Acessibilidade / Reportar erro

ETHANOL DEHYDRATION IN PACKED DISTILLATION COLUMN USING GLYCEROL AS ENTRAINER: EXPERIMENTS AND HETP EVALUATION

Abstract

The ethanol-water separation is very important because ethanol is widely applied in the chemical industry and its use as a fuel can reduce the pollution emitted to the air. However, anhydrous ethanol production using conventional distillation is impossible, at atmospheric pressure, due to the presence of an azeotrope. In the present work, experimental tests were carried out in order to evaluate the use of glycerol as an entrainer, in substitution of ethylene glycol in an extractive distillation. The use of glycerol is motivated by the biodiesel production units, due to the fact that it is the main byproduct and a new market is necessary to consume its overproduction. The experiments were carried out in a distillation column packed with Raschig rings, varying the glycerol/feed (ethanol and water) ratio, S/F, from 0.5 to 0.9. The samples were analyzed using a digital densimeter. The results showed that glycerol was effective to promote ethanol dehydration and the presence of an azeotrope was not observed using a solvent to feed ratio (S/F) equal to 0.9. Some empirical correlations were investigated to evaluate the HETP (Height Equivalent to a Theoretical Plate), and the results provided a useful tool for designing a packed bed column for ethanol-water separation.

Keywords:
Extractive distillation; Packing; Azeotrope; Mass transfer; Biofuel

INTRODUCTION

In recent years increasing efforts have been made to produce biofuels in order to replace fossil fuels. This tendency is confirmed by the high investment and numerous researches in this area. Moreover, fossil fuels are associated with environmental problems and subjected to high price volatility. Besides biodiesel, ethanol is also a good choice to replace petroleum fuels, since it has already been used as an addictive to gasoline or to completely substitute this fuel. In Brazil, for example, according to the government laws gasoline must be mixed with 22-27% of anhydrous ethanol. Another reason to use ethanol is that it is a clean-burning fuel and reduces the air pollution.

Ethanol uses are not restricted to fuel applications; for example, in the chemical industry ethanol is widely used as an important reactant, an intermediate compound or solvent to produce products of industrial interest (perfumes, paints, detergents, aerosols and medicines). Moreover, biodiesel can also be produced by using anhydrous ethanol as reactant (Gil, 2008Gil, I. D., Uyazán, A. M., Aguilar, J. L., Rodríguez, G., Caicedo, L. A., Separation of ethanol and waterby extractive distillation with salt and solvent as entrainer: Process simulation. Brazilian Journal of Chemical Engineering, 25(1), p. 207-215 (2008).).

Considering such information, the ethanol-water separation process is not only important, but it is necessary. However, production of anhydrous etha- nol is not feasible by using conventional distillation at atmospheric pressure, due to the formation of an azeotrope. There are several alternative processes that can be used to produce absolute ethanol, and one of the most applied is extractive distillation due to the lower energetic consumption and lower investment and operational costs (Uyazán, 2006Uyazán, A. M., Gil, I. D., Aguilar, J. L., Rodríguez, G., Caicedo, L. A.,Producción de alcohol carburante por destilación extractiva: simulación del proceso con glycerol. Ingeniería e Investigación, 26(001), p. 45-50(2006). (In Spanish).).

Summarizing, extractive distillation is the vaporization of a mixture with addition of a high boiling point compound, known as a separating agent, solvent or entrainer, in order to change the relative volatilities of the original mixture. The mechanism associated with this phenomenon is the selective molecular association of the solvent with one of the components of the mixture in the liquid phase. As a result, a given separation can be achieved using smaller distillation columns and azeotropes can be "broken" (Further, 1974; Perry and Chilton, 1980Perry, R. H., Chilton, C. H.,Manual de Engenharia Química. 2ª Ed., Editora Guanabara Dois S.A.Rio de Janeiro(1980). (In Portuguese).).

Since the entrainer does not form an azeotrope with any of the original compounds, its regeneration is carried out in a second distillation column in order to promote the recycling to the extractive column. The solvent recovery in extractive distillation is easier than in azeotropic distillation. In addition, extractive distillation is simpler and more widely applied than azeotropic distillation (Perry and Chilton, 1980Perry, R. H., Chilton, C. H.,Manual de Engenharia Química. 2ª Ed., Editora Guanabara Dois S.A.Rio de Janeiro(1980). (In Portuguese).).

It is worth to mention that, in the past, several separating agents were proposed to dehydrate ethanol in order to achieve energy savings and/or substitute a toxic solvent. Benzene, for example, was widely used as separating agent, but due to its toxicity and adverse health effects, today this practice is against the law. Ethylene glycol is the usual solvent to promote absolute ethanol recovery, since it is a relatively low toxicity compound (Ravagnani et al., 2010Ravagnani, M. A. S. S., Reis, M. H. M., Filho, R. M., Wolf-Maciel, M. R., Anhydrous ethanol production by extractive distillation: A solvent case study. Process Safety and Environmental Protection, 88, p. 67-73(2010).).

