In the present issue of Radiologia Brasileira there is an interesting study aimed at determining reference intervals for the fetal cisterna magna volume by means of the two-dimensional (2D) method with the multiplanar mode of Three-dimensional ultrasonography ( 3D US)(1Nardozza LMM, Passos AP, Araujo Júnior E, et al. Intervalos de referência para o volume da cisterna magna fetal por meio do método bidimensional usando o modo multiplanar da ultrassonografia tridimensional. Radiol Bras 2014;47:201-5.). The recent development in medical imaging have allowed for an accurate assessment of the fetal morphology. The study of the posterior fossa (PF) is included in all the routines for evaluation of the fetal morphology. The normal echographic parameters in this area rule out the main abnormalities of the cerebellum and vermis. However, in cases where any abnormality of the PF is found, a further and more accurate echographic evaluation of the central nervous system (CNS) should be undertaken(2Egle D, Strobl I, Weiskopf-Schwendinger V, et al. Appearance of the fetal posterior fossa at 11 + 3 to 13 + 6 gestational weeks on transabdominal ultrasound examination. Ultrasound Obstet Gynecol. 2011;38:620-4.).

US is ever the main method of choice in the fetal evaluation. However, in some cases, it may present some restrictions for a good evaluation of the CNS. Reverberation artifacts from the cranial bones and the low sensitivity in the detection of cortical malformations as well as those destructive of the cerebral parenchyma and cerebellum constitute some of the examples. Other limiting factors for a good echographic study include maternal obesity, oligohydramnios, inappropriate cephalic position, low qualification of the investigator and small field of view on the echographic image(3Malinger G, Lev D, Lerman-Sagie T. The fetal cerebellum. Pitfalls in diagnosis and management. Prenat Diagn. 2009;29:372-80.,4Werner H, dos Santos JRL, Fontes R, et al. Additive manufacturing models of fetuses built from three-dimensional ultrasound, magnetic resonance imaging and computed tomography scan data. Ultrasound Obstet Gynecol. 2010;36:355-61.).

The routine prenatal evaluation of the CNS by 2D US includes three main imaging planes: transthalamic, transventricular and transcerebellar. A baseline evaluation of the PF is based on the axial plane with special attention to the transducer angulation so that the cavum of the septum pellucidum, cerebral peduncles and cerebellar hemispheres can be visualized. It is important to note that if the transducer is angulated in the semicoronal plane, the anteroposterior measurement of the PF may be artificially increased(5Gandolfi Colleoni G, Contro E, Carletti A, et al. Prenatal diagnosis and outcome of fetal posterior fossa fluid collections. Ultrasound Obstet Gynecol. 2012;39:625-31.,6Serhatlioglu S, Kocakoc E, Kiris A, et al. Sonographic measurement of the fetal cerebellum, cisterna magna, and cavum septum pellucidum in normal fetuses in the second and third trimesters of pregnancy. J Clin Ultrasound. 2003;31:194-200.). With such an evaluation, one can say that the PF is normal as the three following criteria are met: measurement of the cisterna magna ≤ 10 mm; cross-sectional diameter of the cerebellum compatible with the gestational age; and normal cerebellar anatomy, defined by a vermis surrounded by two symmetrical hemispheres separating the fourth ventricle anteriorly and the cisterna magna posteriorly.

Provided no abnormality is found on such planes, the fetal brain normality can be presumed. If any abnormality is found, additional sections should be evaluated, besides the possibility of utilizing a transvaginal probe and 3D technology(6Serhatlioglu S, Kocakoc E, Kiris A, et al. Sonographic measurement of the fetal cerebellum, cisterna magna, and cavum septum pellucidum in normal fetuses in the second and third trimesters of pregnancy. J Clin Ultrasound. 2003;31:194-200.,7Paladini D, Volpe P. Posterior fossa and vermian morphometry in the characterization of fetal cerebellar abnormalities: a prospective three-dimensional ultrasound study. Ultrasound Obstet Gynecol. 2006;27:482-9.). In cases where all these resources do not allow for a complete evaluation, magnetic resonance imaging should be recommended(8Chen SC, Simon EM, Haselgrove JC, et al. Fetal posterior fossa volume: assessment with MR imaging. Radiology. 2006;238:997-1003.,9Malinger G, Werner H, Rodriguez Leonel JC, et al. Prenatal brain imaging in congenital toxoplasmosis. Prenat Diagn. 2011;31:881-6.).

