Acessibilidade / Reportar erro

Implementation of ventilation towers in a greenhouse established in low altitude tropical climate conditions: numerical approach to the behavior of the natural ventilation

ABSTRACT

Deficient ventilation rates and airflow patterns in naturally ventilated greenhouses are the main causes for the generation of inadequate and heterogeneous thermal conditions inside this type of structure. In this research, a numerical study was developed using a two-dimensional computational fluid dynamics model validated in a Colombian greenhouse established under warm climate conditions (PG). The objective of the research was to evaluate the effect on natural ventilation generated by the coupling of two ventilation towers on the PG greenhouse, scenario called MPG. The results indicated that airflow patterns over the region where crops are established in MPG are between 25.9% and up to 142.5% faster compared to PG, which generates ventilation rates up to 57.3% higher in MPG, which is why the temperature distribution under this scenario is more homogeneous inside the structure and its average thermal differential with the outside environment does not exceed 1.1 °C.

Keywords:
ventilation rates; CFD simulation; air flows; thermal differential

INTRODUCTION

The increase in the world's population, together with the deterioration of natural resources and current and future food demands, is one of the frequent problems that receives the most attention within the working agendas of the governmental and non-governmental entities of the nations (Akrami et al., 2020Akrami M, Javadi AA, Hassanein MJ, Farmani R, Dibaj M, Tabor GR & Negm A (2020) Study of the Effects of Vent Configuration on Mono-Span Greenhouse Ventilation Using Computational Fluid Dynamics. Sustainability, 12:986-998.). One of the alternatives of intensification of the agriculture more promoted for the food production is the agriculture under cover, at present it is estimated that for the production of fresh vegetables there are about 3,220,000 has under this type of productive system and of this total approximately 95% of the area are medium and low technology structures, within which one of the most relevant are passive type greenhouse structures, which are used in more than 115 countries worldwide (Baeza et al., 2020Baeza E, Hemming S & Stanghellini C (2020) Materials with switchable radiometric properties: Could they become the perfect greenhouse cover? Biosystems Engineering, 193:157-173.; Ezzaeri et al., 2020Ezzaeri K, Fatnassi H, Wifaya A, Bazgaou A, Aharoune A, Poncet C & Bouirden L (2020) Performance of photovoltaic canarian greenhouse: A comparison study between summer and winter seasons. Solar Energy, 198:275-282. ).

The main functions of a greenhouse are; to protect the crops from extreme climatic factors, to generate an adequate microclimate for the growth and development of the plants and to protect them from the attack of pests and diseases (Syed & Hachem, 2019Syed AM & Hachem C (2019) Review of Construction; Geometry; Heating, Ventilation, and Air-Conditioning; and Indoor Climate Requirements of Agricultural Greenhouses. Journal of Biosystems Engineering , 23:18-27. ; Villagrán et al., 2019Villagrán EA, Baeza EJ & Bojacá CR (2019) Transient CFD analysis of the natural ventilation of three types of greenhouses used for agricultural production in a tropical mountain climate. Biosystems Engineering , 188:288-304. ). The benefits sought with the implementation of the crop under cover are; increases in crop yields, increase in the final quality of the harvested product, reduction of water and fertilizer consumption, reduction of pesticides and ensure agricultural production throughout the year (Pakari & Ghani, 2019aPakari A & Ghani S (2019a) Evaluation of a novel greenhouse design for reduced cooling loads during the hot season in subtropical regions. Solar Energy , 181:234-242. ). Passive greenhouses are characterized by the lack of climate control equipment for tasks such as cooling and heating, therefore, this type of greenhouse is considered low cost and low environmental impact by not requiring energy from non-renewable sources for its operation (Graamans et al., 2018Graamans L, Baeza E, Van Den Dobbelsteen A, Tsafaras I & Stanghellini C (2018) Plant factories versus greenhouses: Comparison of resource use efficiency. Agricultural Systems, 160:31-43.).

The management of the microclimate in passive greenhouses is carried out by opening and closing ventilation areas on the sides and roof of the greenhouse, a process known as natural ventilation. From this management of the ventilation areas, air flow movements are generated from physical phenomena such as natural convection by buoyancy or thermal effect and by differences in pressure between the external and internal environment known as wind effect (Bournet & Boulard, 2010Bournet PE & Boulard T (2010) Effect of ventilator configuration on the distributed climate of greenhouses: A review of experimental and CFD studies. Computers and Electronics in Agriculture , 74:195-217.; Espinoza et al., 2017Espinoza K, López A, Valera DL, Molina-Aiz FD, Torres JA & Pena A (2017) Effects of ventilator configuration on the flow pattern of a naturally-ventilated three-span Mediterranean greenhouse. Biosystems Engineering , 164:13-30. ). Through the natural ventilation phenomenon, an air exchange is induced between the external and internal environment of the greenhouse. This exchange allows the regulation of the thermal and humidity excesses in the internal environment of the greenhouse and it is also the only source of carbon enrichment in passive greenhouses (Singh et al., 2018Singh MC, Singh JP & Singh KG (2018) Development of a microclimate model for prediction of temperatures inside a naturally ventilated greenhouse under cucumber crop in soilless media. Computers and Electronics in Agriculture , 154:227-238. ).

The efficiency of natural ventilation depends on many factors such as: the geometry and size of the greenhouse, the area of the ventilation surfaces, the speed and direction of the outside wind, the thermal gradient between the indoor and outdoor environment, as well as the presence or not of insect screens also play an important role in the behavior of the airflow patterns (Baeza et al., 2009Baeza EJ, Pérez-Parra JJ, Montero JI, Bailey BJ, López JC & Gázquez JC (2009) Analysis of the role of sidewall vents on buoyancy-driven natural ventilation in parral-type greenhouses with and without insect screens using computational fluid dynamics. Biosystems Engineering , 104:86-96.). Deficient natural ventilation rates are mainly characterized by inadequate airflow patterns within the greenhouses, thus generating microclimatic conditions that cause stress conditions in the plants that affect their growth and development, these stress conditions are usually more critical in hot climate regions (Molina-Aiz et al., 2017Molina-Aiz FD, Norton T, López A, Reyes-Rosas A, Moreno MA, Marín P, Espinoza K & Valera DL (2017) Using computational fluid dynamics to analyse the CO2 transfer in naturally ventilated greenhouses. Acta Horticulturae , 1182:283-292. ).

