Side effects of intraoral devices for OSAS treatment Please cite this article as: Teixeira AO, Andrade AL, Almeida RC, Almeida MA. Side effects of intraoral devices for OSAS treatment. Braz J Otorhinolaryngol. 2018;84:772-80.

Abstract

Introduction:

Intraoral devices have increasingly assumed a key role in the treatment of obstructive sleep apnea syndrome, but there are limitations to their indication and side effects that result from their continuous use, as well as the use of the continuous positive airway pressure device.

Objectives:

To evaluate the changes in dental positioning caused by the continuous use of mandibular advancement devices.

Methods:

A prospective longitudinal study with a sample of 15 patients, with evaluation of complete documentation after a mean time of 6.47 months, assessed changes in dental positioning due to the use of the Twin Block oral device for the treatment of patients with apnea. The following variables were evaluated: overjet, overbite, upper and lower intermolar distances, upper and lower intercanine distances, Little's irregularity index and the incisor mandibular plane angle. An intraclass correlation test was performed and a correlation index > 0.08 was accepted. After verifying the normal sample distribution (Shapiro-Wilks), a parametric test was used (t test), with a significance level set at 5%.

Results:

There was a decrease in the values of overjet, overbite and Little's irregularity index, whereas there was an increase in the lower intercanine distance and IMPA values. All these variables are influenced, at different levels, by the forward inclination of the lower incisors, an action that can be expected due to the force applied by the device on the dentition. The other variables did not show statistically significant differences.

Conclusion:

After a mean time of 6.47 months of use of the mandibular advancement device, there were statistically significant changes in the dental positioning, but they were not clinically relevant. However, it is relevant that this device is commonly in use over long periods of time, making the monitoring of these patients of the utmost importance for the duration of their therapy.

KEYWORDS
Obstructive sleep apnea syndrome; Mandibular advancement; Continuous positive airway pressure

Resumo:

Introdução:

Os aparelhos intraorais têm assumido cada vez mais um papel importante no tratamento da síndrome da apneia obstrutiva do sono, mas existem limitações a sua indicação e efeitos colaterais com o seu uso contínuo, assim como com o uso do aparelho de pressão aérea positiva contínua.

Objetivos:

Avaliar as alterações no posicionamento dentário produzido pelo uso contínuo do aparelho de projeção mandibular.

Método:

Através de estudo longitudinal prospectivo com amostra de 15 pacientes, com avaliação de documentações completas após um tempo médio de 6,47 meses do uso do aparelho oral de Twin Block para tratamento de pacientes com apneia, foram avaliadas as alterações do posicionamento dos dentes decorrentes do seu uso. As seguintes variáveis foram avaliadas: overjet, overbite, distâncias intermolares superior e inferior, distâncias intercaninos superior e inferior, índice de irregularidade de Little e ângulo do plano incisivo mandibular. Foi feito teste de correlação intraclasse e foram aceitos índices de correlação acima de 0,08. Após atestada a distribuição normal da amostra (Shapiro-Wilks), foi usado um teste paramétrico (teste t), com nível de significância de 5%.

Resultados:

Houve diminuição nos valores de overjet, overbite e irregularidade de Little e aumento nos valores da distância intercanino inferior e do ângulo do plano incisivo mandibular. Todas essas variáveis sofrem influência, com diferentes expressividades, da inclinação para frente dos incisivos inferiores, uma ação que pode ser esperada devido à força aplicada pelo aparelho sobre a dentição. As demais variáveis não demostraram diferenças estatisticamente significativas.

Conclusão:

Houve mudanças estatisticamente significativas no posicionamento dos dentes, porém clinicamente sem relevância, com um tempo médio de uso de 6,47 meses do aparelho de avanço mandibular. Contudo, deve-se considerar que o uso dessa aparelhagem é comum durante longos períodos, fazendo com que seja de suma importância o acompanhamento desses pacientes a longo prazo.

PALAVRAS-CHAVE
Síndrome da apneia obstrutiva do sono; Avanço mandibular; Pressão positiva contínua nas vias aéreas

Introduction

Obstructive sleep apnea syndrome (OSAS) is characterized by recurrent events of airway obstruction during sleep, resulting in micro-awakenings that interfere with normal sleep architecture.11 Bittencourt LRA. Diagnóstico e tratamento da Síndrome da Apneia Obstrutivado Sono. In: Bittencourt LRA, editor. Síndrome da apnéia obstrutiva do sono: guia prático. São Paulo: Livraria Medica Paulista Editora; 2008. p. 81-93.,22 Abi-Ramia LBP, Almeida MAO, Lima TA, Teixeira AOB. Distúrbios respiratórios do sono e ortodontia. In: Almeida MAO, editor. Ortodontia Multidisciplinar. 1ed. Maringá: Dental Press; 2012. p. 69-83. This syndrome has received much attention because of its high degree of morbidity. Increased number of traffic and work-related accidents33 Togeiro SMGP. Síndrome da apneia e hipopneia obstrutiva do sono (SAHOS): aspectos clínicos e diagnóstico. In: Tufik S, editor. Medicina e biologia do sono. São Paulo: Manole; 2008. p. 248-55. are associated with it, as well as difficult-to-control arterial hypertension and pulmonary hypertension.44 Pignatari SSN, Pereira FC, Avelino MAG, Fujita RR. Noções gerais sobre a síndrome da apnéia e hipopnéia obstrutivas do sono em crianças e o papel da polissonografia. In: Campos CAH, Costa HOO, editors. Tratado de Otorrinolaringologia. São Paulo: Roca; 2002. p. 577-9.

