In the present work, the corrosion resistance of an ASTM A 387 G11 steel was evaluated under two conditions: an oxidizing atmosphere in a fluid catalytic cracking regenerator of a petroleum processing unit and a simulated atmosphere in the laboratory, at temperatures of 650 °C and 700 °C. The characterization of the phases present in the oxidized layer was carried out by X-ray diffraction (XRD), optical microscopy (OM) and scanning electron microscopy (SEM) with X-ray energy dispersive analysis (EDS). Severe corrosion was observed after exposure to both the real and simulated conditions, with formation of several iron oxides (Fe2O3, Fe3O4 and FeO) in the product scale layer, as well as a slight inner oxidation and sulfidation of chromium in the substrate. Internal nitridation of the silicon and the manganese was observed only in the real condition, probably related to the long-term exposure inside the regenerator.
corrosion resistance; low alloy steel; oxidant atmosphere; regenerator; petroleum processing unit
Corrosion resistance of a steel under an oxidizing atmosphere in a fluid catalytic cracking regenerator
Ieda CaminhaI; Chaoliu ZengII; Marcelo Piza PaesIII; Maurício Jesus MonteiroIV; Fernando RizzoIV, * * e-mail: rizzo@dcmm.puc-rio.br
IInstituto Nacional de Tecnologia, Laboratório de Metalografia e de Dureza Av. Venezuela, 82, sala 626, 20081-310 Rio de Janeiro, Brazil
IIInstitute of Corrosion and Protection of Metals,State Key Laboratory for Corrosion and Protection, The Chinese Academy of Science, 110015 Shenyang, China
IIIPETROBRÁS/CENPES/SUPEP/DIPLOT/SEMEC, Cidade Universitária Quadra 7, Ilha do Fundão, 21949-900 Rio de Janeiro, Brazil
IVPontifícia Universidade Católica do Rio de Janeiro,Departamento de Ciências dos Materiais e Metalurgia, Rua Marquês de São Vicente, 225, 22 453-900 Rio de Janeiro, Brazil
ABSTRACT
In the present work, the corrosion resistance of an ASTM A 387 G11 steel was evaluated under two conditions: an oxidizing atmosphere in a fluid catalytic cracking regenerator of a petroleum processing unit and a simulated atmosphere in the laboratory, at temperatures of 650 °C and 700 °C. The characterization of the phases present in the oxidized layer was carried out by X-ray diffraction (XRD), optical microscopy (OM) and scanning electron microscopy (SEM) with X-ray energy dispersive analysis (EDS). Severe corrosion was observed after exposure to both the real and simulated conditions, with formation of several iron oxides (Fe2O3, Fe3O4 and FeO) in the product scale layer, as well as a slight inner oxidation and sulfidation of chromium in the substrate. Internal nitridation of the silicon and the manganese was observed only in the real condition, probably related to the long-term exposure inside the regenerator.
Keywords: corrosion resistance, low alloy steel, oxidant atmosphere, regenerator, petroleum processing unit
1. Introduction
Corrosion of materials may represent a heavy burden for industry in general, especially for the petroleum industry where the oil and gas compositions are responsible for reducing the service life of component materials of equipment due to severe corrosion attack and, consequently, to considerable expenses related to the maintenance and replacement of parts in a processing unit1-4. Production shutdown of a petroleum-processing unit can result in a loss of up to 80,000 distilled barrels in a single day.
In order to mitigate corrosion problems, two approaches are usually employed: the selection of corrosion resistant materials, which may increase the cost of equipment, or the application of a coating to a cheap but less corrosion resistance material. In recent years, several studies have been done in the field of coating protection and development of new alloys, aiming to minimize or eliminate corrosion on the metallic structure of critical parts. In the petroleum industry, thermally sprayed aluminum coatings have been successfully used for the protection of offshore and marine structures, due to its good corrosion resistance and consequent increase in the service life of metallic parts and equipments5.
In the present study, the corrosion resistance of an ASTM A 387 G11 low alloy steel was evaluated. This steel is widely employed in the manufacture of pressure vessels designed for elevated temperature service. Coupon samples were exposed to the oxidizing atmosphere in the regenerator region of a fluid catalytic cracking unit (FCCU) of an oil refinery and to a simulated condition in laboratory.
This study is relevant not only for the petroleum industry but also to those involving high temperature corrosion, such as thermal generation plants, because the understanding of the corrosion mechanisms at elevated temperature will allow for the optimization of the alloy and coating compositions used in such systems.
1. Experimental
Two experimental procedures were used: degradation of specimens in service and degradation of specimens in the laboratory, simulating the real conditions of service. In both cases, the corrosion resistance of an ASTM A 387 Grade 11 low alloy steel was evaluated, for which the nominal composition is presented in Table 1.
