SciELO - Scientific Electronic Library Online

 
vol.88 número1Curvas de referência da Escala Motora Infantil de Alberta: percentis para descrição clínica e acompanhamento do desempenho motor ao longo do tempoConfiabilidade do módulo Satisfação com o Serviço de Saúde do questionário Pediatric Quality of Life Inventory versão 3.0 na avaliação do atendimento de crianças e adolescentes com doenças crônicas índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Jornal de Pediatria

versão impressa ISSN 0021-7557

Resumo

MEDEIROS, Sara Karla F. de; CARVALHO, Werther Brunow de  e  SORIANO, Cláudio F. R.. Practices of use of nasal intermittent positive pressure ventilation (NIPPV) in neonatology in northeastern Brazil. J. Pediatr. (Rio J.) [online]. 2012, vol.88, n.1, pp. 48-53. ISSN 0021-7557.  http://dx.doi.org/10.2223/JPED.2157.

OBJECTIVES: To investigate the use of nasal intermittent positive pressure ventilation (NIPPV) in level three neonatal intensive care units (NICU) in northeastern Brazil. METHODS: This observational cross-sectional survey was conducted from March 2009 to January 2010 in all level three NICUs in northeastern Brazil that are registered in the Brazilian Registry of Health Establishments (Cadastro Nacional de Estabelecimentos de Saúde, CNES) of the Ministry of Health. Questionnaires about the use of NIPPV were sent to the NICU directors in each institution. Statistical analysis was conducted using the software Epi-Info 6.04 and double data entry. A chi-square test was used to compare variables, and the level of statistical significance was set at p < 0.05. RESULTS: This study identified 93 level three NICUs in northeastern Brazil registered in CNES, and 87% answered the study questionnaire. Most classified themselves as private institutions (30.7%); 98.7% used NIPPV; 92.8% adapted mechanical ventilators for NIPPV and used short binasal prongs as the interface (94.2%). Only 17.3% of the units had a protocol for the use of NIPPV. Mean positive inspiratory pressure and positive end-expiratory pressure were 20.0 cmH2O (standard deviation [SD]: 4.47) and 5.0 cmH2O (SD: 0.84). CONCLUSION: NICUs in northeastern Brazil use nasal intermittent positive pressure ventilation, but indications and ventilation settings are not the same in the different institutions.

Palavras-chave : Ventilation; neonatology; intensive care units; infant.

        · resumo em Português     · texto em Português | Inglês     · pdf em Português | Inglês