Acessibilidade / Reportar erro

Tc-99m scan for pediatric bleeding Meckel diverticulum: a systematic review and meta-analysis

Abstract

Objective:

Meckel diverticulum (MD) is a common malformation of the digestive tract, often accompanied by serious complications. It is important to find safe and effective diagnostic methods for screening MD. The aim of this study was to evaluate the effectiveness of a technetium-99m (Tc-99m) scan for pediatric bleeding MD.

Methods:

The authors conducted a systematic review of studies published in PubMed, Embase, and Web of Science before 1 January 2023. Studies based on PICOS were included in this systematic review. The flow chart was made by PRISMA software. The quality of included studies was assessed by RevMan5 software (QUADAS-2: Quality Assessment of Diagnostic Accuracy Studies-2). The sensitivity, specificity, and other measurements of accuracy were pooled using Stata/SE 12.0 software.

Results:

Sixteen studies with 1115 children were included in this systematic review. A randomized-effects model was used for the meta-analysis because of significant heterogeneity. The combined sensitivity and specificity were 0.80 [Confidence Interval (95% CI, 0.73-0.86) and 0.95 (95% CI, 0.86-0.98)], respectively. The area under the curve (AUC) was 0.88 (95% CI, 0.85-0.90). Publication bias (Begg’s test p = 0.053) was observed.

Conclusion:

Tc-99m scan has high specificity, but moderate sensitivity, which is always influenced by some factors. Hence, the Tc-99m scan has some limitations in the diagnosis of pediatric bleeding MD.

KEYWORDS
Meckel diverticulum; Tc-99m scan; Diagnosis; Gastrointestinal tract

Introduction

Meckel diverticulum (MD) has an incidence rate of 1-3% in the population. It is an embryonic residue after incomplete closure of the umbilical mesenteric canal11 Berquist TH, NG Nolan, AdsonMA, Schutt AJ. Diagnosis of Meckel’s diverticulum by radioisotope scanning. Mayo Clin Proc. 1973;48:98–102. Only 25-40% of the cases have clinical symptoms,22 Kilpatrick ZM. Scanning in diagnosis of Meckel’s diverticulum. Hosp Practice. 1974;9:131–8. but 80% of the patients under 15 years of age have clinical symptoms.33 Lüdtke FE, Mende V, Köhler H, Lepsien G. Incidence and frequency or complications and management of Meckel’s diverticulum. Surg Gynecol Obstet. 1989;169:537-42. About 20% of MD cases have ectopic gastric mucosal (EGM) disease.44 Das PC, Rao PL, Radhakrishna K. Meckel's diverticulum in children. J Postgrad Med. 1992;38:19–20., 55 Cserni G. Gastric pathology in Meckel’s diverticulum. Review of cases resected between 1965 and 1995. Am J Clin Pathol. 1996;106:782–5. EGM is a type of pathological tissue, most often located in MD, and is the most common cause of lower gastrointestinal bleeding in children, typically before two years of age.66 Rutherford RB, Akers DR. Meckel’s diverticulum: a review of 148 pediatric patients, with special reference to the pattern of bleeding and to mesodiverticular vascular bands. Surgery. 1966;59:618–26. So early diagnosis of MD is important.

Although the diagnosis of a symptomatic MD is often difficult, Technetium-99m (Tc-99m) scanning can be performed in ectopic gastric mucosa. Approximately 90% of bleeding MDs contain heterotopic mucosa, which prompted the development of the Tc-99m scan.77 Harden R, Alexander WD. Isotope uptake and scanning of stomach in man with 99mTc-pertechnetate. Lancet. 1967;1:1305–7., 88 Jewett Jr TC, Duszynski DO, Allen JE. The visualization of Meckel’s diverticulum with 99mTc-pertechnetate. Surgery. 1970;68:567–70.

