SciELO - Scientific Electronic Library Online

 
vol.75 issue3Strabismus surgery learning for Ophthalmology residents of university serviceComparative study between gelatinous and hard spheres of silicone in rabbit eviscerated scleral cavity author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Arquivos Brasileiros de Oftalmologia

Print version ISSN 0004-2749

Abstract

FERRER-BLASCO, Teresa et al. Refractive lens exchange with a multifocal diffractive aspheric intraocular lens. Arq. Bras. Oftalmol. [online]. 2012, vol.75, n.3, pp. 192-196. ISSN 0004-2749.  http://dx.doi.org/10.1590/S0004-27492012000300009.

PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively). The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group). CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.

Keywords : Lens implantation, intraocular; Lens, crystalline [surgery]; Myopia [surgery]; Hyperopia [physiopathology]; Phacoemulsification; Prosthesis design; Tonometry, ocular; Visual acuity.

        · abstract in Portuguese     · text in English     · pdf in English