SciELO - Scientific Electronic Library Online

 
vol.84 número4Use of the correlation coefficient in agricultural sciences: problems, pitfalls and how to deal with themEvaluation of motorcyclist's discomfort during prolonged riding process with and without lumbar support índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

Compartilhar


Anais da Academia Brasileira de Ciências

versão impressa ISSN 0001-3765

Resumo

WEE, Lai K. et al. Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments. An. Acad. Bras. Ciênc. [online]. 2012, vol.84, n.4, pp.1157-1168. ISSN 0001-3765.  http://dx.doi.org/10.1590/S0001-37652012000400030.

Current two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D) marker evaluation. This is essentially important to analyze that the measurement on 3D volumetric measurement possesses higher impact and reproducibility vis-à-vis 2D measurement. Twenty three cases of prenatal ultrasound examination were obtained from collaborating hospital after Ethical Committee's approval. The measured 2D ultrasonic marker is Nuchal Translucency or commonly abbreviated as NT. Descriptive analysis of both 2D and 3D ultrasound measurement were calculated. Three trial measurements were taken for each method. Both data were tested with One-Sample Kolmogorov-Smirnov Test and results indicate that markers measurements were distributed normally with significant parametric values at 0.621 and 0.596 respectively. Computed mean and standard deviation for both measurement methods are 1.4495 ± 0.46490 (2D) and 1.3561 ± 0.50994 (3D). ANOVA test shows that computerized 3D measurements were found to be insignificantly different from the mean of conventional 2D at the significance level of 0.05. With Pearson's correlation coefficient value or R = 0.861, the result proves strong positive linear correlation between 2D and 3D ultrasonic measurements. Reproducibility and accuracy of 3D ultrasound in NT measurement was significantly increased compared with 2D B-mode ultrasound prenatal assessment. 3D reconstructed imaging has higher clinical values compare to 2D ultrasound images with less diagnostics information.

Palavras-chave : three dimensional (3D); ultrasound; nuchal translucency (NT); fold thickness; Trisomy; Down Syndrome.

        · resumo em Português     · texto em Inglês     · Inglês ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons