Acessibilidade / Reportar erro

A Simple and Effective Liquid-Liquid-Liquid Microextraction Method with Ultraviolet Spectrophotometric Detection for the Determination of Bisphenol A in Aqueous Matrices and Plastic Leachates

Abstract

This study shows the development and application of an analytical method for the determination of bisphenol A (BPA) in aqueous samples such as tap, river and mineral water and plastic leachates, based on an extensive literature search to understand the gaps for the determination of BPA in aqueous samples. We found that most of the methods in the literature employ some chromatographic strategy, and, to a much lesser extent, non-chromatographic instrumentation. In this scenario, we show an ultraviolet spectrophotometric-based method that can be used for routine analysis. Sample preparation was conducted by means of solvent extraction followed by back-extraction into an alkaline aqueous solution (liquid-liquid-liquid microextraction) and the detection was performed by UV spectrophotometry at 294 nm. Optimization of variables affecting both extraction and back-extraction was conducted, and the optimal extraction conditions were obtained: 85 mL aqueous sample buffered at pH 10, ionic strength adjusted with NaCl to a 2 mol L-1 final concentration, extraction with 6 mL of ethyl ether for 10 min and back-extraction into 0.5 mL of 2 mol L-1 aqueous NaOH. The following quality parameters were obtained: determination coefficient (R22 https://www.researchandmarkets.com/research/4xx8j9/bisphenola_a, accessed in March 2020.
https://www.researchandmarkets.com/resea...
) > 0.999, intra and inter-day repeatability better than 7.8% and 300 enhancement factor. The method was applied in different aqueous samples with excellent recovery and precision results, and no BPA was detected in natural water, even with the excellent limit of detection (3.5 μg L-1) and limit of quantification obtained. Limitations of this method involve analysis of samples with humic acid concentrations higher than 2 mg L-1 or high concentration of phenols and/or phthalate esters.

Keywords:
bisphenol A; spectrophotometry; liquid-liquid-liquid microextraction


Introduction

Contemporary productive society seeks constant productivity increase and profit maximization, which can use means with an exacerbated use of compounds and products capable of bringing risks to the health of living organisms, through contamination of water, air and soil. Compounds of different classes have been distributed at great speed in the environment, reaching the human being, animals and plants via different routes. The unrestrained presence and high amounts of plasticizers, personal care products, hormones, drugs, pesticides, nanoparticles and flame retardants have been extensively discussed and studied by several research groups worldwide,11 Sauvé, S.; Desrosiers, M.; Chem. Cent. J. 2014, 8, 15. given their known and potent deleterious effects to various organisms. The problem with the class of plasticizers, specifically, has been widely discussed, involving several compounds known to scientists, government and international media, which produce materials to alert the population about the toxicity of certain compounds. Among these compounds is bisphenol A (BPA).

BPA (2,2-bis(4-hydroxyphenyl propane)) is a diphenol applied in several matrices, processes and products. The industrial production of BPA is estimated to reach 10 million tons per year in 2022, being 8 million in 2016.22 https://www.researchandmarkets.com/research/4xx8j9/bisphenola_a, accessed in March 2020.
https://www.researchandmarkets.com/resea...
About 95% of BPA production is used in the polymer industry, including polycarbonate and epoxy resins.33 Flint, S.; Markle, T.; Thompson, S.; Wallace, E.; J. Environ. Manage. 2012, 104, 19. Thus, BPA is applied to several everyday products such as water bottles, electronic equipment, paper and toys.44 Michałowicz, J.; Environ. Toxicol. Pharmacol. 2014, 37, 738. BPA is considered an endocrine disrupter, particularly capable of binding and activating estrogen receptors, and its estrogenic properties have been recognized since 1938 by Dodds et al.55 Dodds, E. C.; Goldberg, L.; Lawson, W.; Robinson, R.; Nature 1938, 141, 247. This compound is considered a synthetic xenoestrogen and, when in contact with the human organism, it can deregulate the endocrine functions by mimetizing or blocking endogenous hormones.66 Schug, T. T.; Janesick, A.; Blumberg, B.; Heindel, J. J.; J. Steroid Biochem. Mol. Biol. 2011, 127, 204.

Since water is a widely available matrix that can be the final destination of domestic and industrial waste, we must develop effective analytical methods for the monitoring of natural waters such as rivers, lakes and seas, as well as treated water samples, to verify the potential toxicity to which organisms are exposed. This statement gets clearer after searching the literature for methods for the determination of BPA in aqueous samples in the last 20 years (1999-2018), considering chromatographic and spectrometric methods. In total, 148 methods were found, and this number is increasing over the years (Figure S1 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. , Supplementary Information (SI) section). In terms of sample preparation methods, we verified that about 70% of the studied methods are based on the retention of BPA by a solid phase (Figure S2 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. , SI section), in which solid-phase extraction (SPE) corresponds to half of the analyzed methods, including new approaches with molecularly printed polymers and magnetic particles. Solid phase microextraction (SPME) and stir-bar sorptive extraction (SBSE) represent 13 and 6% of the total, respectively. On the other hand, 97% of the total of the articles used chromatographic methods. Two-thirds of all methods use liquid chromatography (LC) and 25% gas chromatography (GC), followed by capillary electrophoresis (CE) and supercritical fluid chromatography (SFC). Only 3% of the methods used non-chromatographic detection alternatives, including fluorimetry, Raman spectrometry and UV-Vis spectrophotometry (Figure S3 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. , SI section).

Other information involving the method development such as quantity of samples, sample preparation time, time required for instrumental analysis, sample volume and analytical parameters of merit were also investigated and are shown in the SI section (Figures S4 to S8). The limit of detection (LOD) of methods for environmental analysis are low, commonly lesser than 10 µg L-1, as can be seen in the Figure S5 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. (SI section), since the concentration of pollutants are in this concentration range.