Tc-99m is helpful in the diagnosis of ectopic gastric mucosa because it compares other sites with relatively low radiographic findings.99 Jaros R, Schussheim A, Levy LM. Preoperative diagnosis of bleeding Meckel’s diverticulum utilizing 99m technetium per-technetate scinti-imaging. J Pediatr. 1973;82:45–9., 1010 Wine CR, Nahrwold DL, Waldhausen JA. Role of the technetium scan in the diagnosis of Meckel’s diverticulum. J Pediatr Surg. 1974;9:885–8., 1111 Sfakianakis GN, Conway JJ. Detection of ectopic gastric mucosa in Meckel’s diverticulum and in other aberrations by scintigraphy: I. Pathophysiology and 10-year clinical experience. J Nucl Med. 1981;22:647–54., 1212 Swaniker F, Soldes O, Hirschl RB. The utility of technetium 99m pertechnetate scintigraphy in the evaluation of patients with Meckel’s diverticulum. J Pediatr Surg. 1999;34:760–4. discussion 765., 1313 Howarth DM. The role of nuclear medicine in the detection of acute gastrointestinal bleeding. Semin Nucl Med. 2006;36: 133–46. Moreover, the Tc-99m scan is a non-invasive test with a low radiation burden and simple operation. However, specialized expertise is necessary to acquire and interpret the images, and appropriate guidelines to perform a high-quality scan have been published.1414 Ford PV, Bartold SP, Fink-Bennett DM, Jolles PR, Lull RJ, Maurer AH, Seabold JE. Procedure guideline for gastrointestinal bleeding and Meckel’s diverticulum scintigraphy. Society of Nuclear Medicine. J Nucl Med. 1999;40:1226–32. The aim of this study was to assess the utility of a Tc-99m scan in the diagnostic workup of pediatric patients with MD.

Materials and methods

This meta-analysis and systematic review were completed in accordance with the PRISMA guidelines.

Literature search

The PubMed, Embase, and Cochrane Library were searched to identify relevant studies published from inception to 1 January 2023. The search strategy consisted of the following keywords: (Meckel diverticulum) AND (Tc-99m scan). The authors contacted the original authors of the relevant studies to obtain additional information if required.

Study selection

Studies were included when the following criteria were met: (1) children; (2) Tc-99m scan was used as the test method; (3) surgical pathology examination was used as the reference standard; (4) randomized controlled trial (RCT), cohort study or case-control study.

Studies were excluded when the following criteria were met: (1) review, conference records, case reports, and animal experiments; (2) multiple studies based on the same data; (3) non-English studies.

Study screening and data extraction

Based on the inclusion and exclusion criteria, two researchers screened the literature, extracted data, and crosschecked the information. In case of discrepancies, the author of the original article was contacted for clarification. The following basic characteristics were extracted: country, experimental design, and original experimental data [the number of cases of TP (true positive), TN (true negative), FP (false positive), and FN (false negative)]. The authors defined a positive Tc-99m scan with negative results for both surgical exploration and Meckel diverticulum ultrasound as an "FP" and a negative Tc-99m scan, Meckel diverticulum ultrasound, and surgical exploration as a "TN".

Statistical analysis

Quality Assessment of Diagnostic Accuracy Studies-2 (QuadAS-2) was used to evaluate the literature quality. Statistical analysis was performed using RevMan 5.3 (Cochrane Collaboration) and Stata/SE 12.0. A random-effects model was used for the results. I2 value was used to evaluate the degree of heterogeneity. All statistical tests were two-sided, and p < 0.05 was considered statistically significant. Sensitivity analysis was used to determine the source of heterogeneity. Begg’s test was used to assess publication bias.

Results

Literature search and study selection

A total of 527 studies were initially identified using the literature search criteria. After screening for duplicates, 233 studies were excluded, while 263 studies were excluded after screening the title and abstract. Thereafter, 31 studies were selected for full-text evaluation of eligibility. Based on the study selection criteria, 12 studies were excluded. Finally, 19 studies (one prospective and 18 retrospective studies) were included. The flowchart is shown in Figure 1.

Figure 1
Flow chart of literature screening for the meta-analysis.