Currently there is a need to seek strategies to improve the airflow patterns of passive greenhouses and the microclimate generated inside them using different renewable energy sources. A little explored alternative is the use of wind energy by coupling aeration towers to the sides of the greenhouse, these towers have the ability to generate air flow movements by taking advantage of the pressure differences that are created between the windward and leeward sides (Pakari & Ghani, 2019bPakari A & Ghani S (2019b) Airflow assessment in a naturally ventilated greenhouse equipped with wind towers: numerical simulation and wind tunnel experiments. Energy and Buildings , 199:1-11. ). A technique for the study and optimization of air flow patterns inside greenhouses is the numerical simulation by computational fluid dynamics (CFD), this is a mature and robust technique with which it is possible to evaluate different alternatives in a virtual scenario of engineering problems that include transport phenomena and fluid movements (Dhiman et al., 2019Dhiman M, Sethi VP, Singh B & Sharma A (2019) CFD analysis of greenhouse heating using flue gas and hot water heat sink pipe networks. Computers and Electronics in Agriculture , 163:104853.; Mesmoudi et al., 2017Mesmoudi K, Meguallati KH & Bournet PE (2017) Effect of the greenhouse design on the thermal behavior and microclimate distribution in greenhouses installed under semi‐arid climate. Heat Transfer Asian Research, 46:1294-1311. ).

The use of wind towers is not widespread in agricultural structures, in a recent study developed by Pakari & Ghani (2019bPakari A & Ghani S (2019b) Airflow assessment in a naturally ventilated greenhouse equipped with wind towers: numerical simulation and wind tunnel experiments. Energy and Buildings , 199:1-11. ), the authors analyzed by means of CFD and an experimental validation in a wind tunnel the effect of a wind capture tower on the flow patterns inside a greenhouse type tunnel of 81 m2. This study only considered the wind effect of natural ventilation and the authors reported air flows with speeds inside the tunnel that varied between 0.41 and 1.81 m s-1, for simulation scenarios with outside wind speeds between 1 and 5 m s-1. The objective of this research was to evaluate, using an experimentally validated 2D CFD model, the effect that the implementation of an air capture tower in each side wall of the greenhouse would have on air flow patterns and thermal distribution. The numerical model considered the thermal and wind effect of the natural ventilation phenomenon.

MATERIALS AND METHODS

Description of the greenhouse

The experiment was conducted in a naturally ventilated flat roof chapel type greenhouse (PG), built of structural steel and covered with polyethylene, located in the Colombian Caribbean region in the municipality of Seville, department of Magdalena, at the Caribbean Research Center of the Colombian Agricultural Research Corporation - AGROSAVIA. The dimensions of the greenhouse were 20 m in cross section and 25 m in length, which is equivalent to a covered area of 500 m2. The greenhouse was equipped with side and roof vents, these vents have an insect proof mesh (Figure 1). This greenhouse model already built at full scale was used to carry out the comparisons of air flow and thermal distribution with the possible scenario of a greenhouse equipped with air capture towers (MPG). The capture and recording of experimental data will also be carried out on PG for the purpose of validating the CFD model.

Figure 1:
A) Real prototype, B) General scheme of the PG greenhouse.

The region of study presents climatological conditions where the average of the multiannual temperature for a period of 30 years is 28.16 °C, with a maximum and minimum average of 32.8 and 23.2 °C, respectively, the relative humidity presented an average behavior with values over 65% and an annual precipitation with average values of 1245.1 mm, the dominant wind speed values in the region of study vary between 0.5 and 3 m s-1, with a dominant direction of in the E-W direction, which is perpendicular to the longitudinal axis and side walls of the greenhouse.

Description of air capture towers

The air capture towers proposed in this research should be attached to each of the lateral sides of the greenhouse studied (Figure 2B). The towers can be built in the same structural and covering material in which the greenhouse is manufactured, in this case structural steel and polyethylene covering. The overall dimensions of the towers are 10 m and 9.5 m for maximum and minimum height, the width of the tower is 2.5 m, the length should be similar to the side length of the greenhouse in this case 20 m and at the top of the tower an area should be generated for air inlet into the greenhouse with a width of 3.5 m (Figure 2A).

Figure 2:
A) Air tower description, B) Coupling of the air towers to the greenhouse.

Numerical model

The non-linear partial differential equations known as Navier Stokes (RANS) averaged by Reynolds that govern the amount of energy, momentum and mass of a steady state fluid in a two-dimensional field can be described as follows:

u i x i = 0 (1)

ρ x j u i u j = - p x i + τ i j x j ρ g i (2)

ρ x j u i h = x j K T x i + P T + u i P x i + τ i j u i x i (3)

Where ρ is the air density (kg m-3), P is the air pressure (Pa), g i is the force of gravity (m s-2), K is the thermal conductivity of the air (W m-1 K-1), ui y uj are the components of speed (m s-1) y τij is Reynolds' stress tensor (N).