Regarding the study of potential interferents, even considering that most of the searched works use highly selective chromatographic methods, this observation is very important for an analytical method, since it makes method limitations clearer, allowing the analyst to decide if the method is reliable for a given sample. Interferents may cause either selectivity interference or matrix effects, especially in a complex environmental water sample. As shown in Figure S9 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. (SI section), 81% of the articles do not study the response of their methods in relation to the presence of interferents. Several authors77 Prieto, A.; Schrader, S.; Moeder, M.; J. Chromatogr. A 2010, 1217, 6002.

8 Liu, R.; Zhou, J. L.; Wilding, A.; J. Chromatogr. A 2004, 1022, 179.

9 Iparraguirre, A.; Prieto, A.; Navarro, P.; Olivares, M.; Fernández, L. Á.; Zuloaga, O.; Anal. Bioanal. Chem. 2011, 401, 339.
-1010 Guitart, C.; Readman, J. W.; Anal. Chim. Acta 2010, 658, 32. who study the presence of interferents are especially careful with the presence of humic acid, a component that may be present in environmental samples in the 0 to 10 mg L-1 range. Other studies1111 Xu, Z.; Wu, Q.; Duan, Y.; Yang, M.; Ou, M.; Xu, X.; J. Braz. Chem. Soc. 2017, 28, 1475.

12 Li, J.; Zhang, X.; Liu, Y.; Tong, H.; Xu, Y.; Liu, S.; Talanta 2013, 117, 281.
-1313 Chu, G.; Cai, W.; Shao, X.; Talanta 2015, 136, 29. evaluate the presence of other compounds in the sample, such as BPA analogs. We must note that all studies that evaluate interferents were conducted using a univariate approach. This means that they perform tests considering only the presence of one interferent at a time, not considering the possibility that they may all exist simultaneously in the sample, which is understood to be quite plausible in the case of natural water samples.

One can emphasize the small diversity of strategies that do not use chromatographic methods. However, the separation methods, although very relevant, usually present high cost of acquisition and maintenance when compared with spectrometric methods. Considering the UV-Vis spectrophotometry methods, all the searched articles1111 Xu, Z.; Wu, Q.; Duan, Y.; Yang, M.; Ou, M.; Xu, X.; J. Braz. Chem. Soc. 2017, 28, 1475.,1414 Xu, J.; Li, Y.; Bie, J.; Jiang, W.; Guo, J.; Luo, Y.; Shen, F.; Sun, C.; Microchim. Acta 2015, 182, 2131.,1515 Yıldırım, E.; Gürkan, R.; Altunay, N.; Food Anal. Methods 2017, 10, 1765. report the use of the visible region, displacing the wavelength of maximum absorption of BPA through different mechanisms. The paper by Xu et al.1414 Xu, J.; Li, Y.; Bie, J.; Jiang, W.; Guo, J.; Luo, Y.; Shen, F.; Sun, C.; Microchim. Acta 2015, 182, 2131. uses the interaction of BPA with gold nanoparticles coated with cysteamine, allowing the determination of BPA at 680 nm. Yıldırım et al.1515 Yıldırım, E.; Gürkan, R.; Altunay, N.; Food Anal. Methods 2017, 10, 1765. performed the preconcentration of BPA based on its complexation with colorimetric reagent (3-methylamino-7-dimethylaminophenothiazin-5-ium chloride in the presence of cetyltrimethylammonium bromide), by cloud point extraction, enabling its measurement at 643 nm. The last alternative method to determine BPA by spectrophotometry, developed by Xu et al.,1111 Xu, Z.; Wu, Q.; Duan, Y.; Yang, M.; Ou, M.; Xu, X.; J. Braz. Chem. Soc. 2017, 28, 1475. is based on the diazotization reaction of BPA with sulfamethoxazole, detecting a maximum absorbance at 445 nm. The limits of detection obtained by the authors in these methods were 0.11 μg L-1 for Xu et al.,1414 Xu, J.; Li, Y.; Bie, J.; Jiang, W.; Guo, J.; Luo, Y.; Shen, F.; Sun, C.; Microchim. Acta 2015, 182, 2131. 0.35 µg L-1 for Yildirin et al.1515 Yıldırım, E.; Gürkan, R.; Altunay, N.; Food Anal. Methods 2017, 10, 1765. and 50 μg L-1 for Xu et al.1111 Xu, Z.; Wu, Q.; Duan, Y.; Yang, M.; Ou, M.; Xu, X.; J. Braz. Chem. Soc. 2017, 28, 1475.

In this scenario, this study proposes the development of a novel low-cost analytical method for BPA determination in aqueous samples applying a very simple sample preparation procedure based on solvent extraction followed by a back-extraction of the analyte into an aqueous alkaline microvolume (liquid-liquid-liquid microextraction), and detection using an inexpensive and highly available UV-Vis spectrophotometer (LLLME-UV). Optimization of extraction and back-extraction variables were carried out, and a multivariate approach was performed for the first time to study the effect of the concomitant presence of humic acid, phenols and phthalate esters in two different BPA concentration levels. The main quality parameters were determined, and six samples were subjected to the proposed method. Samples containing the analyte were also subjected to gas chromatography-mass spectrometry (GC-MS) analysis to confirm analyte identity and concentration.

Experimental

Reagents and preparation of solutions

A BPA stock solution was prepared by weighing 100.0 mg of the pure solid (Sigma-Aldrich, Saint Louis, USA) and dissolved with high-performance liquid chromatography (HPLC)-grade ethanol (Tedia, Fairfield, USA) for a 10.00 mL final volume. The aqueous sample solutions were prepared with water obtained on a reverse osmosis system RQ Evolution RO 0410 (Permution, Curitiba, Brazil) with conductivity below 1.0 μS cm-1.