5 Poyares D, Cintra FD, Santos FM, Paola A. Complicações cardiovasculares da SAHOS: implicações fisiopatológicas e mecanismos modulatórios do sistema nervoso autônomo. In: Tufik S, editor. Medicina e biologia do sono. São Paulo: Manole; 2008. p. 298-305.
-66 Warunek SP. Oral device therapy in sleep apnea syndromes: a review. Semin Orthod. 2004;10:73-89. Several types of treatment have been applied to patients aiming to control OSAS. These measures range from sleep hygiene methods77 Bagnato MC. Síndrome da apneia e hipopneia obstrutiva do sono (SAHOS): tratamento higieno-dietetico, medicamentoso e com aparelhos de pressão positiva. In: Tufik S, editor. Medicina e biologia do sono. São Paulo: Manole; 2008. p. 256-62.,88 Bittencourt LRA. Tratamento clínico da síndrome da apneia e hipopneia obstrutiva do sono. In: Campos CAH, Costa HOO, editors. Tratado de Otorrinolaringologia. São Paulo: Roca; 2002. p. 584-93. and body weight reduction to surgical treatments,99 Young D, Collop N. Advances in the treatment of obstructive sleep apnea. Curr Treat Options Neurol. 2014;16:305-11. such as maxillo-mandibular advancements, nasal surgeries and tracheostomies.1010 Fugita RR, Moysés MG, Vuono IM. Ronco e apnéia do sono. In: Campos CAH, Costa HOO, editors. Tratado de Otorrinolaringologia. São Paulo: Roca; 2002. p. 637-43. However, the most commonly used methods are those aimed at the clinical control of the obstructive phenomena.1111 Okuno K, Sato K, Arisaka T, Hosohama K, Gotoh M, Taga H, et al. The effect of oral devices that advanced the mandible forward and limited mouth opening in patients with obstructive sleep apnea: a systematic review and meta-analysis of randomised controlled trials. J Oral Rehabil. 2014;41:542-54. Among the most common are the Continuous Positive Airway Pressure (CPAP) and intraoral devices.1212 Health Quality Ontario. Oral devices for obstructive sleep apnea: an evidence-based analysis. Ont Health Technol Assess Ser. 2009;9:1-51.

13 Lim J, Lasserson TJ, Fleetham JA, Wright JJ. Oral applainces for obstructive sleep apnoea (Review). Cochrane Database Syst Rev. 2009;:CD003136.
-1414 Hou HM, Sam K, Hägg U, Rabie ABM, Bendeus M, Yam LYC, et al. Long-term dentofacial changes in Chinese obstructive sleep apnea patients after treatment with mandibular advancement device. Angle Orthod. 2005;76:432-40. There is a great diversity of intraoral devices available in the market that are used to treat OSAS.1313 Lim J, Lasserson TJ, Fleetham JA, Wright JJ. Oral applainces for obstructive sleep apnoea (Review). Cochrane Database Syst Rev. 2009;:CD003136. There are devices that pull the tongue musculature into a bulb (TRD - Tongue Retainer Device), plastic devices sold directly to patients without any individualization, and several types of individualized mandibular advancement devices. The most commonly used intraoral devices that show greater efficiency, are those that provide individualized mandibular advancement taking with it all the suprahyoid muscles, promoting airway widening, mainly in the oropharyngeal region.1515 Almeida FR, Dal-Fabro C, Chaves Júnior CM. Síndrome da apneia e hipopneia obstutiva do sono (SAHOS): tratamento com aparelhos intraorais. In: Tufik S, editor. Medicina e biologia do sono. São Paulo: Manole; 2008. p. 263-80.,1616 Conley RS. Management of sleep apnea: a critical look at intra-oral devices. Orthod Craniofac Res. 2015;18:83-90. The Twin Block is one of those devices that promote individualized mandibular advancement, and attains promising results in the treatment of OSAS.22 Abi-Ramia LBP, Almeida MAO, Lima TA, Teixeira AOB. Distúrbios respiratórios do sono e ortodontia. In: Almeida MAO, editor. Ortodontia Multidisciplinar. 1ed. Maringá: Dental Press; 2012. p. 69-83. Although the CPAP is considered the gold standard treatment for OSAS,1717 ASDA. Practice parameters for the treatment of snoring and obstructive sleep apnea with oral devices. Sleep. 1995;8:511-3.,1818 Sutherland K, Vanderveken OM, Tsuda H, Marklund M, Gagnadoux F, Kushida CA, et al. Oral Device Treatment for Obstructive Sleep Apnea: An Update. J Clin Sleep Med. 2014;10:215-27. intraoral devices can already be considered the first-choice treatment for cases of primary snoring, UARS (Upper Airway Resistance Syndrome), mild to moderate OSAS, as well as being a secondary management strategy for patients with severe OSAS who do not adhere to CPAP treatment, because many find CPAP uncomfortable. This makes adherence to oral devices higher than to CPAP.1313 Lim J, Lasserson TJ, Fleetham JA, Wright JJ. Oral applainces for obstructive sleep apnoea (Review). Cochrane Database Syst Rev. 2009;:CD003136.,1818 Sutherland K, Vanderveken OM, Tsuda H, Marklund M, Gagnadoux F, Kushida CA, et al. Oral Device Treatment for Obstructive Sleep Apnea: An Update. J Clin Sleep Med. 2014;10:215-27.,1919 Milano F, Billi MC, Marra F, Sorrenti G, Gracco A, Bonetti GA. Factors associated with the efficacy of mandibular advancing device treatment in adult OSA patients. Int Orthod. 2013;11:278-89. Recent studies have demonstrated that although patients generally have less reduction in the indeces that measure disease severity, such as the Apnea and Hypopnea Index (AHI) per hour of sleep, the reduction in blood pressure is similar with the intraoral device compared to CPAP, and there is no difference in the prevention of deaths from cardiovascular diseases caused by OSAS.99 Young D, Collop N. Advances in the treatment of obstructive sleep apnea. Curr Treat Options Neurol. 2014;16:305-11.,2020 Anandam A, Patil M, Akinnusi M, Jaoude P, El Solh AA. Cardiovascular mortality in obstructive sleep apnea treated with continuous positive airway pressure or oral device: an observational study. Respirol. 2013;18:1184-90. Intraoral devices are increasingly assuming a more important role in the treatment of this syndrome, but there are limitations to their indications and side effects that occur with their continuous use, just as there are with the use of CPAP.1818 Sutherland K, Vanderveken OM, Tsuda H, Marklund M, Gagnadoux F, Kushida CA, et al. Oral Device Treatment for Obstructive Sleep Apnea: An Update. J Clin Sleep Med. 2014;10:215-27.,2121 Kim YK, Kim JW, Yoon IY, Rhee CS, Lee CH, Yun PY. Influencing factors on the effect of mandibular advancement device in obstructive sleep apnea patients: analysis on cephalometric and polysomnographic parameters. Sleep breath. 2014;18:305-11.,2222 White DP, Shafazand S. Mandibular advancement Device vs CPAP in the treatment of obstructive Sleep apnea: are they equally effective in Short term Health outcomes? J Clin Sleep Med. 2013;9:971-2. The main limitation regarding the indication of mandibular advancement devices is the need for a minimum number of teeth in good condition for device fixation.22 Abi-Ramia LBP, Almeida MAO, Lima TA, Teixeira AOB. Distúrbios respiratórios do sono e ortodontia. In: Almeida MAO, editor. Ortodontia Multidisciplinar. 1ed. Maringá: Dental Press; 2012. p. 69-83.,1515 Almeida FR, Dal-Fabro C, Chaves Júnior CM. Síndrome da apneia e hipopneia obstutiva do sono (SAHOS): tratamento com aparelhos intraorais. In: Tufik S, editor. Medicina e biologia do sono. São Paulo: Manole; 2008. p. 263-80. With respect to the side effects, much atention is given to those related to CPAP, such as difficult adherence, nasal congestion, airway dryness, it seems that less attention is given to the side effects produced by intraoral devices.2323 Ueda H, Almeida FR, Lowe A, Ruse ND. Changes in occlusal contact area during oral device therapy assessed on study models. Angle Orthod. 2008;78:866-72.