The tubrulence was incorporated into the numerical model through the standard empirical k -ε model, a model based on the transport equations that solve kinetic turbulent energy k and the dispair of this energy per unit volume ε. This model has been the most used and widely validated in greenhouse airflow studies showing to be efficient with the use of computational resources and providing realistic solutions (Mesmoudi et al., 2017Mesmoudi K, Meguallati KH & Bournet PE (2017) Effect of the greenhouse design on the thermal behavior and microclimate distribution in greenhouses installed under semi‐arid climate. Heat Transfer Asian Research, 46:1294-1311. ). The transport equations for k and ε can be modeled as:

x ρ k = x j μ + k x j k x j + G k + G b - ρ ϵ - Y M (4)

t ρ ε = x i ( μ + μ t σ ) ϵ x i + ρ C 1 S ϵ - ρ C 2 ϵ 2 k + v ϵ + C 1 ϵ ϵ k C 3 ϵ G b k (5)

Where μ is viscosity and μt is turbulent viscosity (kg m-1 s-1), G b is turbulent kinetic energy generation due to buoyancy, G k is the generation of turbulent kinetic energy due to speed gradients, σk y σϵ are Prandtl's turbulent numbers for k and ε, v is the coefficient of kinematic viscosity, YM is the fluctuating expansion in turbulence due to the overall dissipation rate and C1ϵ, C2ϵ, Cμ, σk y σϵ are constant with empirically determined values and set by default in the simulation software. Buoyancy forces due to differences in air density are added as a source term to the impulse equation through the Boussinesq approach.

The presence of anti-insect screens was modelled by using equations derived from the flow of a free and forced fluid through porous materials, taking into account their main characteristics of porosity and permeability (Valera et al., 2005 Valera DL, Molina FD, Álvarez AJ, López JA, Terrés-Nicoli JM & Madueño A (2005) Contribution to characterisation of insect-proof screens: Experimental measurements in wind tunnel and CFD simulation. Acta Horticulturae , 691:441-448. ). These equations can be derived from the Forchheimer equation:

p x = μ K u + ρ C f K u u (6)

Where u is the speed of air (m s-1); μ is the dynamic viscosity of the fluid (kg m-1 s-1), K is the permeability of the medium (m2); Cf is the inertial factor of the porous mesh; ρ is the air density (kg m-3) and ∂x the thickness of the porous material (m). In our research we use a two-dimensional modeling approach, this is valid and generally reliable results are obtained for cases where there are dominant wind directions and in regions where the greenhouses establish their orientation under this concept (Villagrán et al., 2019Villagrán EA, Baeza EJ & Bojacá CR (2019) Transient CFD analysis of the natural ventilation of three types of greenhouses used for agricultural production in a tropical mountain climate. Biosystems Engineering , 188:288-304. ).

Construction of the computer domain and meshing process

This type of research involving transport phenomena, where the final objective is to analyze the phenomenon of natural ventilation in the middle section of a greenhouse structure equipped with side openings. It is possible to implement a two-dimensional simulation model that allows to obtain results in a shorter period of time than in a three-dimensional simulation model (Baxevanou et al., 2010Baxevanou C, Fidaros D, Bartzanas T & Kittas C (2010) Numerical simulation of solar radiation, air flow and temperature distribution in a naturally ventilated tunnel greenhouse. Agricultural Engineering International: CIGR Journal, 12:48-67.; Benni et al., 2016Benni S, Tassinari P, Bonora F, Barbaresi A & Torreggiani D (2016) Efficacy of greenhouse natural ventilation: Environmental monitoring and CFD simulations of a study case. Energy and Buildings, 125:276-286. ). The 2D approach also allows to obtain a saving of the computational resources that are consumed in the process of development of the model, meshing and numerical simulation (Mesmoudi et al., 2017Mesmoudi K, Meguallati KH & Bournet PE (2017) Effect of the greenhouse design on the thermal behavior and microclimate distribution in greenhouses installed under semi‐arid climate. Heat Transfer Asian Research, 46:1294-1311. ). Finally, through the two-dimensional models, precise and reliable solutions can be obtained when the fluid flow is perpendicular to the ventilation sections under study (Bartzanas et al., 2004Bartzanas T, Boulard T & Kittas C (2004) Effect of Vent Arrangement on Windward Ventilation of a Tunnel Greenhouse. Biosystems Engineering , 88:479-490.: Villagrán & Bojacá, 2019bVillagrán EA & Bojacá CR (2019b) Study of natural ventilation in a Gothic multi-tunnel greenhouse designed to produce rose (Rosa spp.) in the high-Andean tropic. Ornamental Horticulture, 25:133-143.).

For pre-processing stage of the CFD-RANS simulation, it is recommended to follow guidelines for the construction of the computational domain in engineering problems involving air movement and its interaction with buildings, such as those proposed by Blocken (2015Blocken B (2015) Computational Fluid Dynamics for urban physics: Importance, scales, possibilities, limitations and ten tips and tricks towards accurate and reliable simulations. Building and Environment, 91:219-245. ). Where it is established that the entrance and upper limit of the domain must have a minimum separation with the building of 5H, while the exit limit must have a minimum distance of 10H with the building, where H is the maximum height of the building under analysis. In our case, this computational domain has dimensions of 70 m (y-axis) and 243 m (x-axis) (Figure 3).

Figure 3:
Computer domains, A) PG and B) MPG.

The meshing process must be of high quality in order to ensure high quality results, independent of mesh size and without convergence problems (Tominaga et al., 2008Tominaga Y, Mochida A, Yoshie R, Kataoka H, Nozu T, Yoshikawa M & Shirasawa T (2008) AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings. Journal of wind engineering and industrial aerodynamics , 96:1749-1761.). The computational domain was divided into an unstructured mesh of 520,183 and 561,235 square elements for PG and MPG respectively (Figure 4).

Figure 4:
Meshing detail, A) PG and B) MPG.

This mesh resolution was defined after developing a sensitivity analysis of 8 squares with different sizes, which allowed to verify the independence of the numerical solution to the mesh size (Figure 5). The quality of the mesh was evaluated by means of 2X2 determinant and the orthogonality criterion, where for the first one values were obtained for 99.8% of the cells between 0.95 and 1 and for the second criterion a minimum value of 0.94 results that are considered of high quality (Reynafarje et al., 2020Reynafarje X, Villagrán EA, Bojacá CR, Gil R & Schrevens E (2020) Simulation and validation of the airflow inside a naturally ventilated greenhouse designed for tropical conditions. Acta Horticulturae , 1271:55-62. ).

Figure 5:
Mesh size independence test.