The Britton-Robinson buffer (BR buffer) was prepared from analytical grade glacial acetic acid, potassium dihydrogen phosphate and boric acid (Vetec, Rio de Janeiro, Brazil), each component at 0.4 mol L-1 final concentration. The required sample pH was adjusted by adding 6.0 mol L-1 solutions of hydrochloric acid (Neon Comercial, São Paulo, Brazil) and/or 6.0 mol L-1 sodium hydroxide (Biotec, Pinhais, Brazil) by using a pH meter (model pH 510 Basic, Oakton, USA). Sodium chloride (Biotec, Pinhais, Brazil) was used to adjust ionic strength of the samples. Organic solvents (acetone, ethyl ether, chloroform, hexane and toluene) used were all HPLC-grade purity (Tedia, Fairfield, USA).

A solution containing six phthalate esters was prepared from standard CRM48805 batch XA25890V from Sigma-Aldrich (Saint Louis, USA), diluted to 3.40 mg L-1 (total phthalate concentration) with ethanol. A solution containing eleven phenol mixture was prepared from standard (CRM 48866 batch LC12991V, Sigma-Aldrich, Saint Louis, USA) and diluted with ethanol to 1.70 mg L-1 as the final total phenol concentration. Humic acid solution at 1.00 g L-1 was prepared by diluting the pure compound (Sigma-Aldrich, Saint Louis, USA) in 0.01 mol L-1 NaOH.

When GC-MS was used, BPA contained in the ether extract obtained in the method (previous to back-extraction) was submitted to derivatization using pyridine and N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) containing 1% trimethylchlorosilane (TMSCl) obtained from Sigma-Aldrich (Saint Louis, USA). For the derivatization reaction, 170 µL of the ether extract was allowed to evaporate at room temperature. To the dried extract, 50 µL pyridine and 50 µL BSTFA were added into 2 mL screw capped vial, which was kept closed for 30 min. This solution was analyzed by GC-MS in the conditions given in “Instrumentation” sub-section.

Instrumentation

A UV-Vis spectrophotometer Spectroquant Pharo 300 (Merck, Darmstadt, Germany) was employed for all spectrophotometric analyses. It is equipped with a simple beam system and a xenon lamp; the working range is 190 and 900 nm with a 1 nm resolution.

The verification of the selectivity of the proposed method was conducted using a GCMS-QP2010 Ultra (Shimadzu, Kyoto, Japan) gas chromatograph coupled to mass spectrometer, operating with ultra-pure helium gas as mobile phase, AOC-20i automatic sampler (whose operating characteristics are shown in Table S2 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. , SI section) and split-splitless injector. As a stationary phase, the HP-5ms column (Agilent Technologies, Santa Clara, USA), 30 m long, 0.25 mm internal diameter and 0.25 μm stationary phase was used, which was composed of 95% dimethyl/5% diphenyl polysiloxane. The quadrupole mass analyzer used has a unitary mass resolution. Data acquisition by the instrument was performed in the full mass scanning mode, in the m/z 40-400 range. The temperatures used were: injection, interface and source of ions, respectively, 300, 280, and 200 ºC; oven temperature programming: 60 ºC for 0.5 min, heating to 300 ºC at 45 ºC min-1, remaining at 300 ºC for 1.17 min, totaling a 7 min run. The mobile phase flow (99.999% pure helium) was 1.70 mL min-1, except for the first minute, in which the flow rate was 3.6 mL min-1, corresponding to a 200 kPa pressure. The injection was performed in splitless mode for 1 min, followed by a 1:5 split ratio for the rest of the run.

Sample preparation procedure

Sample preparation consisted of 85 mL of sample added in a 100 mL glass volumetric flask. The ionic strength and sample pH are adjusted to the desired value using solid NaCl and 5 mL of 0.4 mol L-1 BR buffer previously adjusted to the desired pH, respectively. The final volume of the conditioned sample is approximately 100 mL. Then, 6 mL of organic solvent for extraction are added in the same flask, which occurs for 10 min under vigorous magnetic stirring. The organic extract separates rapidly, being removed from the flask (with a little of the aqueous phase) with a glass Pasteur pipette and transferred into a 15 mL polypropylene centrifuge tube, which is centrifuged for 2 min at 4000 rpm. Subsequently, the entire organic phase (approximately 2.5 mL) is carefully collected and 500 μL of aqueous NaOH solution is added in another 15 mL polypropylene centrifuge tube.

The back-extraction is conducted in this flask with manual stirring (approximately 3 min). Phase separation is accelerated by centrifugation for 2 min at 4000 rpm. The organic phase is discarded and the aqueous 2 mol L-1 NaOH phase is taken to the quartz cuvette (1.0 cm optical path, 0.7 mL total volume) for measurement in the spectrophotometer. The absorption spectra between 230 and 320 nm is then recorded. Figure 1 shows a typical spectrum. As the reference (100% transmittance), 2 mol L-1 NaOH solution saturated with ethyl ether is used, simulating the properties of the aqueous fraction obtained in the back-extraction. The BPA spectrum in alkaline solution has two major bands, the first centered at 242 nm and the second at 294 nm, which is used for quantitative measurements due to its higher selectivity.

Figure 1
Spectrum in the UV region of BPA in 2 mol L-1 NaOH.

Procedure optimization

The extraction procedure was optimized for the variables affecting its performance. The optimization was systematically performed, seeking the best condition for the extraction method, and multivariately, to study the selectivity and a possible interaction between the variables.

