vol.58 issue4Comparison of the plasma levels of 50% enantiomeric excess (S75/R25) 0.5% bupivacaine combined with 1: 200,000 epinephrine between the parasacral and infragluteal sciatic nerve blocksPreoperative intravenous clonidine in the surgical treatment of cataract: evaluation of the clinical benefits author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Revista Brasileira de Anestesiologia

Print version ISSN 0034-7094

Abstract

SILVA NETO, Walter Viterbo da et al. Evaluation of hemodynamic variations during anesthetic induction in treated hypertensive patients. Rev. Bras. Anestesiol. [online]. 2008, vol.58, n.4, pp. 330-341. ISSN 0034-7094.  http://dx.doi.org/10.1590/S0034-70942008000400002.

BACKGROUND AND OBJECTIVES: Due to the high prevalence of hypertension, the increase in life expectancy, and improvement of diagnostic methods and surgical techniques, this comorbidity will be increasingly more common in surgical patients. The objective of this study was to evaluate the behavior of the hemodynamic variables during anesthetic induction in treated hypertensive patients. METHODS: This is an observational study on the behavior of hemodynamic parameters (systolic blood pressure, diastolic blood pressure, and heart rate) during the anesthetic induction of hypertensive and normotensive patients scheduled for elective surgeries under general anesthesia, at four moments: preparation (MP), drug (MD), laryngoscopy/intubation (ML), and 5 minutes after laryngoscopy/intubation (ML5). RESULTS: The sample was composed of 128 patients divided into two groups: hypertensive (GH) and normotensive (GN). Diastolic blood pressure was reduced at MD in both groups, with a smaller percentage reduction in GH (18.3 ± 14.0% versus 23.0 ± 11.4%, p = 0.04). There was an increase in SBP and DBP at ML in both groups, with smaller percentage reductions in GH (8.2 ± 16.3% versus 18.2 ± 21.2%, p < 0.01; 8.6 ± 20.2% versus 25.0 ± 27.9%, p < 0.01, respectively for DBP and SBP). As for ML5, HR, SBP and DBP did not show significant differences between both groups. CONCLUSIONS: Hypertensive patients under treatment and with controlled blood pressure levels demonstrated greater hemodynamic stability during anesthetic induction.

Keywords : ANESTHESIA [induction]; CARDIOVASCULAR SYSTEM [hemodynamic changes]; DISEASES [hypertension].

        · abstract in Portuguese | Spanish     · text in English | Portuguese     · pdf in English | Portuguese