Numerical simulation and boundary conditions

In the upper part of the computer domain a limit condition of symmetry was established, the floor, the air intake towers and the walls of the greenhouse the limit condition established was that of an enhanced wall. The ventilation areas of the greenhouse with porous meshes for protection against insects were treated as porous media, the air inlets and outlets in the intake towers were treated with the limit condition of the interior, the flow output of the computational domain was set to the pressure output condition.

While the air intake side was set by a user-defined function (UDF) to a logarithmic pattern profile for air velocity, where vertical air movement profile parameters and turbulence conditions are set, this profile was generated following the procedure established by Hargreaves & Wright (2007Hargreaves DM & Wright NG (2007) On the use of the k-ε model in commercial CFD software to model the neutral atmospheric boundary layer. Journal of wind engineering and industrial aerodynamics, 95:355-369.). For each material considered in the computational domain such as; air, polyethylene, soil, porous screen, physical, optical and aerodynamic properties were established in the case of the porous screen, the values of these properties were previously established by Flores-Velazquez et al. (2013Flores-Velázquez J, Guerrero FV, Lopez IL, Montero JI & Piscia D (2013). 3-Dimensional thermal analysis of a screenhouse with plane and multispan roof by using computational fluid dynamics (CFD). Acta Horticulturae, 1008:151-158. ) and Villagrán et al. (2019Villagrán E, Ramirez R, Rodriguez A, Pacheco RL & Jaramillo J (2020) Simulation of the Thermal and Aerodynamic Behavior of an Established Screenhouse under Warm Tropical Climate Conditions: A Numerical Approach. International Journal of Sustainable Development and Planning, 15:487-499; 2020) (Table 1).

Table 1:
Properties of materials used in the CFD simulation

As the objective of the work is to determine the effect on the ventilation rates and the thermal behavior inside the greenhouse due to the possible implementation of air capture towers, the numerical model does not consider either the presence of plants, nor was the phenomenon of solar radiation simulated with any of the available simulation models. For this last case and as a valid simplification a condition of heat flow dependent on the level of solar radiation was established as it was done in the work recently developed by Flores-Velázquez & Vega-García (2019Flores-Velázquez J & Vega-García M (2019) Regional management of the environment in a zenith greenhouse with computational fluid dynamics (CFD). Ingeniería Agrícola y Biosistemas, 11:3-20. ) and by Villagrán & Bojaca (2019cVillagrán EA & Bojacá CR (2019c) CFD Simulation of the Increase of the Roof Ventilation Area in a Traditional Colombian Greenhouse: Effect on Air Flow Patterns and Thermal Behavior. International Journal of Heat and Technology, 37:881-892. ). The numerical simulations were developed in steady state with a pressure-based, segregated solver and an implicit formulation for the linearization of the discretized equations by second order schemes, the convergence criteria according to the absolute residues for the equations of momentum, turbulence, mass and energy were established in 10-6 (Bouhoun Ali et al., 2017Bouhoun AH, Bournet PE, Cannavo P & Chantoiseau E (2018) Development of a CFD crop submodel for simulating microclimate and transpiration of ornamental plants grown in a greenhouse under water restriction. Computers and Electronics in Agriculture, 149:26-40.).

Validation of the CFD model

To validate the model, an experimental process was developed that included the recording of climatic variables in the greenhouse's external environment, such as temperature, air humidity, wind speed and direction, and solar radiation, by means of a weather station Davis-Vantage 2 plus 6162 (Davis Instruments, Hayward, CA, EE. UU.). Inside the greenhouse on the cross section (x-axis), at a height of 1.5 m above ground level (y-axis), 5 micro weather stations of the series WatchDog 1000 (Spectrum Technologies, Aurora, IL), which were used to record and store the temperature values during the days between 1 November and 30 December 2019, the frequency of measurement and recording was 10 minutes both inside and outside the greenhouse.

Regarding the variable recorded inside the greenhouse for the validation process, it should be mentioned that it was defined from the available monitoring equipment, establishing temperature prediction as a parameter for evaluating the simulation efficiency of the CFD model. Additionally, for this case where no crops are present the results obtained from the CFD are a combination of the relationship between flow distribution patterns and temperature distribution. Therefore, temperature is an indirect measurement variable that allows us to have an idea of how close the numerical solution of the CFD model is to the real aerodynamic behavior of the structure (Villagrán & Bojacá, 2019aVillagrán EA & Bojacá CR (2019a) Effects of surrounding objects on the thermal performance of passively ventilated greenhouses. Journal of Agricultural Engineering, 50:20-27.).

The data obtained during the measurement period were analyzed, selecting those of the hour 12. Which presented average values for the outdoor environment; 33.6 ± 0.67 °C for the outdoor temperature, 695.9 ± 23.5 W m-2 for solar radiation and 1.56 ± 0.26 m s-1 for wind speed with a predominant direction to the west (W). This information was used to carry out a simulation establishing these parameters as initial conditions.

Once the simulation was completed, the post-process was carried out by extracting the data on air temperature inside the greenhouse at the x-points, which coincided with the internal sampling points. The data obtained through simulation and experimentation were compared through the calculation of the mean absolute error (MAE) and the root mean square error (RMSE).

M A E = 1 n j = 1 n T m j - T s j (7)

R M S E = j = 1 n T m j - T m j 2 ) n (8)

where Tmj and Tsj, are the value of the measured and simulated temperature respectively and n is the number of data compared. .

Scenarios considered for simulation

Once the numerical model was validated and its adequate prediction of natural ventilation and thermal behavior in the PG greenhouse was verified, this model was used to develop the simulations for two specific scenarios, the PG and MPG greenhouses, evaluated with 4 outdoor wind speeds (Table 2). The initial conditions corresponded to the maximum values recorded in the study area for both temperature and solar radiation of 34.8 °C and 860 W m-2, respectively, and were kept constant in each simulated scenario.

