES and 200 mg MBAAm were added, followed by continuously bubbling with N2 for 30 min. When the mixture was heated to 65 °C, 2.5 mL APS solution having a concentration of 0.02 g mL-1 was added to the dispersion to initiate polymerization. Reaction was continued for 10 h. Finally, the obtained chemical product was collected, washed with deionized water and dried overnight at 40 °C to get the final magnetic material.

Magnetic solid-phase extraction procedures

100 mL water sample containing 10 µg L-1 target analytes was placed in a 250 mL conical bottle. Then, 1.5 g of NaCl was added and the sample pH was adjusted to 3.0 with 1 M HCl. 200 µL methanol were added into 50 mg of magnetic adsorbent and mixed for a while to activate the magnetic adsorbent. Then, the magnetic adsorbent activated was added into the sample. After 5 min of ultrasonic extracting, the sample was allowed to stand for 20 min. The Fe3O4@PDA-DES entrapped analytes by weak van der Waals forces and electrostatic interactions,3131 Lawal, I. A.; Klink, M.; Ndungu, P.; Environ. Res. 2019, 179, DOI 10.1016/j.envres.2019.108837.
https://doi.org/10.1016/j.envres.2019.10...
and then they were separated from the sample solution by an external magnet, and the sample solution became limpid and the upper clear liquid was decanted. Subsequently, the analytes were eluted with 1.5 mL of methanol under a vortex mixer. The eluent was collected in a 2 mL centrifuge tube and blown dry under a nitrogen atmosphere at 40 °C. Finally, 200 µL acetonitrile was added for the reconstitution of analytes and filtered through a 0.22 µm membrane before analysis by UPLC.

Method validation

Under the optimum conditions, the proposed MSPE-UPLC method was validated according to the linearity, correlation coefficient, limit of detection (LOD), limit of quantitation (LOQ) and relative standard deviations (RSD). The linearity was obtained by using five points in the concentration range of 1-200 µg L-1. The repeatability was expressed as RSDs for three replicate analyses. The LOD was evaluated based on signal-to-noise ratio (S/N) of 3. The enrichment factor (EF) was the ratio between the concentration of the analytes in the extraction solvent and the concentration of the analytes in the sample. The EF value was used to evaluate the extraction performance of the MSPE.

Analysis of water samples

In order to evaluate the applicability of our recommended method, six liquid samples were collected and analyzed. Lake water samples were collected from Nanhu Lake and Yezhihu Lake (Hongshan District, Wuhan). Rice field water sample was obtained from the experimental field of Huazhong Agricultural University. The lake water and the rice water samples were filtered through medium-speed qualitative filter papers. Three drinking water samples were purchased from supermarket of Huazhong Agricultural University, and their brand were Wahaha, Nongfu Spring and Yibao. All water samples were analyzed within 24 h of collection and stored in dark containers at 4 °C.

Results and Discussion

Characterization of Fe3O4@PDA-DES

To confirm the structure of Fe3O4@PDA-DES, FTIR spectra of Fe3O4, Fe3O4@PDA, and Fe3O4@PDA-DES were examined and the results were presented in Figure 1. The absorption peaks of DES appearing at 2923 and 2854 cm-1 were belonged to -CH3 and -CH2 groups. The peak intensity of the bending vibration of -H on the benzene ring of the PDA was located at a wavenumber of about 1506 cm-1. The peak at 1293 cm-1 was from the characteristic absorption of C-N. The peak at about 586 cm-1 was associated with the stretching vibrations of Fe-O. It can be obviously seen that the synthetic material contains these characteristic peaks. Based on the above results, DES was confirmed to be involved in the synthesis of magnetic polydopamine.

Figure 1
FTIR spectra (KBr) of (a) Fe3O4; (b) Fe3O4@PDA and (c) Fe3O4@PDA-DES.

The scanning electron microscopy image of Fe3O4@PDA-DES was shown in Figure 2. It can be seen that the surface of this magnetic composite material was rough and more irregular which proved that the DES was successfully bonded.

Figure 2
Scanning electron microscopy image of Fe3O4@PDA-DES.

Magnetism is a key factor for magnetic materials. Magnetization curves of two materials are listed in Figure 3. The saturation magnetization of Fe3O4@PDA, Fe3O4@PDA-DES gradually decreased to 50.9 and 43.2 emu g-1, respectively. The lessening of saturation magnetization in Fe3O4@PDA-DES can be attributed to DES successfully formed on the surface of Fe3O4@PDA. The prepared magnetic Fe3O4@PDA-DES has sufficient saturation magnetization to make it sensitive to magnetic fields. In addition, the magnetic material was susceptible to external magnetic fields, which resulted in rapid separation during MSPE process.

