BISINOTTO, Flora Margarida Barra et al. Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution. Rev. Bras. Anestesiol. [online]. 2017, vol.67, n.4, pp.376-382. ISSN 0034-7094.  https://doi.org/10.1016/j.bjane.2017.03.001.

Background and objectives:

The current preoperative fasting guidelines allow fluid intake up to 2 h before surgery. The aim of this study was to evaluate the gastric volume of volunteers after an overnight fast and compare it with the gastric volume 2 h after ingestion of 200 and 500 mL of isotonic solution, by means of ultrasound assessment.

Method:

Eighty volunteers underwent gastric ultrasound at three times: after 8 h of fasting; 2 h after ingestion of 200 mL isotonic saline, followed by the first scan; and on another day, 2 h after ingestion of 500 mL of the same solution after an overnight fast. The evaluation was quantitative (antrum area and gastric volume, and the ratio of participants’ gastric volume/weight) and qualitative (absence or presence of gastric contents on right lateral decubitus and supine positions. A p-value < 0.05 was considered significant).

Results:

There was no difference in quantitative variables at measurement times (p > 0.05). Five volunteers (6.25%) had a volume/weight over 1.5 mL kg-1 at fasting and 2 h after ingestion of 200 mL and 6 (7.5%) after 500 mL. Qualitatively, the presence of gastric fluid occurred in more volunteers after fluid ingestion, especially 500 mL (18.7%), although not statistically significant.

Conclusion:

Ultrasound assessment of gastric volume showed no significant difference, both qualitative and quantitative, 2 h after ingestion of 200 mL or 500 mL of isotonic solution compared to fasting, although gastric fluid content has been identified in more volunteers, especially after ingestion of 500 mL isotonic solution.

Keywords : Bronchoaspiration; Gastric ultrasound; Preoperative fasting.

        · abstract in Portuguese     · text in English | Portuguese     · English ( pdf ) | Portuguese ( pdf )