In this context, the present work proposes the use of glycerol as entrainer for the ethanol-water separation process. Since glycerol is a co-product of biodiesel processing, its production is increasing greatly and, as a result, there are several researches on glycerin applications. The use of glycerin as a separating agent for ethanol dehydration may suggest an important integrated process concept, known as biorefinery. Packed distillation columns of small diameters can be employed since they are, generally, cheaper than the plate columns.

The design of a packed bed is based on the HETP concept, which is a function of mass transfer coefficients and the effective interfacial area. In this work, some of the most applied general HETP correlations were evaluated in order to use the best one as a tool for providing useful information for the scale-up procedure.

PREVIOUS WORK

Schneible (1923) was the first to use glycerol as an entrainer to dehydrate ethanol. The author proposed a continuous process using a plate distillation column, with a spray of glycerol being charged into the top of the extractive column.

The engineer Mariller (1924) proposed an absorption process to dehydrate ethanol using a plate distillation column. This process is similar to that proposed by Schneible (1923), the feed condition, vapor of hydrated ethanol, being one of the most important differences. This process was used in Europe up to 1960 and was forgotten due to economic and technical problems, especially degradation and the high cost of glycerol (Drummond, 2004).

Lee and Pahl (1985)Lee, F. M., Pahl, R. H.,Solvent screening study and conceptual extractive distillation process to produce anhydrous ethanol from fermentation broth. Ind. Eng. Chem. Process Des. Dev., 24, p. 168-172(1985). studied the effect of 11 potential solvents to "break" the ethanol-water azeotrope and concluded that the glycols are the best solvents to eliminate the azeotrope, being glycerol the most effective one.

Gil et al. (2005) studied the use of a mixture of glycerol-ethylene glycol as entrainer for ethanol dehydration by extractive distillation. The authors used the software Aspen Plus to simulate a continuous process with two distillation plate columns: an extractive and a solvent regeneration one. They varied the composition of the entrainer and it was concluded that glycerol is more effective than ethylene glycol.

Uyazán et al. (2006)Uyazán, A. M., Gil, I. D., Aguilar, J. L., Rodríguez, G., Caicedo, L. A.,Producción de alcohol carburante por destilación extractiva: simulación del proceso con glycerol. Ingeniería e Investigación, 26(001), p. 45-50(2006). (In Spanish). simulated the use of glycerol for ethanol dehydration using the software Aspen Plus. The process simulated was constituted of two continuous distillation plate columns, like the process simulated by Gil et al. (2005). Uyazán et al. (2006)Uyazán, A. M., Gil, I. D., Aguilar, J. L., Rodríguez, G., Caicedo, L. A.,Producción de alcohol carburante por destilación extractiva: simulación del proceso con glycerol. Ingeniería e Investigación, 26(001), p. 45-50(2006). (In Spanish). demonstrated that the use of glycerol allows anhydrous ethanol production using smaller distillations columns and the energy consumption is lower than using ethylene glycol.

Dias et al. (2008) simulated an alternative continuous process to produce absolute ethanol using the software UniSim. The proposal of the authors is constituted by a single plate distillation column, operating under vacuum in order to avoid decomposition of the glycerol. According to the authors, this proposal allows investment and operational cost savings. However, it was demonstrated that this configuration is more economical when using ethyleneglycol.

From the studies presented, glycerol appears to be a suitable solvent for obtaining anhydrous ethanol. Nowadays there are many simulation studies about the use of glycerol as entrainer to dehydrate ethanol, instead of experimental works. In all works mentioned, plate columns were used to obtain anhydrous ethanol. Packed distillation columns have the advantage of lower cost in comparison to plate columns and can be easily used in small industrial distillation units.

Due to all that was cited above, the aim of this work was to study ethanol dehydration in a batch extractive distillation column using glycerol as entrainer. Experiments were carried out in a distillation column packed with Raschig rings in order to study the influence of glycerol on the ethanol-water vapor-liquid equilibrium. The column performance was evaluated by HETP calculation using the generalized correlations of Onda et al. (1968Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968)., Bolles and Fair (1982)Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982). and Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982)., because they have been largely used in packed bed design.

MATERIALS AND METHODS

Chemicals

The solutions used in this work were prepared with glycerol (99.5% minimum purity), absolute ethanol (minimum 99.8% purity), and distilled water. The binary systems were ethanol-water mixtures containing 0.20, 0.40, 0.60 and 0.85 ethanol mole fractions, with three different solvent to feed ratios (S/F): 0.5, 0.7 and 0.9 in weight fraction. These values of S/F were chosen according to Furter (1974)Furter, W. F.,Extractive distillation by salt effect. Extractive and azeotropic distillation. Advances in Chemistry Series, 115, American Chemical Society, Washington, DC(1974)., based on the fact that liquid separator agents are generally present between 50 and 90% of the liquid phase.