Figure 3
Room temperature magnetization curve of Fe3O4@PDA and Fe3O4@PDA-DES.

Optimization of extraction conditions

Several experimental variables that affected the extraction efficiencies were investigated, including the extraction time, adsorbent consumption, ionic strength, sample pH value, and desorption conditions. In all optimization experiments, 10 µg L-1 of each analyte was added and the above mentioned variables were modified one at a time while keeping the remaining constants.

Optimization of extraction time

The effect of extraction time on the performance of MSPE is an important factor. It takes a certain time for the extraction solvent to be dispersed into the aqueous samples. Too short extraction time may result in incomplete extraction, and too long might cause difficulty in elution. Therefore, the effect of extraction time was evaluated over the time range between 5 and 25 min. Analyzing the results shown in Figure 4, 20 min was the proper time for the magnetic material to achieve optimal adsorption of the target compounds. Therefore, 20 min was chosen as the extraction time for the following studies.

Figure 4
Effect of extraction time on the extraction efficiency of SUHs.

Optimization of adsorbent consumption

One of the key factor of the adsorption process is the amount of adsorbent, which could affect the adsorption between the adsorbent and the target analytes. A series of adsorbent amount (10-50 mg) were weighed to evaluate the effect of adsorbent consumption on the extraction efficiencies. Results shown in Figure 5 indicated that the highest extraction efficiencies were achieved when 50 mg adsorbent was added. When the dose of the adsorbent was increased, the herbicides interacted more with the adsorbent. Meanwhile, the recoveries have satisfied the requirements of residue analysis.3232 Ye, L.; Wang, Q.; Xu, J.; Shi, Z. G.; Xu, L.; J. Chromatogr. A 2012, 1244, 46. Thus, 50 mg of adsorbent dose was selected.

Figure 5
Effect of adsorbent dosage on the extraction efficiency of SUHs.

Optimization of ionic strength

In order to study the effect of the ionic strength on the performance of the presented MSPE procedure, the adding amount of NaCl varying from 0 to 2 g were investigated. The results were given in Figure 6, leading to increased efficiencies as the NaCl content increased from 0 to 1.5 g. When 2 g of NaCl was added, the extraction efficiencies of the target analytes decreased. The reason for this maybe excessive salt ions could increase the viscosity of the solution, which made the adsorbent transfer less from the aqueous phase to the surface of the target analytes and reduced the extraction effects. Thus, the subsequent extractions were accomplished with samples containing 1.5 g NaCl.

Figure 6
Effect of ionic strength on the extraction efficiency of SUHs.

Optimization of solution pH value

Generally, the pH value of sample plays a significant role for the adsorption efficiencies. The molecular state of target analytes could be affected by the solution pH value. In this study, the pH value was adjusted with HCl and NaOH solution and the effect of pH value was investigated by varying the sample pH from 3.0 to 7.0. According the obtained data (Figure 7), we can conclude that the extraction efficiencies increased when the pH value decreased. This can be explained by the fact that sulfonylurea herbicides are generally weak acidic with pK a values ranging from 3.0 to 5.0. When the pH value of the sample solution was higher than 5.0, the hydrophobicity of the compounds was reduced, and thus the recoveries rate were reduced. Ultimately, the pH value of the sample solution was adjusted to 3.0.

Figure 7
Effect of pH value of the solution on the extraction efficiency of SUHs.

Selection of desorption conditions

Different eluents have different effects on the extraction efficiencies. Suitable elution solvent and volume can fully elute the target analytes, reduce matrix interference and improve extraction efficiencies. The effects of methanol, acetonitrile and acetone on the extraction efficiencies were investigated. As shown in Figure 8 (taking sulfosulfuron as an example), methanol has the best elution ability and the recoveries for SUHs were higher than other elution solvents. Therefore, methanol was chosen as the eluting solvent in the further study.

Figure 8
Effect of type and volume of desorption solvent on the extraction efficiency of sulfosulfuron.

In order to completely elute the target pesticides on the adsorbent, the volume of elution solvent was studied. From Figure 8 we found that the extraction efficiencies increased when the volume of solvent increased until 1.5 mL. After that, the extraction efficiencies began to decrease. Thus, based on the above results methanol was selected as the extraction solvent, and the amount of eluent was fixed at 1.5 mL.