Characteristics of the included studies and quality assessments

The characteristics and quality assessments of the selected studies are shown in Table 1.1212 Swaniker F, Soldes O, Hirschl RB. The utility of technetium 99m pertechnetate scintigraphy in the evaluation of patients with Meckel’s diverticulum. J Pediatr Surg. 1999;34:760–4. discussion 765., 1515 Rho JH, Kim JS, Kim SY, Kim SK, Choi YM, Kim SM, et al. Clinical features of symptomatic Meckel’s diverticulum in children: comparison of scintigraphic and non-scintigraphic diagnosis. Pediatr Gastroenterol Hepatol Nutr. 2013;16:41–8. Erratum in: Pediatr Gastroenterol Hepatol Nutr. 2013;16:135. Kim, Sung Min [corrected to Kim, Seong Min]; Kim, Yoon Mi [corrected to Kim, Yun Mi]., 1616 Rerksuppaphol S, Hutson JM, Oliver MR. Ranitidine-enhanced 99mtechnetium pertechnetate imaging in children improves the sensitivity of identifying heterotopic gastric mucosa in Meckel’s diverticulum. Pediatr Surg Int. 2004;20:323–5., 1717 Chen Q, Gao Z, Zhang L, Zhang Y, Pan T, Cai D, et al. Multifaceted behavior of Meckel’s diverticulum in children. J Pediatr Surg. 2018;53:676–81., 1818 Papparella A, Nino F, Noviello C, Marte A, Parmeggiani P, Martino A, et al. Laparoscopic approach to Meckel’s diverticulum. World J Gastroenterol. 2014;20:8173–8., 1919 Shalaby RY, Soliman SM, Fawy M, Samaha A. Laparoscopic management of Meckel’s diverticulum in children. J Pediatr Surg. 2005;40:562–7., 2020 Al Janabi M, Samuel M, Kahlenberg A, Kumar S, Al-Janabi M. Symptomatic paediatric Meckel’s diverticulum: stratified diagnostic indicators and accuracy of Meckel’s scan. Nucl Med Commun. 2014;35:1162–6., 2121 Sancar S, Demirci H, Sayan A, Arʅkan A, Candar A. Meckel’s diverticulum: ten years’ experience. Ulus Cerrahi Derg. 2015;31:65–7., 2222 Leonidas JC, Germann DR. Technetium-99m pertechnetate imaging in diagnosis of Meckel’s diverticulum. Arch Dis Child. 1974;49:21–6., 2323 Cooney DR, Duszynski DO, Camboa E, Karp MP, Jewett Jr. TC. The abdominal technetium scan (a decade of experience). J Pediatr Surg. 1982;17:611–9., 2424 Gelfand MJ, Silberstein EB, Cox J. Radionuclide imaging of Meckel’s diverticulum in children. Clin Nucl Med. 1978;3:4–8., 2525 Ho JE, Konieczny KM. The sodium pertechnetate Tc 99m scan: an aid in the evaluation of gastrointestinal bleeding. Pediatrics. 1975;56:34–40., 2626 Fries M, Mortensson W, Robertson B. Technetium pertechnetate scintigraphy to detect ectopic gastric mucosa in Meckel’s diverticulum. Acta Radiol Diagn. 1984;25:417–22., 2727 Poulsen KA, Qvist N. Sodium pertechnetate scintigraphy in detection of Meckel’s diverticulum: is it usable? Eur J Pediatr Surg. 2000;10:228–31., 2828 Kong MS, Huang SC, Tzen KY, Lin JN. Repeated technetium-99m pertechnetate scanning for children with obscure gastrointestinal bleeding. J Pediatr Gastroenterol Nutr. 1994;18:284–7., 2929 Sinha CK, Pallewatte A, Easty M, De Coppi P, Pierro A, Misra D, et al. Meckel’s scan in children: a review of 183 cases referred to two paediatric surgery specialist centres over 18 years. Pediatr Surg Int. 2013;29:511–7., 3030 Dolezal J, Vizda J. Experiences with detection of the ectopic gastric mucosa by means of Tc-99m pertechnetate disodium scintigraphy in children with lower gastrointestinal bleeding. Eur J Pediatr Surg. 2008;18:258–60., 3131 Mittal BR, Kashyap R, Bhattacharya A, Singh B, Radotra BD, Narasimha Rao KL. Meckel’s diverticulum in infants and children; technetium-99m pertechnetate scintigraphy and clinical findings. Hell J Nucl Med. 2008;11:26–9., 3232 McCulleyS, Millar AJ, Mann MD, RodeH, Brown RA. The value of sodium pertechnetate Tc99m scans in the diagnosis of Meckel’s diverticulum. Pediatr Surg Int. 1996;11:240–2. A total of 1336 patients were included in the studies.

Table 1
Characteristics of the studies included in the meta-analysis.

Quality assessment

The results of the quality assessment are shown in Figure 2. The overall quality of the 19 articles was relatively high. Ten studies had both a low risk of bias and low concerns regarding applicability. Five of the included studies had high risks.

Figure 2
Quality assessment of the included studies based on QUADAS-2.