Experimental Apparatus

Figure 1 show the experimental unit used in this work. The experimental tests were performed in a laboratory scale distillation column with a packed section (37 cm height and 5.9 cm of internal diameter) containing Raschig rings made of glass and nominal size of 0.73 cm. Temperature was checked with thermometers placed at the top and at the bottom of the packed section. The unit contains a condenser, a serpentine type, with 50 cm height, and the reboiler is a 6 L unit with 750 W of heat supply. Samples of the studied mixture were taken from two valves, placed at the top and at the bottom of the packed section.

Figure 1
Packed distillation column used in this work: 1) feed point; 2) heat supplier; 3) reboiler; 4) liquid temperature measurement; 5) vapor temperature measurement; 6) bottom thermometer; 7) packed section; 8) Background sampling; 9) top sampling; 10) condenser; 11/12) inlet and outlet temperatures measurements of condenser; 13) top thermometer; 14) selector and indicator of the temperature

Sample Analysis

The composition of the samples was obtained using the experimental measurements of specific mass, using a digital densimeter (GEHAKA, DSL 920 model). A previous calibration curve was obtained by preparing ethanol-water mixtures of known mole composition and analyzing in the digital densimeter. The values of specific mass of these mixtures were adjusted with a fifth-order polynomial. The calibration curve obtained for the specific mass of the ethanol-water system was used to determine the ethanol mole fractions of the samples.

Experimental Procedure

Initially ethanol, water and glycerol were charged into the reboiler according to the ethanol-water composition mixtures and S/F relations studied. The heat supply was turned on and, after the first reflux on the top, the system was operated under total reflux during 2.5 hours and the temperature was registered every 15 minutes. It was observed that this operation time was sufficient, since the temperature remained constant during at least 30 min. After this time, samples of the mixture were collected at the top and the bottom of the packed section and analyzed in the digital densimeter. All runs were carried out at atmospheric pressure.

HETP Calculation

The packed bed design is based on the HETP concept, according to Equation (1). HETP values are a measure of the packing efficiency in such a way that, when HETP values decrease, the packing efficiency increases. The height of a packed bed can be calculated from Equation (1).

HETP values depend on mass transfer coefficients, which are related to HETP by Equation (2). In this equation the effect of mass transfer is represented by the height of an overall mass transfer unit, HOV, given by Equation (3).

The mass transfer coefficients are related to the height of the liquid and vapor phases in the transfer unit by Equations (4) e (5).

The overall transfer unit method used to estimate HETP is widely applied because it is mathematically simple and provides reliable results when using appropriate safety factors (Caldas and Lacerda, 1988Caldas, J. N., Lacerda, A. I., Torres Recheadas. JR Editora Técnica Ltda., Rio de Janeiro (1988). (In Portuguese).). Several empirical correlations have been proposed over the years in order to allow the estimation of HETP by this method.

HETP Correlations - Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968).

Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). presented empirical equations for the mass transfer coefficients of the vapor and liquid phases. They also developed a correlation for the wetted area, taking into account the liquid surface tension that can be applied, with a deviation of ±20%, to a packing column with Raschig rings, Berl saddles and spheres. The interfacial area equation is general, because it takes into account the packing material. The proposed correlations are shown in Equations (6), (7) and (8), with the dimensionless parameters calculated by Equations (9), (10) and (11).

HETP Correlations - Bolles and Fair (1982)Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982).

These authors extended the data bank used by Cornell et al. (1960)Cornell, D., Knapp, W. G., Fair, J. R., Mass transfer efficiency packed columns part 1. Chemical Engineering Progress, 56(7), p. 68-74(1960). and developed an improved model for the height of a transfer unit using 545 observations, obtained from 13 original sources. This data bank covers a wide range of operating conditions, different column diameters, and packing types. Instead of mass transfer coefficients, the authors correlated physical properties, packing dimensions and hydrodynamic factors to the height of a transfer unit of liquid and vapor phases. The model proposed is shown in Equations (12) and (13). In these equations the mass transfer influence is expressed by the Ψ and Φ constants, which are obtained graphically and depend on flood point estimation. The m and n constants are, respectively, 1.24 and 0.6 for Raschig rings and 1.11 and 0.5 for Berl saddles. The factors f1, f2 and f3 are calculated from Equations (14), (15) and (16).

HETP Correlations - Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982).

Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982). presented a correlation for effective area of mass transfer (Equation (17), specific for distillation processes. These authors evaluated 231 runs covering 11 systems from the Bolles and Fair (1982)Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982). data bank. The model does not require the flooding information and can be applied to any regular packing with a deviation of ±20%. Equation (17) requires the calculation of the dimensionless parameters given by Equations (18) and (19). The mass transfer coefficients of the model proposed by Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982). were determined using the Shulman et al. (1955)Shulman, H. J., Ullrich, C. F., Proulx, A. Z., Zimmerman, J. O.,Performance of packedcolumns. II. Wetted and effective-interfacial areas, gas-and liquid phase mass transfer rates. AIChE Journal, 1(2), p. 253-258(1955). correlations (Equations (20) and (21) and Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). correlations.