Table 2:
Simulation scenarios developed

RESULTS AND DISCUSSION

Validation of the CFD model

The calculation of the evaluated goodness-of-fit parameters for the simulated and measured temperature at the observation points inside PG showed values of 0.31 and 0.34 °C for MAE and RMSE respectively. Likewise, the qualitative behavior observed when graphing the spatial trend of the behavior of the simulated and measured data in the transversal axis of the greenhouse (x-axis), allows confirming that the CFD model has a high capacity to satisfactorily predict the trend of the thermal behavior inside PG, therefore, its use for the objective of this investigation is valid (Figure 6).

Figure 6:
Spatial trend of measured and simulated temperature data.

These results, where the difference between experimental and simulated data is less than 1 °C, are similar to those found in several CFD studies of natural ventilation in passive greenhouses such as those developed by He et al. (2015He KS, Chen DY, Sun LJ, Liu ZL & Huang ZY (2015) The effect of vent openings on the microclimate inside multi-span greenhouses during summer and winter seasons. Engineering Applications of Computational Fluid Mechanics, 9:399-410., 2018He X, Wang J, Guo S, Zhang J, Wei B, Sun J & Shu S (2018) Ventilation optimization of solar greenhouse with removable back walls based on CFD. Computers and Electronics in Agriculture , 149:16-25.) and Villagrán & Bojacá (2019bVillagrán EA & Bojacá CR (2019b) Study of natural ventilation in a Gothic multi-tunnel greenhouse designed to produce rose (Rosa spp.) in the high-Andean tropic. Ornamental Horticulture, 25:133-143.).

Air flow patterns

The airflow patterns inside PG and MPG will be influenced by the natural convection inside the greenhouse and the effect generated by the wind and the wind speed from the outside environment. The airflow patterns simulated for PG show two characteristic behaviors, the first one occurs for the S1 scenario which can be considered as a low outdoor wind speed scenario, under these conditions it is possible to observe an airflow entering the greenhouse through the lower windward side area and inside PG it generates two flow movements, one of horizontal type and parallel to the airflow movement outside, this flow is shown in direction and exit through the lower leeward side, the other flow is of convective type appears over the upper central part and between this region and the cover of PG, this is generated by the movement of warm, lower density air that occurs floating from the floor of the greenhouse to the roof region (López et al., 2011López A, Valera DL & Molina-Aiz FD (2011) Sonic anemometry to measure natural ventilation in greenhouses. Sensors, 11:9820-9838. ), Some of this air flow exits the structure through the roof ventilation areas (Figure 7).

Figure 7:
Simulated airflow patterns (ms-1) for PG and MPG.

For PG scenarios S2, S3 and S4 the same flow pattern is observed with different speed due to the speed of the outside air in the simulated case, air movement for PG under this scenario shows inflow through the windward side and roof ventilation areas to the leeward side ventilation areas where they eventually exit to the outside (Figure 7).

For the simulated MPG scenarios, the effects of the air collection towers on the flow pattern inside the structure are observed (Figure 7). It identifies a pattern of flow that enters the greenhouse through the ventilation tower, this airflow is accelerated and directed towards the ground and then enter MPG and move horizontally over the area where the crops are established, it is also observed that as air flow inside MPG suffers a slowdown, these results are consistent with those reported in the study developed por Li & Mak (2007Li L & Mak CM (2007) The assessment of the performance of a windcatcher system using computational fluid dynamics. Building and Environment , 42:1135-1141. ) and Pakari & Ghani. (2019bPakari A & Ghani S (2019b) Airflow assessment in a naturally ventilated greenhouse equipped with wind towers: numerical simulation and wind tunnel experiments. Energy and Buildings , 199:1-11. ).

In the case of low velocity it is observed that the flow pattern leaves the greenhouse through the leeward side ventilation tower and the ventilation areas located in the roof area of the greenhouse, on the contrary for the remaining scenarios it is observed that the airflow entering from the windward side collides with an airflow entering from the leeward tower causing two convective cells of different size and exiting the greenhouse through the roof ventilation areas (Figure 7). These airflow patterns differ from those reported by Pakari & Ghani. (2019bPakari A & Ghani S (2019b) Airflow assessment in a naturally ventilated greenhouse equipped with wind towers: numerical simulation and wind tunnel experiments. Energy and Buildings , 199:1-11. ). This can be generated by the buoyancy effects and the presence of anti-insect nets considered in our study.

The quantitative behavior of the air movement was made through the calculation of the mean speed (MV) and the normalized speed (NV) for two heights above ground level 1 and 2 meters, this parameter is the relation of the speed of the internal air flow with the speed of the external wind (Table 3). MV values for PG ranged from 0.27 ± 0.05 to 0.54 ± 0.22 m s-1 for the 1 m height, while for the 2 m height these values were 0.22 ± 0.06 and 0.66 ± 0.35 m s-1 characteristic velocities in side-ventilated and roof-ventilated passive greenhouses (Teitel et al., 2006Teitel M, Liran O, Barak M & Tanny J (2006). Air velocities in a naturally ventilated greenhouse. Acta Horticulturae , 719:189-196 ).

Table 3:
Calculated airflow pattern parameters

On the other hand, for MPG the values of MV were 0.34 ± 0.09 and 1.31 ± 0.39 m s-1 for the height of 1 meter, which represents an increase of 25.9 and 142.5% compared to PG, for the 2 meter height the MV values were 0.13 ± 0.09 and 0.78 ± 0.39 m s-1 which compared to PG are 40.4% lower for S1 and 18.1% higher for S4.

In general it can be mentioned that for MPG the indoor air flows have a higher velocity compared to PG and this is demonstrated by the VN value obtained in the cross section of the greenhouse at each of the two heights evaluated (Figure 8). Additionally, it is possible that the VN value in MPG presents a greater variation along the transversal axis and between heights analyzed, this is generated by the convective type movements that are presented in this MPG (Figure 7).

Figure 8:
Normalized velocity patterns calculated for PG and MPG.