For the degradation of specimens in service, designated "real condition", the samples were fixed inside the regenerator of a fluid catalytic cracking unit, more specifically in the stand pipe well and orifice chamber regions, under an oxidant atmosphere provided by the burning of the coke adhered to the catalyst. A schematic of the FCCU and the place where the samples were fixed is shown in Fig. 1.The samples were subjected to a temperature of around 650 °C in the stand pipe well and 700 °C in the orifice chamber regions for two and a half years, which is the usual time of a campaign in a petroleum processing unit.
In the second procedure the service atmosphere was simulated in the laboratory and was designated "simulated condition". A gas mixture with the composition N2-2%O2 -3%SO2 -10%CO2 (vol%.) was used in order to simulate the atmosphere inside the regenerator. The resulting atmosphere was oxidizing, with the oxygen potential calculated to be 1.42 ´ 10-2 atm, the sulfur potential 6.79 ´ 10-34 atm and the carbon activity virtually zero. In this condition, the samples were hung in a quartz tube inside a vertical furnace that was coupled to a temperature controller (PID). The variation in temperature was smaller than 0.5°. The flux of gas mixture was introduced in the quartz tube minutes before the furnace started heating. The sample was placed inside the furnace after the temperature of interest was reached. Sample cooling occurred inside the furnace after it had been turned off. The samples were subjected to a test temperature of 700 °C during 70 h of treatment.
After removing the samples from the regenerator (real condition) and the furnace (simulated condition), cross sections were cut and cold mounted for conventional metallographic preparation. The corroded surfaces were analyzed by X-ray diffraction (XRD), optical microscopy (OM) and scanning electron microscopy (SEM) with X-ray energy dispersive analysis (EDS).
2. Results and Discussion
G11 steel before degradation
The original microstructure of the ASTM A 387 G11 before the corrosion degradation is presented in Fig. 2. It is constituted by ferrite and pearlite, with a fairly homogeneous grain size.
G11 steel subjected to the real condition
Severe corrosion was observed for both samples exposed to the oxidizing atmosphere inside the regenerator at the temperatures of 650 °C and 700 °C. The formation of several iron oxides such as Fe2O3, Fe3O4 and FeO, as well as a slight internal oxidation and sulfidation of the chromium and the iron in the substrate near the corroded layer/substrate interface were observed. A significant internal nitridation of the silicon and the manganese was also observed for both samples.
Figure 3 shows the morphology in cross-section of the G11 steel sample subjected to the real condition inside the regenerator, in the standpipe well region at 650 °C.
The iron oxides present in the corrosion layer were confirmed by X-ray diffraction and are in accordance with the Fe-O phase diagram for the temperature studied. The corroded layer was very homogeneous (Fig. 3a), with a thickness around 100 µm. The fissure present accross the layer, extending from the surface to the corroded layer/substrate interface (Fig. 3b), may have formed during the cooling or metallographic preparation. This thickness value is very low if one considers the long time of sample exposure (2 1/2 years). However, the original thickness of the corroded layer might be larger. It is possible that during the campaign time of the processing unit, the corroded layer detached due to the intense wear present in the standpipe well region.
Figure 4 shows, at higher magnification, the corroded layer/substrate interface of the G11 steel in the real condition at 650 °C.
The X-ray energy dispersive analysis -EDS confirmed the presence of oxygen, sulfur, chromium and iron, suggesting a slight internal oxidation and sulfidation of chromium and iron next to the interface. The porosity present in the corroded layer allowed quick oxygen and sulfur diffusion into the alloy, promoting the formation of iron and chromium oxides and sulfides beneath the layer. In those internal regions, the oxygen activity becomes very low while sulfur activity becomes relatively high, leading to the formation of chromium and iron sulfides6-11.
Figure 5 shows the internal precipitation found in the G11 steel subjected to the real condition at 650 °C. There was significant internal precipitation (Fig. 5a) throughout the entire substrate. The morphology of the precipitates was irregular both in size and geometry. An EDS spectrum (Fig. 5b) confirmed the presence of nitrogen, silicon and manganese suggesting an internal nitridation of the silicon and the manganese present in the alloy. The long time of exposure in the real service conditions (2.5 years), in which the temperature could reach 1000-1100 °C due to the burning of abnormal amount of coke in the catalyst surface, allowed nitrogen diffusion into the alloy and the reaction with less noble metals (Mn, Si), leading to the formation of manganese and silicon nitride12-13. In this case, the oxygen activity becomes very low (around 10-28 atm) while nitrogen activity becomes relatively high (around 10-3 atm), leading to the formation of silicon and manganese nitrides (Si3N4 and Mn4N), according to phase stability diagrams for Si-Mn-O and Si-Mn-N systems14.
The G11 steel sample subjected to the real condition at 700 °C showed a similar corrosion behavior to that at 650 °C. This can be seen in the Fig. 6 and 7. However, the thickness of the corroded layer, approximately 1000 µm, is compatible with the long time of exposure during the campaign of the processing unit (2.5 years).