RESULTS AND DISCUSSIONS

As explained previously, the experiments were done in triplicate using solutions of ethanol and water varying the ethanol content from 20 to 85% and varying the S/F ratios from 0.5 to 0.9. Figures 2, 3, 4 and 5 show the experimental results obtained in all cases studied. Experiments without glycerol were carried out in order to observe the solvent effect of the ethanol-water vapor-liquid equilibrium. All mole fraction values in the figures are represented on a solvent-free basis.

In order to evaluate the effect of glycerol as entrainer in the ethanol dehydration process, statistics tests were performed using the triplicate measurements obtained for each distillation process. The main parameters of the analysis of variance (ANOVA) for top and bottom products are shown in Tables 1 and 2, respectively.

Table 1
Analysis of variance of experimental data of top products (Fcritical Fcritical are the calculated and critical F-values, respectively. = 4.0661).
Table 2
Analysis of variance of experimental data of bottom products (Fcritical = 4.0661).

Figure 2
Experimental results of the feed with 0.2 ethanol mole fraction.
Figure 3
Experimental results of the feed with 0.4 ethanol mole fraction.
Figure 4
Experimental results of the feed with 0.6 ethanol mole fraction.
Figure 5
Experimental results of the feed with 0.85 ethanol mole fraction.

Based on the ANOVA results exhibited in Tables 1 and 2, the following conclusions can be deduced. Low values obtained for standard deviations (less than 3%), as well as for all coefficient of variations (less than 5%), indicate the good reproducibility of the experimental procedure, which means that the results presented in this work are reliable.

It can be observed that, when the ethanol mole fraction in the feed increases, the ethanol mole fractions in the top and bottom products also increase. This feature was already expected since as the ethanol content increases, the relative volatility of the ethanol-water system decreases.

Considering the experimental apparatus used, and the operational conditions investigated in this work, the calculated F-values and p-values indicate that the addition of solvent in the distillation column was effective, meaning that the use of glycerol promoted the enrichment of the original mixture in ethanol content. Only two exceptions were observed, the systems corresponding to xfeed = 0.6 (top) and xfeed = 0.2 (bottom), since they presented calculated F-values lower than the critical one (Fcritical = 4.0661), and p-values higher than 5%. The absence of a glycerol effect observed in the bottom section for xfeed = 0.2 probably occurred due to the low ethanol content in these feed solutions, making the separation process more difficult. On the other hand, the same behaviour observed in the top section for xfeed = 0.6 is not so obvious and will be properly discussed considering the Tukey's multiple comparison test presented below.

In order to verify the statistical difference among the products obtained at the top and bottom sections of the distillation column using different S/F ratios (i.e., the effect of glycerol on the separation process), the Tukey's multiple comparison test was performed and the results are summarized in Table 3. In this table, for a given xfeed, the same letters in the resulting ethanol fraction (x) indicate that the top and/or bottom products were not significantly different from each other.

Table 3
Tukey's test of experimental data for the top and bottom products.

From a broad analysis of the results exhibited in Table 3, it is possible to conclude that the effect of glycerol as entrainer was more effective in the bottom section of the distillation column, since there are more results that are statistically different from each other in this section. This can probably be explained due to the reduced dimension of the packed section of the distillation column, that provides only one separation stage, and to the fact that the column operates with no solvent flow in this section. Besides, considering the absence of glycerol in the packed section, the effect of glycerol on the feed composition only occurs in the reboiler.

In order to obtain complementary analysis of the glycerol effect on the distillation process, more information obtained from the Tukey's test is presented in Table 4. In this table, the signal "≠" indicates, for a given xfeed, which changes in the S/F ratios produced top and/or bottom products (x) significantly different from each other. The numbers in parentheses correspond to the p-value (bi-caudal) obtained from the Tukey's test for the associated pair of S/F ratios. The highlighted lines in Table 4 show the comparison between distillation products obtained from feed solutions without solvent to those obtained from feed solutions with different glycerol content, while the other lines show the comparison between distillation products obtained from feed solutions with different glycerol content.

Table 4
Effect of entrainer on distillation products in top and bottom sections.

From the results shown in the Table 4, it is possible to conclude that approximately 40% of the entire set of experiments produced ethanol mole fractions (top and bottom sections) statistically different from each other. It is also clear that the solvent effect was most effective in bottom section, which presented 54% of the results statistically different from each other. The corresponding result obtained in the top section is close to 25%.

Considering only the experiments where the distillation products obtained from feed solutions without solvent were compared to those obtained from feed solutions with different glycerol content (the highlighted lines in Table 4), 42% of the distillations produced results statistically different from each other. Again, the solvent effect was more effective in the bottom section, since 58% of these results are statistically different, against 25% in the top section.