24 Ngiam J, Balasubramaniam R, Darendeliler MA, Cheng AT, Waters K, Sullivan CE. Clinical guidelines for oral device therapy in the treatment of snoring and obstructive sleep apnoea. Aust Dent J. 2013;58:408-19.

25 Martinez-Gomis J, Willaert E, Nogues L, Pascual M, Somoza M, Monasterio C. Five years of sleep apnea treatment with a mandibular advancement device. Side effects and technical complications. Angle Orthod. 2010;80:30-6.
-2626 Almeida MAO, Teixeira AOB, Vieira LS, Quintão CCA. Tratamento da síndrome da apneia e hipopneia obstrutiva do sono com aparelhos intrabucais. Rev Bras Otorrinolaringol. 2006;72:699-703. This study assessed the changes in dental positioning resulting from the use of a mandibular advancement device, an effect that may impair patient dental occlusion and eventually lead to the discontinuation of this type of treatment.

Method

This is a longitudinal prospective study, which assessed complete documentation (Fig. 1A and 1B), consisting of lateral cephalometric radiographs and initial and final cephalometric models (T1 and T2 respectively), after a mean time of 6.47 months of use of the oral device for the treatment of patients with mild to moderate OSAS, using a Twin Block mandibular protraction device2727 Olibone VL, Guimarães AS, Atta JY. Influência do aparelho propulsor Twin Block no crescimento mandibular: revisão sistemática da literatura. Rev Dent Press Ortodon Ortopedi Facial. 2006;11:19-27. (Fig. 2). Cephalometric models and radiographs of patients who had all the necessary teeth (upper and lower first molars, upper and lower canines and the four lower incisors) were included in the sample to reproduce the measures that were assessed in this study.

Figure 1
A, Study models used for assessment. These models were scanned so that the digital measurements could be performed. B, Radiographs used to assess the position of the incisors.

Figure 2
Twin Block Device.

Fifteen patients who met the inclusion criteria were included in this study sample (Table 1) and their documentation was obtained and later assessed.

Table 1
Values of Apnea and Hypopnea Index (AHI), Body Mass Index (BMI), age and gender of the patients in the sample.

The models were scanned using the Maestro 3D scanner (Fig. 3), with acquisition technology using the structured light projection technique, acquisition speed of thousands of points in a few seconds, accuracy of 10 microns and resolution of 0.07 mm, using the Maestro 3D Easy Dental Scan program, through which the upper, lower and occlusion models were digitized and then superimposed, creating 3 "floating points" in the upper and lower models and 3 "fixed points" in the occlusion models, where they should be in the same position in both, so there would be a better alignment between these models (Fig. 4A and 4B). Afterwards, they were imported into the 3D Maestro Ortho Studio program for the manipulation and definition of the sagittal, occlusal and transverse planes, represented by the X, Y and Z planes, respectively, of each digital model pair in occlusion (Fig. 4C) and then exported to the Geomagic Qualify 2013, where measurements of the digital models were reproduced.