The VN values show a reduction in airflow velocity compared to outdoor velocity of 82.3 and 79.6% for the most critical case in PG and MPG respectively, while the lowest reduction was 53.9 and 44.2% for PG and MPG, this difference in speed between the exterior and interior flow of the greenhouses is caused by the presence of the insect protection meshes, which generate a restriction to the movement of air towards the interior of the greenhouse, the values obtained in PG are similar to those reported by Baeza et al. (2009Baeza EJ, Pérez-Parra JJ, Montero JI, Bailey BJ, López JC & Gázquez JC (2009) Analysis of the role of sidewall vents on buoyancy-driven natural ventilation in parral-type greenhouses with and without insect screens using computational fluid dynamics. Biosystems Engineering , 104:86-96.) in a natural ventilation study developed in a greenhouse equipped with anti-insect screens.

Indexes of hourly renewal

The air exchange rate of a naturally ventilated structure is a parameter that allows measuring the efficiency of the ventilation system, this rate is defined as the relationship between the volumetric rate of air flow exiting the structure and the volume of the structure, this value was calculated by integration method mass flow rate (Senhaji et al., 2019Senhaji A, Mouqallid M & Majdoubi H (2019) CFD assisted study of multi-chapels greenhouse vents openings effect on inside airflow circulation and microclimate patterns. Open Journal of Fluid Dynamics, 9:119-139.; Villagrán et al., 2019Villagrán EA, Baeza EJ & Bojacá CR (2019) Transient CFD analysis of the natural ventilation of three types of greenhouses used for agricultural production in a tropical mountain climate. Biosystems Engineering , 188:288-304. ).

The results found allow us to verify that the air renewal in the MPG greenhouse has a higher value than that of PG (Figure 9). The values for PG ranged from 20.1 to 74.9 vol h-1, while those for MPG were 31.7 and 107.5 for S1 and S4 respectively, The renewal rate in MPG is 57.3 and 43.4% higher than PG for these two cases. In the case of MPG it can be said that for speeds ≥ at 1 ms-1 the renewal rates are above the minimum value recommended for naturally ventilated greenhouses which is 45 vol h-1, value that allows to regulate the temperature and relative humidity conditions inside the greenhouse (ASHRAE, 2009ASHRAE (2009) ASHRAE Handbook. Atlanta, Fundamentals. 1000p.; Villagrán et al., 2012Villagrán EA, Gil R, Acuña JF & Bojacá CR (2012) Optimization of ventilation and its effect on the microclimate of a colombian multispan greenhouse. Agronomía Colombiana, 30:282-288.).

Figure 9:
Renewal indexes calculated for each simulated scenario.

Thermal behaviour

The spatial distribution patterns inside PG and MPG, allowed to observe the differentiated behavior that exists between greenhouses, which allowed to verify the benefits obtained from the implementation of the ventilation towers. In MPG, by obtaining higher renewal rates and better airflow movement, an additional thermal distribution of lower magnitude and more homogeneous compared to PG is obtained (Figure 10). This is a relevant result since sometimes a higher ventilation rate does not necessarily generate a reduction of the temperature value inside the structure and a greater homogeneity, this happens when the optimization strategies of natural ventilation do not generate adequate air flows inside the greenhouse, especially in the area where the crop will be established (Sase, 2006Sase S (2006) Air movement and climate uniformity in ventilated greenhouses. Acta Horticulturae , 719:313-323.; Senhaji et al., 2019Senhaji A, Mouqallid M & Majdoubi H (2019) CFD assisted study of multi-chapels greenhouse vents openings effect on inside airflow circulation and microclimate patterns. Open Journal of Fluid Dynamics, 9:119-139.).

Figure 10:
Spatial temperature distribution patterns (°C) for each simulated scenario.

The average values of temperature (MT) and thermal differential between outside and inside (ΔTm) were calculated for each of the simulated scenarios and for the two heights analyzed (Table 4). The MT value obtained for PG ranges from 36.3 ± 0.6 to 37.1 ± 1.1 °C, giving values of ΔTm of 1.5 ± 0.6 and 2.3 ± 1.1 °C respectively. On the other hand, for MPG the MV value varies between 35.0 ± 0.2 and 35.9 ± 0.3 which gives values of ΔTm 0.2 ± 0.2 and 1.0 ± 1.5 °C.

Table 4:
Thermal evaluation parameters calculated for each simulated scenario

Likewise, the standard deviation values of the parameters evaluated show us that the spatial behavior of the temperature in this greenhouse is more homogeneous, a factor that is undoubtedly key in the management of the microclimate since this variable intervenes in the physiological and biological processes of the plants and any heterogeneous distribution will directly influence the uniformity in the growth of the crops, which affects the quality of the final product obtained (Ma et al., 2019 aMa D, Carpenter N, Amatya S, Maki H, Wang L, Zhang L & Jin J (2019a) Removal of greenhouse microclimate heterogeneity with conveyor system for indoor phenotyping. Computers and Electronics in Agriculture , 166:104979. ,bMa D, Carpenter N, Maki H, Rehman TU, Tuinstra MR & Jin J (2019b) Greenhouse environment modeling and simulation for microclimate control. Computers and Electronics in Agriculture , 162:134-142.).

Additionally, to analyze the spatial distribution of the thermal differential (ΔT), it was plotted for all simulated scenarios, in a cross-sectional profile of the greenhouse (Figure 11). For MPG it can be seen that the distribution of ΔT is very uniform in the profiles analyzed, in the case of the scenario S1 it is observed as a large part of the transversal profile (0-15 m) presents a ΔT of approximately 1.0 °C, while for the scenarios S2, S3 and S4 the value of ΔT shows values lower than 0.8 °C in a large part of the transversal axis of the greenhouse with the exception of a region between 12.5 and 15 m, this region is the one influenced by the two convective cells analyzed in the air flow patterns (Figure 7).

Figure 11:
Thermal differential distribution patterns calculated for each simulated scenario.