Combination of effect size

The weights of the studies of Rho JH (2013), Rerksuppaphol S (2004), and Chen Q (2018) were zero, indicating no significance of the research results, so they were excluded. A random-effects model was used due to significant heterogeneity. At last, the effect sizes of sensitivity, specificity, and summary receiver operating characteristic (SROC) were combined to conduct a meta-analysis of 16 studies, including 1115 patients. The combined sensitivity and specificity were 0.80 [Confidence Interval (95% CI, 0.73-0.86) and 0.95 (95% CI, 0.86-0.98)], respectively (Figure 3). The area under the curve (AUC) was 0.88 (95% CI, 0.85-0.90) (Figure 4).

Figure 3
The combined sensitivity and specificity of the included studies.

Figure 4
The SROC of the meta-analysis.

Heterogeneity test and subgroup after sensitivity analysis

The heterogeneity test revealed I2 = 91.3%, p = 0.000, which indicated significant heterogeneity. Subgroup analysis was conducted according to the sensitivity analysis (Figure 5).

Figure 5
The meta-analysis and subgroup according to the sensitivity analysis.

Publication bias

A funnel plot was used to determine the publication bias (Figure 6). The funnel plot was symmetric, and Begg’s test was not significant (p = 0.053), indicating no publication bias.

Figure 6
The Funnel Plot of the meta-analysis.

Discussion

MD mostly occurs in children under 15 years of age.33 Lüdtke FE, Mende V, Köhler H, Lepsien G. Incidence and frequency or complications and management of Meckel’s diverticulum. Surg Gynecol Obstet. 1989;169:537-42. However, the age of the children was not clearly stated in the original literature included, so this meta-analysis could not be conducted by age groups. Some patients experience severe bleeding, which can be life-threatening. In recent years, the Tc-99m scan is the main method for clinical diagnosis of MD, and there are some new studies about the Tc-99m scan. So, the authors conducted a systematic review and meta-analysis of all published articles, to assess the sensitivity and specificity of the Tc-99m scan.

After screening the published studies based on selection criteria, the authors included 19 studies. Three of these studies, Rho JH’s study in 2013,1515 Rho JH, Kim JS, Kim SY, Kim SK, Choi YM, Kim SM, et al. Clinical features of symptomatic Meckel’s diverticulum in children: comparison of scintigraphic and non-scintigraphic diagnosis. Pediatr Gastroenterol Hepatol Nutr. 2013;16:41–8. Erratum in: Pediatr Gastroenterol Hepatol Nutr. 2013;16:135. Kim, Sung Min [corrected to Kim, Seong Min]; Kim, Yoon Mi [corrected to Kim, Yun Mi]. Rerksuppaphol’s study in 20041616 Rerksuppaphol S, Hutson JM, Oliver MR. Ranitidine-enhanced 99mtechnetium pertechnetate imaging in children improves the sensitivity of identifying heterotopic gastric mucosa in Meckel’s diverticulum. Pediatr Surg Int. 2004;20:323–5. and Chen Q’s study in 2018,1717 Chen Q, Gao Z, Zhang L, Zhang Y, Pan T, Cai D, et al. Multifaceted behavior of Meckel’s diverticulum in children. J Pediatr Surg. 2018;53:676–81. were excluded from the analysis because of their zero weights.

Finally, only 16 studies were included. Overall pooled diagnostic indices were as follows: sensitivity and specificity were 0.80 [Confidence Interval (95% CI, 0.73-0.86) and 0.95 (95% CI, 0.86-0.98)], respectively, indicating that most of them can be diagnosed in this way, and once diagnosed, they are confirmed.

However, the sensitivity of our study was much lower than the sensitivity of 92.1% (95% CI, 90.2-93.8) shown by Hosseinnezhad et al.,3333 Hosseinnezhad T, Shariati F, Treglia G, Kakhki VR, Sadri K, Kianifar HR, et al. 99mTc-pertechnetate imaging for detection of ectopic gastric mucosa: a systematic review and meta-analysis of the pertinent literature. Acta Gastroenterol Belg. 2014;77:318–27. perhaps because the authors included some new articles, which added to the differences between groups. Another reason may be the limitations of the Tc-99m scan itself, which has clinical significance only if patients have obvious clinical symptoms, which may have also resulted in the very high specificity of 0.95 (95% CI, 0.86-0.98) in our study.