Figure 3
Maestro Scanner 3D image.

Figure 4
A, Overlapping of the models using the Maestro 3D Easy Dental Scan program (Upper Model); B, Overlapping of the models using the Maestro 3D Easy Dental Scan program (Lower Model); and C, Definition of the sagittal, occlusal and transverse planes (X, Y and Z) using the Maestro 3D Ortho Studio program.

The cephalometric radiographs were scanned in an HP Scanjet 4890 scanner and traced by the Dolphin Imaging software through an analysis specifically designed to reproduce the measurement that would be assessed.

The measurements obtained from the scanned models before and after treatment with the Twin Block device were reproduced, in order to determine any intra- and inter-arch changes, such as:

  • - Upper and lower intercanine distance (UICD and LICD respectively): measured from one tip to the other tip of the canine cusp in millimeters (mm) in the X plane in both arches (Fig. 5);

    Figure 5
    Visualization of intercanine and intermolar distance measurement.

  • - Upper and lower intermolar distance (UIMD and LIMD respectively): measured from the one central fossa to another central fossa of the first molars in plane X in millimeters in both arches (Fig. 5);

  • - Anteroinferior dental crowding: it will be assessed based on the analysis of Little's Irregularity2828 Little RM. The irregularity index: a quantitative score of mandibular anterior alignment. Am J Orthod. 1975;68:554-63.

    29 Little RM, Wallen TR, Riedel RA. Stability and relapse of mandibular anterior alignment-first premolar extraction cases treated by traditional edgewise orthodontics. Am J Orthod. 1981;80:349-65.
    -3030 Little RM, Riedel RA, Artun J. An evaluation of changes in mandibular anterior alignment from 10 to 20 years postretention. Am J Orthod Dentofacial Orthop. 1988;93:423-8. in the lower arch, through the summation in millimeters of the contact points from one canine mesial surface to another, represented by the letters A, B, C, D and E (Fig. 6A and B);

    Figure 6
    A, Drawing representing the measurement of the distances to calculate Little's Irregularity index; B, Measurement performed on the digital model.

  • - Horizontal distance between the upper anterior teeth and the lower anterior teeth (overjet): measured from the most vestibular incisal border of the upper incisor to the incisal border of the lower incisor in millimeters, horizontally, represented by the Z plane (Fig. 7);

    Figure 7
    Measurement of Overjet (Plane Z) and Overbite (Plane Y) on digital model.

  • - Amount of overlapping of anteroinferior teeth by the anterosuperior teeth (overbite): measured from the amount of vertical overlap of the incisal border of the central upper incisor to the incisal border of the more extruded lower central incisor in millimeters, vertically,3131 Hedge S, Panwar S, Bolar DR. Characteristics of occlusion in primary dentition of preschool children of Udaipur, India. Eur J Dent. 2012;6:51-5. represented by plane Y (Fig. 7);

  • - The angulation of the lower incisors was assessed in the lateral cephalometric radiographs taken before and after treatment, which in the case of this study, were analyzed through Tweed's IMPA angle,3232 Tweed CH. The Frankfort-mandibular plane angle in orthodontic diagnosis, classification, treatment planning, and prognosis. Am J Orthod. 1946;32:175-230.,3333 Tweed CH. The diagnostic facial triangle in the control of treatment objectives. Am J Orthod. 1969;55:651-67. consisting of the mandibular plane, traced using as reference a plane tangential to the lower border of the mandible and the long axis of the lower incisor.

The variables were measured twice, in 10 pairs of cephalometric models and 10 cephalometric radiographs (5 pairs of models and 5 radiographs at time T1 and the other half at time T2, corresponding to 30% of the sample) randomly selected by the same evaluator with a minimum interval of two weeks, with the results between the measures being compared using the intraclass correlation test; a correlation index > 0.08 was accepted.

The software Statistica 7.0 was used to perform the statistical tests. The Shapiro-Wilks Test - W test was used to verify the normality of the sample data. The interpretation of the observed variable values of overjet, overbite, UIMD, LIMD, UICD, LICD, Little's Irregularity and IMPA was performed with a decision level of α = 0.05. After verifying the normal distribution of the sample, a parametric test (t test), with a significance level of 5%, was used to compare the several parameters at times T1 and T2.

The research project was registered in the Brazil Platform and submitted to the Research Ethics Committee for approval, obtaining a favorable opinion (CAAE nº 34300714.0.0000.5259). All patients signed the Free and Informed Consent Form (FICF) for inclusion in the study.

Results

The patients included in the sample underwent analysis of their documentation, cephalometric models and lateral radiographs at the initial moment (T1) and after 6.47 months (SD = 2.01) of use of the Twin Block device (T2). The measurements were repeated after a two-week interval, and good reproducibility of these variables was verified (Tables 2 and 3).

Table 2
Results of the t-Test for paired samples of before and after type, for the variable method error with a two-week interval on T1.
Table 3
Results of the t-Test for paired samples of before and after type, for the variable method error with a two-week interval on T2.

The Shapiro-Wilks test - W test confirmed the normality of the sample (p > 0.05) (Table 4).