It can also be concluded that the enrichment of the ethanol solution at the top section due to the solvent was only observed when the highest S/F ratio (90%) was used, since the p-value obtained for the result related to S/F ratio = 70% is too close to the required significance level, fixed at 5%. At the bottom section, the enrichment of the ethanol-water solutions due to the solvent effect was not observed in dilute feed solutions (xfeed = 0.2), while for feed solutions with intermediate ethanol content (xfeed = 0.4 and 0.6) this effect is present in all S/F ratios. However, for higher concentration feed solutions (xfeed = 0.85), the solvent effect was only observed for S/F ratio = 90%.

According to the results shown in Table 3, the azeotrope breaking was only obtained in the experiment corresponding to xfeed = 0.85 and S/F ratio = 90%, were top and bottom products exhibited ethanol mole fractions higher than the azeotropic composition (x = 0.916 and 0.913, respectively). This value of S/Fratio to break the azeotrope is in accordance with the simulation result found by Uyazán et al. (2006)Uyazán, A. M., Gil, I. D., Aguilar, J. L., Rodríguez, G., Caicedo, L. A.,Producción de alcohol carburante por destilación extractiva: simulación del proceso con glycerol. Ingeniería e Investigación, 26(001), p. 45-50(2006). (In Spanish)..

In this work, the results obtained from feed solution containing 85 mole% of ethanol were very promising, and indicate the proper operational conditions for producing anhydrous ethanol by using glycerol as entrainer. The results obtained from experiments without glycerol are in agreement with the results found by Jing et al. (2010). These authors studied the ethanol-water separation using a batch distillation column with a packed rectification section (25 cm of height and 30 mm of internal diameter) and a packed extractive distillation section (1 m of height and 30 mm of internal diameter). The packing used by the authors was Dixon rings with characteristic diameter of 3 mm. Operating under total reflux and starting from a feed containing 88 mole% of ethanol, Jing et al. (2010) observed the azeotrope composition in the absence of a separating agent. In the present work, starting from feed solution containing 85 mole% ethanol, and operating in the absence of glycerol, the azeotrope composition was also observed (see Table 3). The azeotropic mixture was also observed in experiments carried out with the same feed solution (xfeed = 0.85) and using S/F ratios of 50% and 70%, since the products obtained after distillation using these S/F ratios are not significantly different from that obtained in free-solvent conditions (see the highlighted lines in Table 4).

It should be remarked that ethanol was not produced in anhydrous condition probably due to the absence of glycerol in the packed section. This hypothesis can be better evaluated by the results found by Jing et al. (2010), since they used solvent (ethylene glycol) flow in the packed section and obtained products with higher ethanol content.

In addition, despite the use of a liquid separating agent, the absence of glycerol in all samples was observed. This result was confirmed because, when the S/F increases, the specific mass of the bottom and top products decreases. If glycerol was being dragged over, the expected tendency would be the increase of specific mass of the top and bottom products, since glycerol is heavier than ethanol and water. In addition, the temperatures measured in the packed section of the column during the experiments without solvent (about 80 ºC) were similar to the measurements obtained in the experiments using glycerol. This fact indicates that the products are free of entrainer, since the glycerol boiling point at 1 atm is 290 ºC (Reid et al., 1987Reid, R. C., Prausnitz, J. M., Poling, B. E.,The Properties of Gases and Liquids. 4th Ed., McGraw-Hill, Inc., New York(1987).). Finally, the absence of glycerol in all samples was also confirmed by a NMR (nuclear magnetic resonance) analysis. This feature is very important because the final product does not require any additional separation process.

HETP ESTIMATION RESULTS

In this section HETP values from the models (Onda et al., 1968Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968).; Bolles and Fair, 1982Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982).; Bravo and Fair, 1982Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982).) were predicted and compared with HETP pseudo-experimental, values calculated by Equation (22), where Z=37 cm and N is given by the Fenske equation (Henley and Seader, 1981Henley, E. J., Seader, J. D.,Equilibrium-Stage Separation Operations in Chemical Engineering. John Wiley & Sons, New York(1981).), which requires the experimental values of the compositions. Relative deviations (RD) between predicted and pseudo-experimental values were calculated by Equation (23). All physical properties required by generalized correlations were calculated according to Reid et al. (1987)Reid, R. C., Prausnitz, J. M., Poling, B. E.,The Properties of Gases and Liquids. 4th Ed., McGraw-Hill, Inc., New York(1987).. The evaluation of the HETP models was not done for the experiments using the feed with 85 mole% of ethanol. This was because the top and bottom samples were very similar in composition, causing some inconsistencies in the Fenske equation and in HETP models prediction.

Table 5 shows the results of HETP estimation obtained from the Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). correlation for all the systems investigated in the experimental section.

Table 5
HETP predicted from Onda et al. (1968).

It can be noted from Table 5 that the highest predicted value is 10.74 cm and the lowest is 9.01 cm, leading to a maximum difference of 1.73 cm. The reason that all the predicted values are close to each other is related to the proximity of the physical properties calculated for all cases. The lower deviation was 13.18% and the highest, 46.44% and the predictions were lower than the pseudo-experimental results. This behavior could occur because of the surface tension of the systems studied, since the ratio σC/ σL was outside the range of correlation applicability. If the surface tensions were greater, the application range would be respected and the estimate of the wetted area would be smaller. Consequently, the predicted HETP would increase, reducing the deviations.

Soares (2010) also evaluated the HETP of the experimental unit of this work. The author studied the ethanol-water separation using some salts: NaCl, CaCl2, Ca(NO3)2, CH3COOK, CH3COONa and a mixture of the latter two. Two different feeds were studied, 2 mole% and 0.25 mole% of ethanol. The water-acetic acid separation was also studied. For the Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). model, the predicted HETP obtained by Soares (2010) varied between 11.51 and 16.27 cm, the average predicted value being 12.83 cm. The minimum RD was 0.84% (water-acetic acid system) and the maximum 67.40%. The higher RDs were observed for all feeds with higher ethanol content. The HETP values obtained in the present work were slightly lower when compared with the results obtained by Soares (2010).

The Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). correlation presents a safety factor of 2.23 to cover 95% of real cases; thus, the results in Table 5 are within this range.

The estimations for the HETP obtained by using the model of Bolles and Fair (1982)Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982). are shown in Table 6. This correlation provided HETP values greater than those obtained from Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). and, as a consequence, the deviations from the pseudo-experimental values were smaller.

Table 6
HETP predicted from Bolles and Fair (1982).

Since the correlation of Bolles and Fair (1982)Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982). was not developed based on effective interfacial area, it has a strong dependence on liquid and vapor flow rates. Lower predicted values for HETP are related to higher flow rates, particularly the liquid flow rate, because the contribution of the height of the liquid phase in the mass transfer unit was higher than the vapor phase. This is in agreement with the expected result, because when the flow rate increases, it improves surface wettability and the effectiveness of the mass transfer.

Deviations obtained from the model proposed by Bolles e Fair (1982)Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982). usually did not exceed 30%. In this context, it is important to remember that the safety factor for this correlation is 1.7; thus, due to the low deviations observed, a small safety factor can be applied for this system. According to the authors, this strategy is used to determine HETP and it depends on the designer's experience.

The results in Table 6 are lower than those obtained by Soares (2010), that varied between 18.29 cm and 22.30 cm, the lowest deviation being 0.38% and the maximum 80.83%. The higher RDs obtained by the author for the Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). and Bolles and Fair (1982)Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982). correlations can be explained by the method to determine the number of theoretical stages, which was McCabe-Thiele (Henley and Seader, 1981Henley, E. J., Seader, J. D.,Equilibrium-Stage Separation Operations in Chemical Engineering. John Wiley & Sons, New York(1981).). For the feeds with 25 mole% of ethanol, this method gave as result N=1, causing high deviations.

HETP predictions were also carried out using the Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982). correlation. In this approach, two different equations were used to determine the mass transfer coefficients: Shulman et al. (1955)Shulman, H. J., Ullrich, C. F., Proulx, A. Z., Zimmerman, J. O.,Performance of packedcolumns. II. Wetted and effective-interfacial areas, gas-and liquid phase mass transfer rates. AIChE Journal, 1(2), p. 253-258(1955). the Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968).. The results are shown in Tables 7 and 8, respectively.

Table 7
HETP results obtained from Bravo and Fair (1982), using the Shulman et al. (1955) equations to obtain KV and KL.
Table 8
HETP results obtained from Bravo and Fair (1982), using the Onda et al. (1968) equations to obtain KV and KL.

Table 7 shows that the Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982). correlation using the Shulman et al. (1955)Shulman, H. J., Ullrich, C. F., Proulx, A. Z., Zimmerman, J. O.,Performance of packedcolumns. II. Wetted and effective-interfacial areas, gas-and liquid phase mass transfer rates. AIChE Journal, 1(2), p. 253-258(1955). equations for computing the mass transfer coefficients provided HETP values lower than those obtained by using the Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). equations, with deviations ranging from 7.6 to 47.49%. These results are related to the higher values of the mass transfer coefficients obtained by this approach, particularly KV, despite the small effective interfacial area, causing a reduction in HETP values. The safety factor proposed by Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982). is 1.6 and, if it is applied, deviations will be even smaller. For this model, Soares (2010) obtained HETP predicted values higher than the pseudo-experimental ones, with the predictions varying from 38.74 to 70.07 cm. The RD varied from 4.71% to 468%.

Table 8 shows that the Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982). correlation coupled with the Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). equations for computing the mass transfer coefficients provided high deviations, all over 100%. The predicted values were higher than those obtained by the pseudo-experimental approach, and varied from 37.57 to 40.09 cm. This correlation led to the highest HETP values obtained in this study. Using the Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). model, Soares (2010) also obtained HETP predicted values higher than pseudo-experimental, between 45.99 and 64.89 cm. Due to this, the RD obtained by the author varied from 32.42% to 426.1%.