Although the standard axial planes can demonstrate most PF anomalies, it may be difficult to make an accurate diagnosis. Subtle changes in the vermis, for example, may be occult. Malinger et al. have proposed the utilization of the sagittal plane with transvaginal approach for a better evaluation(3Malinger G, Lev D, Lerman-Sagie T. The fetal cerebellum. Pitfalls in diagnosis and management. Prenat Diagn. 2009;29:372-80.). The development of 3D US has brought advantages in the evaluation of the PF(1010 de Barros FS, Bussamra LC, Araujo Júnior E, et al. Comparison of fetal cerebellum and cisterna magna length by 2D and 3D ultrasonography between 18 and 24 weeks of pregnancy. ISRN Obstet Gynecol. 2012;2012:286141.). New tools, such as surface mode and multiplanar imaging have been incorporated into the evaluation both at transabdominal and transvaginal approaches. With multiplanar mode, the visualization of the axial, coronal and sagittal planes has become much easier. Thus, on a single image acquisition, it is possible to make an evaluation of all those imaging planes in addition to a volumetric evaluation(3Malinger G, Lev D, Lerman-Sagie T. The fetal cerebellum. Pitfalls in diagnosis and management. Prenat Diagn. 2009;29:372-80.,9Malinger G, Werner H, Rodriguez Leonel JC, et al. Prenatal brain imaging in congenital toxoplasmosis. Prenat Diagn. 2011;31:881-6.

10 de Barros FS, Bussamra LC, Araujo Júnior E, et al. Comparison of fetal cerebellum and cisterna magna length by 2D and 3D ultrasonography between 18 and 24 weeks of pregnancy. ISRN Obstet Gynecol. 2012;2012:286141.
-1111 Bertucci E, Gindes L, Mazza V, et al. Vermian biometric parameters in the normal and abnormal fetal posterior fossa: three-dimensional sonographic study. J Ultrasound Med. 2011;30:1403-10.)
.

Therefore, the imaging evaluation of the PF can be facilitated by the 3D technology. However, such advance in echographic imaging is still limited by the inappropriate positioning of the fetal cephalic pole or by the decreased volume of amniotic fluid, among others. Thus, in cases where US is not conclusive, the utilization of magnetic resonance imaging should ever be considered.

REFERÊNCIAS

  • 1
    Nardozza LMM, Passos AP, Araujo Júnior E, et al. Intervalos de referência para o volume da cisterna magna fetal por meio do método bidimensional usando o modo multiplanar da ultrassonografia tridimensional. Radiol Bras 2014;47:201-5.
  • 2
    Egle D, Strobl I, Weiskopf-Schwendinger V, et al. Appearance of the fetal posterior fossa at 11 + 3 to 13 + 6 gestational weeks on transabdominal ultrasound examination. Ultrasound Obstet Gynecol. 2011;38:620-4.
  • 3
    Malinger G, Lev D, Lerman-Sagie T. The fetal cerebellum. Pitfalls in diagnosis and management. Prenat Diagn. 2009;29:372-80.
  • 4
    Werner H, dos Santos JRL, Fontes R, et al. Additive manufacturing models of fetuses built from three-dimensional ultrasound, magnetic resonance imaging and computed tomography scan data. Ultrasound Obstet Gynecol. 2010;36:355-61.
  • 5
    Gandolfi Colleoni G, Contro E, Carletti A, et al. Prenatal diagnosis and outcome of fetal posterior fossa fluid collections. Ultrasound Obstet Gynecol. 2012;39:625-31.
  • 6
    Serhatlioglu S, Kocakoc E, Kiris A, et al. Sonographic measurement of the fetal cerebellum, cisterna magna, and cavum septum pellucidum in normal fetuses in the second and third trimesters of pregnancy. J Clin Ultrasound. 2003;31:194-200.
  • 7
    Paladini D, Volpe P. Posterior fossa and vermian morphometry in the characterization of fetal cerebellar abnormalities: a prospective three-dimensional ultrasound study. Ultrasound Obstet Gynecol. 2006;27:482-9.
  • 8
    Chen SC, Simon EM, Haselgrove JC, et al. Fetal posterior fossa volume: assessment with MR imaging. Radiology. 2006;238:997-1003.
  • 9
    Malinger G, Werner H, Rodriguez Leonel JC, et al. Prenatal brain imaging in congenital toxoplasmosis. Prenat Diagn. 2011;31:881-6.
  • 10
    de Barros FS, Bussamra LC, Araujo Júnior E, et al. Comparison of fetal cerebellum and cisterna magna length by 2D and 3D ultrasonography between 18 and 24 weeks of pregnancy. ISRN Obstet Gynecol. 2012;2012:286141.
  • 11
    Bertucci E, Gindes L, Mazza V, et al. Vermian biometric parameters in the normal and abnormal fetal posterior fossa: three-dimensional sonographic study. J Ultrasound Med. 2011;30:1403-10.

Publication Dates

  • Publication in this collection
    Jul-Aug 2014
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem Av. Paulista, 37 - 7º andar - conjunto 71, 01311-902 - São Paulo - SP, Tel.: +55 11 3372-4541, Fax: 3285-1690, Fax: +55 11 3285-1690 - São Paulo - SP - Brazil
E-mail: radiologiabrasileira@cbr.org.br