Table 4
Results of the Shapiro-Wilks normality test, W test, for the variables under study.

The pairs were then compared using Student's t-test to verify differences in dental positioning between the two times (T1 and T2) due to the use of the mandibular advancement device. The variables that showed statistically significant differences were overjet, overbite, LICD, Little's Irregularity and IMPA (Table 5 and Fig. 8). There was a decrease in the overjet, overbite and Little's Irregularity values and an increase in the values of LICD and IMPA. All these variables are influenced, at different levels, by the forward inclination of the lower incisors, an action that can be expected due to the force applied by the device on the dentition. The other variables (UICD, UIMD, LIMD) did not show any statistically significant differences.

Table 5
Results of the t-test for paired samples, of before and after type.

Figure 8
Comparison between the means of the variables observed at times T1 and T2.

Discussion

Awareness of the appropriate indications for the use of intraoral devices to treat OSAS is of utmost importance so they can be utilized when it will be most beneficial to the patient.

The short-term side effects caused by the devices are already well known.3434 Neill A, Whyman R, Bannan S, Jeffrey O, Campbell A. Mandibular advancement splint improves indices of obstructive sleep apnoea and snoring but side effects are common. N Z Med J. 2002;115:289-92.

35 Clark GT, Sohn JW, Hong CN. Treating obstructive sleep apnea and snoring: assessment of an anterior mandibular positioning device. J Am Dent Assoc. 2000;131:765-71.

36 Fransson AMC, Tegelberg A, Johansson A, Wenneberg B. Influence on the masticatory system in treatment of obstructive sleep apnea and snoring with a mandibular protruding device: a 2-year follow-up. Am J Orthod Dentofacial Orthop. 2004;126:687-93.
-3737 Bondemark L, Lindman R. Craniomandibular status and function in patients with habitual snoring and obstructive sleep apnoea after nocturnal treatment with a mandibular advancement splint: a 2-year follow-up. Eur J Orthod. 2000;22:53-60. The medium and long-term effects still need further studies and greater understanding so they can be diagnosed and treated,3838 Robertson CJ. Dental and skeletal changes associated with long-term mandibular advancement. Sleep. 2001;24:531-7.

39 Almeida FR, Lowe AA, Otsuka R, Fastlicht S, Farbood M, Tsuiki S. Long-term sequellae of oral device therapy in obstructive sleep apnea patients: Part 2. Study-model analysis. Am J Orthod Dentofacial Orthop. 2006;129:205-13.
-4040 Marklund MM. Predictors of long-term orthodontic side effects from mandibular advancement devices in patients with snoring and obstructive sleep apnea. Am J Orthod Dentofacial Orthop. 2006;129:214-21. which is very important, since any clinical intervention for the treatment of OSAS should be considered a long-term therapy.

This study aimed to evaluate the dental changes produced by a device used in the treatment of OSAS that advances the mandible. Statistically significant alterations were observed in overjet, overbite, LICD, Little's Irregularity and IMPA, all of which can be explained by the projection of the lower incisors, probably occurring due to the projection force applied to the lower arch by the device. These data are in agreement with the studies of Marklund et al.,4141 Marklund MM, Franklin KA, Persson M. Orthodontic side-effects of mandibular advancement devices during treatment of snoring and sleep apnoea. Eur J Orthod. 2001;23:135-44. who found changes in overjet of -0.4 mm ± 0.8 mm and of -0.4 mm ± 0.7 mm in overbite, in agreement with the results of Hammond et al.,4242 Hammond RJ, Gotsopoulos H, Shen G, Petocz P, Cistulli PA, Darendeliler MA. A follow-up study of dental and skeletal changes associated with mandibular advancement splint use in obstructive sleep apnea. Am J Orthod Dentofacial Orthop. 2007;132:806-14. who found statistically significant changes in the anterior movement of lower incisors of 0.5 ± 0.12 mm, even though, according to these authors, they were not clinically significant, also similar to those of Roberton, Herbison and Harkness,4343 Robertson C, Herbison P, Harkness M. Dental and occlusal changes during mandibular advancement splint therapy in sleep disordered patients. Eur J Orthod. 2003;25:371-6. who also observed these changes in overjet and overbite, and the study of Martinez et al.,2525 Martinez-Gomis J, Willaert E, Nogues L, Pascual M, Somoza M, Monasterio C. Five years of sleep apnea treatment with a mandibular advancement device. Side effects and technical complications. Angle Orthod. 2010;80:30-6. who observed changes in incisor inclination, in addition to molar position alterations, similar to those found in our study.

An important factor in dental modifications may be the amount of projection caused by these devices. Marklund et al.4141 Marklund MM, Franklin KA, Persson M. Orthodontic side-effects of mandibular advancement devices during treatment of snoring and sleep apnoea. Eur J Orthod. 2001;23:135-44. concluded that the orthodontic side effects obtained during treatment with an intraoral device for snoring and apnea syndrome are small, especially if the advancement of this mandibular device is less than 6.0 mm. In this study, the mandibular advancement achieved in the patients ranged from 5.0 to 8.0 mm, and in most patients this advancement was greater than 6.0 mm. It is worth mentioning that the best results, considering the reduction in AHI, are found when an advancement ≥ 75% of maximal protrusive capacity is achieved, which often exceeds 6.0 mm.

Another important issue may be the time of follow-up,2323 Ueda H, Almeida FR, Lowe A, Ruse ND. Changes in occlusal contact area during oral device therapy assessed on study models. Angle Orthod. 2008;78:866-72.,3838 Robertson CJ. Dental and skeletal changes associated with long-term mandibular advancement. Sleep. 2001;24:531-7.