Sensitivity optimization

The parameters studied in the univariate optimization were: NaOH concentration for back-extraction, extraction solvent, ionic strength, sample pH, extraction time and solvent volume. Absolute recovery in each step of optimization was estimated based on the instrumental calibration curve built in aqueous 2 mol L-1 NaOH.

To verify the optimal NaOH concentration for back-extraction, a 10 mg L-1 BPA solution was prepared in ethyl ether, simulating the organic extract obtained from the extraction. NaOH concentration ranged from 0.0024 to 3.17 mol L-1. For the optimization of the extraction solvent, tests were conducted following the previously described methodology, changing only the extraction solvent. Ethyl ether, chloroform, toluene and hexane were tested. The optimization of the sample ionic strength was conducted using ethyl ether as extraction solvent. Salting-out effect was evaluated by using NaCl concentration equivalent to a 0.3-5.0 mol per liter of sample range. The sample pH ranged from 1 to 13, using BR buffer at 0.05 mol L-1 final concentration. To optimize extraction time, tests were performed changing only the magnetic stirring time of the sample, between 0.25 and 20 min. Solvent volume optimization was performed in the range between 4-6 mL of ethyl ether. Back-extraction volume was fixed at 500 µL based on the minimal volume in the cuvette necessary for instrumental measurement.

Multivariate evaluation of selectivity

To optimize the selectivity of the method for the presence of interferents, a multivariate optimization was developed to minimize the coextraction of interferents, and/or to check the maximum concentration level of the interferents that may be present in the sample, not deteriorating method trueness. Based on the possible presence of interferents of several classes simultaneously in the sample, the multivariate optimization proves adequate and essential to verify the method’s robustness. The main interferents were humic acid, phthalate esters and phenols, since they can be commonly found in natural water samples.1616 Amiridou, D.; Voutsa, D.; J. Hazard. Mater. 2011, 185, 281.

17 Gatselou, V. A.; Giokas, D. L.; Vlessidis, A. G.; Anal. Chim. Acta 2014, 812, 121.

18 Sánchez-Avila, J.; Tauler, R.; Lacorte, S.; Environ. Int. 2012, 46, 50.
-1919 Zaki, G.; Shoeib, T.; Sci. Total Environ. 2018, 618, 142. For this study, a two-level fractional factorial design was performed, and five factors were studied: BPA concentration, sample pH, humic acid concentration, total phthalates and total phenols.

The choice of the BPA concentration as a factor in the design was evaluated to verify the method trueness in a wide linear range, not only in a fixed high concentration, as is usually done. The minimum limit was defined as 30 μg L-1, and the maximum as 350 μg L-1 (center point at 190 μg L-1). The pH range studied was from 9 to 11, as this is the range in which there is a decrease in the sensitivity for BPA extraction, but it may be a range in which coextraction can be minimized, especially of other phenols. The studied humic acid concentration was ranged from 0 to 10 mg L-1, the latter being the near-maximum value naturally found in natural waters, as shown in Table S3 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. (SI section) by several authors. Nevertheless, for the final experimental design, the level of humic acid ranged from 0 to 2 mg L-1, since in preliminary tests, samples with concentrations greater than 2 mg L-1 of humic acid increased significantly in recovery due to co-extraction, deteriorating recovery significantly, especially at the lowest BPA concentration. The concentration levels of phenols and phthalates were defined based on the mean of the sum of the analytes of each class in water samples (0.4 and 0.8 μg L-1, respectively) found in several articles in the literature (Tables S4 and S5, SI section). This average was used as the center point, with the maximum value of each factor being twice this average. Thus, the maximum values of phenols and phthalates, are, respectively, 0.8 and 1.6 μg L-1. Table S6 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. (SI section) shows the combination of levels for each variable, as given by the Statistica 7 software.2020 Statistica, 7.0; StatSoft, Inc., Tulsa, OK, USA, 2004. Recovery was used as the response, being calculated by comparing the absorbance measured in each experiment with the calibration curve performed with the extraction method at each pH evaluated in the design.

Evaluation of the main parameters of merit

With the optimized conditions, the main quality parameters were estimated: sensitivity, intercept, correlation coefficient and the limits of detection (LOD) and quantification (LOQ). LOD and LOQ were estimated as three and ten times the standard deviation of the intercept divided by the slope, respectively. Experiments were also performed with environmental samples to verify the precision (inter- and intra-day repeatability) and trueness (recovery tests). The upper concentration range was 700 μg L-1 for the LLLME-UV method and for the LLME-GC-MS method (without back-extraction) was 120 μg L-1.

UV spectrophotometer calibration was also carried out, without extraction procedure, with direct reading of BPA solutions in 2 mol L-1 NaOH at different concentrations in the 5 to 122 mg L-1 range. The purpose of this calibration was to obtain sensitivity and instrumental LODs to verify the enrichment and improvement factors of the proposed method. The enrichment factor was calculated by the ratio between the slopes of the extraction method and the instrumental sensitivity, and the enhancement factor was calculated by the ratio between the instrumental and the proposed method limits of detection.

Applications of the LLLME-UV method

Water samples

A river water sample was collected from Rio Comprido (Joinville, Santa Catarina, Brazil) and artesian well water sample was obtained as a courtesy of a property in the rural area of the same city.

Samples of tap water and mineral water were collected at the university campus. Sample of lake water was collected on the same place and filtered on qualitative paper. All samples were collected and stored in a polypropylene vial filled with zero headspace and kept in a refrigerator (4 ºC) until analysis.

Lake water fortified with humic acid in different concentrations, from 2.5 to 10.0 mg L-1, was used for selectivity studies and verification of limitations of the method, simulating environmental samples rich in organic matter.