On the contrary, for scenario S1 of PG the greatest heterogeneity found in this study is observed where the value of ΔT reaches over 4 °C in a region of the greenhouse, on the other hand, for S2, S3 and S4 it is observed that ΔT can reach values of 2.8, 3.0 and 2.5 °C respectively (Figure 11). The greater homogeneity of the temperature in MPG can be explained by the convective-type airflow patterns, which usually generate a better air mixture that if complemented by adequate ventilation areas generate homogeneous thermal conditions (Mesmoudi et al., 2017Mesmoudi K, Meguallati KH & Bournet PE (2017) Effect of the greenhouse design on the thermal behavior and microclimate distribution in greenhouses installed under semi‐arid climate. Heat Transfer Asian Research, 46:1294-1311. ).

CONCLUSIONS

The implementation of ventilation towers proved to be an interesting alternative for the optimization of the natural ventilation of passive greenhouses. This microclimatic optimization alternative can be applied to the various models of passive greenhouses used in tropical countries.

Air flow patterns in Colombian greenhouses equipped with side air capture towers showed higher velocity and convective type movement which together generate ventilation rates of up to 57.3% compared to the standard greenhouse. The greenhouse with ventilation towers showed a highly homogeneous thermal behavior with thermal differentials between inside and outside below 1.1 °C.

Under the methodological approach presented in this work, future research can be proposed to evaluate the behavior of natural ventilation in this same greenhouse prototype with the presence of crops of commercial interest such as; tomatoes, cucumbers and paprika. To study the combined effect of natural ventilation together with evaporative cooling strategies. This methodology can be applied to other types of established greenhouses in various climatic conditions. Finally, it would also be interesting to reinforce the validation method by means of a sonic anemometry or hot-wire analysis, or in its absence by a study in the wind tunnel.

ACKNOWLEDGEMENTS, FINANCIAL SUPPORT AND FULL DISCLOSURE

The authors are grateful to the Colombian Agricultural Research Corporation - AGROSAVIA for technical and administrative support in this study and to the Regional Fund for Agricultural Technology (FONTAGRO) for funding research entitled Innovations for horticulture in protected environments in tropical zones: option for sustainable intensification of family agriculture in the context of climate change in LAC. The opinions expressed in this publication are solely those of the authors and do not necessarily reflect the views of FONTAGRO, its Board of Directors, the Bank, its sponsoring institutions, or the countries it represents. The authors declare that there is no conflict of interesting carrying this research and publishing this manuscript.

