Sebel et al. (1997)1818 Sebel PS, Lang E, Rampil IJ, et al. A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect. Anesth Analg. 1997;84:891-9.
|
Before incision tetanus stimulation was applied to the ulnar nerve. Any presence of movement, anesthesia was deepened. In the absence of movement, anesthesia was maintained. After incision any movement was considered for the deepening of anesthesia. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Yli-Hankala et al. (1999)1919 Yli-Hankala A, Vakkuri A, Annila P, et al. EEG bispectral index monitoring in sevoflurane or propofol anaesthesia: analysis of direct costs and immediate recovery. Acta Anaesthesiol Scand. 1999;43:545-9.
|
The data expression of the outcomes was made in medians. |
Mi et al. (1999)2020 Mi WD, Sakai T, Singh H, et al. Hypnotic endpoints vs. the bispectral index, 95% spectral edge frequency and median frequency during propofol infusion with or without fentanyl. Eur J Anaesthesiol. 1999;16:47-52.
|
Patients were monitored with BIS and outcomes were analyzed due to different anesthetic regimens. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Nakayama et al. (2002)2121 Nakayama M, Ichinose H, Yamamoto S, et al. The effect of fentanyl on hemodynamic and Bispectral Index changes during anesthesia induction with propofol. J Clin Anesth. 2002;14:146-9.
|
All patients were monitored with BIS and outcomes were analyzed due to different anesthetic regimens (only propofol or propofol and fentanyl). The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Lehmann et al. (2002)2222 Lehmann A, Boldt J, Thaler E, et al. Bispectral Index in patients with target-controlled or manually-controlled infusion of propofol. Anesth Analg. 2002;95:639-44.
|
All patients were monitored with BIS and analyzed outcomes resulting from different anesthetic techniques (with manual propofol infusion vs. propofol in Target Controlled Infusion – TCI). The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Paventi et al. (2002)2323 Paventi S, Santevecchi A, Perilli V, et al. Effects of remifentanil infusion BIS-titrated on early recovery for obese outpatients undergoing laparoscopic cholecystectomy. Minerva Anestesiol. 2002;68:651-7.
|
All patients were monitored with BIS and analyzed outcomes resulting from different anesthetic techniques (manual propofol infusion vs. propofol in TCI). The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Lehmann et al. (2003)2424 Lehmann A, Karzau J, Boldt J, et al. Bispectral Index-guided anesthesia in patients undergoing aortocoronary bypass grafting. Anesth Analg. 2003;96:336-43.
|
All patients were monitored with BIS (group BIS 50 and group BIS 40). The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Yamaguchi et al. (2003)2525 Yamaguchi S, Egawa H, Mishio M, et al. Bispectral monitoring during vital capacity rapid inhalation induction with sevoflurane. J Clin Anesth. 2003;15:24-8.
|
All patients were monitored with BIS and analyzed outcomes resulting from different anesthetic drugs and techniques (propofol group/iv induction and sevoflurane group with inhalational induction in adult by the vital capacity technique). The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Buyukkocak et al. (2003)2626 Buyukkocak U, Ozcan S, Daphan C, et al. A comparison of four intravenous sedation techniques and Bispectral Index monitoring in sinonasal surgery. Anaesth Intensive Care. 2003;31:164-71.
|
All patients were monitored with BIS and outcomes were analyzed due to different anesthetic drugs, four different methods of sedation associated with topical anesthesia. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Forestier et al. (2003)2727 Forestier F, Hirschi M, Rouget P, et al. Propofol and sufentanil titration with the Bispectral Index to provide anesthesia for coronary artery surgery. Anesthesiology. 2003;99:334-46.
|
All patients were monitored with BIS and analyzed five groups with different concentrations of sufentanil. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Schneider et al. (2003)2828 Schneider G, Gelb AW, Schmeller B, et al. Detection of awareness in surgical patients with EEG-based indices-bispectral index and patient state index. Br J Anaesth. 2003;91:329-35.
|
All patients were monitored with BIS and analyzed four different anesthetic regimens. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Schneider et al. (2003)2929 Schneider G, Elidrissi C, Sebel PS. Bispectral index-guided administration of anaesthesia: comparison between remifentanil/propofol and remifentanil/isoflurane. Eur J Anaesthesiol. 2003;20:624-30.