Lixiviation studies

A leaching test on a plastic bottle sample (Leached I) made of polycarbonate, purchased in the local market, was performed with water extraction using a domestic microwave (Electrolux, model MEF28, power of 1150 W). The experiment followed guidelines found in the literature.2121 Biedermann-Brem, S.; Grob, K.; Eur. Food Res. Technol. 2009, 228, 679. Shortly, the bottle was filled with reverse osmosis water (400 mL) and heated in a microwave for 10 min. The aqueous extract was separated and applied in the developed method.

This first test sought to verify the possibility of applying the developed method to verify the maximum permitted limit of BPA leaching in packaging and equipment for foodstuff, regulated by Brazilian legislation (Resolution No. 17, March 17, 2008, of the Ministry of Health and the National Health Surveillance Agency (ANVISA))2222 Agência Nacional de Vigilância Sanitária (ANVISA); Resolução No. 17, de 17 de Março de 2008; Dispõe sobre Regulamento Técnico sobre Lista Positiva de Aditivos para Materiais Plásticos Destinados à Elaboração de Embalagens e Equipamentos em Contato com Alimentos; ANVISA: Brasília, 2008. Available at bvsms.saude.gov.br/bvs/saudelegis/anvisa/2008/res0017_17_03_2008.html, accessed in March 2020.
bvsms.saude.gov.br/bvs/saudelegis/anvisa...
and internationally (Commission Regulation No. 10/2011 of 14 January 2011 of the European Union).2323 European Commission; Commission Regulation (EU) No. 10/2011 of 14 January 2011 on Plastic Materials and Articles Intended to Come into Contact with Food; Official Journal of the European Union: Brussels, 2011. Available at https://eur-lex.europa.eu/legal-content/EN/ALL/?uri=CELEX%3A32011R0010, accessed in March 2020.
https://eur-lex.europa.eu/legal-content/...
These standards limit the BPA leaching to 0.6 mg per kg of food. Working exclusively with pure water as a food simulant, the limits correspond to the 600 μg L-1 BPA concentration.

Sample labeled as Leached II was based on a polycarbonate (PC) sample used in civil construction as roofing tiles, also following an adapted literature experiment.2424 D’Antuono, A.; Dall’Orto, V. C.; Lo Balbo, A.; Sobral, S.; Rezzano, I.; J. Agric. Food Chem. 2001, 49, 1098. The sample was segmented into small pieces (approximately 2 × 2 cm), and an 85 g mass was immersed in 850 mL of reverse osmosis water and heated at 80 ºC for 4 h (evaporated water was replaced). The solids (PC sample) were removed by decantation and the aqueous fraction collected and subjected to the developed method.

Results and Discussion

Optimization of extraction and back-extraction variables

Concentration of NaOH for re-extraction

The back-extraction procedure was optimized by changing NaOH concentration. According to Figure 2a, at low NaOH concentrations, the back-extraction is not favored, and the migration does not occur quantitatively. The electrically neutral BPA must react with hydroxide to form the doubly electrically charged bisphenol (bisphenolate), much more soluble in water than in the solvent. Working with NaOH concentrations ranging from 0.0024 to 3.17 mol L-1 (theoretical pH from 11.4 to 14.5), a concentration greater than 0.04 mol L-1 (pH > 12.5) for a quantitative re-extraction was required, with a robustness up to the upper working range. As seen in Figure S10 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. (species distribution chart, SI section), above pH 12, BPA is present in a higher percentage as the doubly deprotonated form, confirming the results obtained. As an optimum value for the work, we chose to work in NaOH concentration 2 mol L-1 equivalents to a theoretical 14.3 pH, due to the higher phase separation velocity at this high ionic strength, which makes the method faster.

Figure 2
Optimization of the main variables affecting the proposed LLLME-UV method. (a) Concentration of NaOH for re-extraction; (b) extraction solvents; (c) ionic strength; (d) extraction pH; (e) extraction time; (f) solvent volume.

Extraction solvent

Figure 2b shows the effect of different extraction solvents on BPA recovery from water samples. Among the extractive solvents evaluated, hexane (the most nonpolar alternative) recovered less than 50%. For the remaining options, the best alternatives are the use of diethyl ether and chloroform, with recoveries greater than 90%. The use of chloroform, however, is more difficult to work with due to its high density when compared to the aqueous phase, since it is necessary to collect the solvent in the bottom of the extraction flask (100 mL volumetric flask). Thus, we decided to use diethyl ether due to its lower density when compared to the aqueous solution and lower toxicity when compared to chloroform.

Ionic strength

The evaluation of the ionic strength (Figure 2c) allows to find a condition of wide range of ionic strength (from 1 to 5 mol L-1) in which the extraction is quantitative. At very low ionic strengths, the effect of decreasing the solubility of BPA in water (salting-out effect) may not be enough to allow the extraction of aqueous BPA to the organic solvent. We attribute the best condition of ionic strength as 2 mol L-1 NaCl, since this concentration leads to a fast phase separation and high BPA recovery.

Extraction pH

As already described, BPA has different abundances in its neutral form as the sample pH changes (Figure S10 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. , SI section). Thus, the effect of the sample pH on its extraction efficiency was verified (Figure 2d). Extractions performed with a sample with pH lower than 9 are not statistically different. Under these conditions, BPA is totally in its electrically neutral form, favoring its extraction by the organic solvent. We attributed pH 9 to the optimized condition. Nevertheless, the use of pH 10 and 11 may be applicable, but there will be a slight loss in sensitivity.

Extraction time

The extraction time was also optimized, since an analytical method should be as fast and practical as possible (Figure 2e). Extraction times greater than 3 min were found to be enough to establish the BPA partition equilibrium between the aqueous and organic phases, and that after this time the recovery of the analyte is statistically the same. We decided to choose the time of 10 min for effective extraction, since the extraction conditions depend on the degree of stirring on the flask used and the magnetic stirrer power, ensuring that the equilibrium can be achieved even with small variations in the effectiveness of stirring.