Significant internal nitridation of the silicon and the manganese was also observed, with the long time of exposure in the real condition undoubtedly being responsible for the intense precipitation. The amount of precipitates in the G11 steel subjected to the higher temperature (700 °C) is larger when compared to the sample exposed to the lower temperature (650 °C), indicating the occurrence of higher nucleation rate which is a contradiction with the theory. This apparent contradiction can be explained because the sample subjected to the higher temperature was fixed in the orifice chamber region (Fig. 1), where the temperature changes during the abnormal FCCU operation conditions were not so significant when compared to the sample fixed in the stand pipe well region, where the temperature could reach 1000-1100 ºC. Another feature that could contribute to increase the amount of internal precipitates is the higher solubility of nitrogen in the alloy at 700 °C, 1685.4 ppm vs. 1335.8 ppm at 650 °C.
G11 Steel subjected to the simulated condition
Similar to the G11 steel samples exposed to the real condition at 650 °C and 700 °C, severe corrosion as well as a slight internal oxidation and sulfidation of the chromium and the iron near the corroded layer/substrate interface was observed in the sample subjected to the simulated condition at 700 °C. However, the corroded layer was not homogeneous when compared to those resulting from the real condition, presenting two distinct layers: the smoother external one, constituted predominantly by Fe3O4 and the inner layer with great porosity, where the EDS analysis detected primarily sulfur and chromium, leading probably to the formation of Cr2S3. The corroded layer was detached from the substrate along their interface.
Figure 8a shows the general view of the corroded layer and substrate. One can observe clearly the presence of two distinct layers and the detachment of the corroded layer from the substrate. In Fig. 8b, the internal oxidation and sulfidation of the substrate are indicated by arrows.
No sign of internal nitridation of the silicon and the manganese was observed in the G11 steel sample subjected to the simulated condition at 700 °C during 70 h. This may be an indication that the internal precipitation is related to the long time of exposure inside the regenerator (2.5 years) in the real service condition.
3. Conclusions
Exposure of the G11 steel samples to both real and simulated conditions allowed for easy oxygen and sulfur ingress into the substrate, promoting the formation of a corroded layer containing Fe oxides. The occurrence of internal sulfidation and oxidation next to the corroded layer/substrate interface was also observed.
There was significant internal nitridation of the silicon and the manganese observed in the G11 steel samples subjected to the real condition, which is probably related to the long time of exposure inside the regenerator of the fluid catalytic cracking unit.
The oxidizing atmosphere in both the real and simulated conditions, allowed for the rather rapid penetration of oxygen, sulfur, and nitrogen into the alloy, leading to internal oxidation, sulfidation, and nitridation of the G11 steel, suggesting that this steel cannot be employed in the atmosphere studied.
Acknowledgments
The authors thank the Science and Technology Ministry of Brazil and FINEP for the financial support trough ÔMEGA project and USIMINAS for supplying the steel.
14. Software HSC OUTOKUMPU.
Received: September 2, 2002
Revised: September 4, 2002
Presented at the International Symposium on High Temperature Corrosion in Energy Related Systems, Angra dos Reis - RJ, September 2002
- 1. Charles, J.; Bonnefopis, B.; Dupoiron, F. Materials Science and Engineering, v. 87, p. 151-159, 1987.
- 2. May, V.E. Materials Performance, p. 18-22, 1985.
- 3. Walker, H.B. Hydrocarbon Processing, p. 80-84, 1984.
- 4. Agarwal, D.C.; Brill, U.; Heubner, U. The NACE Annual Conference, Paper n. 451 1992.
- 5. Fischer, K.P.; Thomason, W.H.; Rosbrook, T.; Murali, J. The NACE Annual Conference, Paper n. 499, 1994.
- 6. Wood, G.C. Oxidation of Metals, v. 2, n.1, p. 11-56, 1970.
- 7. Kofstad, P. High Temperature Corrosion, Elsevier Applied Science, London & New York, 1988.
- 8. Giggins, C.S.; Petit, F.S. Oxidation of Metals, v. 14, n. 5, p. 363-413, 1980.
- 9. Young, D.J.; Watson, S. Oxidation of Metals, v. 44, n. 1/2, p. 239-263, 1995.
- 10. Caminha, I.; et all Materials Science Forum, v. 369-372, p. 655-662, 2001.
- 11. Rizzo, F.; et all., The NACE Annual Conference, Paper n. 1169, 2001.
- 12. Besters, D. Diffusion, American Society of Metals, Metals Park, OH, p. 209-240, 1973.
- 13. Leslie, W. Physical Metallurgy of Steels, McGraw-Hill, New York, p. 112, 1981.
Publication Dates
-
Publication in this collection
25 May 2004 -
Date of issue
Mar 2004
History
-
Received
02 Sept 2002 -
Accepted
04 Sept 2002