Comparing the correlations proposed by Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). and Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982)., it is clear that the latter one led to small effective interfacial areas, providing the highest HETP values. Despite the explicit dependence on surface tension to estimate effective interfacial mass transfer area, the largest areas are not related to lower surface tension. Thus, for the Bravo and Fair (1982) correlation, hydrodynamic factors overcome the influence on HETP of the surface tension.

Comparing the results shown in Tables 7 and 8, the high dependence of the Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982). correlation on the mass transfer coefficients can be noted. These results show that the Shulman et al. (1955)Shulman, H. J., Ullrich, C. F., Proulx, A. Z., Zimmerman, J. O.,Performance of packedcolumns. II. Wetted and effective-interfacial areas, gas-and liquid phase mass transfer rates. AIChE Journal, 1(2), p. 253-258(1955). equations provided higher mass transfer coefficients in order to compensate the small effective interfacial area, leading to better estimations for HETP values. Table 9 shows a comparison of all correlations studied.

Table 9
Comparison between the correlations stud­ied in this work.

For a given correlation, the predicted HETP valueswere close to each other because of the proximity of the physical properties calculated for all systems, in accordance with Kister (1992)Kister, H. Z.Distillation design, McGraw-Hill, New York(1992).. Table 9 also shows that the Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982). correlation using the Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). equations overpredicted HETP values. The Onda et al. (1968) correlation and Bravo and Fair (1982) in conjunction with the Shulman et al. (1955)Shulman, H. J., Ullrich, C. F., Proulx, A. Z., Zimmerman, J. O.,Performance of packedcolumns. II. Wetted and effective-interfacial areas, gas-and liquid phase mass transfer rates. AIChE Journal, 1(2), p. 253-258(1955). equations provided similar results, despite the smaller interfacial area obtained from the Bravo and Fair (1982) model. As pointed out previously, mass transfer coefficients were higher from the Shulman et al. (1955) equation and the deviations for these two correlations are within the range of safety factors proposed by each work.

Caldas and Lacerda (1988)Caldas, J. N., Lacerda, A. I., Torres Recheadas. JR Editora Técnica Ltda., Rio de Janeiro (1988). (In Portuguese). reported that the Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982). model provides better results than the Bolles and Fair (1982)Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982). correlation for distillation cases, because the latter was not developed especially for this purpose. However, this was not observed, since Bolles and Fair (1982)Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982). led to the lowest deviations obtained in this work.

The results obtained in this work showed that the Bolles and Fair (1982)Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982). correlation could be used for the scale-up procedure of small diameter packed columns, since a safety factor of 1.3 can be successfully applied for this model. Moreover, according to Eckert (1970)Eckert, J. S., Selecting the proper distillation column packing. Chemical Engineering Progress, 66(3), p. 39-44(1970)., most of the designs for packed columns are made by using safety factors ranging from 10 to 35%.

CONCLUSIONS

The experimental results showed that glycerol is effective to dehydrate ethanol. Despite some limitations of the experimental unit, the azeotrope was not observed when S/F=0.9 was applied. It was observed that the products obtained are free of glycerol. Comparing the correlations used for HETP estimation, the Bolles and Fair (1982)Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982). model provided the best results. The Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982). correlation produced moderate values for the interfacial area, while the equations proposed by Shulman et al. (1955)Shulman, H. J., Ullrich, C. F., Proulx, A. Z., Zimmerman, J. O.,Performance of packedcolumns. II. Wetted and effective-interfacial areas, gas-and liquid phase mass transfer rates. AIChE Journal, 1(2), p. 253-258(1955). gave mass transfer coefficients higher than that obtained from the Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). equations. The deviations are in the same range of the safety factor proposed by each author, except for the Bravo and Fair (1982)Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982). model with the Onda et al. (1968)Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968). equations. The Bolles and Fair (1982)Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982). model is a good tool for the design of a packed bed for ethanol anhydrous production. If the unit to be revamped allows the entrainer flow in the packed section, more studies have to be conducted in order to determine the glycerol effect on HETP estimation.

To obtain ethanol anhydrous without any modification of experimental apparatus, an alternative would be to employ a series of columns similar to that used in this work. This proposal may be applied, for example, in a small distillery, since randomly packed columns are cheaper than plate ones.

NOMENCLATURE

ae Specific effective interfacial area (cm2/cm3) ap Specific area of packing (cm2/cm3) aw Specific wetted interfacial area (cm2/cm3) CaL Capillary number for the liquid CfL Coefficient for effect of approach of flood point on liquid phase mass transfer dp Diameter (or nominal size) of packing (cm) D Diffusion coefficients (cm2/s) f1 Correction factor viscosity f2 Correction factor specific mass f3 Correction factor surface tension Fr Froude number g Acceleration of gravity (cm/s2) gc force/mass conversion factor (g.cm/N.s2) G Superficial mass velocity (g/cm2.s) HETP Height Equivalent to Theoretical Plate (cm) HOV Height of a global mass transfer transfer unit (cm) H Height of a transfer unit (cm) kL Mass transfer coefficient of the liquid phase (cm/s) kv Mass transfer coefficient of the vapor phase (gmol/atm.cm2.s) M Molecular weight of the vapor (g/gmol) N Number of theoretical plates (stages) P Absolute pressure (atm) R Universal gas constant (atm.cm3/gmol.K) Re Reynolds number Sc Schmidt number T Temperature (K) We Weber number Z Height of the packed bed (cm) Greek Symbols ε Fraction void in packing λ Ratio of slopes of equilibrium to operation lines µ Viscosity (g/cm.s) ρ Specific mass (g/cm3) ρVM Molar specific mass of the vapor (mole/cm3) σ Surface tension (dyn/cm or g/cm2) σc Critical surface tension (dyn/cm) Φ Packing parameter for liquid phase mass transfer ψ Packing parameter for vapor phase mass transfer Subscripts L Liquid V Vapor w Water
  • *
    To whom correspondence should be addressed

REFERENCES

  • Bolles, W. L., Fair, J. R., Improved mass-transfer model enhances packed column design. Chemical Engineering, 89(14), p. 109-116(1982).
  • Bravo, J. L., Fair, J. R., Generalized correlation for mass transfer in packed distillation. Industrial & Engineering Chemistry Process Design and Development, 21(1), p. 162-170(1982).
  • Caldas, J. N., Lacerda, A. I., Torres Recheadas. JR Editora Técnica Ltda., Rio de Janeiro (1988). (In Portuguese).
  • Cornell, D., Knapp, W. G., Fair, J. R., Mass transfer efficiency packed columns part 1. Chemical Engineering Progress, 56(7), p. 68-74(1960).
  • DECHEMA, Vapor-Liquid Equilibrium Data Collection, Aqueous-Organic Systems (Supplement 1), v. I, Part 1a. Gmehling, V. J.,Onken, U.,Arlt, W. Frankfurt/M. (1981).
  • Eckert, J. S., Selecting the proper distillation column packing. Chemical Engineering Progress, 66(3), p. 39-44(1970).
  • Furter, W. F.,Extractive distillation by salt effect. Extractive and azeotropic distillation. Advances in Chemistry Series, 115, American Chemical Society, Washington, DC(1974).
  • Gil, I. D., Uyazán, A. M., Aguilar, J. L., Rodríguez, G., Caicedo, L. A., Separation of ethanol and waterby extractive distillation with salt and solvent as entrainer: Process simulation. Brazilian Journal of Chemical Engineering, 25(1), p. 207-215 (2008).
  • Henley, E. J., Seader, J. D.,Equilibrium-Stage Separation Operations in Chemical Engineering. John Wiley & Sons, New York(1981).
  • Kister, H. Z.Distillation design, McGraw-Hill, New York(1992).
  • Lee, F. M., Pahl, R. H.,Solvent screening study and conceptual extractive distillation process to produce anhydrous ethanol from fermentation broth. Ind. Eng. Chem. Process Des. Dev., 24, p. 168-172(1985).
  • Onda, K., Takeuchi, H., Okumoto, Y., Mass transfer coefficients between gas and liquid phases in packed columns. Journal of Chemical Engineering of Japan, 1(1), p. 56-62(1968).
  • Perry, R. H., Chilton, C. H.,Manual de Engenharia Química. 2ª Ed., Editora Guanabara Dois S.A.Rio de Janeiro(1980). (In Portuguese).
  • Prausnitz, J. M., Lichtenthaler, R. N., Azevedo, E. G., Termodinámica molecular de los equilibrios de fases. 3ª Ed., Prentice Hall Iberia, Madrid(2000). (In Spanish).
  • Ravagnani, M. A. S. S., Reis, M. H. M., Filho, R. M., Wolf-Maciel, M. R., Anhydrous ethanol production by extractive distillation: A solvent case study. Process Safety and Environmental Protection, 88, p. 67-73(2010).
  • Reid, R. C., Prausnitz, J. M., Poling, B. E.,The Properties of Gases and Liquids. 4th Ed., McGraw-Hill, Inc., New York(1987).
  • Shulman, H. J., Ullrich, C. F., Proulx, A. Z., Zimmerman, J. O.,Performance of packedcolumns. II. Wetted and effective-interfacial areas, gas-and liquid phase mass transfer rates. AIChE Journal, 1(2), p. 253-258(1955).
  • Uyazán, A. M., Gil, I. D., Aguilar, J. L., Rodríguez, G., Caicedo, L. A.,Producción de alcohol carburante por destilación extractiva: simulación del proceso con glycerol. Ingeniería e Investigación, 26(001), p. 45-50(2006). (In Spanish).

Publication Dates

  • Publication in this collection
    Apr-Jun 2016

History

  • Received
    29 May 2015
  • Accepted
    10 June 2015
Brazilian Society of Chemical Engineering Rua Líbero Badaró, 152 , 11. and., 01008-903 São Paulo SP Brazil, Tel.: +55 11 3107-8747, Fax.: +55 11 3104-4649, Fax: +55 11 3104-4649 - São Paulo - SP - Brazil
E-mail: rgiudici@usp.br