Solvent volume

The solvent volume used was also studied to minimize its use (Figure 2f). We noticed that there is no significant variation of the extraction efficiency with the variation of the volume of solvent used in the 4 to 6 mL range, recoveries ranging from 90 to 105%. The volume chosen as the optimum one was 6 mL, since the separation phase is adequately fast with this volume and recovery is maximized. Working with a lower volume of extraction solvent is also possible, improving method enrichment factor when no back-extraction is used, i.e., when the organic phase is directly analyzed by other instrumentation such as GC. It should be emphasized that direct measurement of ether extracts by UV at 294 nm was not possible due to high absorbance value of such solvent at this wavelength.

Selectivity multivariate analysis

Figure 3 shows recovery results in the lowest BPA condition, 30 and 350 μg L-1 BPA and pH 10, at the center point of concentration of the interferents.

Figure 3
Response profile predicted by the experimental design: BPA (a-c) 30 and (d-f) 350 μg L-1, pH 10, 1 mg L-1 for humic acid, 0.4 μg L-1 for total phenols and 0.8 μg L-1 for phthalates; and their relationship with the maximum allowed recovery (dashed red line).

In the first condition, the concentration of humic acid ranging from 0 to 2 mg L-1 does not affect the selectivity of the method, whose recovery ranges from 110 to 115% throughout the range. Such behavior is not observed for phenols and phthalates: high concentrations of these interferents raises the recovery results, indicating loss of selectivity with the overestimated measurement of absorbance (however, for a high concentration of BPA, interferents are not significant). This fact can be understood because of the structural similarity with BPA: phenols tend to be co-extracted by the method, also considering that they have a significant molar absorptivity at 294 nm, as can be observed in Figure S11 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. (SI section).

Nonetheless, the presence of studied interferents at their natural average concentration in aqueous environmental samples allows acceptable recovery.2525 Rambla-Alegre, M.; Esteve-Romero, J.; Carda-Broch, S.; J. Chromatogr. A 2012, 1232, 101. That is, the method can be sufficiently accurate at 30 μg L-1 or higher even with the simultaneous influence of different contaminants (humic acid, phenols and phthalates).

Then, based on both the univariate optimization experiments and the multivariate study, the optimal sample preparation condition is described: for 85 mL of sample, adjusted at pH 10 with 5 mL of 0.4 mol L-1 BR buffer and ionic strength 2 mol L-1 with NaCl, the extraction is performed with 6 mL of diethyl ether for 10 min under magnetic stirring, followed by back-extraction of the entire organic extract with 0.5 mL of 2 mol L-1 NaOH. The maximum concentrations tolerated by the method are 2 mg L-1 of humic acid, 0.4 μg L-1 of phenols and 0.8 μg L-1 of phthalates, either individually or concomitantly.

Evaluation of the main parameters of merit

The main quality parameters of the LLLME-UV method are described in Table 1. Instrumental calibration was also performed for comparison.

Table 1
Evaluation of the main quality parameters of both instrument (without extraction) and the LLLME-UV proposed method

The improvement factor is 300, i.e., the application of the method reduces the minimum detectable concentration by 300 times. The enrichment factor of the method is 155. This value approaches the expected maximum factor of 170 (considering a 85 to 0.5 mL phase ratio, between sample and final aqueous phase), indicating that most of the BPA present in the sample is actually extracted, confirming the improvement of sensitivity by the application of the method. The ratio between the obtained and the expected maximum results in 91%, indicating a very high absolute recovery. For the calibration of the method, especially, satisfactory parameters were obtained, such as the limit of detection in the μg L-1 range (Table 1) and excellent correlation coefficient. The merit parameters presented excellent values, both in terms of accuracy and precision, as well as the limit of detection and linear range, in line with ANVISA2222 Agência Nacional de Vigilância Sanitária (ANVISA); Resolução No. 17, de 17 de Março de 2008; Dispõe sobre Regulamento Técnico sobre Lista Positiva de Aditivos para Materiais Plásticos Destinados à Elaboração de Embalagens e Equipamentos em Contato com Alimentos; ANVISA: Brasília, 2008. Available at bvsms.saude.gov.br/bvs/saudelegis/anvisa/2008/res0017_17_03_2008.html, accessed in March 2020.
bvsms.saude.gov.br/bvs/saudelegis/anvisa...
and European Union2323 European Commission; Commission Regulation (EU) No. 10/2011 of 14 January 2011 on Plastic Materials and Articles Intended to Come into Contact with Food; Official Journal of the European Union: Brussels, 2011. Available at https://eur-lex.europa.eu/legal-content/EN/ALL/?uri=CELEX%3A32011R0010, accessed in March 2020.
https://eur-lex.europa.eu/legal-content/...
resolutions regarding BPA leaching for food (specifically for water).

The method presented excellent intra-day precision (Table 2), analyzed in five different levels by the relative standard deviation (RSD). Inter-day precision also showed excellent results, especially when compared with the maximum acceptable RSD intra-lab, given by Horwitz.2626 Horwitz, W.; Anal. Chem. 1982, 54, 67.

Table 2
Evaluation of LLLME-UV repeatability and intermediate precision and their comparison with the acceptable limit2626 Horwitz, W.; Anal. Chem. 1982, 54, 67.

All precision tests fit within the maximum limits set by the AOAC,2727 AOAC Official Methods of Analysis; Appendix F: Guidelines for Standard Method Performance Requirements; AOAC International: Gaithersburg, MD, 2016. Available at http://www.eoma.aoac.org/app_f.pdf, accessed in March 2020.
http://www.eoma.aoac.org/app_f.pdf...
indicating the quality of the method.