39 Almeida FR, Lowe AA, Otsuka R, Fastlicht S, Farbood M, Tsuiki S. Long-term sequellae of oral device therapy in obstructive sleep apnea patients: Part 2. Study-model analysis. Am J Orthod Dentofacial Orthop. 2006;129:205-13.
-4040 Marklund MM. Predictors of long-term orthodontic side effects from mandibular advancement devices in patients with snoring and obstructive sleep apnea. Am J Orthod Dentofacial Orthop. 2006;129:214-21. as these changes seem to be progressive. In our study, although the statistical data showed values with clinically significant differences, they might not be relevant, since the differences between T1 and T2 in these variables were small. This fact may be related to the time of follow-up of 6.47 months. However, in the studies by Marklund, Franklin and Persson4141 Marklund MM, Franklin KA, Persson M. Orthodontic side-effects of mandibular advancement devices during treatment of snoring and sleep apnoea. Eur J Orthod. 2001;23:135-44. and Marklund,4040 Marklund MM. Predictors of long-term orthodontic side effects from mandibular advancement devices in patients with snoring and obstructive sleep apnea. Am J Orthod Dentofacial Orthop. 2006;129:214-21. for instance, with a time of follow-up of approximately 2.5 ± 0.5 years and 5.4 ± 0.8 years respectively, different from the length of time evaluated in this study, the results were shown to be similar. The same was also observed by Fransson et al.3636 Fransson AMC, Tegelberg A, Johansson A, Wenneberg B. Influence on the masticatory system in treatment of obstructive sleep apnea and snoring with a mandibular protruding device: a 2-year follow-up. Am J Orthod Dentofacial Orthop. 2004;126:687-93. who followed 65 patients using the mandibular advancement device for two years. In the studies carried out by Almeida et al.,3939 Almeida FR, Lowe AA, Otsuka R, Fastlicht S, Farbood M, Tsuiki S. Long-term sequellae of oral device therapy in obstructive sleep apnea patients: Part 2. Study-model analysis. Am J Orthod Dentofacial Orthop. 2006;129:205-13.,4444 Almeida FR, Lowe AA, Sung JO, Tsuiki S, Otsuka R. Long-term sequellae of oral device therapy in obstructive sleep apnea patients: Part 1. Cephalometric analysis. Am J Orthod Dentofacial Orthop. 2006;129:195-204. which assessed the use of the mandibular advancement device for the treatment of OSAS with a long-term evaluation, on average 7.4 years, with 70 patients having their plaster models of the dental arches and cephalometric radiographs visually compared, it was observed that changes occurred in 85.7% of the cases. Similar results were found by Robertson,3838 Robertson CJ. Dental and skeletal changes associated with long-term mandibular advancement. Sleep. 2001;24:531-7. who demonstrated that the most significant dental changes occurred at the 30-month follow-up, stating that dental and skeletal changes may be progressive over time. He then recommended that all patients should be informed of the potential of these changes prior to treatment and be followed by a dentist throughout treatment. The same recommendation was given by Clark, Sohn and Hong3535 Clark GT, Sohn JW, Hong CN. Treating obstructive sleep apnea and snoring: assessment of an anterior mandibular positioning device. J Am Dent Assoc. 2000;131:765-71. and by Perez et al.,4545 Perez CV, Leeuw R, Okeson JP, Carlson CR, Li HF, Bush HM, et al. The incidence and prevalence of temporomandibular disorders and posterior open bite in patients receiving mandibular advancement device therapy for obstructive sleep apnea. Sleep Breath. 2013;17:323-32. who also observed that 26% of users of mandibular advancement devices experienced a painless, but irreversible change in their occlusions.

These changes must be followed closely by a dentist, as they occur most of the time without the patients noticing it. Almeida et al.,2626 Almeida MAO, Teixeira AOB, Vieira LS, Quintão CCA. Tratamento da síndrome da apneia e hipopneia obstrutiva do sono com aparelhos intrabucais. Rev Bras Otorrinolaringol. 2006;72:699-703. based on a literature review aimed at answering the main doubts regarding the use of intraoral devices for the treatment of OSAS, concluded that the main occlusal side effects were overjet reduction, overbite reduction, proclination of the lower incisors, and establishment of a lateral open bite, although most of the times without generating great discomfort to the patients, in agreement with Perez et al.4545 Perez CV, Leeuw R, Okeson JP, Carlson CR, Li HF, Bush HM, et al. The incidence and prevalence of temporomandibular disorders and posterior open bite in patients receiving mandibular advancement device therapy for obstructive sleep apnea. Sleep Breath. 2013;17:323-32.

Conclusions

There were statistically significant changes in overjet, overbite, LICD, Little's Irregularity and IMPA, but these were not clinically relevant, after a mean time of use of 6.47 months; however, it must be considered that these devices are commonly used for long periods of time, making it very important to follow these patients for the duration of treatment.

  • Please cite this article as: Teixeira AO, Andrade AL, Almeida RC, Almeida MA. Side effects of intraoral devices for OSAS treatment. Braz J Otorhinolaryngol. 2018;84:772-80.
  • Peer Review under the responsibility of Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.