The ideal timing of the scan remains controversial. Some studies reported that the scan should be performed when the child is not actively bleeding to prevent rapid dilution of the radioisotope.3434 Datz FL, Christian PE, Hutson WR, Moore JG, Morton KA. Physiological and pharmacological interventions in radionuclide imaging of the tubular gastrointestinal tract. Semin Nucl Med. 1991;21:140–52. However, other studies suggested that the scan should not be performed when there is no history of rectal bleeding. Hence, the timing of the scan and the method of capturing images are important.2424 Gelfand MJ, Silberstein EB, Cox J. Radionuclide imaging of Meckel’s diverticulum in children. Clin Nucl Med. 1978;3:4–8., 3333 Hosseinnezhad T, Shariati F, Treglia G, Kakhki VR, Sadri K, Kianifar HR, et al. 99mTc-pertechnetate imaging for detection of ectopic gastric mucosa: a systematic review and meta-analysis of the pertinent literature. Acta Gastroenterol Belg. 2014;77:318–27., 3535 Ayati NK, Zakavi SR, Sadeghi R, Kakhki VR. Delayed imaging for detection of Meckel’s diverticulum in case report Tc-99m pertechnetate scintigraphy. Iran J Nucl Med. 2008;16:45–8., 3636 Kumar R, Tripathi M, Chandrashekar N, Agarwala S, Kumar A, Dasan JB, Malhotra A. Diagnosis of ectopic gastric mucosa using 99Tcm-pertechnetate: spectrum of scintigraphic findings. Br J Radiol. 2005;78:714–20.

The sensitivity of the Tc-99m scan is affected by many factors, which is not only significantly related to the detection time in children (whether or not during active bleeding) but also closely related to the use of some drugs, such as H2 antagonists, 5-glutathione and glucagon, which can improve the accuracy of ectopic gastric mucosa detection and therefore affect the accuracy of diagnosis.3434 Datz FL, Christian PE, Hutson WR, Moore JG, Morton KA. Physiological and pharmacological interventions in radionuclide imaging of the tubular gastrointestinal tract. Semin Nucl Med. 1991;21:140–52., 3737 Saremi F, Jadvar H, Siegel ME. Pharmacologic interventions in nuclear radiology: indications, imaging protocols, and clinical results. Radiographics. 2002;22:477–90. For example, the use of H2 antagonists is particularly useful if there are insufficient gastric mucosal masses in the diverticulum or if the intradural imaging activity is diluted due to severe bleeding or excessive intestinal secretion, potentially leading to false negative scans. H2 antagonists such as ranitidine and cimetidine have been shown to improve scanning sensitivity by delaying the release of Tc-99m scan pertechnetate dye from mucosa and parietal cells.3636 Kumar R, Tripathi M, Chandrashekar N, Agarwala S, Kumar A, Dasan JB, Malhotra A. Diagnosis of ectopic gastric mucosa using 99Tcm-pertechnetate: spectrum of scintigraphic findings. Br J Radiol. 2005;78:714–20.

High heterogeneity was observed in our study. Hence, sensitivity analysis was performed on each data, and then subgroup analysis was performed on the results obtained from the sensitivity analysis. There was no statistically significant publication bias (Begg’s test p = 0.053) in our study. This result strongly demonstrates the reliability of our results.

The high heterogeneity was related to each study, including sample size, study design, and the number of included cases. Therefore, more multi-centric prospective randomized controlled studies are needed in the future to demonstrate the clinical effects of the Tc-99m scan. Another possible factor leading to high heterogeneity in our study was the different demographics and characteristics.

The present study overcame many shortcomings of the previous meta-analyses. The authors verified our literature search results and study selection criteria. However, there were several limitations in this study. First, most of the included studies were retrospective. Therefore, these studies are not as representative as prospective randomized controlled studies. Second, the included studies and sample size were limited. Third, there was considerable heterogeneity between studies.

Conclusion

Tc-99m scan has important diagnostic significance in the clinic. However, given the relatively moderate sensitivity, which is always influenced by some factors, multiple methods should be used to actively diagnose the disease in clinical practice to avoid serious complications.