REFERENCES

  • Akrami M, Javadi AA, Hassanein MJ, Farmani R, Dibaj M, Tabor GR & Negm A (2020) Study of the Effects of Vent Configuration on Mono-Span Greenhouse Ventilation Using Computational Fluid Dynamics. Sustainability, 12:986-998.
  • ASHRAE (2009) ASHRAE Handbook. Atlanta, Fundamentals. 1000p.
  • Baeza E, Hemming S & Stanghellini C (2020) Materials with switchable radiometric properties: Could they become the perfect greenhouse cover? Biosystems Engineering, 193:157-173.
  • Baeza EJ, Pérez-Parra JJ, Montero JI, Bailey BJ, López JC & Gázquez JC (2009) Analysis of the role of sidewall vents on buoyancy-driven natural ventilation in parral-type greenhouses with and without insect screens using computational fluid dynamics. Biosystems Engineering , 104:86-96.
  • Bartzanas T, Boulard T & Kittas C (2004) Effect of Vent Arrangement on Windward Ventilation of a Tunnel Greenhouse. Biosystems Engineering , 88:479-490.
  • Baxevanou C, Fidaros D, Bartzanas T & Kittas C (2010) Numerical simulation of solar radiation, air flow and temperature distribution in a naturally ventilated tunnel greenhouse. Agricultural Engineering International: CIGR Journal, 12:48-67.
  • Benni S, Tassinari P, Bonora F, Barbaresi A & Torreggiani D (2016) Efficacy of greenhouse natural ventilation: Environmental monitoring and CFD simulations of a study case. Energy and Buildings, 125:276-286.
  • Blocken B (2015) Computational Fluid Dynamics for urban physics: Importance, scales, possibilities, limitations and ten tips and tricks towards accurate and reliable simulations. Building and Environment, 91:219-245.
  • Bouhoun AH, Bournet PE, Cannavo P & Chantoiseau E (2018) Development of a CFD crop submodel for simulating microclimate and transpiration of ornamental plants grown in a greenhouse under water restriction. Computers and Electronics in Agriculture, 149:26-40.
  • Bournet PE & Boulard T (2010) Effect of ventilator configuration on the distributed climate of greenhouses: A review of experimental and CFD studies. Computers and Electronics in Agriculture , 74:195-217.
  • Dhiman M, Sethi VP, Singh B & Sharma A (2019) CFD analysis of greenhouse heating using flue gas and hot water heat sink pipe networks. Computers and Electronics in Agriculture , 163:104853.
  • Espinoza K, López A, Valera DL, Molina-Aiz FD, Torres JA & Pena A (2017) Effects of ventilator configuration on the flow pattern of a naturally-ventilated three-span Mediterranean greenhouse. Biosystems Engineering , 164:13-30.
  • Ezzaeri K, Fatnassi H, Wifaya A, Bazgaou A, Aharoune A, Poncet C & Bouirden L (2020) Performance of photovoltaic canarian greenhouse: A comparison study between summer and winter seasons. Solar Energy, 198:275-282.
  • Flores-Velázquez J, Guerrero FV, Lopez IL, Montero JI & Piscia D (2013). 3-Dimensional thermal analysis of a screenhouse with plane and multispan roof by using computational fluid dynamics (CFD). Acta Horticulturae, 1008:151-158.
  • Flores-Velázquez J & Vega-García M (2019) Regional management of the environment in a zenith greenhouse with computational fluid dynamics (CFD). Ingeniería Agrícola y Biosistemas, 11:3-20.
  • Graamans L, Baeza E, Van Den Dobbelsteen A, Tsafaras I & Stanghellini C (2018) Plant factories versus greenhouses: Comparison of resource use efficiency. Agricultural Systems, 160:31-43.
  • Hargreaves DM & Wright NG (2007) On the use of the k-ε model in commercial CFD software to model the neutral atmospheric boundary layer. Journal of wind engineering and industrial aerodynamics, 95:355-369.
  • He KS, Chen DY, Sun LJ, Liu ZL & Huang ZY (2015) The effect of vent openings on the microclimate inside multi-span greenhouses during summer and winter seasons. Engineering Applications of Computational Fluid Mechanics, 9:399-410.
  • He X, Wang J, Guo S, Zhang J, Wei B, Sun J & Shu S (2018) Ventilation optimization of solar greenhouse with removable back walls based on CFD. Computers and Electronics in Agriculture , 149:16-25.
  • Li L & Mak CM (2007) The assessment of the performance of a windcatcher system using computational fluid dynamics. Building and Environment , 42:1135-1141.
  • López A, Valera DL & Molina-Aiz FD (2011) Sonic anemometry to measure natural ventilation in greenhouses. Sensors, 11:9820-9838.
  • Ma D, Carpenter N, Amatya S, Maki H, Wang L, Zhang L & Jin J (2019a) Removal of greenhouse microclimate heterogeneity with conveyor system for indoor phenotyping. Computers and Electronics in Agriculture , 166:104979.
  • Ma D, Carpenter N, Maki H, Rehman TU, Tuinstra MR & Jin J (2019b) Greenhouse environment modeling and simulation for microclimate control. Computers and Electronics in Agriculture , 162:134-142.
  • Mesmoudi K, Meguallati KH & Bournet PE (2017) Effect of the greenhouse design on the thermal behavior and microclimate distribution in greenhouses installed under semi‐arid climate. Heat Transfer Asian Research, 46:1294-1311.
  • Molina-Aiz FD, Norton T, López A, Reyes-Rosas A, Moreno MA, Marín P, Espinoza K & Valera DL (2017) Using computational fluid dynamics to analyse the CO2 transfer in naturally ventilated greenhouses. Acta Horticulturae , 1182:283-292.
  • Pakari A & Ghani S (2019a) Evaluation of a novel greenhouse design for reduced cooling loads during the hot season in subtropical regions. Solar Energy , 181:234-242.
  • Pakari A & Ghani S (2019b) Airflow assessment in a naturally ventilated greenhouse equipped with wind towers: numerical simulation and wind tunnel experiments. Energy and Buildings , 199:1-11.
  • Reynafarje X, Villagrán EA, Bojacá CR, Gil R & Schrevens E (2020) Simulation and validation of the airflow inside a naturally ventilated greenhouse designed for tropical conditions. Acta Horticulturae , 1271:55-62.
  • Sase S (2006) Air movement and climate uniformity in ventilated greenhouses. Acta Horticulturae , 719:313-323.
  • Senhaji A, Mouqallid M & Majdoubi H (2019) CFD assisted study of multi-chapels greenhouse vents openings effect on inside airflow circulation and microclimate patterns. Open Journal of Fluid Dynamics, 9:119-139.
  • Singh MC, Singh JP & Singh KG (2018) Development of a microclimate model for prediction of temperatures inside a naturally ventilated greenhouse under cucumber crop in soilless media. Computers and Electronics in Agriculture , 154:227-238.
  • Syed AM & Hachem C (2019) Review of Construction; Geometry; Heating, Ventilation, and Air-Conditioning; and Indoor Climate Requirements of Agricultural Greenhouses. Journal of Biosystems Engineering , 23:18-27.
  • Teitel M, Liran O, Barak M & Tanny J (2006). Air velocities in a naturally ventilated greenhouse. Acta Horticulturae , 719:189-196
  • Tominaga Y, Mochida A, Yoshie R, Kataoka H, Nozu T, Yoshikawa M & Shirasawa T (2008) AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings. Journal of wind engineering and industrial aerodynamics , 96:1749-1761.
  • Valera DL, Molina FD, Álvarez AJ, López JA, Terrés-Nicoli JM & Madueño A (2005) Contribution to characterisation of insect-proof screens: Experimental measurements in wind tunnel and CFD simulation. Acta Horticulturae , 691:441-448.
  • Villagrán EA, Gil R, Acuña JF & Bojacá CR (2012) Optimization of ventilation and its effect on the microclimate of a colombian multispan greenhouse. Agronomía Colombiana, 30:282-288.
  • Villagrán EA & Bojacá CR (2019a) Effects of surrounding objects on the thermal performance of passively ventilated greenhouses. Journal of Agricultural Engineering, 50:20-27.
  • Villagrán EA & Bojacá CR (2019b) Study of natural ventilation in a Gothic multi-tunnel greenhouse designed to produce rose (Rosa spp.) in the high-Andean tropic. Ornamental Horticulture, 25:133-143.
  • Villagrán EA & Bojacá CR (2019c) CFD Simulation of the Increase of the Roof Ventilation Area in a Traditional Colombian Greenhouse: Effect on Air Flow Patterns and Thermal Behavior. International Journal of Heat and Technology, 37:881-892.
  • Villagrán EA, Baeza EJ & Bojacá CR (2019) Transient CFD analysis of the natural ventilation of three types of greenhouses used for agricultural production in a tropical mountain climate. Biosystems Engineering , 188:288-304.
  • Villagrán E, Ramirez R, Rodriguez A, Pacheco RL & Jaramillo J (2020) Simulation of the Thermal and Aerodynamic Behavior of an Established Screenhouse under Warm Tropical Climate Conditions: A Numerical Approach. International Journal of Sustainable Development and Planning, 15:487-499

Publication Dates

  • Publication in this collection
    26 Feb 2021
  • Date of issue
    Jan-Feb 2021

History

  • Received
    16 Apr 2020
  • Accepted
    21 Sept 2020
Universidade Federal de Viçosa Av. Peter Henry Rolfs, s/n, 36570-000 Viçosa, Minas Gerais Brasil, Tel./Fax: (55 31) 3612-2078 - Viçosa - MG - Brazil
E-mail: ceres@ufv.br