References

  • 1
    Bittencourt LRA. Diagnóstico e tratamento da Síndrome da Apneia Obstrutivado Sono. In: Bittencourt LRA, editor. Síndrome da apnéia obstrutiva do sono: guia prático. São Paulo: Livraria Medica Paulista Editora; 2008. p. 81-93.
  • 2
    Abi-Ramia LBP, Almeida MAO, Lima TA, Teixeira AOB. Distúrbios respiratórios do sono e ortodontia. In: Almeida MAO, editor. Ortodontia Multidisciplinar. 1ed. Maringá: Dental Press; 2012. p. 69-83.
  • 3
    Togeiro SMGP. Síndrome da apneia e hipopneia obstrutiva do sono (SAHOS): aspectos clínicos e diagnóstico. In: Tufik S, editor. Medicina e biologia do sono. São Paulo: Manole; 2008. p. 248-55.
  • 4
    Pignatari SSN, Pereira FC, Avelino MAG, Fujita RR. Noções gerais sobre a síndrome da apnéia e hipopnéia obstrutivas do sono em crianças e o papel da polissonografia. In: Campos CAH, Costa HOO, editors. Tratado de Otorrinolaringologia. São Paulo: Roca; 2002. p. 577-9.
  • 5
    Poyares D, Cintra FD, Santos FM, Paola A. Complicações cardiovasculares da SAHOS: implicações fisiopatológicas e mecanismos modulatórios do sistema nervoso autônomo. In: Tufik S, editor. Medicina e biologia do sono. São Paulo: Manole; 2008. p. 298-305.
  • 6
    Warunek SP. Oral device therapy in sleep apnea syndromes: a review. Semin Orthod. 2004;10:73-89.
  • 7
    Bagnato MC. Síndrome da apneia e hipopneia obstrutiva do sono (SAHOS): tratamento higieno-dietetico, medicamentoso e com aparelhos de pressão positiva. In: Tufik S, editor. Medicina e biologia do sono. São Paulo: Manole; 2008. p. 256-62.
  • 8
    Bittencourt LRA. Tratamento clínico da síndrome da apneia e hipopneia obstrutiva do sono. In: Campos CAH, Costa HOO, editors. Tratado de Otorrinolaringologia. São Paulo: Roca; 2002. p. 584-93.
  • 9
    Young D, Collop N. Advances in the treatment of obstructive sleep apnea. Curr Treat Options Neurol. 2014;16:305-11.
  • 10
    Fugita RR, Moysés MG, Vuono IM. Ronco e apnéia do sono. In: Campos CAH, Costa HOO, editors. Tratado de Otorrinolaringologia. São Paulo: Roca; 2002. p. 637-43.
  • 11
    Okuno K, Sato K, Arisaka T, Hosohama K, Gotoh M, Taga H, et al. The effect of oral devices that advanced the mandible forward and limited mouth opening in patients with obstructive sleep apnea: a systematic review and meta-analysis of randomised controlled trials. J Oral Rehabil. 2014;41:542-54.
  • 12
    Health Quality Ontario. Oral devices for obstructive sleep apnea: an evidence-based analysis. Ont Health Technol Assess Ser. 2009;9:1-51.
  • 13
    Lim J, Lasserson TJ, Fleetham JA, Wright JJ. Oral applainces for obstructive sleep apnoea (Review). Cochrane Database Syst Rev. 2009;:CD003136.
  • 14
    Hou HM, Sam K, Hägg U, Rabie ABM, Bendeus M, Yam LYC, et al. Long-term dentofacial changes in Chinese obstructive sleep apnea patients after treatment with mandibular advancement device. Angle Orthod. 2005;76:432-40.
  • 15
    Almeida FR, Dal-Fabro C, Chaves Júnior CM. Síndrome da apneia e hipopneia obstutiva do sono (SAHOS): tratamento com aparelhos intraorais. In: Tufik S, editor. Medicina e biologia do sono. São Paulo: Manole; 2008. p. 263-80.
  • 16
    Conley RS. Management of sleep apnea: a critical look at intra-oral devices. Orthod Craniofac Res. 2015;18:83-90.
  • 17
    ASDA. Practice parameters for the treatment of snoring and obstructive sleep apnea with oral devices. Sleep. 1995;8:511-3.
  • 18
    Sutherland K, Vanderveken OM, Tsuda H, Marklund M, Gagnadoux F, Kushida CA, et al. Oral Device Treatment for Obstructive Sleep Apnea: An Update. J Clin Sleep Med. 2014;10:215-27.
  • 19
    Milano F, Billi MC, Marra F, Sorrenti G, Gracco A, Bonetti GA. Factors associated with the efficacy of mandibular advancing device treatment in adult OSA patients. Int Orthod. 2013;11:278-89.
  • 20
    Anandam A, Patil M, Akinnusi M, Jaoude P, El Solh AA. Cardiovascular mortality in obstructive sleep apnea treated with continuous positive airway pressure or oral device: an observational study. Respirol. 2013;18:1184-90.
  • 21
    Kim YK, Kim JW, Yoon IY, Rhee CS, Lee CH, Yun PY. Influencing factors on the effect of mandibular advancement device in obstructive sleep apnea patients: analysis on cephalometric and polysomnographic parameters. Sleep breath. 2014;18:305-11.
  • 22
    White DP, Shafazand S. Mandibular advancement Device vs CPAP in the treatment of obstructive Sleep apnea: are they equally effective in Short term Health outcomes? J Clin Sleep Med. 2013;9:971-2.
  • 23
    Ueda H, Almeida FR, Lowe A, Ruse ND. Changes in occlusal contact area during oral device therapy assessed on study models. Angle Orthod. 2008;78:866-72.
  • 24