Method application

The method was applied to different samples, and a summary of the results is shown in Table 3.

Table 3
Summary of LLLME-UV method applications, recovery and precision assays

BPA concentration was below the limits of the detection method in the first five samples. Recovery and repeatability tests for these samples are in accordance with the expected results.2525 Rambla-Alegre, M.; Esteve-Romero, J.; Carda-Broch, S.; J. Chromatogr. A 2012, 1232, 101.

26 Horwitz, W.; Anal. Chem. 1982, 54, 67.
-2727 AOAC Official Methods of Analysis; Appendix F: Guidelines for Standard Method Performance Requirements; AOAC International: Gaithersburg, MD, 2016. Available at http://www.eoma.aoac.org/app_f.pdf, accessed in March 2020.
http://www.eoma.aoac.org/app_f.pdf...
The recovery range varied between 98.9 and 113.0% among the three concentration levels studied and repeatability from 1.5 to 10.3%.

Microwave plastic cup leaching test (Leached I) did not result in detectable presence of BPA in the aqueous sample. Precision and recovery tests have been successfully performed. Thus, this method can be used to evaluate the migration of BPA from plastic packaging following the regulations of the Brazilian Ministry of Health,2222 Agência Nacional de Vigilância Sanitária (ANVISA); Resolução No. 17, de 17 de Março de 2008; Dispõe sobre Regulamento Técnico sobre Lista Positiva de Aditivos para Materiais Plásticos Destinados à Elaboração de Embalagens e Equipamentos em Contato com Alimentos; ANVISA: Brasília, 2008. Available at bvsms.saude.gov.br/bvs/saudelegis/anvisa/2008/res0017_17_03_2008.html, accessed in March 2020.
bvsms.saude.gov.br/bvs/saudelegis/anvisa...
as well as the European Union2323 European Commission; Commission Regulation (EU) No. 10/2011 of 14 January 2011 on Plastic Materials and Articles Intended to Come into Contact with Food; Official Journal of the European Union: Brussels, 2011. Available at https://eur-lex.europa.eu/legal-content/EN/ALL/?uri=CELEX%3A32011R0010, accessed in March 2020.
https://eur-lex.europa.eu/legal-content/...
resolution. The application of the method is essential for this case, since the direct measurement of the leach sample by the instrument does not reach the limit of detection required by both Brazilian and EU regulations (Table 1).2222 Agência Nacional de Vigilância Sanitária (ANVISA); Resolução No. 17, de 17 de Março de 2008; Dispõe sobre Regulamento Técnico sobre Lista Positiva de Aditivos para Materiais Plásticos Destinados à Elaboração de Embalagens e Equipamentos em Contato com Alimentos; ANVISA: Brasília, 2008. Available at bvsms.saude.gov.br/bvs/saudelegis/anvisa/2008/res0017_17_03_2008.html, accessed in March 2020.
bvsms.saude.gov.br/bvs/saudelegis/anvisa...
,2323 European Commission; Commission Regulation (EU) No. 10/2011 of 14 January 2011 on Plastic Materials and Articles Intended to Come into Contact with Food; Official Journal of the European Union: Brussels, 2011. Available at https://eur-lex.europa.eu/legal-content/EN/ALL/?uri=CELEX%3A32011R0010, accessed in March 2020.
https://eur-lex.europa.eu/legal-content/...

For the sample labeled as Leached II, 45.0 μg L-1 BPA was determined by LLLME-UV method. In contrast, the experiment performed by GC-MS showed a divergent result, namely, 28.4 μg L-1. In this case, therefore, a lack of selectivity of the LLLME-UV method was observed, with BPA concentration overestimated at 58%. Figure S12 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. (SI section) shows the spectrum obtained by analyzing the extract of the polycarbonate leach sample. We could observe a similarity with the BPA spectrum (Figure 1), with displacement of the maximum absorption wavelengths to a more energetic region, indicating a change in the chemical composition of the extract. This variation can be caused by the leaching of other components of the analyzed plastic material such as other monomers and additives used in its manufacture. Although analysis of this high temperature leaching polycarbonate sample did not yield accurate results, we should note that it provides useful information to the analyst: it served as a strong indication of BPA presence and of the need for a more detailed examination (such as GC-MS analysis) even without reporting its exact concentration. Similarly, it served to prove that other compound(s) leached from this material.

A univariate test was conducted to evaluate the method limitations regarding samples with high organic matter content. Figure S13 Supplementary Information Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file. (SI section) shows the pattern of absorbance as a function of added humic acid in the sample not containing BPA. For analysis of waters with low organic matter, there is a safe limit of variation of analytical response (absorbance) without the false detection of BPA.

In specific cases, in which the sample has humic acid concentrations higher than 2.5 mg L-1, BPA may be erroneously detected due to an absorbance greater than 0.05. Extreme cases, in which the concentration exceeds 10 mg L-1, BPA may be falsely quantified, indicating a severe error.

Nevertheless, the method developed allows accurate analysis of environmental samples of low organic content, corresponding especially to tap, bottled water, wells, and to fairly clean rivers and lakes.

Conclusions

The LLLME-UV method proposed in this study showed a satisfactory applicability scope of types of aqueous samples, with low cost and high efficiency, and some limitations in terms of humic acid, phenols and phthalates concentration in the samples. The main quality parameters of the LLLME-UV method presented excellent values, both in terms of accuracy, precision and limits of detection.

The method was shown to be useful for the study of BPA leaching for food simulant, being in line with ANVISA and European Union resolutions. Furthermore, the method was shown to be an excellent alternative for both UV detections, serving for qualitative (screening) or quantitative purposes, and GC-MS separation/detection, for a more unequivocal identification and quantification in the case of much more complex samples.