|
All patients were monitored with BIS and analyzed two different anesthetic regimens. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Liu (2004)3030 Liu SS. Effects of Bispectral Index monitoring on ambulatory anesthesia. Anesthesiology. 2004;101:311-315.
|
Meta-analysis. The criteria for inclusion in the systematic review were randomized controlled trials. |
Bauer et al. (2004)3131 Bauer M, Wilhelm W, Kraemer T, et al. Impact of Bispectral Index monitoring on stress response and propofol consumption in patients undergoing coronary artery bypass surgery. Anesthesiology. 2004;101:1096-104.
|
All patients were monitored with BIS and analyzed two different anesthetic regimens (TCI vs. manual propofol infusion). The BIS was used but is not described whether it was blinded. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Bestas et al. (2004)3232 Bestas A, Yasar MA, Bayar MK, et al. The effects of two different anaesthesia techniques on bispectral index values and awareness during off-pump coronary artery bypass grafting. J Clin Monit Comput. 2004;18:347-51.
|
All 50 patients (two groups of 25) were monitored with BIS and were blinded, with analysis of two different anesthetic regimes. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Boztug et al. (2006)3333 Boztug N, Bigat Z, Akyüz M, et al. Does using the Bispectral Index (BIS) during craniotomy affect the quality of recovery? J Neurosurg Anesthesiol. 2006;18:1-4.
|
Article not found. |
Puri et al. (2007)3434 Puri GD, Kumar B, Aveek J. Closed-loop anaesthesia delivery system (CLADS) using bispectral index: a performance assessment study. Anaesth Intensive Care. 2007;35:357-62.
|
All patients were monitored with BIS, with analysis of two different types of propofol infusion. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Lindholm et al. (2008)3535 Lindholm ML, Brudin L, Sandin RH. Bispectral index monitoring: appreciated but does not affect drug dosing and hypnotic levels. Acta Anaesthesiol Scand. 2008;52:88-94.
|
The paper analyzes the degree of proficiency in handling the BIS by nurses’ anesthetists. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Avidan et al. (2008)3636 Avidan MS, Zhang L, Burnside BA, et al. Anesthesia awareness and the Bispectral Index. N Engl J Med. 2008;358:1097-108.
|
In the control group, anesthesia was maintained with BIS “blinded” but with an expired fraction of 0.7–1.3 minimum alveolar concentration of inhaled anesthetic. |
Bejjani et al. (2009)3737 Bejjani G, Lequeux PY, Schmartz D, et al. No evidence of memory processing during propofol-remifentanil target-controlled infusion anesthesia with Bispectral Index monitoring in cardiac surgery. J Cardiothorac Vasc Anesth. 2009;23:175-81.
|
All patients were monitored with BIS with memory processing analysis. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Delfino et al. (2009)3838 Delfino AE, Cortinez LI, Fierro CV, et al. Propofol consumption and recovery times after bispectral index or cerebral state index guidance of anaesthesia. Br J Anaesth. 2009;103:255-9.
|
All patients were monitored with BIS or cerebral state index, with analysis of propofol infusion with these two types of monitoring. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Kerssens et al. (2009)3939 Kerssens C, Gaither JR, Sebel PS. Preserved memory function during Bispectral Index-guided anesthesia with sevoflurane for major orthopedic surgery. Anesthesiology. 2009;111:518-24.
|
Study of intraoperative memory and retrieval of words heard during the trans-operative, through memory tests postoperatively. |
Mashour et al. (2009)4040 Mashour GA, Tremper KK, Avidan MS. Protocol for the "Michigan Awareness Control Study": a prospective, randomized, controlled trial comparing electronic alerts based on bispectral index monitoring or minimum alveolar concentration for the prevention of intraoperative awareness. BMC Anesthesiol. 2009;9:7.
|
Cohort study. The criteria for inclusion in the systematic review were randomized controlled trials. |
Satisha et al. (2010)4141 Satisha M, Sanders GM, Badrinath MR, et al. Introduction of bispectral index monitoring in a district general hospital operating suite: a prospective audit of clinical and economic effects. Eur J Anaesthesiol. 2010;27:196-220.
|
Cohort study. The criteria for inclusion in the systematic review were randomized controlled trials. |
Meybohm et al. (2010)4242 Meybohm P, Gruenewald M, Höcker J, et al. Correlation and agreement between the bispectral index vs. state entropy during hypothermic cardio-pulmonary bypass. Acta Anaesthesiol Scand. 2010;54:169-75.