    Ngiam J, Balasubramaniam R, Darendeliler MA, Cheng AT, Waters K, Sullivan CE. Clinical guidelines for oral device therapy in the treatment of snoring and obstructive sleep apnoea. Aust Dent J. 2013;58:408-19.
  • 25
    Martinez-Gomis J, Willaert E, Nogues L, Pascual M, Somoza M, Monasterio C. Five years of sleep apnea treatment with a mandibular advancement device. Side effects and technical complications. Angle Orthod. 2010;80:30-6.
  • 26
    Almeida MAO, Teixeira AOB, Vieira LS, Quintão CCA. Tratamento da síndrome da apneia e hipopneia obstrutiva do sono com aparelhos intrabucais. Rev Bras Otorrinolaringol. 2006;72:699-703.
  • 27
    Olibone VL, Guimarães AS, Atta JY. Influência do aparelho propulsor Twin Block no crescimento mandibular: revisão sistemática da literatura. Rev Dent Press Ortodon Ortopedi Facial. 2006;11:19-27.
  • 28
    Little RM. The irregularity index: a quantitative score of mandibular anterior alignment. Am J Orthod. 1975;68:554-63.
  • 29
    Little RM, Wallen TR, Riedel RA. Stability and relapse of mandibular anterior alignment-first premolar extraction cases treated by traditional edgewise orthodontics. Am J Orthod. 1981;80:349-65.
  • 30
    Little RM, Riedel RA, Artun J. An evaluation of changes in mandibular anterior alignment from 10 to 20 years postretention. Am J Orthod Dentofacial Orthop. 1988;93:423-8.
  • 31
    Hedge S, Panwar S, Bolar DR. Characteristics of occlusion in primary dentition of preschool children of Udaipur, India. Eur J Dent. 2012;6:51-5.
  • 32
    Tweed CH. The Frankfort-mandibular plane angle in orthodontic diagnosis, classification, treatment planning, and prognosis. Am J Orthod. 1946;32:175-230.
  • 33
    Tweed CH. The diagnostic facial triangle in the control of treatment objectives. Am J Orthod. 1969;55:651-67.
  • 34
    Neill A, Whyman R, Bannan S, Jeffrey O, Campbell A. Mandibular advancement splint improves indices of obstructive sleep apnoea and snoring but side effects are common. N Z Med J. 2002;115:289-92.
  • 35
    Clark GT, Sohn JW, Hong CN. Treating obstructive sleep apnea and snoring: assessment of an anterior mandibular positioning device. J Am Dent Assoc. 2000;131:765-71.
  • 36
    Fransson AMC, Tegelberg A, Johansson A, Wenneberg B. Influence on the masticatory system in treatment of obstructive sleep apnea and snoring with a mandibular protruding device: a 2-year follow-up. Am J Orthod Dentofacial Orthop. 2004;126:687-93.
  • 37
    Bondemark L, Lindman R. Craniomandibular status and function in patients with habitual snoring and obstructive sleep apnoea after nocturnal treatment with a mandibular advancement splint: a 2-year follow-up. Eur J Orthod. 2000;22:53-60.
  • 38
    Robertson CJ. Dental and skeletal changes associated with long-term mandibular advancement. Sleep. 2001;24:531-7.
  • 39
    Almeida FR, Lowe AA, Otsuka R, Fastlicht S, Farbood M, Tsuiki S. Long-term sequellae of oral device therapy in obstructive sleep apnea patients: Part 2. Study-model analysis. Am J Orthod Dentofacial Orthop. 2006;129:205-13.
  • 40
    Marklund MM. Predictors of long-term orthodontic side effects from mandibular advancement devices in patients with snoring and obstructive sleep apnea. Am J Orthod Dentofacial Orthop. 2006;129:214-21.
  • 41
    Marklund MM, Franklin KA, Persson M. Orthodontic side-effects of mandibular advancement devices during treatment of snoring and sleep apnoea. Eur J Orthod. 2001;23:135-44.
  • 42
    Hammond RJ, Gotsopoulos H, Shen G, Petocz P, Cistulli PA, Darendeliler MA. A follow-up study of dental and skeletal changes associated with mandibular advancement splint use in obstructive sleep apnea. Am J Orthod Dentofacial Orthop. 2007;132:806-14.
  • 43
    Robertson C, Herbison P, Harkness M. Dental and occlusal changes during mandibular advancement splint therapy in sleep disordered patients. Eur J Orthod. 2003;25:371-6.
  • 44
    Almeida FR, Lowe AA, Sung JO, Tsuiki S, Otsuka R. Long-term sequellae of oral device therapy in obstructive sleep apnea patients: Part 1. Cephalometric analysis. Am J Orthod Dentofacial Orthop. 2006;129:195-204.
  • 45
    Perez CV, Leeuw R, Okeson JP, Carlson CR, Li HF, Bush HM, et al. The incidence and prevalence of temporomandibular disorders and posterior open bite in patients receiving mandibular advancement device therapy for obstructive sleep apnea. Sleep Breath. 2013;17:323-32.

Publication Dates

  • Publication in this collection
    Nov-Dec 2018

History

  • Received
    15 June 2016
  • Accepted
    23 Sept 2017
Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Sede da Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico Facial, Av. Indianópolia, 1287, 04063-002 São Paulo/SP Brasil, Tel.: (0xx11) 5053-7500, Fax: (0xx11) 5053-7512 - São Paulo - SP - Brazil
E-mail: revista@aborlccf.org.br