Acessibilidade / Reportar erro

Influence of external temporary biatrial pacing on the prevention of atrial fibrillation after coronary artery bypass without extracorporeal circulation

BACKGROUND: Atrial fibrillation is the most common complication after myocardial revascularization, and it increases morbidity/mortality. OBJECTIVE: The purpose of this prospective randomized study was to test the hypothesis that temporary biatrial pacing is effective in reducing the incidence of postoperative atrial fibrillation after myocardial revascularization. METHODS: Ninety-eight non-consecutive patients who had undergone off-pump myocardial revascularization received two temporary electrodes attached to the right and left atria, which were connected to either pair of atrial pacemaker electrodes, in addition to the leads implanted in the right ventricle. Two groups of patients were randomized (control: 49 patients with no biatrial pacing; therapeutic: 49 patients with biatrial pacing). The variables of interest were atrial fibrillation (present or absent) and length of hospital stay. RESULTS: The incidence of atrial fibrillation was 36.73% in the control group and 14.29% in the therapeutic group (p=0.0194). Length of hospital stay was 7.00 ± 2.82 days for patients with no atrial fibrillation (n=73) and 9.20 ± 2.87 days for patients with atrial fibrillation (n=25) (p=0.0001). Age was an important predictor of arrhythmia and ranged between 62.34 ± 9.00 years in the group with no atrial fibrillation and 67.20 ± 7.42 years in the group with atrial fibrillation (p=0.0170). CONCLUSION: Compared to controls, prophylactic temporary biatrial pacing is effective in preventing atrial fibrillation. Hospital stay was longer for patients who developed postoperative atrial fibrillation, and age was an important predictor for the development of arrhythmia.

Atrial fibrillation; cardiac pacing; artificial; myocardial revascularization


Sociedade Brasileira de Cardiologia - SBC Avenida Marechal Câmara, 160, sala: 330, Centro, CEP: 20020-907, (21) 3478-2700 - Rio de Janeiro - RJ - Brazil, Fax: +55 21 3478-2770 - São Paulo - SP - Brazil
E-mail: revista@cardiol.br