Method validation

Under the optimal conditions, the reliability of the proposed method was appraised by measuring various analytical parameters which included linearity, repeatability, LODs, and enrichment factors. The results were summarized in Table 1. A series of water solutions spiked with six SUHs at different concentrations were prepared to establish the calibration curves. Good linearities were achieved in all cases with the regression coefficients varying from 0.9927 to 0.9986. The repeatability was achieved by spiking samples at a concentration level of 10 µg L-1, the relative standard deviations (RSDs, n = 3) ranged from 1.4 to 4.3%, implying that the present method was precise and could meet the requirements of the analysis. The LODs, based on signal-to-noise ratio (S/N) of 3, ranged from 0.0092 to 0.0113 µg L-1. The enrichment factors were between 495 and 615.

Table 1
Correlation coefficients, linear ranges, RSDs, EF and LODs of the SUHs

Real samples

To investigate the applicability of the developed method to actual samples, the proposed method was applied to the determination of SUHs in environment and drinking water samples. The results showed that all the target analytes were not found in all the water samples. To evaluate the matrix influence on the proposed method, the environmental and drinking water samples were spiked with SUHs at concentration levels of 10 and 50 µg L-1 and the data were generalized in Tables 2-3. The recoveries ranged from 61.9 to 100.1% with the RSDs (n = 3) varying from 1.2 to 6.1% for three environmental water samples, and from 71.7 to 101.9% with the RSDs (n = 3) varying from 1.0 to 4.9% for three drinking water samples. From the results we can discover that matrices of experimental waters samples have no evident influence. These results demonstrated that Fe3O4@PDA-DES was a promising alternative adsorbent for MSPE, and the presented MSPE-UPLC method can be applied for the isolation and determination of SUHs in water samples.

Table 2
Spiked recoveries and RSDs of five SUHs in the environmental water samples
Table 3
Spiked recoveries and RSDs of five SUHs in the drinking water samples

Comparison of the MSPE-UPLC method with other methods

There are a lot of researches about the methods of determining SUHs in water samples. In the present study, a comparison between the developed method and other methods was performed. Table 4 shows the LODs, the RSDs, and the volume of the organic solvent required in magnetic solid phase extraction-high performance liquid chromatography-diode array detector (MSPE-HPLC-DAD),3333 Ma, J.; Jiang, L.; Wu, G.; J. Chromatogr. A. 2016, 1466, 12. solid phase extraction-high performance liquid chromatography-ultraviolet (SPE-HPLC-UV),3434 Shi, J.; Li, X.; Liu, C.; Shao, M.; Zhang, H.; Zhang, H.; Yu, A.; Chen, Y.; Chromatographia 2014, 77, 1283. salting-out assisted liquid-liquid extraction-high performance liquid chromatography-diode array detector (SALLE-HPLC-DAD).3535 Gure, A.; Lara, F. J.; David, M. G.; Talanta 2014, 127, 51. It was obvious that under the optimum conditions, the LODs, RSDs and organic solvent obtained in proposed method were better than previous works. These results illustrated that MSPE-UPLC was an efficient and environmentally friendly method.

Table 4
Comparison of the proposed method with other analytical techniques for determination of SUHs in water samples

Conclusions

A simple and sensitive MSPE method coupled with UPLC has been developed. The prepared DES (ChCl / EG) was applied to a magnetic polydopamine composite materials (Fe3O4@PDA-DES) and for the first time to be used as adsorbents to selectively extract SUHs during MSPE process. The results showed that the method had the advantages of low detection limit, high precision, good recoveries and high enrichment factors, which could meet the residue analysis requirements of SUHs. In the final experiment, the developed method was applied to the determination of SUHs in real samples and the acceptable results can be achieved. Considering all of its advantages, MSPE has potential to be applied in the field of pesticide residue analysis. In addition, it provides a novel choice for the pretreatment of complex matrix samples.

Acknowledgments

The present study was supported by grants from the National Key R&D Program of China (2017YFD020030803) and National Natural Science Foundation of China (No. 21507032).