References

  • 1
    Berquist TH, NG Nolan, AdsonMA, Schutt AJ. Diagnosis of Meckel’s diverticulum by radioisotope scanning. Mayo Clin Proc. 1973;48:98–102.
  • 2
    Kilpatrick ZM. Scanning in diagnosis of Meckel’s diverticulum. Hosp Practice. 1974;9:131–8.
  • 3
    Lüdtke FE, Mende V, Köhler H, Lepsien G. Incidence and frequency or complications and management of Meckel’s diverticulum. Surg Gynecol Obstet. 1989;169:537-42.
  • 4
    Das PC, Rao PL, Radhakrishna K. Meckel's diverticulum in children. J Postgrad Med. 1992;38:19–20.
  • 5
    Cserni G. Gastric pathology in Meckel’s diverticulum. Review of cases resected between 1965 and 1995. Am J Clin Pathol. 1996;106:782–5.
  • 6
    Rutherford RB, Akers DR. Meckel’s diverticulum: a review of 148 pediatric patients, with special reference to the pattern of bleeding and to mesodiverticular vascular bands. Surgery. 1966;59:618–26.
  • 7
    Harden R, Alexander WD. Isotope uptake and scanning of stomach in man with 99mTc-pertechnetate. Lancet. 1967;1:1305–7.
  • 8
    Jewett Jr TC, Duszynski DO, Allen JE. The visualization of Meckel’s diverticulum with 99mTc-pertechnetate. Surgery. 1970;68:567–70.
  • 9
    Jaros R, Schussheim A, Levy LM. Preoperative diagnosis of bleeding Meckel’s diverticulum utilizing 99m technetium per-technetate scinti-imaging. J Pediatr. 1973;82:45–9.
  • 10
    Wine CR, Nahrwold DL, Waldhausen JA. Role of the technetium scan in the diagnosis of Meckel’s diverticulum. J Pediatr Surg. 1974;9:885–8.
  • 11
    Sfakianakis GN, Conway JJ. Detection of ectopic gastric mucosa in Meckel’s diverticulum and in other aberrations by scintigraphy: I. Pathophysiology and 10-year clinical experience. J Nucl Med. 1981;22:647–54.
  • 12
    Swaniker F, Soldes O, Hirschl RB. The utility of technetium 99m pertechnetate scintigraphy in the evaluation of patients with Meckel’s diverticulum. J Pediatr Surg. 1999;34:760–4. discussion 765.
  • 13
    Howarth DM. The role of nuclear medicine in the detection of acute gastrointestinal bleeding. Semin Nucl Med. 2006;36: 133–46.
  • 14
    Ford PV, Bartold SP, Fink-Bennett DM, Jolles PR, Lull RJ, Maurer AH, Seabold JE. Procedure guideline for gastrointestinal bleeding and Meckel’s diverticulum scintigraphy. Society of Nuclear Medicine. J Nucl Med. 1999;40:1226–32.
  • 15
    Rho JH, Kim JS, Kim SY, Kim SK, Choi YM, Kim SM, et al. Clinical features of symptomatic Meckel’s diverticulum in children: comparison of scintigraphic and non-scintigraphic diagnosis. Pediatr Gastroenterol Hepatol Nutr. 2013;16:41–8. Erratum in: Pediatr Gastroenterol Hepatol Nutr. 2013;16:135. Kim, Sung Min [corrected to Kim, Seong Min]; Kim, Yoon Mi [corrected to Kim, Yun Mi].
  • 16
    Rerksuppaphol S, Hutson JM, Oliver MR. Ranitidine-enhanced 99mtechnetium pertechnetate imaging in children improves the sensitivity of identifying heterotopic gastric mucosa in Meckel’s diverticulum. Pediatr Surg Int. 2004;20:323–5.
  • 17
    Chen Q, Gao Z, Zhang L, Zhang Y, Pan T, Cai D, et al. Multifaceted behavior of Meckel’s diverticulum in children. J Pediatr Surg. 2018;53:676–81.
  • 18
    Papparella A, Nino F, Noviello C, Marte A, Parmeggiani P, Martino A, et al. Laparoscopic approach to Meckel’s diverticulum. World J Gastroenterol. 2014;20:8173–8.
  • 19
    Shalaby RY, Soliman SM, Fawy M, Samaha A. Laparoscopic management of Meckel’s diverticulum in children. J Pediatr Surg. 2005;40:562–7.
  • 20
    Al Janabi M, Samuel M, Kahlenberg A, Kumar S, Al-Janabi M. Symptomatic paediatric Meckel’s diverticulum: stratified diagnostic indicators and accuracy of Meckel’s scan. Nucl Med Commun. 2014;35:1162–6.
