Acessibilidade / Reportar erro

Bacteria and protozoa populations in groundwater in landfill area in São Carlos, SP

Populações de bactérias e protozoários em águas subterrâneas na área de um aterro controlado em São Carlos, SP

The microbial populations of groundwaters were analyzed in a region under the influence of a landfill (piezometer L12) in the town of São Carlos, São Paulo, Brazil, and in an area not influenced by the landfill (piezometer L5). Heterotrophic bacteria were counted by spread plate method and the number of protozoa was estimated by the most probable number method. There was a larger number of organisms in well L12, with a mean value of 15.76 x 104 CFU/ml for bacteria and 9.7 MPN/ml for protozoa, whereas the mean values for piezometer L5 were 2.88 x 104 CFU/ml for bacteria and 3.4 MPN/ml for protozoa. The greater abundance detected in piezometer L12 may be related to the influence of the leachate through the landfill on the microbial populations, also demonstrated by deoxygenation and by the high conductivity values (3530 µS/cm) compared to piezometer L5 (2.47 mg/L dissolved oxygen and 42 µS/cm conductivity). The most commonly detected protozoa were amoebae and flagellates. The density of flagellate protozoa determined under microaerophilic conditions was 10 times higher than that determined under aerobic conditions.

bacteria; protozoa; groundwater; landfill


Sociedade Brasileira de Microbiologia Av. Prof. Lineu Prestes, 1374, Cidade Universitária, 05508-900 São Paulo SP - Brazil, Tel. / Fax: (55 11) 813.9647 - São Paulo - SP - Brazil
E-mail: bjm@sbmicrobiologia.org.br