References

  • 1
    Fang, G.; Chen, J.; Wang, J.; J. Chromatogr. A 2010, 1217, 1567.
  • 2
    Yan, C.; Zhang, B.; Liu, W.; J. Chromatogr. B: Anal. Technol. Biomed. Life Sci. 2011, 879, 3484.
  • 3
    Fenoll, J.; Hellín, P.; Sabater, P.; Talanta 2012, 101, 273.
  • 4
    Wu, Q.; Wang, C.; Liu, Z.; J. Chromatogr. A 2009, 1216, 5504.
  • 5
    Tang, K.; Chen, S.; Gu, X.; Anal. Chim. Acta 2008, 614, 112.
  • 6
    Safarikova, M.; Safarik, I.; J. Magn. Magn. Mater. 1999, 194, 108.
  • 7
    Wang, D. D.; Zhao, Y.; Ou-yang, M. N.; Guo, H. M.; Yang, Z. H.; J. Chromatogr. A 2019, 1601, 53.
  • 8
    He, Z.; Liu, D.; Li, R.; Anal. Chim. Acta 2012, 747, 29.
  • 9
    Ma, J.; Jiang, L.; Wu, G.; J. Chromatogr. A 2016, 1466, 12.
  • 10
    Zhang, L.; Wu, J.; Wang, Y.; J. Am. Chem. Soc. 2012, 134, 9879.
  • 11
    Qin, Y.; Wang, M.; Sun, Z.; J. Mater. Chem. B 2013, 1, 6085.
  • 12
    Qian, Y.; Feng, Z.; Liu, W.; Chem. Soc. Rev. 2011, 40, 4244.
  • 13
    Zheng, Q.; Lin, T.; Wu, H.; Int. J. Pharm. 2014, 463, 22.
  • 14
    Lai, G.; Zhang, H.; Yong, J.; Biosens. Bioelectron. 2013, 47, 178.
  • 15
    Xia, Z.; Lin, Z.; Xiao, Y.; Biosens. Bioelectron. 2013, 47, 120.
  • 16
    Liu, R.; Sha, M.; Jiang, S.; Talanta 2014, 120, 76.
  • 17
    Wang, X.; Song, G.; Deng, C.; Talanta 2015, 132, 753.
  • 18
    Erbas, Z.; Soylak, M.; Yilmaz, E.; Dogan, M.; Microchem. J. 2019, 145, 745.
  • 19
    Abbott, A. P.; Capper, G.; Davies, D. L.; Rasheed, R. K.; Tambyrajah, V.; Chem. Commun. 2003, 9, 70.
  • 20
    Smith, E. L.; Abbott, A. P.; Ryder, K. S.; Chem. Rev. 2014, 114, 11060.
  • 21
    Abbott, A. P.; Cullis, P. M.; Gibson, M. J.; Green Chem. 2007, 9, 868.
  • 22
    Hammond, O. S.; Bowron, D. T.; Edler, K. J.; Green Chem. 2016, 18, 2736.
  • 23
    Gore, S.; Baskaran, S.; Koenig, B.; Green Chem. 2011, 13, 1009.
  • 24
    Sebastián, P.; Torralba, E.; Vallés, E.; Electrochim. Acta 2015, 164, 187.
  • 25
    Gulsah, S. K.; Erkan, Y.; Mustafa, S.; J. Iran. Chem. Soc. 2018, 15, 2307.
  • 26
    Karimi, M.; Hesaraki, S.; Alizadeh, M.; Ceram. Int. 2016, 42, 2780.
  • 27
    Abdul, H. N.; Ng, M. H.; Choo, Y. M.; J. Am. Oil Chem. Soc. 2015, 92, 1709.
  • 28
    Wang, X.; Li, G.; Row, K. H.; Electrophoresis 2018, 39, 1111.
  • 29
    Tao, Z.; Zhang, X. L.; Niu, H. Y.; Appl. Catal., B 2013, 134, 26.
  • 30
    Xu, K. J.; Wang, Y. Z.; Li, Y. X.; Anal. Chim. Acta 2016, 946, 64.
  • 31
    Lawal, I. A.; Klink, M.; Ndungu, P.; Environ. Res. 2019, 179, DOI 10.1016/j.envres.2019.108837.
    » https://doi.org/10.1016/j.envres.2019.108837
  • 32
    Ye, L.; Wang, Q.; Xu, J.; Shi, Z. G.; Xu, L.; J. Chromatogr. A 2012, 1244, 46.
  • 33
    Ma, J.; Jiang, L.; Wu, G.; J. Chromatogr. A. 2016, 1466, 12.
  • 34
    Shi, J.; Li, X.; Liu, C.; Shao, M.; Zhang, H.; Zhang, H.; Yu, A.; Chen, Y.; Chromatographia 2014, 77, 1283.
  • 35
    Gure, A.; Lara, F. J.; David, M. G.; Talanta 2014, 127, 51.

Publication Dates

  • Publication in this collection
    03 July 2020
  • Date of issue
    July 2020

History

  • Received
    03 Nov 2019
  • Accepted
    10 Mar 2020
Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
E-mail: office@jbcs.sbq.org.br