|
Protocol study. The criteria for inclusion in the systematic review were randomized controlled trials. |
Leslie et al. (2010)4343 Leslie K, Myles PS, Forbes A, et al. The effect of Bispectral Index monitoring on long-term survival in the B-Aware trial. Anesth Analg. 2010;110:816-22.
|
Retrospective cohort study. The criteria for inclusion in the systematic review were randomized controlled trials. |
Avidan et al. (2009)4444 Avidan MS, Palanca BJ, Glick D, et al. Protocol for the BAG-RECALL clinical trial: a prospective, multi-center, randomized, controlled trial to determine whether a bispectral index-guided protocol is superior to an anesthesia gas-guided protocol in reducing intraoperative awareness with explicit recall in high risk surgical patients. BMC Anesthesiol. 2009;9:8.
|
Protocol study. The criteria for inclusion in the systematic review were randomized controlled trials. |
Ellerkmann et al. (2010)4545 Ellerkmann RK, Soehle M, Riese G, et al. The Entropy Module and Bispectral Index as guidance for propofol-remifentanil anaesthesia in combination with regional anaesthesia compared with a standard clinical practice group. Anaesth Intensive Care. 2010;38:159-66.
|
Inhalation or intravenous anesthesia, complemented by regional anesthesia (combined anesthesia). The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Yufune et al. (2011)4646 Yufune S, Takamatsu I, Masui K, et al. Effect of remifentanil on plasma propofol concentration and bispectral index during propofol anaesthesia. Br J Anaesth. 2011;106:208-14.
|
The 38 patients were monitored with BIS and outcomes were analyzed due to different anesthetic regimens, as well as different concentrations of remifentanil. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Liu et al. (2011)4747 Liu N, Chazot T, Hamada S, et al. Closed-loop coadministration of propofol and remifentanil guided by Bispectral Index: a randomized multicenter study. Anesth Analg. 2011;112:546-57.
|
All patients were monitored with BIS and outcomes were analyzed due to different anesthetic regimens, target controlled infusion of propofol vs. closed-loop management. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Avidan et al. (2011)4848 Avidan MS, Jacobsohn E, Glick D, et al. Prevention of intraoperative awareness in a high-risk surgical population. N Engl J Med. 2011;365:591-600.
|
The control group was adjusted for maintaining an expired fraction of 0.7–1.3 minimum alveolar concentration of inhaled anesthetic. |
Aimé et al. (2012)4949 Aimé I, Gayat E, Fermanian C, et al. Effect of age on the comparability of bispectral and state entropy indices during the maintenance of propofol-sufentanil anaesthesia. Br J Anaesth. 2012;108:638-43.
|
The 102 patients were monitored with BIS or Entropy, in both groups, the values were blinded, and anesthesia was conducted by clinical parameters. The study goes out of focus – BIS intervention compared to the control group (consciousness guided by clinical parameters only). |
Mashour et al. (2012)5050 Mashour GA, Shanks A, Tremper KK, et al. Prevention of intraoperative awareness with explicit recall in an unselected surgical population. Anesthesiology. 2012;117:717-25.
|
The control group was blinded, but adjusted to a minimum alveolar concentration of inhaled anesthetic by age. |
Persec et al. (2012)5151 Persec J, Persec Z, Kopljar M, et al. Effect of bispectral index monitoring on extubation time and analgesic consumption in abdominal surgery: a randomised clinical trial. Swiss Med Wkly. 2012;142:w13689.
|
The results of this study cannot be meta-analyzed as they provide no standard deviation. |
Fritz et al. (2013)5252 Fritz BA, Rao P, Mashour GA, et al. Postoperative recovery with Bispectral Index versus anesthetic concentration-guided protocols. Anesthesiology. 2013;118:1113-22.
|
Retrospective cohort study. The criteria for inclusion in the systematic review were randomized controlled trials. |
Villafranca et al. (2013)5353 Villafranca A, Thomson IA, Grocott HP, et al. The impact of Bispectral Index versus end-tidal anesthetic concentration-guided anesthesia on time to tracheal extubation in fast-track cardiac surgery. Anesth Analg. 2013;116:541-8.
|
Retrospective cohort study. The criteria for inclusion in the systematic review were randomized controlled trials. |