Supplementary Information

Supplementary data are available free of charge at http://jbcs.sbq.org.br as PDF file.

Acknowledgments

The authors are grateful to the Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) and Fundação de Amparo à Pesquisa e Inovação do Estado de Santa Catarina (FAPESC) for their financial support. This study was also financed in part by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Brazil (CAPES), finance code 001. The authors are especially grateful to the Universidade do Estado de Santa Catarina for sponsoring the publication of this work.

References

  • 1
    Sauvé, S.; Desrosiers, M.; Chem. Cent. J. 2014, 8, 15.
  • 2
    https://www.researchandmarkets.com/research/4xx8j9/bisphenola_a, accessed in March 2020.
    » https://www.researchandmarkets.com/research/4xx8j9/bisphenola_a
  • 3
    Flint, S.; Markle, T.; Thompson, S.; Wallace, E.; J. Environ. Manage. 2012, 104, 19.
  • 4
    Michałowicz, J.; Environ. Toxicol. Pharmacol. 2014, 37, 738.
  • 5
    Dodds, E. C.; Goldberg, L.; Lawson, W.; Robinson, R.; Nature 1938, 141, 247.
  • 6
    Schug, T. T.; Janesick, A.; Blumberg, B.; Heindel, J. J.; J. Steroid Biochem. Mol. Biol. 2011, 127, 204.
  • 7
    Prieto, A.; Schrader, S.; Moeder, M.; J. Chromatogr. A 2010, 1217, 6002.
  • 8
    Liu, R.; Zhou, J. L.; Wilding, A.; J. Chromatogr. A 2004, 1022, 179.
  • 9
    Iparraguirre, A.; Prieto, A.; Navarro, P.; Olivares, M.; Fernández, L. Á.; Zuloaga, O.; Anal. Bioanal. Chem. 2011, 401, 339.
  • 10
    Guitart, C.; Readman, J. W.; Anal. Chim. Acta 2010, 658, 32.
  • 11
    Xu, Z.; Wu, Q.; Duan, Y.; Yang, M.; Ou, M.; Xu, X.; J. Braz. Chem. Soc. 2017, 28, 1475.
  • 12
    Li, J.; Zhang, X.; Liu, Y.; Tong, H.; Xu, Y.; Liu, S.; Talanta 2013, 117, 281.
  • 13
    Chu, G.; Cai, W.; Shao, X.; Talanta 2015, 136, 29.
  • 14
    Xu, J.; Li, Y.; Bie, J.; Jiang, W.; Guo, J.; Luo, Y.; Shen, F.; Sun, C.; Microchim. Acta 2015, 182, 2131.
  • 15
    Yıldırım, E.; Gürkan, R.; Altunay, N.; Food Anal. Methods 2017, 10, 1765.
  • 16
    Amiridou, D.; Voutsa, D.; J. Hazard. Mater. 2011, 185, 281.
  • 17
    Gatselou, V. A.; Giokas, D. L.; Vlessidis, A. G.; Anal. Chim. Acta 2014, 812, 121.
  • 18
    Sánchez-Avila, J.; Tauler, R.; Lacorte, S.; Environ. Int. 2012, 46, 50.
  • 19
    Zaki, G.; Shoeib, T.; Sci. Total Environ. 2018, 618, 142.
  • 20
    Statistica, 7.0; StatSoft, Inc., Tulsa, OK, USA, 2004.
  • 21
    Biedermann-Brem, S.; Grob, K.; Eur. Food Res. Technol. 2009, 228, 679.
  • 22
    Agência Nacional de Vigilância Sanitária (ANVISA); Resolução No. 17, de 17 de Março de 2008; Dispõe sobre Regulamento Técnico sobre Lista Positiva de Aditivos para Materiais Plásticos Destinados à Elaboração de Embalagens e Equipamentos em Contato com Alimentos; ANVISA: Brasília, 2008. Available at bvsms.saude.gov.br/bvs/saudelegis/anvisa/2008/res0017_17_03_2008.html, accessed in March 2020.
    » bvsms.saude.gov.br/bvs/saudelegis/anvisa/2008/res0017_17_03_2008.html
  • 23
    European Commission; Commission Regulation (EU) No. 10/2011 of 14 January 2011 on Plastic Materials and Articles Intended to Come into Contact with Food; Official Journal of the European Union: Brussels, 2011. Available at https://eur-lex.europa.eu/legal-content/EN/ALL/?uri=CELEX%3A32011R0010, accessed in March 2020.
    » https://eur-lex.europa.eu/legal-content/EN/ALL/?uri=CELEX%3A32011R0010
  • 24
    D’Antuono, A.; Dall’Orto, V. C.; Lo Balbo, A.; Sobral, S.; Rezzano, I.; J. Agric. Food Chem. 2001, 49, 1098.
  • 25
    Rambla-Alegre, M.; Esteve-Romero, J.; Carda-Broch, S.; J. Chromatogr. A 2012, 1232, 101.
  • 26
    Horwitz, W.; Anal. Chem. 1982, 54, 67.
  • 27
    AOAC Official Methods of Analysis; Appendix F: Guidelines for Standard Method Performance Requirements; AOAC International: Gaithersburg, MD, 2016. Available at http://www.eoma.aoac.org/app_f.pdf, accessed in March 2020.
    » http://www.eoma.aoac.org/app_f.pdf

Publication Dates

  • Publication in this collection
    27 July 2020
  • Date of issue
    Aug 2020

History

  • Received
    30 Oct 2019
  • Accepted
    13 Mar 2020
Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
E-mail: office@jbcs.sbq.org.br