  • 21
    Sancar S, Demirci H, Sayan A, Arʅkan A, Candar A. Meckel’s diverticulum: ten years’ experience. Ulus Cerrahi Derg. 2015;31:65–7.
  • 22
    Leonidas JC, Germann DR. Technetium-99m pertechnetate imaging in diagnosis of Meckel’s diverticulum. Arch Dis Child. 1974;49:21–6.
  • 23
    Cooney DR, Duszynski DO, Camboa E, Karp MP, Jewett Jr. TC. The abdominal technetium scan (a decade of experience). J Pediatr Surg. 1982;17:611–9.
  • 24
    Gelfand MJ, Silberstein EB, Cox J. Radionuclide imaging of Meckel’s diverticulum in children. Clin Nucl Med. 1978;3:4–8.
  • 25
    Ho JE, Konieczny KM. The sodium pertechnetate Tc 99m scan: an aid in the evaluation of gastrointestinal bleeding. Pediatrics. 1975;56:34–40.
  • 26
    Fries M, Mortensson W, Robertson B. Technetium pertechnetate scintigraphy to detect ectopic gastric mucosa in Meckel’s diverticulum. Acta Radiol Diagn. 1984;25:417–22.
  • 27
    Poulsen KA, Qvist N. Sodium pertechnetate scintigraphy in detection of Meckel’s diverticulum: is it usable? Eur J Pediatr Surg. 2000;10:228–31.
  • 28
    Kong MS, Huang SC, Tzen KY, Lin JN. Repeated technetium-99m pertechnetate scanning for children with obscure gastrointestinal bleeding. J Pediatr Gastroenterol Nutr. 1994;18:284–7.
  • 29
    Sinha CK, Pallewatte A, Easty M, De Coppi P, Pierro A, Misra D, et al. Meckel’s scan in children: a review of 183 cases referred to two paediatric surgery specialist centres over 18 years. Pediatr Surg Int. 2013;29:511–7.
  • 30
    Dolezal J, Vizda J. Experiences with detection of the ectopic gastric mucosa by means of Tc-99m pertechnetate disodium scintigraphy in children with lower gastrointestinal bleeding. Eur J Pediatr Surg. 2008;18:258–60.
  • 31
    Mittal BR, Kashyap R, Bhattacharya A, Singh B, Radotra BD, Narasimha Rao KL. Meckel’s diverticulum in infants and children; technetium-99m pertechnetate scintigraphy and clinical findings. Hell J Nucl Med. 2008;11:26–9.
  • 32
    McCulleyS, Millar AJ, Mann MD, RodeH, Brown RA. The value of sodium pertechnetate Tc99m scans in the diagnosis of Meckel’s diverticulum. Pediatr Surg Int. 1996;11:240–2.
  • 33
    Hosseinnezhad T, Shariati F, Treglia G, Kakhki VR, Sadri K, Kianifar HR, et al. 99mTc-pertechnetate imaging for detection of ectopic gastric mucosa: a systematic review and meta-analysis of the pertinent literature. Acta Gastroenterol Belg. 2014;77:318–27.
  • 34
    Datz FL, Christian PE, Hutson WR, Moore JG, Morton KA. Physiological and pharmacological interventions in radionuclide imaging of the tubular gastrointestinal tract. Semin Nucl Med. 1991;21:140–52.
  • 35
    Ayati NK, Zakavi SR, Sadeghi R, Kakhki VR. Delayed imaging for detection of Meckel’s diverticulum in case report Tc-99m pertechnetate scintigraphy. Iran J Nucl Med. 2008;16:45–8.
  • 36
    Kumar R, Tripathi M, Chandrashekar N, Agarwala S, Kumar A, Dasan JB, Malhotra A. Diagnosis of ectopic gastric mucosa using 99Tcm-pertechnetate: spectrum of scintigraphic findings. Br J Radiol. 2005;78:714–20.
  • 37
    Saremi F, Jadvar H, Siegel ME. Pharmacologic interventions in nuclear radiology: indications, imaging protocols, and clinical results. Radiographics. 2002;22:477–90.

Publication Dates

  • Publication in this collection
    13 Oct 2023
  • Date of issue
    2023

History

  • Received
    10 Jan 2023
  • Accepted
    13 Mar 2023
  • Published
    02 June 2023
Sociedade Brasileira de Pediatria Av. Carlos Gomes, 328 cj. 304, 90480-000 Porto Alegre RS Brazil, Tel.: +55 51 3328-9520 - Porto Alegre - RS - Brazil
E-mail: jped@jped.com.br